Ribao CS-311S Operation Manual

2+1 POCKETS COIN SORTER
CS-311S
CS-311S Operation Manual V1.2
Page 2 of 17
CONTENTS
1. Introduction ....................................................... 3
2. Specifications ..................................................... 3
3. Function ............................................................. 4
4.Diagram .............................................................. 4
5. Power Socket board ............................................ 5
6. Key Panel ........................................................... 6
7. Main Display Modes ............................................ 7
8. Operating Procedures ......................................... 7
9. Function Settings: ............................................ 10
10. Trouble Shooting ............................................ 15
11. Precautions: ................................................... 15
12. Daily Maintenance .......................................... 16
13. Accessories .................................................... 16
CS-311S Operation Manual V1.2
Page 3 of 17
1. Introduction
CS-311S is a coin sorter designed and produced by our company.
It has counterfeit coin detection function. With the installed advanced
eddy current sensor, it can simultaneously detect the metal coins’
diameter, thickness and material, based on this feature, our CS-311S
can automatically recognize foreign coins, counterfeit coins and sheet
metals etc. CS-311S can count and sort coins of programmed
denominations, during which process the foreign coins will be sorted
into Rejected Coin Drawer. Our CS-311S can be connected with printer,
external display or computer through RS-232 port. All data can be
printed out at any time.
2. Specifications
Sorting Speed
Approx.600coins/ min
Hopper Capacity
Approx.600pcs
Suitable Sorting Coin Range
Diameter 14-31mm
Thickness3.5mm
Sorting Number
Up to 20 kinds of denomination
Machine Dimension
365×280×294mm
Weight:
13Kg
Power Consumption
60W
Power Supply
AC 120V ± 10%, 60Hz
or AC 220V ± 10%, 50Hz
Display
LCD Display(24064)
Ambient Temperature
0-40C°
Humidity
30-75%
CS-311S Operation Manual V1.2
Page 4 of 17
3. Function
CS-311S is able to identify, count and sort the coins, it can identify at
most 20 kinds of denominations, also it has one reject pocket for fake
and foreign coins.
From left to right it is
channel2
channel1
reject pocket
The user can sort the desired denomination into the desired pocket. Foreign coins, fake coins and tokens will be sorted into reject pocket
4.Diagram
①:Key panel
②:Visible Window
③:Built-in printer(option)
④:Drawer
⑤:Handle
CS-311S Operation Manual V1.2
Page 5 of 17
5. Power Socket board
⑥:Power switch
⑦:Power socket
⑧:RS232for communication with PC
⑨:PS2reserved interface for external display
⑩:USBfor software upgrading
LANreserved socket for network
CS-311S Operation Manual V1.2
Page 6 of 17
6. Key Panel
Key Function:
1 0 ~ 9 : Numeric key for fast batch number settings 2START/STOP: Start or Stop 3SET: Set MENU or set some functions 4ESC: Return to MENU or clear rejected coin records 5CLR: Clear counting records or clear error codes
, , , : Select different Channels, or select different
Menu Setting; can also control Batch function ON/OFF, can
also control MIX-COUNT, SDC- COUNT.
6MR: Read memory data 7M+: Save Self-learning parameters 8LIST: Check detailed counting list 9Print: Print sorting result and Self-learning parameters
CS-311S Operation Manual V1.2
Page 7 of 17
7. Main Display Modes
1Total Amount & Quantity Display Mode:
MIX- COUNT STOP
VALUE: 125.90 COUNT: 190
B
F:
2
2Separate Channel Amount & Quantity Display Mode:
VALUE
COUNT
AMOUNT
2.00
50
100.00
0.50
0.01
50 90
25.00
0.90
8. Operating Procedures
Turn on the machine, the machine will enter into self-test mode and
show following interface
TESTING,PLEASE WAIT...
10
This self-test stage may needs about 10 seconds for machine to get
warmed up. If the test result is OK, then machine will enter into
normal working status shown as following interface:
MIX- COUNT STOP
VALUE: 0.00 COUNT: 0
B
F:
0
MODEL : CS311S VERSION:
MainBoard V1.0 DispBoard V1.0
ADBoard V1.0
CS-311S Operation Manual V1.2
Page 8 of 17
MIX-COUNT means mix-counting mode
RUN/STOP is the sign showing machine’s running or stop status.
B is the sign of Batch Function is ON.
VALUE is for total Amount. COUNT is for total Quantity, F shows the
quantity of foreign/fake coins.
·Press START/STOP keythe machine will enter into Total Amount &
Quantity Display Mode interface:
MIX- COUNT RUN
VALUE: 0.00 COUNT: 0
B
F:
0
At the same time, Motor will begin to run to get the machine work.
When coin sorting is finished, it will display the sorting result of
genuine and foreign coins on the above interface. The foreign coins
will be rejected into the right-most Rejected Coin Drawer.
After the machine stops running, press LIST key to check
Separate Channel Amount & Quantity Display Mode, shown as follows:
(Press key to turn to choose different channel)
VALUE
COUNT
AMOUNT
2.00
50
100.00
0.50
0.01
50 90
25.00
0.90
VALUE: refers to the denomination
COUNT: refers to the quantity for each denomination
AMOUNT: refers the amount for each denomination
Modes shift:
Under main interface, press Key to shift the modes, which is
MIX-COUNT, SDC-MODE, SDC-REJECT accordingly. The display is
CS-311S Operation Manual V1.2
Page 9 of 17
shown as below:
SDC- COUNT STOP
VALUE: 0.00 COUNT: 0
B
F:
0
2.00
Under MIX-COUNT mode, all the genuine coins will go to 3
rd
pocket,
foreign coins will go to 1
st
pocket; Under SDC mode, there are
SDC-COUNT and SDC-REJECT. Under SDC-COUNT interface, press
Key to choose the denomination you want to sort. Take Euro coins
for example, you can choose 2.00, 0.50, 1.00, 0.20, 0.05, 0.10, 0.02
and 0.01. Based on the denomination you choose, the same denomination will go to 3rd pocket, other genuine coins will go to 2
nd
pocket and foreign coins will be sorted into 1
st
pocket
SDC- REJECT STOP
VALUE: 0.00 COUNT: 0
B
F:
0
2.00
Under SDC-REJECT interface, press key to choose the
denomination you want to sort, take Euro coins for example, you can
choose 2.00, 0.50, 1.00, 0.20, 0.05, 0.10, 0.02 and 0.01. Based on the denomination you choose, the same denomination will go to 2
nd
pocket, other genuine coins will go to 3
rd
pocket, and foreign coins will
be sorted into 1
st
pocket.
Data Clear:
·Under main modes interface, press CLR key to clear all counted data.
·Under main modes interface, press ESC key to clear rejected coin
record.
Data Memory:
CS-311S Operation Manual V1.2
Page 10 of 17
·Under main interface,press M+Key to save the quantity and amount for genuine coins.It saves the accumulated data of the counting results Under main interface, when the counting quantity and amount for genuine coins is 0, you can press M+ key to clear the saved data.
Data Memory Read:
·Under main modes interface, press MR key to read stored data;
·Under self-learning interface, press M+ Key to read the original
self-learning data, this function is only available for maintenance
people.
9. Function Settings:
Press SET key to enter into Menu interface, shown as follows:
MENU
4.TOTAL
2.VALUE
5.TEST
6.LEARN
3.SYSTEM
>
1.BATCH
Directly press four keys to choose target submenu
and then press SET key to enter each into detailed operation interface: (1) BATCH
BATCH SET
VALUE:
CHANNEL:
0000
BATCH:
1
2.00
Enter into BATCH SET interfacepress key to switch the
channel.Under one channel, pressSET keythe BATCH will flash, at
this moment you can set the BATCH value through the numeric key
0 ~ 9the upper limit is 9999)。 Press CLRkey you can clear the
BATCH setting.
CS-311S Operation Manual V1.2
Page 11 of 17
NOTESThe above steps are used for setting the BATCH number.
If you need to set the BATCH, you need to turn on the BATCH
function in system. Under main interface, press key to turn on
the BATCH on/off. When BATCH function is on, there is a B shown
at the left corner; if there is no B, it means the BATCH function is
turned off.
When one channel Batch No. setting is finished, you can come
back to channel number selection interface by pressing SET key and
then repeat the above number setting way to set batch number for
other target channels. After all settings are finished, press ESC key to
quit from BATCH submenu to come back into main menu interface.
When the machine reaches set Batch number, the LCD display will
show as follows:
MIX- COUNT STOP
VALUE: 20.00 COUNT: 10
F:
2
B
2.00 BATCH OK
For example, if you batch 10pcs for 2.00, when the quantity
reaches 10pcs for 2.00, the machine will stop and show 2.00 BATCH
OK”and flash. At this moment, you need to clear the drawer for 2.00
and press CLR to clear the message, otherwise other key functions are
not workable.
(2) VALUE
VALUE SET
VALUE:
CHANNEL:
1
2.00
Under VALUE interfacepress key to switch the
channel. Under one channel, press SET key to fix the VALUE setting
CS-311S Operation Manual V1.2
Page 12 of 17
mode, the VALUE will flash. At this moment, you can change the value
of this channel through pressing numeric key 0 ~ 9. Press
CLRkeythe setted the value can be cleared to be 0
Notes: The value is already set in the factory and the function is
locked so the user can not change the value.
When one channel Value No. setting is finished, you can come
back to channel number selection interface by pressing SET key and
then repeat the above number setting way to set value number for
other target channels. After all settings are finished, press ESC key to
quit from VALUE submenu to come back into main menu interface.
(3) SYSTEM
SYSTEM SET
5.MAGNET
4.PRINT
1.TIME
>
2.BUZZER
3.POINT
Firstly, it will enter into SYSTEM SET submenu, press or
key to make the cursor up and down. And then press SET key to enter
different setting interface.
1)TIME
>DATE2013-08-29
TIME 05:44:32
Under this interface, if you need to update date and time, please
firstly press SET key to make the cursor blinking and then by press
key to make the cursor moving. Directly press 0~9 numeric key
to set your desired date and time. Press CLR key to clear data. After
all settings are finished, press ESC key to return to main menu
interface.
CS-311S Operation Manual V1.2
Page 13 of 17
2)BUZZER
BUZZERON
Under this interface, please press or key to turn ON/OFF
this function. After setting, press ESC key to return to main menu
interface.
3)POINT
POINTON
Under this interface, please press or key to turn ON/OFF
this function. After setting, press ESC key to return to main menu
interface.
4)PRINT
>PRINT0
ON
9600
BAUD
Under this interface, please press or key to choose
PRINT 0 or set BAUD rate. Press SET key to choose either one, and
then press or key to turn ON/OFF the function. After setting,
press ESC key to return to main menu interface.
5)MAGNET
CS-311S Operation Manual V1.2
Page 14 of 17
>MAGNET1: 4 ms
MAGNET2: 5 ms MAGNET3: 6 ms
Under this interface, please press or key to choose
MAGNET 1,2, or 3, and then press SET key to set solenoid activation
time(suggested range is 3~9ms). By press or key, the time
will be increased or decreased. After setting, press ESC key to return
to main menu interface.
Notes: MAGNET 2 AND MAGNET 3 are reserved in software and
user does not need to set it
(4) TOTAL
TOTAL:
0000017331
This interface shows a memory record of all counted coin quantity.
You can press ESC key to quit from this TOTAL submenu to come back
into main menu interface.
(5) TEST
This submenu is for production adjustments purpose only. It is not
available for users.
(6) LEARN
This submenu is for coin self-learning parameter tests and
adjustments. It is not available for users.
CS-311S Operation Manual V1.2
Page 15 of 17
10. Trouble Shooting
During self-testing or machine working status, sometimes the LCD
screen may display following error code:
1ERROR ADJUST
CHECK THE SENSOR 0
ERROR:
ADJUST
·When it display ERROR ADJUST, it means the signal of alloy sensor is
abnormal, the self-test can not be done normally, please contact your
local distributor for solution.
2ERROR 01
CHECK THE SENSOR 1
ERROR:
01
·When it displays ERROR 01, it means the IR transistor is blocked,
please check the IR transistor and also the connecting cable. After the
problem is solved, please press CLR key to enter into main interface.
If the problem can not be solved, please contact your local distributor
for solution.
Notes: If there are any foreign things get jammed on the rail, the
dropped coins may not be counted, which will cause counting
mistake. Therefore, please clean all coins by moving foreign things
before sorting.
11. Precautions:
·Power line using the machine configuration.
·Unplug the power cord before moving the machine.
·Avoid operation under direct sunlight.
CS-311S Operation Manual V1.2
Page 16 of 17
·Do not put your hands, tools and clothes into the hopper to avoid
personal injury or malfunction of the machine.
·Don’t open the Visible Cover during operation.
12. Daily Maintenance
·Be sure to unplug the power cord before daily maintenance.
·Please clean the rail and side board at least once a day .
·Clean the disc and hopper at least once a day with a brush.
·
If the machine needs maintenance or spare parts, please contact
the local supplier.
13. Accessories
1. Power Cable 1pc
2. Nylon Brush 1pc
3. Coin Scoop 1pc
4. Turn brushChoose to use 1pc
CS-311S Operation Manual V1.2
Page 17 of 17
*** In the interests of our ongoing policy of continual product improvement,