6L Oil-less Air Compressor 53103

Operating Instructions
Please read and save these instructions before attempting to assemble, install, operate or maintain
the product. Protect yourself and others by observing all safety information. Failure to comply with
instructions could result in injury and/or damage!
DESCRIPTION
Oil-less compressors are designed for DIY
(do-it-yourselfers) for a variety of home uses
and operate without oil. Compressed air
units contain moisture, therefore ensure you
install a water filter or air dryer if your
application requires dry air.
SAFETY GUIDELINES
This manual contains useful information for
the safe use and maintenance of your
compressor. Please observe any of the
safety recommendations.
UNPACKING
After unpacking the unit, carefully inspect it
for any damage that may have occurred
during transit. If you have any concerns
please contact your supplier prior to use.
GENERAL SAFETY INFO
Air compressors and tools (spray guns,
filters, lubricators, hoses, etc.) produce and
require compressed air for them to operate.
Ensure to:-
1. Read all tool
manuals and be
thoroughly familiar
with the controls and
the proper use of the equipment.
2. Keep visitors away and NEVER allow
children in the work
area.
3. Wear safety glasses
and use ear protection..
4. Do not stand on or
operate the unit whilst handheld from the
handle.
5. Prior to each use inspect the air system
and electrical components for signs of
damage, deterioration, weakness or
leakage, Repair or replace defective items
before using.
6. ▲WARNING!
Never operate or repair
in or near a flammable
gas or vapor. Never store flammable
liquids or gases in the vicinity of the
compressor.
7. ▲CAUTION!
Compressor parts may be
hot even if the unit is
stopped.
8. ▲WARNING!
Never remove or attempt to adjust the
pressure release valve. Ensure it is kept
clean and free from any contamination.
9. ▲DANGER!
Never attempt to repair or
modify a tank! Welding or
any modification may weaken the tank
resulting in damage, rupture or
explosion. Always replace a worn or
damaged tank.
10. ▲WARNING!
Tanks rust from moisture build-up,
which weakens the tank. Make sure to
drain tank regularly and inspect
periodically for unsafe conditions such
as rust formation and corrosion.

12. LOCATION
It is extremely important to install the
compressor in a clean, well-ventilated area.
The surrounding air temperature should not
be more than 100°F.
A minimum clearance of 18 inches between
the compressor, a wall or any other obstacle
is required so as not to obstruct the airflow to
the unit.
13. ▲CAUTION!
Never use an extension
cord with this product.
Use additional air hose to reach your
work area, this is to avoid power loss
and possible motor damage; Use of an
extension cord voids the warranty.
14. OPERATION
a) The red button on top of the pressure
switch is the main ON/OFF control. With
the button pressed down the compressor
will operate and fill the tank with air. Once it
has reached capacity it will automatically
switch off. In the position the compressor
will automatically switch on and off to keep
the tank filled with air. To switch OFF the
compressor pull the red button in an
upward direction.
b) The regulator controls the amount of air
pressure required. Turning the regulator
clockwise increases the pressure,
anticlockwise decreases the pressure to
the required level for the tool being used.
c) The safety valve automatically releases air
if the tank pressure exceeds the preset
maximum.
d) Ensure the compressor has had time to
fill the tank and warm up prior to initial use.
e) The tank pressure gauge shows
pressure level in the tank.
f) ▲CAUTION!
The compressor is equipped with an
automatic reset thermal overload
protector; this will shut off the motor if it
becomes overheated. If the thermal
overload is activated turn off the
compressor and unplug from the mains.
The motor must be allowed to cool
down before start-up is possible.

1. No electrical power
2. Blown fuse
3. Breaker open
4. Thermal overload open
5. Pressure switch bad
1. Plugged in? Check fuse/breaker or motor
overload
2. Replace blown fuse
3. Reset, determine cause of problem
4. Motor will restart when cool
5. Replace
Motor hums but cannot
run or runs slowly
1. Defective check valve
or unloaded
2. Poor contacts, line
voltage low
Shorted or open motor
winding
1. Replace or repair
2. Check connections, eliminate extension cork if
used, check circuit with voltmeter
3. Replace motor
DANGER! Do not disassemble check valve with
air in tank; bleed tank
Fuses blow/circuit
breaker trips repeatedly
CAUTION! Never use an
extension cord with this
product
1. Incorrect size fuse,
circuit overloaded
3. Defective check valve
or unloaded
1. Check for proper fuse, use time-delay fuse.
Disconnect other electrical appliances from circuit or
operate compressor on its own branch circuit
2.Replace or repair
DANGER! Do not disassemble check valve with
air in tank; bleed tank
Thermal overload
protector cuts out
repeatedly
1. Low voltage
2. Clogged air filter
3. Lack of proper
ventilation/room
temperature too high
4. Check valve
malfunction
2. Compressor valves
failed
1. Eliminate extension cord, check with voltmeter
2. Clean filter (see Maintenance section)
3. Move compressor to well-ventilated area
4. Replace
5. Replace valve assembly
DANGER! Do not disassemble check valve with
air in tank; bleed tank
Knocks, rattles, excessive
vibration
1. Loose bolts, tank not
level
2. Defective bearing on
eccentric or motor shaft
5. Cylinder or piston ring
is worn or scored
1. Tighten bolts, shim tank to level position
2. Replace
Replace or repair as necessary
Tank pressure drops
when compressor shuts
off
1. Loose drain cock
2. Check valve leaking
3. Loose connections at
pressure switch or
regulator
1. Tighten
2. Disassemble check valve assembly, clean or
replace
3. Check all connections with soap and water
solution and tighten
3.
Compressor runs
continuously and air
output is lower than
normal/low discharge
pressure
1. Excessive air usage,
compressor too small
2. Clogged intake filter
3. Air leaks in piping (on
machine or in outside
system)
4. Broken inlet valves
Piston ring worn
1. Decrease usage or purchase unit with higher air
delivery (CFM)
2. Clean or replace
3. Replace leaking components or tighten as
necessary
4. Replace compressor valves
Replace piston and cylinder
Excessive moisture in
discharge air
1. Excessive water in tank
3. High humidity
1. Drain tank
2. Move to area of less humidity; use airline filter
NOTE: Water condensation is not caused by
compressor malfunction
Compressor runs
continuously and safety
valve opens as pressure
rises
1. Defective pressure
switch
5. Defective safety valve
1. Replace switch
5. Replace safety valve with genuine replacement
part
Excessive starting and
stopping (auto start)
2. Excessive
condensation in tank
Air leaking from unloader
on pressure switch
2. Check valve stuck in an
open position
Remove and replace check valve
2. DANGER! Do not disassemble check valve
with air in tank; bleed tank

1 6 valve plate subassembly

Customer care Line:- 01568 620444
GUARANTEE
This product has been manufactured to high quality standards and is guaranteed against manufacturing faults for a
period of 12 months from the date of purchase. Normal wear and tear, including accessory wear, is not covered under
the guarantee. This guarantee is invalid if the compressor has been overloaded or subjected to neglect, improper use
or an attempted repair other than by an authorised agent. This product is not sold for commercial, heavy duty,
professional or hire use any such uses voids any guarantee.
DECLARATION OF CONFORMITY
The following product is covered by this declaration:-
Manufacturers model No:ZBW60-6 - Rhyas Product Code 53103
Tested to EN 1012-1:1996 covering the following EU Directives:-
EN 60204-1:2006 + A1:2009
LVD (2006/95/EC)
2006/42/EC - Machinery Directive
The documentation required to demonstrate the above are available for inspection.
The CE mark was first applied in 2010.
Signed: A M Riga
Authority: Director
Date: April 2014
Rhyas Products, Leominster. HR6 0QF. England.
UK. Subject to change.
Document Ref: 6Ltr Air Compressor 53103