F). FAQ......................................................................................
10
A). Product Features
Main board adopts Philips CPU microcomputer chip-level design
Optional unlocking ways (fingerprint, password, keys)
B). Technology Specification
Capacity of Passwords
100 Groups
Capacity of admin passwords
1 Groups
Capacity of fingerprint
100pcs
Power Supply
DC4.5V6.5V4pcs of 1.5 No. 5 AA alkaline batteries
Static Current
< 30uA
Dynamic Current
< 150uA
Low power warning
It will be warning and lighting notice when power voltage is below 4.8V.
Executive body
DC micro motor
Service life
Be used for more than 300,000 times
C). Operation
Note: Before using, you should firstly waken up the panel by touching it by your palm (please
see picture). The correct way to waken up the panel is to try as many fingers as possible to
touch the screen. After wakening up the panel, you can login the password or read the
fingerprint to open the lock.
The original unlocking password is “123456”+”#”
The original management password is “0000” (management password can’t be used to open
the lock)
1. Change the management password.
* (for 2s) + 7 + management passwords + # + new management passwords + #.
Settings finish.
Remarks: New management password will replace the old one.
1 2
2. To add new passwords and fingerprints
To add new user passwords:
* (for 2s) + 8 + management passwords + # + new passwords + # ......
Remarks: It can add 100 groups of user passwords
To add fingerprints:
“*” (for 2s) + “8”+ management password + “#” + first new fingerprint (for 4 times) +
second new fingerprint (for 4 times) + third new fingerprint (for 4 times) + ......
(It can continuously add 100 pieces of fingerprints)+ “#” to exit. Setting finished. Original
passwords can not work after fingerprint added.
Note: it will quit automatically after 6s.
3
3. To delete passwords and fingerprints
To delete a group of passwords
* (for 2s) + 9 + management passwords + # + user password + #
Note: it will quit automatically after 6s.
To delete all passwords by one time: “*”(for 2s) + “0”+ management password + “#” (see picture 3) + “8” + “#”
3
4
To delete all fingerprints by one time: “*” (for 2s) + “0”+ management password + “#” (see picture 3) + “9” + “#”
4. Setting for Modes
Mode (1): To unlock by password or fingerprint - under this mode, you can open the lock
either by password or fingerprint
“*” (for 2s) + “0”+ management password + “#” (see picture 3) + “1” + “#”
Mode (2): To unlock by password + fingerprint - under this mode, you can open the lock only when
you login the password and read the fingerprint.
“*” (for 2s) + “0”+ management password + “#” (see picture 3) + “2” + “#”
Note: the original mode is Mode 1.
5. To clean all data and return to the original setting
“*” (for 2s) + “0”+ management password + “#”(see picture 3) + “0” + “#”
5 6
D). Installation Drawing of 117C99-C
6. Others:
A. When login incorrect passwords continuously for more than 4 times, the lock will alarm
whistle for 10 times. When login incorrect passwords continuously for more than 7 times, it will
alarm whistle for 10 times and the keyboard will be locked in for 1 minute without reaction.
B. To clean all data and return to to original setting: open the battery cover, press the snap (ADEL)
for 3s , the red light will be turned on, then it will begin a long ring and the system will return all
data back to the original factory setting -- internal storage passwords will be cleaned up; And the
management password will be renewed to “0000”, user passwords return to “123456”, any user
fingerprints can unlock, with normally open; The work mode is mode 1. Add new user fingerprints
and user passwords according to previous instructions.
No.
Name
Quantity
1
Front plate
1
2
Back plate
1
3
Locker
1
4
Back Mat
1
5
Battery Box Cover
2
6
Cylinder (with key)
1
7
Back square spindle
1
8
Front square spindle
1
9
Spring of square spindle
2
10
Strike plate case
1
11
Strike plate
1
12
Screw for lock body
7
13
Screw for cylinder
1
14
M5X12 tapping screw
1
15
M5X12 recessed screw
2
16
M5X35 Semi-tapping Screw
2
7 8
E). Drilling-bore Drawing F). FAQ
This hole map is only suitable for wood door. (Lock body without lock rod )
Problem
Reason
Proposed
Solution
This hole map is only suitable for metal door. (Lock body with lock rod)
9 10