Please read this booklet carefully and keep it in a safe place for
your future reference.
Edition: A (March 2012) - 1 -
Under-Counter Beverage Cooler
Thank you for selecting a Rhino product. This appliance has been
designed using the latest techniques and incorporates the best
components. We hope that you enjoy its use and benefit from its
performance. Please read this manual carefully and keep it in a
safe place for future reference
IMPORTANT
In the event of a breakdown, please consult the re-seller from
whom you purchased this merchandiser
Always insist upon the use of Rhino genuine parts.
For further information please contact:
The information within this booklet was correct at the time of printing.
Specifications and information may alter without notice
Edition: A (March 2012) - 3 -
Under-Counter Beverage Cooler
1. INSTALLATION
1.1 Safety information
All electrical work must be carried out by suitably qualified persons
When using any electrical appliance, safety precautions should always be
observed.
• Do NOT use this appliance for other than its intended use. This product is
intended for use as a beverage cooler. It is not suitable for the storage of
foodstuffs.
• When used by, or near, young children or infirm persons, close supervision is
necessary. Young children should be supervised at all times to ensure that
they do not play with this appliance.
• Do NOT cover the front grille or block the rear air entry by placing object up
against the cabinet.
• Ensure adequate ventilation.
• Do NOT probe any openings.
• Be careful not to touch any moving parts or hot surfaces.
• Regulations require that all electrical work be carried out by authorized
persons. For your own safety and that of others please ensure this is done.
• Do NOT overload the power supply. Always ensure that the power supply is
adequate for the electrical requirements specified on the rating label. The
rating label is located inside the merchandiser on the right hand side wall. If in
doubt, please consult a qualified electrician. Caution: Never use extension
leads or multiple adaptors.
• If the mains supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified and skilled persons in order to avoid
hazard. A skilled person is a person having the appropriate technical training
and experience necessary to be aware of hazards to which he or she is
exposed in performing a task and of measures necessary to minimize the
danger to his or herself or other persons.
• Disconnect the mains power supply before attempting any cleaning, removal
of any covers, or maintenance work.
• Do NOT store explosive substances, such as aerosol cans with flammable
propellant, in this merchandiser.
·WARNING: Do not use mechanical devices or other means to accelerate the
defrosting process. Defrosting is performed automatically.
Edition: A (March 2012) - 4 -
Under-Counter Beverage Cooler
·WARNING:Do not damage the refrigeration circuit.
·WARNING: Do not use electrical appliances inside the storage comp artment
of this appliance.
1.2 Assembly
·Remove the appliance from the packaging and peel off any protective film
from all surfaces.
·Fit the shelf support clips onto the shelf support strips, making sure that the
clips for each shelf are of the same height and that they are securely engaged
on the support strip.
·Unwrap each shelf carefully, to prevent damaging their protective coating or
surface finish.
·Position the shelves onto the clips.
·Please note the following maximum shelf loading weights:20Kg.
Edition: A (March 2012) - 5 -
Under-Counter Beverage Cooler
1.3 Positioning the chiller
·Please position the cabinet carefully being careful not to bump it.
·The power supply flex exits the chiller at the bottom right hand side (as
viewed from the front). For ease of access, the flex should be retrieved prior to
positioning the chiller in its final location.
·The maximum recommended ambient temperature for this chiller is 42℃.
·Avoid positioning the appliance in direct sunlight or damp areas.
·Allow adequate space for the door(s) to fully open.
·Ensure that this chiller is positioned on a level surface, so as to allow the
door(s) to shut and seal correctly, as well as to allow proper drainage from the
evaporator tray, to prevent any overflow. If necessary, adjust the screw feet of
the appliance to make it level.
·Do NOT overload the power supply. Always ensure that the power supply is
adequate for the electrical requirements specified on the rating label. The
rating label is located inside the chiller, on the right hand side wall. If in doubt,
please consult a qualified electrician. Caution: Never use extension leads or
multiple adaptors.
Note: If the unit has not been stored or moved in an upright position, let it stand
upright for approximately 12 hours before operation. If in doubt allow to stand.
Ventilation
·All models: All models must have clear and unobstructed ventilation from the
entire surface area of the front grille.
·The 2 and 3 door models may be built into an enclosure without the need for
ventilation other than at the front.
·The single door coolers MUST have a minimum ventilation space of 20mm at
sides and rear.
·WARNING:
Failure to provide the minimum ventilation space will
harm the performance of your chiller, could cause fire and will invalidate the
warranty.
·WARNING: Keep clear of obstruction all ventilation openings in the
appliance enclosure or in the structure for building in.
Edition: A (March 2012) - 6 -
Under-Counter Beverage Cooler
2. Product description
Series Model No Door’s qualityDoor’s type
GSP0H-840 Single door Hinged door 1×2Watt(Max.) LED light
GSP1H-840 Single door Hinged door 1×2Watt(Max.) LED light
GSP2H-840 Double door Hinged door 2×2Watt(Max.) LED light
GSP2S-840 Double door Sliding door 2×2Watt(Max.) LED light
GSP3H-840 Triple door Hinged door 3×2Watt(Max.) LED light
GSP3S-840 Triple door Sliding door 3×2Watt(Max.) LED light
GSP0H-865 Single door Hinged door 1×2Watt(Max.) LED light
GSP1H-865 Single door Hinged door 1×2Watt(Max.) LED light
GSP2H-865 Double door Hinged door 2×2Watt(Max.) LED light
GSP2S-865 Double door Sliding door 2×2Watt(Max.) LED light
GSP3H-865 Triple door Hinged door 3×2Watt(Max.) LED light
GSP3S-865 Triple door Sliding door 3×2Watt(Max.) LED light
GSP0H-900 Single door Hinged door 1×2Watt(Max.) LED light
GSP1H-900 Single door Hinged door 1×2Watt(Max.) LED light
GSP2H-900 Double door Hinged door 2×2Watt(Max.) LED light
Lighting
GSP2S-900 Double door Sliding door 2×2Watt(Max.) LED light
GSP3H-900 Triple door Hinged door 3×2Watt(Max.) LED light
GSP3S-900 Triple door Sliding door 3×2Watt(Max.) LED light
3. Pack contents
The following is included:
All models
·RHINO Back Bar Chiller ·Instruction manual ·2 keys for glass door
Plus…
Single Door model
·2 adjustable shelves ·8 shelf support clips
Double Door model
·4 adjustable shelves ·16 shelf support clips
Triple Door model
·6 adjustable shelves ·24 shelf support clips
RHINO prides itself on quality and service, ensuring that at the time of
packaging the contents are supplied fully functional and free of damage.
Should you find any damage as a result of transit, please contact your RHINO
dealer immediately.
Edition: A (March 2012) - 7 -
Under-Counter Beverage Cooler
4. Operation
This chiller is designed to operate at a recommended ambient temperature of
42℃ and as such, is categorized as a Climate Class 5 product. This
information is recorded on the rating label, which can be found on the inside
right hand wall of the cabinet.
Climate class Temperature(℃) Humidity(%RH)
5 40 40
Control Panel
The control panel is located below the door(s) on the front of the appliance.
Switching on
·Close the door of the appliance.
·Connect the appliance to an appropriate mains power supply.
Working mode
There are two different modes for the electronic thermostat, which are referred
to as Standard Mode and Saving Mode.
·Standard Mode: the chiller is optimised for maximum performance and will
maintain 0-4C.
·Saving Mode: the chiller is optimised for energy saving. In Saving Mode the
interior temperature is allowed to rise to as high as 10C, the air circulating fans
are managed for energy saving and the interior lights are switched off.
Switching Between Modes
When the appliance is powered up for the first time, the default mode is
Standard Mode. To enter Saving Mode, simply press and hold the UP/ES
keypad button for at least 3 seconds. The mode which is about to be entered is
displayed as a preview. EnS is displayed for Saving Mode and NOR is
displayed for Standard Mode. Upon disconnection and subsequent
re-connection to the mains power, the previously selected mode will be
remembered and restored.
Switching the Interior Lights ON and OFF
As mentioned above, the lights are automatically turned off in “Saving Mode”.
To switch the interior lights on or off at any time in either Mode, simply press
Edition: A (March 2012) - 8 -
Under-Counter Beverage Cooler
and hold the DOWN / LIGHT keypad button for at least 0.5 seconds. The light
will be either powered on or off accordingly.
If the compressor light is flashing on the electronic display
The compressor is designed to have a minimum resting period of 6 minutes. If
the electronics command the compressor to start, but it is in resting mode, then
the compressor light will flash. This is normal and nothing to be concerned
about.
Adjusting the temperature of Standard Mode
The appliance is set up to run without interference from the user. It is not
recommended for the user to interfere with the complex electronic set up.
However if the user wishes to change the temperature of the Standard Mode
then it can be done by altering the ST parameter. ST is the lowest temperature
that the user wishes the appliance to run at. The appliance will run at ST plus 2
degrees. For example if you wish to have an average temperature of 6
degrees inside the cabinet then you would select ST at a value of 4:
1. Press the SET keypad button for at least 3 seconds until “ 0 “ is
displayed.
2. Press the UP / ES keypad button 22 times until “ 22 “ is displayed .
3. Press the SET keypad button and the display will change to “PS”
4. Press the UP / ES keypad button 7 times until “ ST “ is displayed.
5. “ 0 “ will appear on the display
6. Using the “Down/Light” or “Up / ES” button, select the ST minimum
temperature value you prefer.
7. Press the “SET” keypad button once again will lock in the parameter
change.
Edition: A (March 2012) - 9 -