Rheem Value Series Single Stage Submittal Sheet

JOB NAME LOCATION
CONTRACTOR ORDER NO.
ENGINEER UNIT MODEL NO.
SUBMITTED FOR APPROVAL RECORD COIL MODEL NO.
DATE AIR HANDLER MODEL NO.
SUBMITTAL SHEET FOR 14AJM SERIES
1.5 TO 5 NOMINAL TON [5.28 TO 17.58 kW], 14.5 SEER CONDENSING UNITS
Supersedes Form No. X66-1280 Rev. 1
Low Pressure Control....................................................
High Pressure Control ........................................................
Low Ambient Control ..........................................................
Compressor Time Delay Control ........................................
Crankcase Heater ........................................................
Sound Enclosure ................................................................
FIELD INSTALLED ACCESSORIES
FEATURES FOR 14AJM SERIES
CONDENSING UNITS
1.5 TO 5 NOMINAL TON [5.28 TO 17.58 kW]
• Painted louvered steel cabinet
• Easily accessible control box
• Grille/motor mount for quiet fan operation
• Condenser coils constructed with copper tubing and enhanced aluminum fins
• Filter Drier (shipped–not installed)
• Certified and rated under AHRI Standard 210
• U.L. listed
• Factory limited warranty on parts as follows:
Conditional Parts*
(Registration Required) ............................Ten (10) Years
Condenser Coil leaks caused by
factory defects............................................Five (5) Years
Conditional Compressor*
(Registration Required) ............................Ten (10) Years
Any Other Part ..............................................Five (5) Years
*See Product Warranty Card for Details.
UNIT DATA
COOLING PERFORMANCE
EFFICIENCY ................................
_______
SEER
TOTAL CAPACITY*..................
_______
MBH [kW]
SENSIBLE CAPACITY*............
_______
MBH [kW]
OUTDOOR DESIGN TEMP. ....
_______
°F [°C] DB
TEMP. OF AIR ENTERING
EVAPORATOR COIL............
_______
°F [°C] DB
_______
°F [°C] WB
POWER INPUT REQUIREMENT ........
_______
kW
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT......................................
_______
IWG
BLOWER SPEED ..........................
_______
RPM
POWER OUTPUT REQUIREMENT ..
_______
BHP
MOTOR RATING ........................
_______
HP [W]
POWER INPUT REQUIREMENT ........
_______
kW
ELECTRICAL DATA
POWER SUPPLY ........................
___________Hz
TOTAL UNIT AMPACITY................
_______
AMPS
MINIMUM WIRE SIZE ....................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ..........
_______
AMPS
CLEARANCES
ACCESS SIDE 24" [609.6 mm]
AIR INLETS 6" [152.4 mm]
ABOVE UNIT 60" [1524 mm]
Featuring Industry Standard R-410A Refrigerant
“Proper sizing and installation of equipment is critical to achieve optimal performance.
Split system air conditioners and heat pumps must be matched with appropriate coil components
to meet ENERGY STAR criteria. Ask your Contractor for details or visit www.energystar.gov.”
“In keeping with its policy of continuous progress and product improvement, Manufacturer reserves the right to make changes without notice.”
PRINTED IN U.S.A. 4-10 DC FORM NO. X66-1280 REV. 2
Supersedes Form No. X66-1280 Rev. 1
14AJM 18, 24, 30, 36, 42, 48, 49, 56, 60
Full Metal Jacket
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
[ ] Designates Metric Conversions
L
H
w
SEE DETAIL A
Model No.
14AJM
Width “W”
Inches [mm]
Unit Dimensions
Length “L”
Inches [mm]
Height “H”
Inches [mm]
18, 24, 30 315/8 [803] 315/8 [803] 273/8 [695]
36, 42, 48, 49, 56, 60 315/8 [803] 315/8 [803] 353/8 [899]