FEATURES FOR RGPS-
• Unique solid door design leads to quiet operation.
• Patented heat exchanger, constructed of both stainless and
aluminized steel for the maximum in corrosion resistance.
• Low profile “34 inch” [864 mm] design is lighter and easier to
handle, and leaves room for optional equipment.
• Convertible from upflow to horizontal left or right without field
conversion.
• Left or right side gas and electric inlet connections allow quick
and simple change.
• Direct spark ignition with remote sense, features a new
integrated board with an electronic air cleaner hookup.
• A slow-open gas valve and a specially designed draft inducer
motor make it one of the quietest furnaces on the market
today.
• Grab-holes in doors to aid in easy door removal and
replacement.
• Prepaint galvanized steel cabinet.
✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test
procedures.
FIELD INSTALLED ACCESSORIES
Internal Filter Rack for Bottom or Side Return (RXGF-DA*) ....
Side Return Filter Rack (RXGF-CA) ........................................
Bottom Return Filter Rack for Upflow Application (RXGF-CB)
Twinning Kit (RXGP-F03)..........................................................
Fossil Fuel Kit (RXPF-F01 and F02) ........................................
Return Air Cabinets (RXGR-C**B)............................................
Solid Bottom Kit (RXGB-D14, 17, 21, 24) ................................
FORM NO. X66-1255 REV. 1
Supersedes Form No. X66-1255
JOB NAME MODEL NO.
CONTRACTOR OUTDOOR UNIT MODEL NO.
ENGINEER LOCATION
SUBMITTED FOR APPROVAL RECORD ORDER NO.
DATE
SUBMITTAL SHEET FOR RGPS80% A.F.U.E.
✝
UPFLOW/HORIZONTAL GAS FURNACES
Models with Input Rates from 50,000 to 150,000 BTU/HR
[15 to 44 kW].
UNIT DATA
HEATING PERFORMANCE
TOTAL CAPACITY INPUT* ......
_______
MBH [kW]
TOTAL CAPACITY OUTPUT* ..
_______
MBH [kW]
DESIGN TEMP. RISE ..............
_______
°F [°C] DB
AFUE ................................................
_______
%
CALIFORNIA SEASONAL
EFFICIENCY ..................................
_______
%
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT......................................
_______
IWG
BLOWER SPEED ..........................
_______
RPM
POWER OUTPUT REQUIREMENT ..
_______
BHP
MOTOR RATING ........................
_______
HP [W]
POWER INPUT REQUIREMENT ........
_______
kW
ELECTRICAL DATA
POWER SUPPLY ........................
__________ Hz
TOTAL UNIT AMPACITY................
_______
AMPS
MINIMUM WIRE SIZE ....................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ..........
_______
AMPS