Rheem Value Series 2-Stage Specification

Rheem Value Series Two-Stage Air Conditioners
FORM NO. A11-210
16AJL- Series
Efficiencies up to 16 SEER/13 EER Nominal Sizes 2-5 Ton [7.03 to 17.6 kW] Cooling Capacities 25,400 to 57,000 BTU/H [7.44 to 16.70 kW]
Outdoor air conditioner designed for ground level or rooftop
installations. These units offer comfort and dependability for single, multi-family and light commercial applications.
10 easy-to-read diagnostic alert codes
Painted louvered steel cabinet
Easily accessible control box
Condenser coils constructed with copper tubing and
enhanced aluminum fins (2-4 Tons)/MicroChannel (5 Ton)
Grille/Motor mount for quiet fan operation
Filter Drier (shipped – not installed)
Air
Air Conditioners
16AJL Series
Note: Above image does not show deep drawn basepan.
16.0
Air
Table of Contents
16AJL Series
2
TABLE OF CONTENTS
Model Number Identification ............................................................................3
Accessories....................................................................................................3
Scroll Compressor ..........................................................................................3
Performance Data ......................................................................................4-18
Electrical & Physical Data ..............................................................................19
Unit Dimensions............................................................................................20
Refrigerant Line Size Information ....................................................................21
Limited Warranty ..........................................................................................22
Air
Model I.D./Accessories/Compressor
16AJL Series
3
Model Number Identification
16 A J L 24
NOMINAL COOLING CAPACITY
24 = 24,000 BTU/HR [7.03 kW] 36 = 36,000 BTU/HR [10.55 kW] 48 = 48,000 BTU/HR [14.07 kW] 60 = 60,000 BTU/HR [17.58 kW]
A 01
16 SEER A = AIR CONDITIONER VOLTAGE
J = 208-230
SINGLE PHASE
DESIGN SERIES
L = 1ST DESIGN
R-410A
CABINET
A = FULL METAL JACKET
RHEEM
VALUE
SERIES
Accessories
Low Pressure Control (RXAC-A07)
High Pressure Control (RXAB-A07)
Low Ambient Control (RXAD-A08)
Compressor Time Delay Control
Crankcase Heater
Sound Enclosure
* Photos are representative. Actual models may vary.
For detailed thermostat match-up information, see specification sheet form number T11-001.
300-Series *
Deluxe Programmable
400-Series *
Special Applications/ Programmable
500-Series *
Communicating/ Programmable
200-Series *
Programmable
Scroll®Compressor
The reliable scroll compressor is the key to efficiency for this Rheem model. It’s the latest in high-efficiency compressor tech­nology. The advanced scroll compressor offers low noise and vibration characteristics and features tolerance to liquid refrigerant and system contamination. The scroll compressor also has low start torque, reducing start problems in the field. And its unique design enables air conditioners to perform efficiently and quietly.
[ ] Designates Metric Conversions
Thermostats
Air
Performance Data
16AJL Series
4
Outdoor
Unit
16AJL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
24
RCSL-H*2621
RHML-HM2421
1 14400 [4.2] 6800 [2.0]
25400 [7.4] 16 13
525 [248] 0
2 18100 [5.3] 7300 [2.1] 700 [330] 74
1 - dehumid 0 [0.0] 0 [0.0] 0 [0]
2 - dehumid 0 [0.0] 0 [0.0] 0 [0]
RCFL-H*2417
RGFE-06?MCK?
1 14500 [4.2] 6500 [1.9]
24800 [7.3] 15 12.5
575 [271] 0
2 18000 [5.3] 6800 [2.0] 800 [378] 74
RGFG-06?MCK?
1 14500 [4.2] 6500 [1.9]
24800 [7.3] 15 12.5
575 [271] 0
2 18000 [5.3] 6800 [2.0] 800 [378] 74
RGGE-07?MCK?
1 14500 [4.2] 6500 [1.9]
24800 [7.3] 15 12.5
575 [271] 0
2 18000 [5.3] 6800 [2.0] 800 [378] 74
RGJF-07?MCK?
1 14500 [4.2] 6500 [1.9]
24800 [7.3] 15 12.5
575 [271] 0
2 18000 [5.3] 6800 [2.0] 800 [378] 74
RGLE-07?AMK?
1 14700 [4.3] 6500 [1.9]
25000 [7.3] 15 12.5
600 [283] 0
2 18200 [5.3] 6800 [2.0] 800 [378] 74
RGPE-05?BMK?
1 14500 [4.2] 6500 [1.9]
24800 [7.3] 15 12.5
575 [271] 0
2 18000 [5.3] 6800 [2.0] 800 [378] 74
RGRM-04?MAE?
1 14300 [4.2] 6500 [1.9]
24800 [7.3] 15 12.5
575 [271] 0
2 18000 [5.3] 6800 [2.0] 800 [378] 74
ROCA-070E03
1 14700 [4.3] 6500 [1.9]
24800 [7.3] 15 12.5
600 [283] 0
2 18000 [5.3] 6800 [2.0] 800 [378] 74
ROLA-070E03
1 14500 [4.2] 6500 [1.9]
24800 [7.3] 15 12.5
600 [283] 0
2 18000 [5.3] 6800 [2.0] 800 [378] 74
RCFL-H*2417+RXMD-C04 Coil Only
1 13600 [4.0] 6600 [1.9]
23800 [7.0] 14 11.5
525 [248] 0
2 16800 [4.9] 7000 [2.1] 700 [330] 74
RCFL-H*2617
RGFE-06?MCK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGFG-06?MCK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGGE-07?MCK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGJF-07?MCK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGLE-07?AMK?
1 15100 [4.4] 6700 [2.0]
25800 [7.6] 16 13
600 [283] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGPE-05?BMK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGRM-04?MAE?
1 14900 [4.4] 6700 [2.0]
25600 [7.5] 16 13
575 [271] 0
2 18600 [5.4] 7000 [2.1] 800 [378] 74
ROCA-070E03
1 15100 [4.4] 6700 [2.0]
25800 [7.6] 16 13
600 [283] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
ROLA-070E03
1 15100 [4.4] 6700 [2.0]
25800 [7.6] 16 13
600 [283] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RCFL-H*2617+RXMD-C04 Coil Only
1 14000 [4.1] 6800 [2.0]
24800 [7.3] 14.5 12
525 [248] 0
2 17500 [5.1] 7300 [2.1] 700 [330] 74
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
16AJL Series
5
Outdoor
Unit
16AJL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
024
RCFL-H*2621
RGFE-06?MCK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGFG-06?MCK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGGE-07?MCK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGJF-07?MCK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGLE-07?AMK?
1 15100 [4.4] 6700 [2.0]
25800 [7.6] 16 13
600 [283] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGPE-05?BMK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGRM-04?MAE?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
ROCA-070E03
1 15100 [4.4] 6700 [2.0]
25800 [7.6] 16 13
600 [283] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
ROLA-070E03
1 15100 [4.4] 6700 [2.0]
25800 [7.6] 16 13
600 [283] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RCFL-H*2621+RXMD-C04 Coil Only
1 14000 [4.1] 6800 [2.0]
24800 [7.3] 14.5 12
525 [248] 0
2 17500 [5.1] 7300 [2.1] 700 [330] 74
RCFN-H*2417
RGFE-06?MCK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGFG-06?MCK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGGE-07?MCK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGJF-07?MCK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGLE-07?AMK?
1 15100 [4.4] 6700 [2.0]
25800 [7.6] 16 13
600 [283] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGPE-05?BMK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGRM-04?MAE?
1 14900 [4.4] 6700 [2.0]
25600 [7.5] 16 13
575 [271] 0
2 18600 [5.4] 7000 [2.1] 800 [378] 74
ROCA-070E03
1 15100 [4.4] 6700 [2.0]
25800 [7.6] 16 13
600 [283] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
ROLA-070E03
1 15100 [4.4] 6700 [2.0]
25800 [7.6] 16 13
600 [283] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RCFN-H*2417+RXMD-C04 Coil Only
1 14000 [4.1] 6800 [2.0]
24800 [7.3] 14.5 12
525 [248] 0
2 17500 [5.1] 7300 [2.1] 700 [330] 74
RCFN-H*2421
RGFE-06?MCK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGFG-06?MCK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
16AJL Series
6
Outdoor
Unit
16AJL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
24
RCFN-H*2421
RGGE-07?MCK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGJF-07?MCK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGLE-07?AMK?
1 15100 [4.4] 6700 [2.0]
25800 [7.6] 16 13
600 [283] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGPE-05?BMK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGRM-04?MAE?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
ROCA-070E03
1 15100 [4.4] 6700 [2.0]
25800 [7.6] 16 13
600 [283] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
ROLA-070E03
1 15100 [4.4] 6700 [2.0]
25800 [7.6] 16 13
600 [283] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RCFN-H*2421+RXMD-C04 Coil Only
1 14000 [4.1] 6800 [2.0]
24800 [7.3] 14.5 12
525 [248] 0
2 17500 [5.1] 7300 [2.1] 700 [330] 74
RCSL-H*2621 RHPL-HM2421
1 14700 [4.3] 6500 [1.9]
25000 [7.3] 16 13
600 [283] 0
2 18200 [5.3] 6800 [2.0] 800 [378] 74
RCSN-H*2421 RHPN-HM2421
1 14900 [4.4] 6700 [2.0]
26000 [7.6] 16 13
575 [271] 0
2 19000 [5.6] 7000 [2.1] 800 [378] 74
36
RCSL-H*3821
RHML-HM3621
1 19500 [5.7] 9100 [2.7]
35400 [10.4] 16 13
800 [378] 0
2 24500 [7.2] 10900 [3.2] 1050 [495] 77
1 - dehumid 0 [0.0] 0 [0.0] 0 [0]
2 - dehumid 0 [0.0] 0 [0.0] 0 [0]
RCFL-H*3617
RGFE-06?MCK?
1 18400 [5.4] 9000 [2.6]
34400 [10.1] 14.5 12
725 [342] 0
2 23400 [6.9] 11000 [3.2] 1000 [472] 77
RGFE-07?MCK?
1 18400 [5.4] 9000 [2.6]
34600 [10.1] 14.5 12
725 [342] 0
2 23800 [7.0] 10800 [3.2] 1025 [484] 77
RGFG-06?MCK?
1 18400 [5.4] 9000 [2.6]
34400 [10.1] 14.5 12
725 [342] 0
2 23400 [6.9] 11000 [3.2] 1000 [472] 77
RGFG-07?MCK?
1 19200 [5.6] 8800 [2.6]
34200 [10.0] 14.5 12
800 [378] 0
2 23200 [6.8] 11000 [3.2] 1000 [472] 77
RGGE-06?MCK?
1 18600 [5.4] 9000 [2.6]
34800 [10.2] 14.5 12
725 [342] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
RGGE-07?MCK?
1 18700 [5.5] 8900 [2.6]
34800 [10.2] 14.5 12
750 [354] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
RGJF-06?MCK?
1 18600 [5.4] 9000 [2.6]
34800 [10.2] 14.5 12
725 [342] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
RGJF-07?MCK?
1 18700 [5.5] 8900 [2.6]
34800 [10.2] 14.5 12
750 [354] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
RGLE-07?AMK?
1 18900 [5.5] 8900 [2.6]
34800 [10.2] 15 12.5
750 [354] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
RGPE-05?BMK?
1 18700 [5.5] 8900 [2.6]
34400 [10.1] 14.5 12
750 [354] 0
2 23300 [6.8] 11100 [3.3] 975 [460] 77
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
16AJL Series
7
Outdoor
Unit
16AJL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
36
RCFL-H*3617
RGPE-07?AMK?
1 18600 [5.4] 9000 [2.6]
34400 [10.1] 15 12.5
725 [342] 0
2 23400 [6.9] 11000 [3.2] 1000 [472] 77
RGRM-04?MAE?
1 18700 [5.5] 8900 [2.6]
34600 [10.1] 14.5 12
750 [354] 0
2 23800 [7.0] 10800 [3.2] 1025 [484] 77
RGRM-06?MAE?
1 19200 [5.6] 8800 [2.6]
34400 [10.1] 14.5 12
775 [366] 0
2 23400 [6.9] 11000 [3.2] 1000 [472] 77
RGRM-07?MAE?
1 19000 [5.6] 8800 [2.6]
34400 [10.1] 14 11.5
800 [378] 0
2 23600 [6.9] 10800 [3.2] 1025 [484] 77
RGTM-06?MAE?
1 19900 [5.8] 8500 [2.5]
34600 [10.1] 14.5 12
900 [425] 0
2 23800 [7.0] 10800 [3.2] 1025 [484] 77
ROCA-070E03
1 19200 [5.6] 8800 [2.6]
34600 [10.1] 15 12.5
800 [378] 0
2 23600 [6.9] 11000 [3.2] 1000 [472] 77
ROCA-070E04
1 19200 [5.6] 8800 [2.6]
34600 [10.1] 15 12.5
800 [378] 0
2 23600 [6.9] 11000 [3.2] 1000 [472] 77
ROLA-070E03
1 18600 [5.4] 9000 [2.6]
34400 [10.1] 14.5 12
725 [342] 0
2 23300 [6.8] 11100 [3.3] 975 [460] 77
ROLA-070E04
1 18600 [5.4] 9000 [2.6]
34400 [10.1] 14.5 12
725 [342] 0
2 23300 [6.8] 11100 [3.3] 975 [460] 77
RCFL-H*3617+RXMD-C04 Coil Only
1 18600 [5.4] 8800 [2.6]
34400 [10.1] 13.5 11
800 [378] 0
2 23600 [6.9] 10800 [3.2] 1050 [495] 77
RCFL-H*3621
RGFE-06?MCK?
1 18600 [5.4] 9000 [2.6]
34400 [10.1] 14.5 12
725 [342] 0
2 23400 [6.9] 11000 [3.2] 1000 [472] 77
RGFE-07?MCK?
1 18600 [5.4] 9000 [2.6]
34600 [10.1] 14.5 12
725 [342] 0
2 23800 [7.0] 10800 [3.2] 1025 [484] 77
RGFE-09?ZCM?
1 19800 [5.8] 8600 [2.5]
35400 [10.4] 14.5 12
875 [413] 0
2 25200 [7.4] 10200 [3.0] 1200 [566] 77
RGFG-06?MCK?
1 18600 [5.4] 9000 [2.6]
34400 [10.1] 14.5 12
725 [342] 0
2 23400 [6.9] 11000 [3.2] 1000 [472] 77
RGFG-07?MCK?
1 19200 [5.6] 8800 [2.6]
34400 [10.1] 14.5 12
800 [378] 0
2 23400 [6.9] 11000 [3.2] 1000 [472] 77
RGFG-09?ZCM?
1 19800 [5.8] 8600 [2.5]
35400 [10.4] 14.5 12
875 [413] 0
2 25200 [7.4] 10200 [3.0] 1200 [566] 77
RGFG-10?ZCM?
1 19900 [5.8] 8500 [2.5]
35400 [10.4] 14.5 12
900 [425] 0
2 25200 [7.4] 10200 [3.0] 1200 [566] 77
RGGE-06?MCK?
1 18600 [5.4] 9000 [2.6]
34800 [10.2] 14.5 12
725 [342] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
RGGE-07?MCK?
1 18700 [5.5] 8900 [2.6]
34800 [10.2] 14.5 12
750 [354] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
RGGE-10?ZCM?
1 19800 [5.8] 8600 [2.5]
35400 [10.4] 14.5 12
875 [413] 0
2 25200 [7.4] 10200 [3.0] 1200 [566] 77
RGJF-06?MCK?
1 18600 [5.4] 9000 [2.6]
34800 [10.2] 14.5 12
725 [342] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
RGJF-07?MCK?
1 18700 [5.5] 8900 [2.6]
34800 [10.2] 14.5 12
750 [354] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
16AJL Series
8
Outdoor
Unit
16AJL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
36
RCFL-H*3621
RGJF-10?ZCM?
1 19800 [5.8] 8600 [2.5]
35400 [10.4] 14.5 12
875 [413] 0
2 25200 [7.4] 10200 [3.0] 1200 [566] 77
RGLE-07?AMK?
1 18900 [5.5] 8900 [2.6]
34800 [10.2] 15 12
750 [354] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
RGLE-07?BRQ?
1 19200 [5.6] 8800 [2.6]
35000 [10.3] 15 12
775 [366] 0
2 24200 [7.1] 10800 [3.2] 1025 [484] 77
RGLE-10?BRM?
1 19800 [5.8] 8600 [2.5]
35600 [10.4] 15 12
875 [413] 0
2 25400 [7.4] 10200 [3.0] 1200 [566] 77
RGPE-05?BMK?
1 18700 [5.5] 8900 [2.6]
34400 [10.1] 14.5 12
750 [354] 0
2 23300 [6.8] 11100 [3.3] 975 [460] 77
RGPE-07?AMK?
1 18600 [5.4] 9000 [2.6]
34600 [10.1] 15 12
725 [342] 0
2 23600 [6.9] 11000 [3.2] 1000 [472] 77
RGPE-07?BRQ?
1 18600 [5.4] 9000 [2.6]
35000 [10.3] 15 12
725 [342] 0
2 24200 [7.1] 10800 [3.2] 1025 [484] 77
RGRM-04?MAE?
1 18700 [5.5] 8900 [2.6]
34600 [10.1] 14.5 12
750 [354] 0
2 23800 [7.0] 10800 [3.2] 1025 [484] 77
RGRM-06?MAE?
1 19200 [5.6] 8800 [2.6]
34400 [10.1] 14.5 12
775 [366] 0
2 23400 [6.9] 11000 [3.2] 1000 [472] 77
RGRM-07?MAE?
1 19000 [5.6] 8800 [2.6]
34400 [10.1] 14 11.5
800 [378] 0
2 23600 [6.9] 10800 [3.2] 1025 [484] 77
RGRM-07?YBG?
1 18400 [5.4] 9000 [2.6]
34000 [10.0] 14.5 12
700 [330] 0
2 22900 [6.7] 11100 [3.3] 975 [460] 77
RGRM-10?ZAJ?
1 19800 [5.8] 8600 [2.5]
35000 [10.3] 14.5 12
875 [413] 0
2 24600 [7.2] 10400 [3.0] 1150 [543] 77
RGTM-06?MAE?
1 19900 [5.8] 8500 [2.5]
34600 [10.1] 14.5 12
900 [425] 0
2 23800 [7.0] 10800 [3.2] 1025 [484] 77
RGTM-07?RBG?
1 19200 [5.6] 8800 [2.6]
34800 [10.2] 15 12.5
800 [378] 0
2 24000 [7.0] 10800 [3.2] 1050 [495] 77
ROCA-070E03
1 19200 [5.6] 8800 [2.6]
34600 [10.1] 15 12.5
800 [378] 0
2 23600 [6.9] 11000 [3.2] 1000 [472] 77
ROCA-070E04
1 19200 [5.6] 8800 [2.6]
34600 [10.1] 15 12.5
800 [378] 0
2 23600 [6.9] 11000 [3.2] 1000 [472] 77
ROLA-070E03
1 20100 [5.9] 8500 [2.5]
35400 [10.4] 15 12.5
900 [425] 0
2 25100 [7.4] 10300 [3.0] 1175 [554] 77
ROLA-070E04
1 20100 [5.9] 8500 [2.5]
35400 [10.4] 15 12.5
900 [425] 0
2 25100 [7.4] 10300 [3.0] 1175 [554] 77
ROLA-115E05
1 20100 [5.9] 8500 [2.5]
35600 [10.4] 15 12.5
900 [425] 0
2 25400 [7.4] 10200 [3.0] 1200 [566] 77
RCFL-H*3621+RXMD-C04 Coil Only
1 18600 [5.4] 8800 [2.6]
34400 [10.1] 13.5 11.5
800 [378] 0
2 23600 [6.9] 10800 [3.2] 1050 [495] 77
RCFL-H*3821
RGFE-06?MCK?
1 18700 [5.5] 9300 [2.7]
34800 [10.2] 15 12
725 [342] 0
2 23700 [6.9] 11100 [3.3] 1000 [472] 77
RGFE-07?MCK?
1 18700 [5.5] 9300 [2.7]
35000 [10.3] 15.5 12.5
725 [342] 0
2 24100 [7.1] 10900 [3.2] 1025 [484] 77
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures.