18Stk Blower Assembly (Includes items 22-25, 27)AS-67876-44AS-67876-45AS-67876-46AS-67876-47
19Transformer w/FuseSee Electrical Group
20Mounting Plate- ControlAE-67877-01AE-67877-01AE-67877-01AE-67877-01
21IntegratedFurnace Control Board (IFC)See Gas Controls
22Thermistor - Return Air SensorN/AN/AN/AN/A
23HousingAS-61674-02AS-61674-02AS-61674-02AS-61674-02
24Stk Blower Motor - ECM51-24374-2651-24374-2751-24374-2851-24376-23
Motor Mount Kit (Grommets, Screws, Nuts, BellyBand, Brackets)70-24104-8270-24104-8270-24104-8270-24104-82
ECM Motor Mount (Belly Band)70-24104-0270-24104-0270-24104-0270-24104-02
25Motor MountBracket (4)AE-61956-01AE-61956-01AE-61956-01AE-61956-01
26Choke- Power FactorSee Electrical Group
27Stk Blower Wheel70-24254-0270-24254-0270-24254-0270-103207-01
18 Stk,6 Blower Assembly (Includes items 22-25, 27)- See Note 6
19Transformer w/FuseSee Electrical Group
20Mounting Plate- ControlAE-67877-01AE-67877-01
21IntegratedFurnace Control Board (IFC)See Gas Controls
22Thermistor - Return Air SensorN/AN/A
23HousingAS-61674-08AS-61674-08
24 Stk,6 Blower Motor- ECM (See Note 6)
24 Stk,6 Blower Motor- ECM (See Note 6)
Motor Mount Kit (Grommets, Screws, Nuts, BellyBand, Brackets)70-24104-8270-24104-82
ECM Motor Mount (Belly Band)70-24104-0270-24104-02
25Motor MountBracket (4)AE-61956-01AE-61956-01
26Choke- Power FactorSee Electrical Group
27 Stk,6 BlowerWheel (See Note 6)
27 Stk,6 BlowerWheel (See Note 6)
No. Notes
18Stk Blower Assembly (Includes items 22-25, 27)AS-67876-50
19Transformer w/FuseSee Electrical Group
20Mounting Plate- ControlAE-67877-01
21IntegratedFurnace Control Board (IFC)See Gas Controls
22Thermistor - Return Air SensorN/A
23HousingAS-61674-03
24Stk Blower Motor - ECM51-24376-26
Motor Mount Kit (Grommets, Screws, Nuts, BellyBand, Brackets)70-24104-82
ECM Motor Mount (Belly Band)70-24104-02
25Motor MountBracket (4)AE-61956-01
26Choke- Power FactorSee Electrical Group
27Stk Blower Wheel70-23111-20
MODEL
HEATING CAPACITY
BLOWER DESIGNATION
VARIATION
AIRFLOW
HEAT EXCHANGER, BURNER / MANIFOLD
MODEL
GAS CODE
GAS CONTROLS
UGRM
04
M
A
E
AE-67863-01
(2)
UGRM
10
Z
A
J
AE-61913-02
(2)
AE-67863-01
(6)
UGRM
HJ
UGRM
06
M
A
E
AE-67863-01
(3)
UGRM
12
R
A
J
AE-61913-02
(2)
AE-67863-01
(7)
UGRM
HK
UGRM
07
M
A
E
AE-61913-02
(2)
AE-67863-01
(4)
UGRM
07
Y
B
G
AE-61913-02
(2)
AE-67863-01
(4)
UGRM
09
Z
A
J
AE-61913-02
(2)
AE-67863-01
(5)
Page 9 of 14
20-November-2015
92-42801-UGRM
CAUTION: Selection ofthe correct Natural Gas Orifice requires the following information for thespecific installation:
1) Altitude in of the installation (ft.).
2) Average energy content of the Natural Gasfuel from the local supplier (BTU/cu. ft.).
For detailed information and instructions for Orifice selection, see the Gas Furnace LPConversion Kit Index 92-21519-59 and thelatest edition of the
National Fuel Gas Code Handbook, or the National Standard of Canada, Natural Gas andPropane Installation Code, CAN B149.1.
CAUTION:This information is provided for replacement purposes only. Conversion for operation at High Altitude must be doneusing the kit specified
on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is based on 15,000 BTU/HR per burner.
NOTE: Factory installed orifices are calculated andsized based on a Natural Gas heating value of 1075 BTU/cu. ft.and an elevation of 0 - 2000ft.
Elevation (ft.)
CAUTION: Selection ofthe correct LP Orifice requires the altitude of the specific installation (ft.).
For detailed information and instructions for Orifice selection, see the Gas Furnace LPConversion Kit Index 92-21519-59 and thelatest edition of the
National Fuel Gas Code Handbook (NFG), or the National Standard of Canada, Natural Gasand Propane Installation Code, CAN B149.1.
CAUTION:This information is provided for replacement purposes only. Conversion to LP or for operation at High Altitude shouldbe done using the
kit(s) specified on the product specification sheet for theunit.
NOTE:This Orifice sizing chart is based on 15,000 BTU/HR per burner. Also, the chart is developed usingthe specified pressure setting of 10 in. water column
instead of the 11.0 inwater column used by the NFG and CANB149.1.
NOTE: Orifices supplied inthe LP Conversion Kit are calculated andsized based on an altitude of 0 - 2000ft.
Elevation (ft.)Orifice
0 to 2000 ft.62-22175-91
2001 to 300062-22175-91
3001 to 400062-22175-90
4001 to 500062-22175-58
5001 to 600062-22175-59
6001 to 700062-22175-60
7001 to 800062-22175-62
8001 to 900062-22175-63
9001 to 100062-22175-64
90% GAS FURNACE - ORIFICE SELECTION CHART - NATURAL GAS
90% GAS FURNACE - ORIFICE SELECTION CHART - LP
Page 10 of 14
20-November-2015
92-42801-UGRM
Exploded View
Page 11 of 14
20-November-2015
92-42801-UGRM
Blower Assembly
Page 12 of 14
20-November-2015
92-42801-UGRM
Burner Assembly
Page 13 of 14
20-November-2015
92-42801-UGRM
NOTES
Stk It is recommended that stock be maintained for this part.
N/A Not Applicable
1 Order the specified LP ConversionKit.
2 Order GasValve for Natural Gas along with LP Conversion Kit
3 The Induced Draft Blower utilized before F3010, used a remotely mounted Capacitor. Blowers after this date
include a Capacitor with the Induced Draft Blower.
4 For UGRM-07EYBGS units manufactured before date code F3211, the replacement Outlet Air Pipe and
Connector/Transition Assembly may be different from that originally supplied with the unit. For models
manufactured before date code F3211, when replacing either of these components, both must be changed to the
parts shown.
5 Jacket is not available for replacement.
6 On or after Date Code 1112, A 11 X 10 inch blower assembly replaced the original 12 X 11 inch blower assembly.
This change provides equal blower performance and reduces overall motor noise. Note: This change is not
backward compatible, as motor programming was changed to provide the same CFM performance as the original
12 x 11 assembly.
7 Replacement of Power Factor Choke is optional on units with 1/2 hp, X-13 and ECM, motors produced before
F1712. After approximate date code F1712, production units will be supplied with a JumperWire Assembly
(45-104318-01) in lieu of a Power Factor Choke. This Jumper Wire Assembly can be retrofitted to units built before
Date Code F1712.