F = Fort Smith, AR(3)BLOWER(8)WEEK(4)HEATING ELEMENT(9)YEAR (5)SPECIAL AREA REQUIREMENT(10)PRODUCTION NUMBER
F08139999
(1)(2)(3)(4)
(1)PLANT CODE(2)WEEK (DATE CODE)(3)YEAR (4)PRODUCTION NUMBERNote: For Gas Code, see Control System Gas Code on Rating Plate
SERIAL NUMBER EXPLANATION (Units Produced before Nov. 2013)
SERIAL NUMBER EXPLANATION (Units Produced after Nov. 2013)
MODEL NUMBER EXPLANATION
Page 3 of 13
10-January-2017
92-42801-UGPN
MODEL
No. Notes
1Plug Button - 1-3/16 in. opening (2)45-22980-0145-22980-0145-22980-0145-22980-01
2Burner Compartment Door (Neutra Green)AS-101213-01AS-101214-01AS-101214-01AS-101214-01
2Burner Compartment Door (Granite/Steel Gray)AS-101213-10AS-101214-10AS-101214-10AS-101214-10
3Blower/Filter Door (Neutra Green)AS-67893-01AS-67894-01AS-67894-01AS-67894-01
3Blower/Filter Door (Granite/Steel Gray)AS-67893-13AS-67894-13AS-67894-13AS-67894-13
4Door Switch (Push Button)See Electrical Group
5Junction BoxAE-61475-02AE-61475-02AE-61475-02AE-61475-02
6Junction Box CoverAE-61476-02AE-61476-02AE-61476-02AE-61476-02
7Filter - Plastic54-24094-0154-24094-0154-24094-0154-24094-01
Filter Retainer Rod45-24095-0145-24095-0145-24095-0145-24095-01
Filter Rod Support AngleAE-60520-01AE-60520-01AE-60520-01AE-60520-01
Filter Support AngleAE-61883-01AE-61883-01AE-61883-01AE-61883-01
8Filter Retainer BracketAE-61880-01AE-61880-01AE-61880-01AE-61880-01
9Blower AssemblySee Blower Group
103Jacket (See Note 3)N/AN/AN/AN/A
11Baffle - Side (2)AE-61606-01AE-61606-01AE-61606-01AE-100548-01
12Heat Exchanger Brackets (2)See Heat Exchanger Group
13Baffle - RearAE-61666-01AE-61607-01AE-61607-01AE-61607-01
14Heat Exchanger AssemblySee Heat Exchanger Group
15Limit - Main Limit (Heat Exchanger Panel)See Electrical Group
16Top PlateAE-101095-01AE-101095-02AE-101095-02AE-101095-02
17Intake Air DeflectorAE-101077-02AE-101077-01AE-101077-01AE-101077-01
181Pressure SwitchSee Electrical Group
19Induced Draft Blower w/GasketSee Electrical Group
25Limit - Heat Assisted (Blower Housing)See Electrical Group
26Mounting Control PlateSee Blower Group
27Integrated Furnace Control Board (IFC)See Gas Controls
28TransformerSee Electrical Group
29Gas ValveSee Gas Controls
37Limit - Manual Reset (Burner Compartment)See Electrical Group
39IgnitorSee Gas Controls
191Induced Draft Blower w/GasketSee Electrical Group
25Limit - Heat Assisted (Blower Housing)See Electrical Group
26Mounting Control PlateSee Blower Group
27Integrated Furnace Control Board (IFC)See Gas Controls
28TransformerSee Electrical Group
29Gas ValveSee Gas Controls
37Limit - Manual Reset (Burner Compartment)See Electrical Group
39IgnitorSee Gas Controls
38Bracket - Direct SparkAE-61885-02AE-61885-02AE-61885-02AE-61885-02AE-61885-02
39Stk Ignitor - Direct Spark62-24164-0162-24164-0162-24164-0162-24164-0162-24164-01
LP Conversion Kit:Stk U.S.ModelsFP-15FP-15FP-15FP-15FP-15
Stk Canadian ModelsFP-15FP-04FP-04FP-15FP-15
No.Notes
27Stk Integrated Furnace Control Board (IFC)62-24140-04
29Stk Gas Valve - Natural Gas60-105055-01
29Stk,2 Gas Valve- LPSee Note 2
33Stk Flame Sensor62-23543-01
38Bracket - Direct SparkAE-61885-02
39Stk Ignitor - Direct Spark62-24164-01
LP Conversion Kit:Stk U.S.ModelsFP-15
MODEL
GAS CODE
(TYPE)
MODEL
GAS CODE
(TYPE)
UGPN
FD
(DSI)
GAS CONTROLS
GAS CONTROLS
UGPN
FS
(DSI)
UGPN
FT
(DSI)
UGPN
FU
(DSI)
UGPN
JY
(DSI)
UGPN
FV
(DSI)
Page 8 of 13
10-January-2017
92-42801-UGPN
CAUTION: Selection of the correct Natural Gas Orifice requires the following information for the specific installation:
1) Altitude in of the installation (ft.).
2) Average energy content of the Natural Gas fuel from the local supplier (BTU/cu. ft.).
For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-59 and the latest edition of the
National Fuel Gas Code Handbook, or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1.
CAUTION:This information is provided for replacement purposes only. Conversion for operation at High Altitude must be done using the kit specified
on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is based on 25,000 BTU/HR per burner.
NOTE: Factory installed orifices are calculated and sized based on a Natural Gas heating value of 1075 BTU/cu. ft. and an elevation of 0 - 3000 ft.
Elevation (ft.)
CAUTION: Selection of the correct LP Orifice requires the altitude of the specific installation (ft.).
For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-59 and the latest edition of the
National Fuel Gas Code Handbook (NFG), or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1.
CAUTION:This information is provided for replacement purposes only. Conversion to LP or for operation at High Altitude should be done using the
kit(s) specified on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is based on 25,000 BTU/HR per burner. Also, the chart is developed using the specified pressure setting of 10 in. water column
instead of the 11.0 in water column used by the NFG and CANB149.1.
NOTE: Orifices supplied in the LP Conversion Kit are calculated and sized based on an altitude of 0 - 4000 ft.