UGPH
Parts List
25-January-2017
This parts list is current as of the above revision date.
See http://www.rheempartslists.net/92-42801-UGPH.pdf for the current revision.
80% Gas Furnaces
Table of Contents
Model Explanation.... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . ... Page 3
Parts Numbers
Panels - Miscellaneous 04-07.... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... .. Page 4
Panels - Miscellaneous 10-15.... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... .. Page 5
Electrical Group . ..... ..... ..... ..... ..... .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... ..... ..... ... Page 6
Blower Group... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... ..... ..... .... Page 7
Heat Exchanger-Burner Group.... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... . Page 8
Gas Controls ... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... .... Page 9
Orifice Selection Chart.... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... ..... ... Page 10
Drawings/Photographs
Exploded View .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... Page 11
Blower Assembly ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... ..... ..... .. Page 12
Burner Assembly ... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... .... Page13
NOX Insert Assembly after F0299. ..... ..... ..... ..... .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... Page 14
Notes ... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... .. Page 15
Page 2 of 15
25-January-2017
92-42801-UGPH
MODEL NUMBER EXPLANATION
U G P H - 0 7 E A U E R
(1) (2) (3) (4) (5) (6) (7) (8) (9)
(1) TRADEBRAND IDENTIFICATION (6) VARIATIONS
A = Standard Cabinet
(2) MODEL B = Wide Cabinet
G= Gas Furnace
(7) BLOWER DESIGNATION
(3) TYPE U = 11 x 6
P = Upflow/Horizontal M = 11 x 7
R = 11 x 10
(4) DESIGN SERIES / VARIATION
(8) AIRFLOW
(5) HEATING INPUT DESIGNATION E = 1100-1300 CFM
04 = 45,000 BTU/HR G = 1500-1700 CFM
05 = 50,000 BTU/HR J = 1900-2100 CFM
06 = 65,000 BTU/HR K = 600-2000 CFM
07 = 75,000 BTU/HR M = 1200-2000 CFM
10 = 100,000 BTU/HR N = 800-2000 CFM
12 = 125,000 BTU/HR S = 500-1300 CFM
15 = 150,000 BTU/HR
(9) FUEL DESIGNATION
E = Electric R = Natural Gas
N = NOX
SERIAL NUMBER EXPLANATION
D C 5 D 3 0 7 F 2 2 9 4 9 9 9 9
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
(1) GAS CODE (6) MOTOR HORSEPOWER
(2) LIMIT CONTROL (7) PLANT
F = Fort Smith, AR
(3) BLOWER
(8) WEEK
(4) HEATING ELEMENT
(9) YEAR
(5) SPECIAL AREA REQUIREMENT
(10) PRODUCTION NUMBER
Page 3 of 15
25-January-2017
92-42801-UGPH
MODEL
No. Notes
1 Jacket AS-61690-01 AS-61690-01 AS-61690-02 AS-61690-03 AS-61690-02 AS-61690-03 AS-61690-04
2 Top Plate AE-61657-01 AE-61657-01 AE-61657-02 AE-61657-02 AE-61657-02 AE-61657-02 AE-61657-03
3 Blower/Filter Door AS-67893-01 AS-67893-01 AS-67894-01 AS-67894-01 AS-67894-01 AS-67894-01 AS-67895-01
4 Burner Door AE-61675-01 AE-61675-01 AE-61676-01 AE-61676-01 AE-61676-01 AE-61676-01 AE-61677-01
Plug Button - 1-3/16 in. opening (2) 45-22980-01 45-22980-01 45-22980-01 45-22980-01 45-22980-01 45-22980-01 45-22980-01
5 Mounting Control Plate AE-67877-01 AE-67877-01 AE-67877-01 AE-67877-01 AE-67877-01 AE-67877-01 AE-67877-01
Control Box 68-22857-01 68-22857-01 68-22857-01 68-22857-01 68-22857-01 68-22857-01 68-22857-01
Control Box Cover AE-61699-02 AE-61699-02 AE-61699-02 AE-61699-02 AE-61699-02 AE-61699-02 AE-61699-02
Junction Box AE-61475-02 AE-61475-02 AE-61475-02 AE-61475-02 AE-61475-02 AE-61475-02 AE-61475-02
Junction Box Cover AE-61476-02 AE-61476-02 AE-61476-02 AE-61476-02 AE-61476-02 AE-61476-02 AE-61476-02
10 Pressure Switch See Electrical Group
11 Door Switch - Push Button See Electrical Group
12 Limit - Main Limit (Heat Exchanger Panel) See Electrical Group
13
Limit - Heat Assisted (Blower Housing) See Electrical Group
14 Bracket - Limit (Manual Reset) (3) AE-61600-02 AE-61600-02 AE-61600-02 AE-61600-02 AE-61600-02 AE-61600-02 AE-61600-02
15 Transformer See Electrical Group
Power Factor Choke N/A N/A 46-24256-02 N/A N/A N/A 46-24256-02
16 Induced Draft Blowerw/Gasket See Electrical Group
17 Blower Assembly See Blower Group
23 Heat Exchanger Assembly See Heat Exchanger Group
Heat Exchanger Bracket See Heat Exchanger Group
Filter Support Angle AE-61883-01 AE-61883-01 AE-61883-01 AE-61883-01 AE-61883-01 AE-61883-01 AE-61883-01
Silicone Rubber Tubing 79-21491-03 79-21491-03 79-21491-03 79-21491-03 79-21491-03 79-21491-03 79-21491-03
Filter Rod Support Angle AE-60520-01 AE-60520-01 AE-60520-01 AE-60520-01 AE-60520-01 AE-60520-01 AE-60520-01
Filter Support Angle AE-61883-01 AE-61883-01 AE-61883-01 AE-61883-01 AE-61883-01 AE-61883-01 AE-61883-01
Filter Retainer Rod 45-24095-01 45-24095-01 45-24095-01 45-24095-01 45-24095-01 45-24095-01 45-24095-01
24 Filter - Permanent Plastic 54-24094-01 54-24094-01 54-24094-01 54-24094-01 54-24094-01 54-24094-01 54-24094-02
25 Gas Valve See Gas Controls
26 Integrated Furnace Control Board (IFC) See Gas Controls
27 Ignitor See Gas Controls
HEATING CAPACITY
VARIATION
BLOWER DESIGNATION
AIRFLOW
Limit - Manual Reset (Burner
Compartment)
UGPH
04
A
U
S
PANELS, SHEET METAL, MISCELLANEOUS
UGPH
05
A
U
E
UGPH
05
B
M
K
See Electrical Group
UGPH
06
A
U
E
UGPH
07
A
M
G
UGPH
07
A
U
E
UGPH
07
B
R
K
Page 4 of 15
25-January-2017
92-42801-UGPH
MODEL
No. Notes
1 Jacket AS-61690-22 AS-61690-24 AS-61690-04 AS-61690-25 AS-61690-05 AS-61690-25
2 Top Plate AE-61657-02 AE-61657-03 AE-61657-03 AE-61657-04 AE-61657-04 AE-61657-04
3 Blower/Filter Door AS-67894-01 AS-67895-01 AS-67895-01 AS-67896-01 AS-67896-01 AS-67896-01
4 Burner Door AE-61676-01 AE-61677-01 AE-61677-01 AE-61678-01 AE-61678-01 AE-61678-01
Plug Button - 1-3/16 in. opening (2) 45-22980-01 45-22980-01 45-22980-01 45-22980-01 45-22980-01 45-22980-01
5 Mounting Control Plate AE-67877-01 AE-67877-01 AE-67877-01 AE-67877-01 AE-67877-01 AE-67877-01
Control Box 68-22857-01 68-22857-01 68-22857-01 68-22857-01 68-22857-01 68-22857-01
Control Box Cover AE-61699-02 AE-61699-02 AE-61699-02 AE-61699-02 AE-61699-02 AE-61699-02
Junction Box AE-61475-02 AE-61475-02 AE-61475-02 AE-61475-02 AE-61475-02 AE-61475-02
Junction Box Cover AE-61476-02 AE-61476-02 AE-61476-02 AE-61476-02 AE-61476-02 AE-61476-02
10 Pressure Switch See Electrical Group
11 Door Switch - Push Button See Electrical Group
12 Limit - Main Limit (Heat Exchanger Panel) See Electrical Group
13 Limit - Manual Reset (Burner Compartment) See Electrical Group
Limit - Heat Assisted (Blower Housing) See Electrical Group
14 Bracket - Limit (Manual Reset) (3) AE-61600-02 AE-61600-02 AE-61600-02 AE-61600-02 AE-61600-02 AE-61600-02
15 Transformer See Electrical Group
Power Factor Choke N/A N/A 46-24256-02 N/A 46-24256-02 N/A
16 Induced Draft Blowerw/Gasket See Electrical Group
17 Blower Assembly See Blower Group
23 Heat Exchanger Assembly See Heat Exchanger Group
Heat Exchanger Bracket See Heat Exchanger Group
Filter Support Angle AE-61883-01 AE-61883-01 AE-61883-01 AE-61883-01 AE-61883-01 AE-61883-01
Silicone Rubber Tubing 79-21491-03 79-21491-03 79-21491-03 79-21491-03 79-21491-03 79-21491-03
Filter Rod Support Angle AE-60520-01 AE-60520-01 AE-60520-01 AE-60520-01 AE-60520-01 AE-60520-01
Filter Support Angle AE-61883-01 AE-61883-01 AE-61883-01 AE-61883-01 AE-61883-01 AE-61883-01
Filter Retainer Rod 45-24095-01 45-24095-01 45-24095-01 45-24095-01 45-24095-01 45-24095-01
24 Filter - Permanent Plastic 54-24094-01 54-24094-02 54-24094-02 54-24094-03 54-24094-03 54-24094-03
25 Gas Valve See Gas Controls
26 Integrated Furnace Control Board (IFC) See Gas Controls
27 Ignitor See Gas Controls
HEATING CAPACITY
VARIATION
BLOWER DESIGNATION
AIRFLOW
PANELS, SHEET METAL, MISCELLANEOUS
UGPH
10
A
M
E
UGPH
10
B
R
J
UGPH
10
B
R
M
UGPH
12
A
R
J
UGPH
12
A
R
M
UGPH
15
A
R
J
Page 5 of 15
25-January-2017
92-42801-UGPH
MODEL
No. Notes
10 Stk Pressure Switch - Before F3702 42-24335-03 42-24335-03 42-23648-03 42-24335-03 42-24335-03 42-24335-03 42-23648-03
10 Stk Pressure Switch - On or After F3702 42-24335-03 42-23648-02 42-23648-03 42-24335-03 42-23648-02 42-23648-02 42-23648-03
11 Door Switch - Push Button 42-22692-01 42-22692-01 42-22692-04 42-22692-01 42-22692-01 42-22692-01 42-22692-04
12 Stk Limit - Main Limit (Heat Exchanger Panel) 47-25349-01 47-25349-03 47-25349-01 47-25349-02 47-25349-01 47-25349-02 47-25349-04
13 Stk
Stk Limit- Heat Assisted (Blower Housing) 47-22860-01 47-22860-01 47-22860-01 47-22860-01 47-22860-01 47-22860-01 47-22860-01
15 Stk Transformer - On or After F1399 46-24124-03 46-24124-03 46-24124-03 46-24124-03 46-24124-03 46-24124-03 46-24124-03
15 Stk Transformer w/Fuse - Before F1399 46-24124-05 46-24124-05 46-24124-05 46-24124-05 46-24124-05 46-24124-05 46-24124-05
Transformer Fuse (Small - 9/16 in.) 46-22863-82 46-22863-82 46-22863-82 46-22863-82 46-22863-82 46-22863-82 46-22863-82
Transformer Fuse (Large - 1-9/16 in.) 46-22863-84 46-22863-84 46-22863-84 46-22863-84 46-22863-84 46-22863-84 46-22863-84
16 Stk Induced Draft Blower w/Gasket - Before F2002 70-24071-04 70-24157-03 70-24157-03 70-24071-05 70-24157-03 70-24157-03 70-24157-03
16 Stk
26 Integrated Furnace Control Board (IFC) See Gas Controls
Wiring Harness - 9 pin from board to 9 pin AS-61997-04 AS-61997-04 AS-61997-04 AS-61997-04 AS-61997-04 AS-61997-04 AS-61997-04
Wiring Harness - 9 pin to 9 terminals AS-61998-01 AS-61998-01 AS-61998-01 AS-61998-01 AS-61998-01 AS-61998-01 AS-61998-01
Wiring Harness - 2 pin from board to 4 pin 45-24371-09 45-24371-09 45-24371-09 45-24371-09 45-24371-09 45-24371-09 45-24371-09
Wiring Harness - 4 pin to 2 terminals 45-24371-14 45-24371-14 45-24371-14 45-24371-14 45-24371-14 45-24371-14 45-24371-14
Wiring Harness - 4 pin to 2 pin and 2 terminals 45-24371-10 45-24371-10 45-24371-10 45-24371-10 45-24371-10 45-24371-10 45-24371-10
Wiring Harness - 6 pin from board to 4 pin 45-24371-05 45-24371-05 45-24371-05 45-24371-05 45-24371-05 45-24371-05 45-24371-05
No. Notes
10 Stk Pressure Switch - Before F3702 42-24335-03 42-24335-03 42-23648-03 42-24335-02 42-23648-02 42-24335-02
10 Stk Pressure Switch - On or After F3702 42-23648-02 42-23648-02 42-23648-03 42-24335-02 42-23648-02 42-24335-02
11 Door Switch - Push Button 42-22692-01 42-22692-01 42-22692-04 42-22692-01 42-22692-04 42-22692-01
12 Stk Limit - Main Limit (Heat Exchanger Panel) 47-25349-02 47-25349-01 47-25349-01 47-25349-03 47-25349-03 47-25349-03
13 Stk
Stk Limit- Heat Assisted (Blower Housing) 47-22860-03 47-22860-01 47-22860-01 47-22860-03 47-22860-03 47-22860-04
15 Stk Transformer - On or After F1399 46-24124-03 46-24124-03 46-24124-03 46-24124-03 46-24124-03 46-24124-03
15 Stk Transformer w/Fuse - Before F1399 46-24124-05 46-24124-05 46-24124-05 46-24124-05 46-24124-05 46-24124-05
Transformer Fuse (Small - 9/16 in.) 46-22863-82 46-22863-82 46-22863-82 46-22863-82 46-22863-82 46-22863-82
Transformer Fuse (Large - 1-9/16 in.) 46-22863-84 46-22863-84 46-22863-84 46-22863-84 46-22863-84 46-22863-84
16 Stk Induced Draft Blower w/Gasket - Before F2002 70-24157-03 70-24157-03 70-24157-03 70-24157-03 70-24157-03 70-24157-03
16 Stk
26 Integrated Furnace Control Board (IFC) See Gas Controls
Wiring Harness - 9 pin from board to 9 pin AS-61997-04 AS-61997-04 AS-61997-04 AS-61997-04 AS-61997-04 AS-61997-04
Wiring Harness - 9 pin to 9 terminals AS-61998-01 AS-61998-01 AS-61998-01 AS-61998-01 AS-61998-01 AS-61998-01
Wiring Harness - 2 pin from board to 4 pin 45-24371-09 45-24371-09 45-24371-09 45-24371-09 45-24371-09 45-24371-09
Wiring Harness - 4 pin to 2 terminals 45-24371-14 45-24371-14 45-24371-14 45-24371-14 45-24371-14 45-24371-14
Wiring Harness - 4 pin to 2 pin and 2 terminals 45-24371-10 45-24371-10 45-24371-10 45-24371-10 45-24371-10 45-24371-10
Wiring Harness - 6 pin from board to 4 pin 45-24371-05 45-24371-05 45-24371-05 45-24371-05 45-24371-05 45-24371-05
HEATING CAPACITY
VARIATION
BLOWER DESIGNATION
AIRFLOW
Limit - Manual Reset (Burner Compartment)
(3)
Induced Draft Blowerw/Gasket - On or After
F2002
MODEL
HEATING CAPACITY
VARIATION
BLOWER DESIGNATION
AIRFLOW
Limit - Manual Reset (Burner Compartment)
(3)
Induced Draft Blowerw/Gasket - On or After
F2002
UGPH
04
A
U
S
47-22861-01 47-22861-01 47-22861-01 47-22861-01 47-22861-01 47-22861-01 47-22861-01
70-24071-04 70-24175-01 70-24157-03 70-24071-05 70-24175-01 70-24175-01 70-24157-03
UGPH
10
A
M
E
47-22861-01 47-22861-01 47-22861-01 47-22861-01 47-22861-01 47-22861-01
70-24175-01 70-24175-01 70-24157-03 70-24175-01 70-24157-03 70-24175-01
UGPH
05
A
U
E
ELECTRICAL GROUP
UGPH
10
B
R
J
ELECTRICAL GROUP
UGPH
05
B
M
K
UGPH
10
B
R
M
UGPH
06
A
U
E
UGPH
12
A
R
J
UGPH
07
A
M
G
UGPH
12
A
R
M
UGPH
07
A
U
E
UGPH
15
A
R
J
UGPH
07
B
R
K
Page 6 of 15
25-January-2017
92-42801-UGPH
MODEL
No. Notes
17 Stk Blower Assembly (Includes items 18-22) AS-61697-46 AS-61697-47 AS-61697-58 AS-61697-48 AS-61697-55 AS-61697-48 AS-61697-60
18 Housing AS-61674-19 AS-61674-20 AS-61674-21 AS-61674-20 AS-61674-21 AS-61674-20 AS-61674-22
19 Stk Blower Motor - PSC 51-24070-01 51-22873-01 N/A 51-24070-02 51-25023-01 51-24070-02 N/A
19 Stk Blower Motor - ECM N/A N/A 51-24375-01 N/A N/A N/A 51-24374-06
20 Motor Mount (4) AE-61698-02 AE-61698-02 N/A AE-61698-02 AE-61698-02 AE-61698-02 N/A
ECM Motor Mount Bracket(4) N/A N/A AE-61956-01 N/A N/A N/A AE-61956-01
ECM Motor Mount N/A N/A 70-24104-02 N/A N/A N/A 70-24104-02
21 Stk BlowerWheel 70-22683-01 70-22683-01 70-24254-02 70-22683-01 70-23111-05 70-22683-01 70-23111-20
22 Stk Capacitor - BlowerMotor 43-21298-43 43-21298-42 N/A 43-21298-42 43-21298-43 43-21298-42 N/A
Limit - Heat Assisted (Blower Housing) See Electrical Group
26 Integrated Furnace Control Board (IFC) See Gas Controls
No. Notes
17 Stk Blower Assembly (Includes items 18-22) AS-61697-50 AS-61697-52 AS-61697-85 AS-61697-52 AS-61697-43 AS-61697-52
18 Housing AS-61674-21 AS-61674-22 AS-61674-22 AS-61674-22 AS-61674-22 AS-61674-22
19 Stk Blower Motor - PSC 51-24070-02 51-25023-01 N/A 51-25023-01 N/A 51-25023-01
19 Stk Blower Motor - ECM N/A N/A 51-24376-06 N/A 51-24376-02 N/A
20 Motor Mount (4) AE-61698-02 AE-61698-02 N/A AE-61698-02 N/A AE-61698-02
ECM Motor Mount Bracket(4) N/A N/A AE-61956-01 N/A AE-61956-01 N/A
ECM Motor Mount N/A N/A 70-24104-02 N/A 70-24104-02 N/A
21 Stk BlowerWheel 70-22688-01 70-20602-01 70-24255-01 70-20602-01 70-24255-01 70-20602-01
22 Stk Capacitor - BlowerMotor 43-21298-42 43-21298-43 N/A 43-21298-43 N/A 43-21298-43
Limit - Heat Assisted (Blower Housing) See Electrical Group
26 Integrated Furnace Control Board (IFC) See Gas Controls
HEATING CAPACITY
VARIATION
BLOWER DESIGNATION
AIRFLOW
MODEL
HEATING CAPACITY
VARIATION
BLOWER DESIGNATION
AIRFLOW
UGPH
04
A
U
S
UGPH
10
A
M
E
UGPH
05
A
U
E
BLOWER GROUP
UGPH
10
B
R
J
BLOWER GROUP
UGPH
05
B
M
K
UGPH
10
B
R
M
UGPH
06
A
U
E
UGPH
12
A
R
J
UGPH
07
A
M
G
UGPH
12
A
R
M
UGPH
07
A
U
E
UGPH
15
A
R
J
UGPH
07
B
R
K
Page 7 of 15
25-January-2017
92-42801-UGPH
MODEL
No. Notes
23 Stk Heat Exchanger Assembly AS-61579-01 AS-61579-09 AS-61579-10 AS-61579-08 AS-100560-01AS-100560-01 AS-61579-11
Heat Exchanger Bracket (2) AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02
6 Stk Burner Tube w/Shield - Before F1399
6 Stk,3
7a NOXBurner Insert - Before F0299
7a
7b NOXBurner Retainer Rod - Before F0299 AE-61715-01 AE-61715-01 AE-61715-01 AE-61715-02 AE-61715-02 AE-61715-02 AE-61715-02
7b NOXInsert Retainer - On or After F0299 AE-67872-01 AE-67872-01 AE-67872-01 AE-67872-02 AE-67872-02 AE-67872-02 AE-67872-02
Burner Support - Before F1399 AE-61577-01 AE-61577-01 AE-61577-01 AE-61577-02 AE-61577-02 AE-61577-02 AE-61577-02
Burner Support - On or After F1399 AE-60997-01 AE-60997-01 AE-60997-01 AE-60997-02 AE-60997-02 AE-60997-02 AE-60997-02
8 Burner Support Bracket - Before F1399 (2) AE-61588-01 AE-61588-01 AE-61588-01 AE-61588-01 AE-61588-01 AE-61588-01 AE-61588-01
8 Burner Support Bracket - On or After F1399 (2) AE-61588-02 AE-61588-02 AE-61588-02 AE-61588-02 AE-61588-02 AE-61588-02 AE-61588-02
9 Stk Manifold (w/o Orifices) AS-61663-01 AS-61663-01 AS-61663-01 AS-61663-02 AS-61663-02 AS-61663-02 AS-61663-02
Burner Orifice - Natural Gas See Orifice Selection Chart
Burner Orifice - LP See Orifice Selection Chart
Number of Orifices (2) (2) (2) (3) (3) (3) (3)
No. Notes
23 Stk Heat Exchanger Assembly AS-61579-07 AS-61579-04 AS-61579-04 AS-61579-05 AS-61579-05 AS-61579-06
Heat Exchanger Bracket AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02
6 Stk Burner Tube w/Shield - Before F1399
6 Stk
7a NOXBurner Insert - Before F0299
7a
7b NOXBurner Retainer Rod - Before F0299 AE-61715-03 AE-61715-03 AE-61715-03 AE-61715-05 AE-61715-05 AE-61715-06
7b NOXInsert Retainer - On or After F0299 AE-67872-03 AE-67872-03 AE-67872-03 AE-67872-04 AE-67872-04 AE-67872-05
Burner Support - Before F1399 AE-61577-03 AE-61577-03 AE-61577-03 AE-61577-04 AE-61577-04 AE-61577-05
Burner Support - On or After F1399 AE-60997-03 AE-60997-03 AE-60997-03 AE-60997-04 AE-60997-04 AE-60997-05
8 Burner Support Bracket - Before F1399 (2) AE-61588-01 AE-61588-01 AE-61588-01 AE-61588-01 AE-61588-01 AE-61588-01
8 Burner Support Bracket - On or After F1399 (2) AE-61588-02 AE-61588-02 AE-61588-02 AE-61588-02 AE-61588-02 AE-61588-02
9 Stk Manifold (w/o Orifices) AS-61663-03 AS-61663-03 AS-61663-03 AS-61663-04 AS-61663-04 AS-61663-05
Burner Orifice - Natural Gas See Orifice Selection Chart
Burner Orifice - LP See Orifice Selection Chart
Number of Orifices (4) (4) (4) (5) (5) (6)
HEATING CAPACITY
VARIATION
BLOWER DESIGNATION
AIRFLOW
Burner Assembly - On or After F1399 (See
Note 3)
NOX Burner Insert (Cross X) - On or After
F0299
MODEL
HEATING CAPACITY
VARIATION
BLOWER DESIGNATION
AIRFLOW
Burner Assembly - On or After F1399 (See
Note 3)
NOX Burner Insert (Cross X) - On or After
F0299
UGPH
04
A
U
S
HEAT EXCHANGER, BURNER / MANIFOLD
75-22840-02
(2)
AS-60993-02 AS-60993-02 AS-60993-02 AS-60993-03 AS-60993-03 AS-60993-03 AS-60993-03
AE-61771-01
(2)
AS-67875-01
(1)
UGPH
10
A
M
E
HEAT EXCHANGER, BURNER / MANIFOLD
75-22840-02
(4)
AS-60993-04 AS-60993-04 AS-60993-04 AS-60993-05 AS-60993-05 AS-60993-06
AE-61771-01
(4)
AS-67875-01
(3)
UGPH
05
A
U
E
75-22840-02
(2)
AE-61771-01
(2)
AS-67875-01
(1)
UGPH
10
B
R
J
75-22840-02
(4)
AE-61771-01
(4)
AS-67875-01
(3)
UGPH
05
B
M
K
75-22840-02
(2)
AE-61771-01
(2)
AS-67875-01
(1)
UGPH
10
B
R
M
75-22840-02
(4)
AE-61771-01
(4)
AS-67875-01
(3)
UGPH
06
A
U
E
75-22840-02
(3)
AE-61771-01
(3)
AS-67875-01
(2)
UGPH
12
A
R
J
75-22840-02
(5)
AE-61771-01
(5)
AS-67875-01
(4)
UGPH
07
A
M
G
75-22840-02
(3)
AE-61771-01
(3)
AS-67875-01
(2)
UGPH
12
A
R
M
75-22840-02
(5)
AE-61771-01
(5)
AS-67875-01
(4)
UGPH
07
A
U
E
75-22840-02
(3)
AE-61771-01
(3)
AS-67875-01
(2)
UGPH
15
A
R
J
75-22840-02
(6)
AE-61771-01
(6)
AS-67875-01
(5)
UGPH
07
B
R
K
75-22840-02
(3)
AE-61771-01
(3)
AS-67875-01
(2)
Page 8 of 15
25-January-2017
92-42801-UGPH
No. Notes
25 Stk GasValve - Natural Gas 60-105055-01 60-105055-01 60-22525-11 60-22525-11 60-105055-01 60-105055-01 60-105055-01
25 Stk GasValve - LP See Note 1 See Note 1 See Note 1 See Note 1 See Note 1 See Note 1 See Note 1
26 Stk Integrated Furnace Control Board (IFC) 62-22737-06 62-22694-01 62-22737-07 62-22694-01 62-22694-02 62-22694-03 62-22737-08
Stk FlameSensor 62-23543-01 62-23543-01 62-23543-01 62-23543-01 62-23543-01 62-23543-01 62-23543-01
27 Stk Ignitor - HSI 62-22868-02 62-22868-02 62-22868-02 62-22868-02 62-22868-02 62-22868-02 62-22868-02
Ignitor Bracket - HSI AE-61581-01 AE-61581-01 AE-61581-01 AE-61581-01 AE-61581-01 AE-61581-01 AE-61581-01
Ignitor Shield AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01
LP Conversion Kit:
Stk U.S. Models FP-15 FP-15 FP-15 FP-15 FP-15 FP-15 FP-15
Stk CanadianModels FP-04 FP-04 FP-04 FP-04 FP-04 FP-04 FP-04
No. Notes
25 Stk GasValve - Natural Gas 60-105055-01 60-105055-01 60-23490-01 60-23490-01 60-105055-01 60-105055-01 60-23490-01
25 Stk GasValve - LP See Note 1 See Note 1 See Note 1 See Note 1 See Note 1 See Note 1 See Note 1
26 Stk Integrated Furnace Control Board (IFC) 62-22737-10 62-22694-11 62-22737-08 62-22694-11 62-24044-01 62-24084-02 62-24084-02
Stk FlameSensor 62-23543-01 62-23543-01 62-23543-01 62-23543-01 62-23543-01 62-23543-01 62-23543-01
27 Stk Ignitor - HSI 62-22868-02 62-22868-02 62-22868-02 62-22868-02 62-22868-02 62-22868-02 62-22868-02
Ignitor Bracket - HSI AE-61581-01 AE-61581-01 AE-61581-01 AE-61581-01 AE-61581-01 AE-61581-01 AE-61581-01
Ignitor Shield AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01
LP Conversion Kit:
Stk U.S. Models FP-15 FP-15 FP-15 FP-15 FP-15 FP-15 FP-15
Stk CanadianModels FP-15 FP-15 FP-04 FP-04 FP-15 FP-15 FP-04
No. Notes
25 Stk GasValve - Natural Gas 60-23490-01 60-105055-01 60-23490-01 60-105055-01 60-23490-01 60-24290-01 60-24290-01
25 Stk GasValve - LP See Note 1 See Note 1 See Note 1 See Note 1 See Note 1 See Note 1 See Note 1
26 Stk Integrated Furnace Control Board (IFC) 62-24044-01 62-24133-01 62-24133-01 62-24257-02 62-24257-02 62-24044-01 62-24084-01
Stk FlameSensor 62-23543-01 62-23543-01 62-23543-01 62-23543-01 62-23543-01 62-23543-01 62-23543-01
27 Stk Ignitor - HSI 62-22868-02 62-22868-02 62-22868-02 N/A N/A 62-22868-02 62-22868-02
Stk Ignitor- Silicon Nitride N/A 62-24134-01 62-24134-01 N/A N/A N/A N/A
Ignitor Bracket - HSI AE-61581-01 AE-61581-01 AE-61581-01 N/A N/A AE-61581-01 AE-61581-01
Ignitor Bracket - HSI (Silicon Nitride) N/A AE-61958-01 AE-61958-01 N/A N/A N/A N/A
Ignitor Shield AE-61627-01 AE-61627-01 AE-61627-01 N/A N/A AE-61627-01 AE-61627-01
Stk MiniIgnitor w/Metal Shield N/A N/A N/A 62-24305-02 62-24305-02 N/A N/A
Mini Ignitor Bracket N/A N/A N/A AE-61958-04 AE-61958-04 N/A N/A
LP Conversion Kit:
Stk U.S. Models FP-15 FP-15 FP-15 FP-15 FP-15 FP-15 FP-15
Stk CanadianModels FP-04 FP-15 FP-04 FP-15 FP-04 FP-04 FP-04
No. Notes
25 Stk GasValve - Natural Gas 60-22526-01 60-105055-01 60-105055-01 60-23490-01 60-23490-01 60-105055-01
25 Stk GasValve - LP See Note 2 See Note 1 See Note 1 See Note 1 See Note 1 See Note 1
26 Stk Integrated Furnace Control Board (IFC) 62-24202-01 62-24140-02 62-24136-03 62-24140-02 62-24136-03 62-24140-04
Stk FlameSensor N/A 62-23543-01 62-23543-01 62-23543-01 62-23543-01 62-23543-01
Stk Ignitor- DSI N/A 62-24164-01 62-24164-01 62-24164-01 62-24164-01 62-24164-01
3 Ignitor Bracket- DSI (See Note 3) N/A AE-61885-02 AE-61885-02 AE-61885-02 AE-61885-02 AE-61885-02
Ignitor Shield N/A AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01
Pilot Assembly 62-24203-01 N/A N/A N/A N/A N/A
Pilot Shield AE-61757-01 N/A N/A N/A N/A N/A
Pilot Bracket AE-61658-02 N/A N/A N/A N/A N/A
LP Conversion Kit:
Stk U.S. Models FP-15 FP-15 FP-15 FP-15 FP-15
Stk CanadianModels N/A FP-15 FP-15 FP-04 FP-04 FP-15
MODEL
GAS CODE
(TYPE)
MODEL
GAS CODE
(TYPE)
MODEL
GAS CODE
(TYPE)
MODEL
GAS CODE
(TYPE)
UGPH
BR
(HSI)
UGPH
CX
(HSI)
UGPH
DH
(HSI)
UGPH
DJ
(IP)
UGPH
BS
(HSI)
GAS CONTROLS
UGPH
CY
(HSI)
GAS CONTROLS
UGPH
EF
(HSI)
GAS CONTROLS
UGPH
FD
(DSI)
GAS CONTROLS
UGPH
BT
(HSI)
UGPH
DA
(HSI)
UGPH
EG
(HSI)
UGPH
FE
(DSI)
UGPH
CA
(HSI)
UGPH
DB
(HSI)
UGPH
EM
(HSI-Mini)
UGPH
FF
(DSI)
UGPH
CE
(HSI)
UGPH
DC
(HSI)
UGPH
EQ
(HSI-Mini)
UGPH
FG
(DSI)
UGPH
CV
(HSI)
UGPH
DF
(HSI)
UGPH
EU
(HSI)
UGPH
FU
(DSI)
UGPH
CW
(HSI)
UGPH
DG
(HSI)
UGPH
EV
(HSI)
Page 9 of 15
25-January-2017
92-42801-UGPH
CAUTION: Selection of the correct Natural Gas Orifice requires the following information for the specific installation:
1) Altitude in of the installation (ft.).
2) Average energy content of the Natural Gas fuel from the local supplier (BTU/cu. ft.).
For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-59 and the latest edition of the
National Fuel Gas Code Handbook, or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1.
CAUTION:This information is provided for replacement purposes only. Conversion for operation at High Altitude must be done using the kit specified
on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is based on 25,000 BTU/HR per burner.
NOTE: Factory installed orifices are calculated and sized based on a Natural Gas heating value of 1075 BTU/cu. ft. and an elevation of 0 - 3000 ft.
Elevation (ft.)
EnergyValue
(BTU/cu. ft.)
850 62-22175-38 62-22175-39 62-22175-40 62-22175-41 62-22175-41 62-22175-42 62-22175-42 62-22175-43
900 62-22175-40 62-22175-41 62-22175-42 62-22175-42 62-22175-42 62-22175-43 62-22175-43 62-22175-44
975 62-22175-41 62-22175-42 62-22175-42 62-22175-42 62-22175-43 62-22175-43 62-22175-44 62-22175-44
1075 62-22175-42 62-22175-42 62-22175-43 62-22175-43 62-22175-43 62-22175-44 62-22175-44 62-22175-45
1170 62-22175-43 62-22175-44 62-22175-44 62-22175-44 62-22175-45 62-22175-45 62-22175-46 62-22175-47
CAUTION: Selection of the correct LP Orifice requires the altitude of the specific installation (ft.).
For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-59 and the latest edition of the
National Fuel Gas Code Handbook (NFG), or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1.
CAUTION:This information is provided for replacement purposes only. Conversion to LP or for operation at High Altitude should be done the kit(s)
specified on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is based on 25,000 BTU/HR per burner. Also, the chart is developed using the specified pressure setting of 10 in. water column
instead of the 11.0 in water column used by the NFG and CANB149.1.
NOTE: Orifices supplied in the LP Conversion Kit are calculated and sized based on an altitude of 0 - 4000 ft.
Elevation (ft.) Orifice
0 - 2000 62-22175-54
2001 - 3000 62-22175-54
3001 - 4000 62-22175-54
4001 - 5000 62-22175-54
5001 - 6000 62-22175-54
6001 - 7000 62-22175-54
7001 - 8000 62-22175-55
8001 - 9000 62-22175-55
9001 - 10000 62-22175-55
0 - 1999 2000 - 2999 3000 - 3999 4000 - 4999 5000 - 5999 6000 - 6999 7000 - 7999 8000 - 8999
80% GAS FURNACE - ORIFICE SELECTION CHART - NATURAL GAS
80% GAS FURNACE - ORIFICE SELECTION CHART - LP
Page 10 of 15
25-January-2017
92-42801-UGPH
Exploded View
Page 11 of 15
25-January-2017
92-42801-UGPH
Blower Assembly
Page 12 of 15
25-January-2017
92-42801-UGPH
Burner Assembly
Page 13 of 15
25-January-2017
92-42801-UGPH
NOX Insert Assembly after F0299
Page 14 of 15
25-January-2017
92-42801-UGPH
NOTES
Stk It is recommended that stock be maintained for this part.
N/A Not Applicable
1 Order Gas Valve for Natural Gas along with LP Conversion Kit. (If the original valve has been replaced, order the
spring kit for the replacement valve.)
2 Order specified LP Conversion Kit
3 For units with DSI ignition, and date codes before F1506, it is recommended that a new Igniter Bracket
(AE-61885-02, with three mounting holes) be ordered.
P.O. Box 17010