MODEL RXGY - G01 (3”) (SP20286) SIDE WALL VENT KIT
DIRECT VENT:
NON-DIRECT VENT:
FOR FURNACE MODELS NOT LISTED SEE UNIT INSTALLATION INSTRUCTIONS OR 92-102340-01 FOUND ON RHEEMOTE.NET /PTS/RXGY
FURNACE AND TANKLESS WATER HEATER
FURNACE ONLY
FOR USE WITH MODELS: R92PA, R95PA, R95TA, R96PA, R96VA & R98VA
KIT CONTENTS:
• Vent Cap
• Vent Plate
• 4- # 8 pan head screws 2” long” SMS
type A18-8 stainless steel.
• 4- #8 pan head screws 1” long , SMS
type A18-8 stainless steel.
This manual covers the installation of the RXGY-G01 side wall vent kit.
The RXGY-G01 is intended for:
Direct Venting:
Non-Direct Vent:
The RXGY-G01 Vent Kit can be used for all above listed
furnace models. Refer to CondensingTankless water heater
manufacturer’s installation instructions for model exclusions!
IMPORTANT:
furnace and tankless water heaters
furnaces only
!
WARNING
THIS VENT KIT MUST BE INSTALLED BY A QUALIFIED SERVICE TECHNICIAN. CODES AND LOCAL UTILITY
REQUIREMENTS GOVERNING THE INSTALLATION OF GAS FIRED EQUIPMENT, WIRING, PLUMBING, AND FLUE
CONNECTIONS MUST BE ADHERED TO. IN THE ABSENCE OF LOCAL CODES, THE INSTALLATION MUST CONFORM
TO THE NATIONAL FUEL GAS CODE ANSI Z223.1 “LATEST EDITION,” OR CSA-B149 INSTALLATION CODES.
THE LATEST CODE MAY BE OBTAINED FROM CSA-INTERNATIONAL, 8501 EAST PLEASANT VALLEY ROAD,
CLEVELAND, OHIO 44131 OR CSA-INTERNATIONAL, 178 REXDALE BLVD., TORONTO, ONTARIO, CANADA M9W, 1R3
!
WARNING
DO NOT OPERATE THE FURNACE OR TANKLESS WATER HEATER WITHOUT THE SIDE WALL CAP IN PLACE AS
RECIRCULATION OF COMBUSTION PRODUCTS MAY OCCUR. WATER MAY ALSO COLLECT INSIDE THE COMBUSTION AIR PIPE AND FLOW TO THE BURNER ENCLOSURE. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN
PRODUCT DAMAGE OR IMPROPER OPERATION, PERSONAL INJURY OR DEATH.
!
WARNING
THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE
ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN
IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE, POSSIBLY RESULTING IN FIRE, CARBON
MONOXIDE POISONING, EXPLOSION, PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
DO NOT DESTROY THIS MANUAL. PLEASE READ CAREFULLY AND KEEP
IN A SAFE PLACE FOR FUTURE REFERENCE BY A SERVICEMAN.
92-102005-02-00

VENT KIT INSTALLATION OPTIONS
INSTALLATION –RXGY- G01 Side Wall Vent
This termination is for horizontal venting only.
Important: Avoid installingon the prevailing winter wind side of the structure
Note: Multi-venting-No common venting. Refer to furnace I & O for instructions.
NOTE:
Install the vent and air intake piping into the vent plate openings. Seal all gaps between the pipes and wall.
Be Sure to Use Silicone Sealant to seal the vent pipe to the vent cap to permit field disassembly for annual inspection and cleaning.
Also seal all pipe penetrations in wall. To prevent possibility of condensate freeze-up or recirculation, do not install vent kits one
above the other.
Note : The Vent illustration in Figures 1 & 2 can be used for Non-direct furnace vent termination also.
FIGURE 2
TYPICAL INSTALLATION
3 “ Pipe
COMBUSTION AIR
Refer to Installation Instructions for clearances.
12” MINIMUM TO OVERHANG
VENT
Note:
Vent should protrude a maximum of 2-1/4” beyond
vent plate. Air intake should protrude a maximum
of 1 inch beyond vent plate. Use the vent plate as a
template to locate vent, combustion air and (4)
mounting holes. Observe minimum clearances.
Cut (2) 3-7/8” diameter holes for the vent and
combustion air openings.
Drill (4) 3/16” diameter holes for inserting the
plastic anchors into the wall.
Attach the vent plate to the wall with (4) - 2” long
stainless steel screws.
Assemble the vent cap to the vent plate . Insert the
(4) 1” long stainless steel screws into the vent cap screw
hole openings and securley attach the vent cap to the
vent plate. Seal all wall cavities.