Rheem RXIH-AB12A, RXIH-AB17A Owner's Manual

Place bar code here
RXIH-AB12A and RXIH-AB17A By-Pass Flow-Through Humidifiers
with Antimicrobial
OWNER’S GUIDE
69-2297-01
RXIH-AB12A AND RXIH-AB17A BY-PASS FLOW-THROUGH HUMIDIFIERS
IMPORTANT
Please read these instructions and keep them in your records.

OPERATING YOUR HUMIDIFIER

Humidifiers are controlled by the Convertible Humidity Control. The convertible humidity control is installed either on an interior wall in the living area, or on the return air duct. Choose the humidity control setting using the combination relative humidity/outdoor temperature setting scale on your humidity control dial. Match the dial setting to the outdoor temperature for optimizing the humidity level while reducing moisture condensation on your windows. The table below can also be used to adjust humidity control to the recommended setting.
M29011
At Outside
Temperature
-20°F (-29°C) 15 +10°F (-12°C) 30
-10°F (-23°C) 20 +20°F (-7°C) 35
0°F (-18°C) 25 Above 20°F (-7°C) 40
NOTE: As outside temperature drops, the recommended humidity control setting is
lowered to adjust for effects of dewpoint. These settings should reduce accu­mulation of moisture and ice on your windows and other areas of your home.
Some indoor activities such as cooking, showering and clothes drying can cause excessive levels of humidity and start the accumulation of moisture on your windows.
NOTE: If this condition persists for more than a few hours, set the humidity control to
the lowest setting to turn off the humidifier. If the condition does not improve, ventilate your home to remove the moisture.
Recommended Control Setting
At Outside
Temperature
Recommended Control Setting

HOW YOUR HUMIDIFIER WORKS

Your humidifier uses the principle that vapor (evaporated water) is created when warm air blows over a water soaked area. As the vapor circulates, the relative humidity rises.
Your humidity control monitors the relative humidity and activates the humidifier accordingly. The humidifier has a water supply that dispenses water evenly over the antimicrobial humidifier pad. The warm dry air, from the furnace, passes over the humidifier pad and picks up the moist air to circulate it throughout your home.
69-2297—01 2
RXIH-AB12A AND RXIH-AB17A BY-PASS FLOW-THROUGH HUMIDIFIERS
WARNING
A
Humidified air feels warmer and more comfortable so you may be able to lower your thermostat heating setpoint, which saves money on your heating fuel bills. The end result is that your humidifier gives you a cleaner, more comfortable environment that is also energy efficient.

MAINTAINING YOUR HUMIDIFIER

A regular maintenance program prolongs the life of your humidifier and provides a more comfortable home. Frequency of cleaning depends on the condition of your water. You can use either hard or soft water in your humidifier, but hard water mineral deposits are more difficult to clean than soft water deposits. For optimum performance, replace the antimicrobial pad once a year. Use the following procedure to clean your humidifier.
Serious Personal Injury Hazard. Can cause electrical shock and injury from moving parts.
Disconnect power and shut off water supply before removing cover.
IMPORTANT:
Never oil any part of the humidifier.

Every 1 to 3 Months (Depending on Water Quality)

1. Disconnect power and turn off humidifier water supply.
2. Remove the humidifier cover by unplugging the connector and loosening the thumb screw. Grasp the cover near the bottom and pull toward you.
3. Remove humidifier pad assembly from humidifier by grasping top of tray and pulling it toward you.
4. Lift the tray off the pad.
5. Gently pinch water nozzle
catches inward until you can lift water nozzle off tray.
WATER DISTRIBUTION TRAY
WATER FEED NOZZLE
NTIMICROBIAL
HUMIDIFIER PAD ASSEMBLY
HUMIDIFIER HOUSING
WATER FEED TUBE
SIDEWALL
COVER
BYPASS SIDEWALL
M29012