OFFER ENERGY-EFFICIENT HOT
WATER FOR YOUR CUSTOMER’S
HOME OR BUSINESS
Page 2
Why Rheem® Tankless Gas Solutions?
WHY TANKLESS?
TANKLESS FEATURES
• Continuous hot water
• High energy efficiency
• Compact, space saving design
• Self diagnostic digital thermostat
• Precise temperature control
• No hot water storage
• Low operating costs
• High altitude installations to
10,000 ft – some models
• Low NOx emissions – all models
• Indoor and outdoor models
available
TANK TYPE FEATURES
• Low first cost
• Low installation cost
• No electricity required
• Large variety of sizes available
• Flow rates of 12gpm and up
• High altitude installations to
10,000 ft.
• Low NOx emissions – some
models
WHY RECIRCULATION?
By circulating hot water from the tankless unit, through the
home’s plumbing it can be ready at the faucet when needed.
Benefits include:
•
Hot water without the wait or the waste
•
On-demand or timer based pump activation means hot water ready at the
tap when you need it
•
The average household can save up to 12,000 gallons of water per year
• Meets regional water saving regulations
1
WHY CONNECTED WATER HEATERS?
Any Rheem tankless water heater from 2010 to
present
home integrated features, including:
• Water leak detection and system shut off (indoor models only)
• Mobile alerts for notifications/maintenance reminders
• Mobile gas and water usage reports
• Integration with NEST & WINK smart home systems
1
Savings per News B ulleti n relea sed by the Un ited States Depa rtme nt of Energ y / Oak Rid ge Natio nal Laborator y, November 20 02 on study o n water and
energ y savings in resid ential h omes usi ng Hot Water R ecirculating S ystem.
2
Excluding -RH models
2PRODUCT GUIDE | TANKLESS GAS WATER HEATERS3PRODUCT GUIDE | TANKLESS GAS WATER HEATERS
2
can be connected to EcoNet for smart
Page 3
Selecting the
Right Solution
is as Easy
as 1, 2, 3
1 Consider customer location
2 Assess their hot water needs
3 Review inlet temperature and
recommend the best model for
your customer
HELP YOUR
CUSTOMERS
START SAVING
TODAY
Learn more at
rheem.com/
tanklessinnovation
or ask your local
distributor
Mid-Efficiency
Models rated at:Indoor Model #
160,000 BTU/h
180,000 BTU/h
199,900 BTU/h
RTG-70DVLN-1
RTG-70XLN-1
RTG-84DVLN-1
RTG-84XLN-1
RTG-95DVLN-1
RTG-95XLN-1
High Efficiency
Models rated at:Indoor Model #
157,000 BTU/h
180,000 BTU/h
199,900 BTU/h
RTGH-84DVLN-1
RTGH-84XLN-1
RTGH-90DVLN-1
RTGH-90XLN-1
RTGH-95DVLN-1
RTGH-95XLN-1
High Efficiency with
Built-in Recirculation
Models rated at:Indoor Model #
180,000 BTU/h RTGH-RH10DVL
Inlet Temperature 37-47OInlet Temperature 47-57OInlet Temperature 57-62OInlet Temperature 62-77O
Average
GPM
Approximate
Usage
Average
GPM
Approximate
Usage
Average
GPM
Approximate
Usage
Average
GPM
Approximate
Usage
3.54.04.55.5
3.84.35.16.1
4.14.75.56.6
Inlet Temperature 37-47OInlet Temperature 47-57OInlet Temperature 57-62OInlet Temperature 62-77O
Average
GPM
Approximate
Usage
Average
GPM
Approximate
Usage
Average
GPM
Approximate
Usage
Average
GPM
Approximate
Usage
3.94.35.06.0
4.54.95.86.9
5.05.56.47.7
Inlet Temperature 37-47OInlet Temperature 47-57OInlet Temperature 57-62OInlet Temperature 62-77O
Average
GPM
Approximate
Usage
Average
GPM
Approximate
Usage
Average
GPM
Approximate
Usage
Average
GPM
Approximate
Usage
4.35.05.86.9
USAGE KEY
Faucet
Flow rate
of 2.0 GPM
Inlet Temperature:
The temperature of cold
water before it enters your
water heater.
GPM:Gallons Per Minute
Approximate Usage:
The number of faucets
and/or showers this model
will serve based on a
temperature setting of 120˚F.
Flow rates vary depending on
temperature of incoming cold
water and water heater set
temperature.
Shower
Flow rate
of 2.5 GPM
199,000 BTU/h RTGH-RH11DVL
Models with DV are Indoor Direct Vent units. Models with X are Outdoor units.
Replace the N (Natural Gas) in the model numbers with a P for Liquid Propane models.
* Base d on simultaneo us showers using a 2.5 GP M flow rate & f aucets using a 2.0 GPM flow rate, both p re-mix ed with co ld water li ne to 105°F. Flow rates vary depending o n tempe rature of incoming cold water
and water h eater set te mperature. Number of showers an d faucets vary depending on max imum flow rates of sh ower hea ds and fau cets. Usa ge can inc lude oth er appliances i nstead of s howers a nd fauce ts.
4.85.56.47.7
Page 4
®
Rheem® Prestige
Series with Built-in Recirculation
High Efficiency Tankless Gas Water Heating Solutions
ENERGY
SAVINGS
UP TO
$
1,10 0
VENT
UP TO
50 FT.
WITH
2 INCH
PVC
2
BUILT-IN RECIRCULATION PROVIDES INSTANT HOT WATER
AT THE TAP
Available in indoor direct vent models, the new Rheem Ultra Low NOx, High Efficiency
Condensing Tankless series with built-in recirculation saves time on install with built-in
pump and reduces water waste.
1
AND REDUCES WATER WASTE
LOWER INSTALLATION COSTS
Installs with 2" and 3" Schedule 40 PVC venting, which is easier to work with
and lower cost than stainless steel, saving you money and time
BUILT-IN RECIRCULATION PUMP
Circulates hot water from the water heater and returns the cold water that
would normally run down the drain, back through the plumbing, allowing hot
water to be ready at the tap without any cold water being wasted
Energy Factor
Venting Type
Dimensions
Weight
Warranty
Ultra Low NOx
High Altitude
.94 UEF
Vents with Schedule 40 PVC, CPVC, PP
28.7" H x 17.3" W x 14.8" D
85 lbs.
Heat Exchanger: 12 Years Residential; 5 Years Commercial
Parts: 5 Yea rs
Labor: 1 Year
All Natural Gas Models
Up to 10,000 ft.
Description
Indoor Direct Vent – Nat. GasRTGH-RH10DVLNRTGH-RH11DVLN
Indoor Direct Vent – LP. GasRTGH-RH10DVLPRTGH-RH11DVLP
1
Individual results may vary.
2
Based on compar ison aga inst 50-gallon t ank typ e model wi th like fu el type. Savings based on N atural gas model; Sa vings hig her for l iquid pr opane mo dels. 2Individual results may vary.
4PRODUCT GUIDE | TANKLESS GAS WATER HEATERS5PRODUCT GUIDE | TANKLESS GAS WATER HEATERS
180,000
BTU Max.
199,000
BTU Max.
Page 5
INDOOR DIRECT VENT
Exhaust
(PVC Venting)
Air Intake
(PVC Venting)
SAVE TIME
Vents with PVC
1
Vents up to 50 ft. with 2" and up to 100 ft. with 3" PVC saving time
and money
Common Venting
2
Vent two units together for fewer wall penetrations
Power Venting
3
Vent single units using room air intake for more flexible installs
Half-Inch Gas Line Compatible
4
Convert homes easily from tank to tankless without the need to
upgrade existing gas lines up to 24 ft
Perfect for Replacement
5
With dedicated programming for installs without a
return line, a crossover valve can be used to turn
the existing cold water pipe into a return
2
1
BOTTOM VIEW
Connection Cable
Access
Cold Water Inlet
Inlet Filter
INSTALL MORE
Instant Hot Water
6
Recirculation pump circulates hot water from the water heater
through the home, keeping it ready at the tap when needed
Save Water
7
Save up to 12,000 gallons of water wasted down the drain each
year waiting for it to get hot
Timer-Based Pump Activation
8
Option to program pump activation at specific times of day to make
sure hot water is always ready when needed
Auto-Learn Programming
9
This setting will track water usage over a period of time and
auto-program recirculation to meet hot water needs at peak times
Preheat Mode & Internal Recirculation
10
Pumping water through the heat exchanger in an internal loop,
the unit can maintain consistent performance and prevent cold
water bursts
Water & Gas Leak Detection
11
Will shut down the unit and provide an error code
3
4
Hot Water Outlet
Dedicated Return
Condensate Drain
1
For all venting installations, refer to ANSI Z223.1/NFPA 54, as well as applicable local building codes.
2
Based on Rheem testing of 1/2" gas line with gas supply of 7" w.c. up to 24'; Installation conditions vary; Consult the Rheem® Use and Care Manual, the Rheem® Gas Piping Facts brochure (TK-GPF-12), the
National Fuel Gas Code (NFPA 54, ANSI Z223.1), and any other local gas codes when installing a Rheem Tankless Water Heater.
3
Individual results may vary.
4
Savings per News B ulleti n relea sed by the Un ited States Depa rtme nt of Energ y / Oak Rid ge Natio nal Laborator y, November 20 02 on study o n water and e nergy sa vings in residential hom es using H ot
Water Recir culating Sy stem.
Gas
Page 6
®
Rheem® Prestige
Series
High Efficiency Tankless Gas Water Heating Solutions
MAXIMUM WATER AND ENERGY SAVINGS,
PLUS KEEPS INSTALL COSTS TO A MINIMUM
Available in both indoor and outdoor models, Rheem Ultra Low NOx, High Efficiency
Tankless solutions are loaded with features to save on installation costs, time
and servicing—while saving homeowners more money, water and space.
LOWER INSTALLATION COSTS
Installs with 2", 3" and 4" Schedule 40 PVC venting, which is easier to work
with and lower cost than stainless steel, saving you money and time
BUILT-IN CONDENSATE
NEUTRALIZER
Safely dispose of condensate without extra installation cost and time
ENERGY
SAVINGS UP TO
$
1,100
Energy Factor
Venting Type
Dimensions
Weight
Warranty
Ultra Low NOx
.93 UEF
Vents with Schedule 40 PVC
27-1/2" H x 18-1/2" W x 9-3/4" D
82 lbs.
Heat Exchanger: 12 Years Residential; 5 Years Commercial
Parts: 5 Yea rs
Labor: 1 Year
All Natural Gas Models
NEW MODELS WITH ECONET INCLUDED
Description
EcoNet WiFi Included: Indoor Direct Vent – Nat. Gas
1
EcoNet WiFi Included: Indoor Direct Vent – LP. Gas
Based on compar ison aga inst 50-gallon t ank typ e model wi th like fu el type. Savings based on N atural gas model; Sa vings hig her for l iquid pr opane mo dels.
6PRODUCT GUIDE | TANKLESS GAS WATER HEATERS7PRODUCT GUIDE | TANKLESS GAS WATER HEATERS
157,000
BTU Max.
180,000
BTU Max.
199,900
BTU Max.
Page 7
INDOOR DIRECT VENT
3
Air Intake
(PVC Venting)
2
Exhaust
(PVC Venting)
1
10
8
SAVE TIME
PVC Venting Compatible
1
Vent with 2", 3" and 4" PVC, saving time and money
Easy To Service
2
Access all parts of the heater with just a Phillips-head screwdriver
Built-In Condensate Neutralizer
7
6
5
9
4
3
Industry First!
Safely dispose of condensate without extra installation cost
and time
Half-Inch Gas Line Compatible up to 24 ft.
4
Saves money and time on installation to an existing system
Freeze Protection
5
Industry Best!
Ceramic heaters on copper pipes protect from 40ºF to -30ºF,
allowing outdoor installation
1
Condensate
Neutralizer
Discharge
Outlet
Condensate
Neutralizer
Discharge
Outlet
3/4" Hot
Water
Outlet
External
Connection
for Remote
Control Cable
OUTDOOR
3/4" Cold
Water
Inlet
3/4" Gas
Connection
INSTALL MORE
Hot Start Programming
6
RHEEM EXCLUSIVE
Minimizes cold water bursts by staying in ready-fire state for
back-to-back hot water needs
Can save up to 1,100 gal/year by reducing water flow at tap until
6
2
set temperature is achieved (optional)
Low Flow Activation
9
Industry Best!
3
10
8
5
9
4
Minimum flow rate of .26 GPM and activation flow rate of .40 GPM
ensures hot water in low demand situations
Six Stage Modulating Burner
10
Tight control over burner energy efficiency
EcoNet® Enabled
11
All models from 2010 to present can connect to
EcoNet mobile app via Tankless EcoNet
3/4" Hot
Water
Outlet
External
Connection
for Remote
Control Cable
3/4" Cold
Water
Inlet
3/4" Gas
Connection
Accessory Kit (REWRA630TWH)
1
Based on Rheem testing of 1/2" gas line with gas supply of 7" w.c. up to 24'; Installation conditions vary; Consult the Rheem® Use and Care Manual, the Rheem® Gas Piping Facts brochure (TK-GPF-12),
the National Fuel Gas Code (NFPA 54, ANSI Z223.1), and any other local gas codes when installing a Rheem Tankless Water Heater.
Page 8
Rheem® Classic Plus® Series
Mid-Efficiency Tankless Gas Water Heating Solutions
ENERGY EFFICIENCY AND SAFETY FEATURES,
PLUS SAVINGS ON INSTALLATION
Available in both indoor and outdoor models, our Mid-Efficiency solutions are not only
designed to save costs and time on installation and service, but also offer smart energy
savings and safety features customers love.
ENERGY
SAVINGS UP TO
1
$
800
Energy Factor
Venting Type
Dimensions
Weight
Warranty
Ultra Low NOx
.82 UEF: Indoor
.81 UEF: Outdoor
Vents with 3"/5" stainless steel concentric vent
system, (sold separately)
25-5/8" H x 13-7/8" W x 9-7/8" D (Indoor)
23-5/8" H x 13-7/8" W x 8-7/8" D (Outdoor)
54 lbs.
Heat Exchanger:
12 Ye ars Residential;
5 Years Commercial
Parts: 5 Yea rs
Labor: 1 Year
All Natural Gas Models
NEW MODELS WITH ECONET INCLUDED
Description
EcoNet WiFi Included:
Indoor Direct Vent – Nat. Gas
EcoNet WiFi Included:
Indoor Direct Vent – LP. Gas
EcoNet WiFi Included:
Outdoor – Nat. Gas
EcoNet WiFi Included:
Outdoor – LP Gas
199,900
BTU Max.
RTG-95DVELN-1
RTG-95DVELP-1
RTG-95XELN-1
RTG - 9 5XELP-1
MODEL
WITH BUILT-IN
RECIRCULATION
PUMP FOR
FASTER HOT
WATER AT
THE TAP
RECIRCULATION
SAVES UP TO
12,000
GALLONS
WATER/YEAR
Description
Indoor Direct Vent – Nat. GasRTG-70DVLN-1RTG-84DVLN-1RTG-95DVLN-1
Indoor Direct Vent – Nat. Gas
with Recirculation Pump
Indoor Direct Vent – LP. GasR TG-70DVLP-1RTG-84DVLP-1RTG -9 5 DVLP-1
Indoor Direct Vent – LP Gas
with Recirculation Pump
Based on compar ison aga inst 50-gallon t ank typ e model wi th like fu el type. Savings based on N atural gas model; Sa vings hig her for l iquid pr opane mo dels.
2
Savings per News B ulleti n relea sed by the Un ited States Depa rtme nt of Energ y / Oak Rid ge Natio nal Laborator y, November 20 02 on study o n water and e nergy sa vings in residential hom es using H ot Water
Recirculating Syste m.
8PRODUCT GUIDE | TANKLESS GAS WATER HEATERS9PRODUCT GUIDE | TANKLESS GAS WATER HEATERS
Page 9
INDOOR DIRECT VENT
Exhaust
SAVE TIME
Easy To Service
1
Access all parts of the heater with just a Phillips-head screwdriver
Half-Inch Gas Line Compatible up to 24 ft.
2
1
Saves money and time on installation to an existing system
Freeze Protection
3
6
Industry Best!
Ceramic heaters on copper tubes protect from 40ºF to -30ºF
allowing outdoor installation
1
9
5
Maintenance Notification Setting
4
RHEEM EXCLUSIVE
Alerts homeowners after 500 hours of use (about one year -
1½ years) to call for service extending the life of the water heater
(optional)
7
4
3
Remote control included with all
tankless gas water heaters
8
2
Condensate
Neutralizer
Discharge
Outlet
3/4" Hot
Water
Outlet
OUTDOOR
External
Connection
for Remote
Control Cable
3/4" Cold
Water
Inlet
3/4" Gas
Connection
INSTALL MORE
Hot Start Programming
5
RHEEM EXCLUSIVE
Minimizes cold water sandwich by staying in ready-fire state for
back-to-back hot water needs
Can save up to 1,100 gal/year by reducing water flow at tap until
set temperature is achieved (optional)
9
Low Flow Activation
8
Industry Best!
7
3
8
2
Condensate
Neutralizer
Discharge
Outlet
1
Based on Rheem testing of 1/2" gas line with gas supply of 7" w.c. up to 24'; Installation conditions vary; Consult the Rheem® Use and Care Manual, the Rheem® Gas Piping Facts brochure (TK-GPF-12),
the National Fuel Gas Code (NFPA 54, ANSI Z223.1), and any other local gas codes when installing a Rheem Tankless Water Heater.
3/4" Hot
Water
Outlet
External
Connection
for Remote
Control Cable
3/4" Cold
Water
Inlet
3/4" Gas
Connection
Minimum flow rate of .26 GPM and activation flow rate of .40 GPM
ensures hot water in low demand situations
Six Stage Modulating Burner
9
Tight control over burner energy efficiency
EcoNet® Enabled
10
All models from 2010 to present can connect to
EcoNet mobile app via Tankless EcoNet
Accessory Kit (REWRA630TWH)
Page 10
Rheem® Commercial Tankless Solutions
DELIVERING ENERGY SAVINGS,
FLEXIBILITY & SUPPORT
Introducing a dedicated water heating solution
for businesses with all the Rheem tankless
advantages, plus:
• Thermal Efficiency of up to 96%
• Built-in maximum temperature setting of 185°F
• Common venting options for indoor natural
gas models
• Manifold control models for linking up to 20
units with no added accessories
• Service valves included
Now Manifold
Control Ready &
Common Vent
Compatible
DescriptionCommercial Tankless
Manifold Control Ready
To create a load sharing system, the factory-installed
manifold controller allows up to 20 units to be
connected–in daisy chain fashion– via an included
cable. Once connected, the system is load balanced,
which creates redundancy–so if one heater goes
down, the business can stay up and running.
Commercial Tankless
WITH Manifold Control
Indoor Direct Vent – Nat. Gas
Indoor Direct Vent – LP GasRTGH-C95DVLP
Outdoor – Nat. GasRTGH-C95XLN
Outdoor – LP GasRTGH-C95XLP
1
Accord ing to a 2016 survey of tankle ss contra ctors by Ha nover Research o n behal f of Rhee m.
10 PRODUCT GUIDE | TANKLESS GAS WATER HEATERS11PRODUCT GUIDE | TANKLESS GAS WATER HEATERS
RTGH-C95DVLN
RTGH-CM95DVLN
RTGH-CM95DVLP
RTGH-CM95XLN
RTGH-CM95XLP
Page 11
CONTROL YOUR TANKLESS SYSTEM
190 GPM
Number of Heaters in a Manifold
Rheem’s new line of commercial tankless solutions
includes four options with a factory-installed manifold
control translator for connecting up to 20 units – in
daisy-chain configuration – via included manifold
control cable. Once manifolded, the tankless water
heaters balance the workload as a system.
LESS DOWNTIME
Having multiple units working together creates
redundancy, so if one tankless water heater goes
down, your customer’s business stays up
and running.
Tankless Multi-Unit Flow Rates
Manifold
QTY
Total System BTU
based on
199,900 Btu per Unit
3545506070778090100110120140
Total System Gallons Per Minute (GPM) - Per Temperature Rise (∆T)
for use with RTG & RTGH series (excluding -RH models)
Cosmetic Pipe Covers
Enhance the installation of the water heater and provides
protection from tampering and weather.
• RTG20227 - Fits RTGH DV or X Series
• RTG20217DVG - Fits RTG DV Series
• RTG20217XG - Fits RTG X Series
Outdoor Recess Box
Mount an outdoor unit into the wall, flush with the
outside of the home.
• RTG20226 - Fits RTGH X Series
• RTG20218 - Fits RTG X Series
• RTG20253 - For Stucco - Fits RTGH X Series
Remote Controls
• RTG20006DW - UMC-117 - Main
• RTG20006DU - USC1-117 - Bath
One rem ote is
includ ed with
each unit
• RTG20006DV - USC2-117 - Second Bath
• RTG20009-1 - 10' - Thermostat Wire 1 pair 18AWG
SEE THE
TANKLESS PARTS
AND ACCESSORIES
CATALOG FOR
MORE OPTIONS
ECONET® SMART HOME
EcoNet® WiFi Kit
Provides remote access to tankless unit from
mobile app
•REWRA630TWH – EcoNet Translator
and WiFi Kit for tankless water heaters
CONNECTING MULTIPLE UNITS
EZ-Link™ Cable
Connect two tankless water heaters to
operate as a single unit
• RTG20040 - 6-ft. Cable with Connectors
and Support Clamps
MIC-6 Manifold Controller System
Kit mounts inside a single tankless unit and connects to up to 5 additional units for a total of 6.
• RTG20213A - Includes (1) 1-ft. control cable and
(1) 6-ft. control cable
MIC-185 Manifold Controller System
• RTG20126A - Manifold and control up to 6 tankless
models. Includes installation cabinet for indoor or
outdoor applications
MICS-180 Manifold Controller Expansion Card
• RTG20126B - Add on to the MIC-185 to expand up
to 20 unit systems. Mounts inside MIC-185 cabinet.
Includes cables to connect to the MIC-185 board
Recirculation Pump Kit – Timer Based
• AP17920 - Kit contains: (1) Taco Genie® 0015
recirculation pump with internal check valve,
(2) Stainless steel flanges and flange gaskets,
(4) 7/16" – 14 Bolts
Manifold Control Cables (Type K)
One cable required for each tankless unit connected to
the MIC 180.
• RTG20126C - Cable - MIC-K-16, 16-ft. Control Cable
12 PRODUCT GUIDE | TANKLESS GAS WATER HEATERS
Recirculation Pump Kit – On Demand
• AP18403 - On demand pump kit - standard
• AP18537 - On demand pump kit - under sink
Page 13
Rheem® Parts & Accessories
for use with RTG-RC models with built-in recirculation
Push Button
Wired Push Button
For On Demand
Activation or
Recirculation Pump
• SP20863
Remote Receiver
and Transmitter Kit
Wireless Remote
Transmitter Kit For On
Demand Activation of
Recirculation Pump
• SP20861
Rheem® Parts & Accessories
for use with RTGH-RH models with built-in recirculation
Condensate
Neutralizer
For safe disposal of
condensate (check
your local plumbing
codes)
• SP12151
On-Demand
Activation
Accessory
Converts timer based
pump to on-demand
activation, with
included wall switch
• RTG20941
Motion Sensor
Kit
Motion Sensor Kit
For On Demand
Activation of
Recirculation Pump
• SP20862 -
Quick Connect
Cable
For 2 unit manifolding
(Coming Soon)
• SP20892
PARTS AND ACCESSORIES FOR USE WITH ANY TANKLESS MODEL
AllClear™ Water
Treatment System
Combat hard water and
scale build up
• RTG20251 - AllClear
Water Treatment
System
• RTG20252 -
Replacement Cartridge
™
NEW EZ-RACK™ KIT
Mounts easily to a wall or free standing.
Additional kits to hold any number of units.
Assembles easily on the jobsite in under 10 minutes.
• RTG20304
Flush Kit
Connects to the service
valves for an easy way to
de-scale your tankless
water heater.
• RTG2 0214 - Includes
pump, hoses and
5-gallon bucket
Service Valves
Webstone®-Brand
• RTG20220AB - Clean
Brass for Low Lead
Code - Includes cold
and hot water set and
pressure relief valve
NEW
Crossover Valve
Converts cold water line
into recirculation return for
use with built-in recirculation
models or accessory pumps
•RTG20285
13PRODUCT GUIDE | TANKLESS GAS WATER HEATERS
Page 14
Tankless Venting
3"/5" Concentric Vent System
PVC Vent System
Outdoor
Complete Your Installation with Rheem® Venting Components
and Accessories
VENTING OPTIONS
AND INSTALLATIONS
All indoor tankless units must be vented
to the outdoors using manufacturer
approved venting material.
Venting for Condensing Tankless RTGH Series
PVC Termination Kits| Allow for an aesthetic and easy installation
Horizontal or Vertical
Concentric Termination
Combines a two-pipe vent
system to a single, concentric
through-the-wall or roof
penetration. Designed for
two-pipe direct vent, fits PVC
or CPVC venting. Installed
dimensions: 39"H x 7-1/4"D
• SP20245 - For 3" PVC
Venting
Horizontal Vent
Termination
Low profile design for twopipe direct vent, fits PVC
or CPVC venting. Installed
dimensions:
11-3/4"W x 8"W x 2-1/2"D
• SP20286 - For 3" PVC
Venting
• SP20285 - For 2" PVC
Venting
Venting for Mid Efficiency Tankless RTG Series
Stainless Steel Vent System| 3" x 5" Concentric Category III Metal Fab
Horizontal Vent Kit
Low profile cone design for
concentric direct vent systems.
Includes 90˚ elbow, short,
low-profile termination and
installation screws.
• RTG20231 - Up to 6" walls
• RTG20234 - Up to 8" walls
Economy Vent Kit
• RTG20210 - Up to 10" walls
Vertical Termination Kit
Concentric direct vent systems.
Stainless steel and galvanized
construction. Includes vertical
termination cap, storm collar,
6-12 pitch roof flashing and
installation screws. Vent pipe
not included.
• RTG 2 0211 - Vertical Vent Kit
Additional venting and accessories
are available. See Catalog for details.
PVC VENT SYSTEM
INDOOR
Horizontal
vent
termination
INDOOR
Ver tic al
vent
termination
3"/5" CONCENTRIC
VENT SYSTEM
INDOOR
Horizontal
vent
termination
INDOOR
Ver tic al
vent
termination
Stainless Steel Metal Fab Venting Components and Accessories
90˚ Elbow
8.1" rise – 8.1" run
• RTG20151A-1
14 PRODUCT GUIDE | TANKLESS GAS WATER HEATERS
45˚ Elbow
8.6" rise – 3" run
• RTG20151B-1
6" Vent Length
5.66" overall length
• RTG20151W
24" Vent Length
23.66" overall length
• RTG20151C-1
Wall Hanger
2-point pivot
mounting
• RTG20151H
12" Vent Length
11.66" overall length
• RTG20151R
36" Vent Length
35.66" overall length
• RTG20151D-1
Wall Thimble
17" wide for up to
6" deep walls, with
drywall and stucco
rings, ideal for new
construction
• RTG20151Z
OUTDOOR
OUTDOOR*
Recess box
installation
Venting details, including clearances,
instructions and diagrams can be
found in the “Use & Care Manual” of
Rheem indoor tankless water heaters.
(ULCS636 Pipe must be used for
Canada.)
* Outdoor units do not require venting materials.
OUTDOOR*
installation
Page 15
Rheem® Commercial Tankless Common Venting
Header kits include all required venting pieces to connect multiple units. Additional vent run accessories are required to complete
installation. Common venting header kits are available for inline or back to back installations, direct vent or room air intake
options, using 6”, 8” and 10” trunk diameters.
Don’t let limited cash-on-hand keep you
from being comfortable.
The Rheem KwikComfort® Financing program makes it easy to
find a financing option that works for you! With many options and
benefits available, KwikComfort
the home comfort you need without the wait.
®
Financing is the best way to get
PROTECH® Service & Parts Kit
These kits, designed with the contractor in mind, provide all
the basic parts necessary for a complete repair of a Rheem
tankless gas water heater.
• PROTECH PD966349
Mid-Efficiency Direct Vent Models
• PROTECH PD966350
Mid-Efficiency Outdoor Models
• PROTECH PD966351
Condensing Models
CONTACT US