Rheem RTG-53PV, RTG-53X, RTG-53DV User Manual

RHEEM RESIDENTIAL TANKLESS
42†& 53 TANKLESS SERIES
Endless hot water for 1-2 bathroom homes
RTG2-42PV†indoor natural and LP models – 21,500 - 118,000 BTU max.
5.5 gal./min at 35° F rise max., 4.2 gal./min. at 45° F rise
Limited Warranty:
10-Year on heat exchanger, 3-Year on parts
See Residential Warranty Information Brochure for complete warranty information.
RTG-53PV indoor and RTG-53DV indoor direct vent natural and LP models – 20,000 - 145,000 BTU max.*
6.8 gal./min at 35° F rise max., 5.3 gal./min. at 45° F rise
RTG-53X outdoor natural and LP models – 19,000 - 141,000 BTU max.*
6.8 gal./min at 35° F rise max., 5.3 gal./min. at 45° F rise
Limited Warranty:
12-Year on heat exchanger, 5-Year on parts, 1-Year on labor
See Residential Warranty Information Brochure for complete warranty information.
145,000 BTU INDOOR DIRECT VENT
UMC-117 remote control is included and can be set from the out-of-the-box 120
degrees – up to a 140 degree maximum (additional remote control thermostats are
available – sold separately)
EZ-Link™cable available for high demand applications to connect two tankless
units to operate as one Exclusive! Guardian SBT™sensing burner technology
Exclusive! Guardian OFW™overheat film wrap
Exclusive! Two high-altitude options – up to 6,560 or 9,840 ft.** elevations
above sea level Exclusive! All Rheem models can be linked in up to 20 unit manifold installations
by using the optional MIC-180 and MICS-180 manifold control assembly All Rheem tankless models are third-party efficiency certified by GAMA
Continuous hot water, energy saving and compact, space saving design
Indoor units use Category III stainless steel vents and vent horizontally
or vertically Indoor models supplied with a 120 volt power cord
Environmentally friendly Low NOx burner meets SCAQMD rule 1146
requirements Installation vent kits available – sold separately
Indoor and outdoor models feature freeze protection to -20°F
* BTU varies by model and field type. See specifications for details.
** Not available on all models.
† Limited availability in Canada.
(altitude chip required – sold separately)
Tankless water heaters
141,000 BTU OUTDOOR
118,000 & 145,000 BTU INDOOR
Endless hot water
See reverse for specifications.
42 & 53 TANKLESS SERIES
Water Heater Flow Rate Curves
0
1
2
3
4
5
6
7
10 15 20 25 30 35 40 45 50 55 60 70 80 90 100
Delta-T
GPM
53 Max Flow
42 Max Flow
®
Specifications
D
ESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
M
ODEL INPUT TEMP.
NUMBER BTU/HR. TYPE RANGE
R
HEEM TANKLESS WATER HEATERS FOR 1-2 BATHROOM HOMES
RTG2-42PVN†
RTG-53PVN
RTG-53XN
RTG-53DVN
GAS WATER FLOW RATE VENT SHIP. D.O.E. ANN.
21,500 ­118,000 140° F
21,500 ­145,000 140° F
19,000 ­141,000 140° F
20,000 ­141,000
Indoor
Indoor
Outdoor
Indoor
DirectVent
G
PM @ 77° GPM @ 45° GPM @ 35°
RISE MAX. RISE MAX. RISE MAX. WATER GAS
100° to
100° to
100° to
100° to 140° F
2.5 4.2 5.5 3/4 3/4 20-1/2 13-3/4 6-1/4 3 35 .83 $220/$369
3.1 5.3 6.8 3/4 3/4 20-1/2 13-3/4 6-1/4 3 36 .82 $223/$374
3.0 5.3 6.8 3/4 3/4 20-1/2 13-3/4 6-1/4 N/A 36 .82 $223/$374
3.0 5.3 6.8 3/4 3/4 23 13-3/4 7-1/4
C
ONNECTION DIAMETER WEIGHT ENERGY OP. COST
HEIGHT WIDTH DEPTH (INCHES) (LBS.) FACTOR NAT/LP
3 by 5
CONCENTRIC
39 .82 $223/$374
All models are available in Natural Gas and Propane (LP). For Propane replace the N with P when ordering.
135,000 for Propane model.
*
• Factory set maximum temperature is 120° F. See Use and Care Manual for setting.
• For installations above 3,280 feet, a high altitude chip is required. Refer to Rheem price list or consult factory for details.
Consult factory for information on sizing the application.
Installation Vent Kits available separately: 3" diameter for RTG2-42PV† and RTG-53PV models. Vent Termination Kits are required for Direct Vent models. Contact your distributor for details.
Proper gas pressure must be ensured to supply tankless gas water heaters – up to 118,000 BTU for RTG2-42† models, and up to 145,000 BTU for RTG-53 models. (Consult your gas supplier)
Temperature Rise (°F)
Model Number 35°
45° 50° 60° 70° 77° 80° 90° 100° RTG2-42† Water Flow (GPM) 5.5 4.2 3.8 3.2 2.7 2.5 2.4 2.1 1.9 RTG-53 Water Flow (GPM) 6.8 5.3 4.7 3.9 3.4 3.1 3.0 2.6 2.4
Above estimates are for sizing purposes only.
Energy Factor and Average Annual Operating Costs based on D.O.E. (Department of Energy) test procedures. D.O.E. national average fuel rate natural gas $1.218/therm; LP $1.87/gallon
.
† Limited availability in Canada.
These units are designed to meet or exceed ANSI (American National Standards Institute) requirements and have been tested according to D.O.E. test procedures and meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria for energy consuming appliances.
Before purchasing this appliance, read important energy cost and efficiency information available from your supplier.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Heating, Cooling & Water Heating 101 Bell Road • Montgomery, AL 36117-4305 1-866-720-2076 • www.rheemtankless.com
Rheem Canada Ltd./Ltée • Water Heater Division 128 Barton Street West, Hamilton, Ontario L8N 3P3
Rheem manufactures residential & commercial heating, cooling & water heating products.
Printed in U.S.A. 07/08 WP Form No. 101-50-53CAN
Loading...