Rheem RPNE-036CAZ, RPNE-018JAZ, RPNE-024JAZ, RPNE-030JAZ, RPNE-036DAZ Instructions Manual

...
FORM NO. P11-766 REV. 7
Supersedes Form No. P11-766 Rev. 6
RPNE- SERIES
Seven Models
13 SEER with efficiencies ranging up to 14 SEER in certain matched systems. Nominal Sizes 1
/2
to 5 Tons
[5.28 kW] to [17.58 kW]
The Rheem Classic®Series RPNE- Heat Pump Outdoor units can provide year-round heating and cooling comfort for residential, multi-family and light commercial applica­tions. They are designed to operate with Rheem indoor units with cooling and heating capacities certified under the ARI Certification program.
The Rheem RHSA-, RHLA- & RHKA- Air Handlers are equipped with auxiliary heating elements for supplementary heat was designed especially for use with the RPNE- Heat Pump. Together they provide systems capable of delivering a maximum HSPF (Heating Seasonal Performance Factor) of 9.10 in the heating mode or a maximum standard S.E.E.R. (Seasonal Energy Efficiency Ratio) of 14.00 in the cooling mode.
The following additional features, plus its energy-saving characteristics, make the RPNE- Heat Pump outdoor unit an excellent choice for new construction or upgrading your present system.
Attractive, louvered wrap around jacket protects coil from
weather extremes and yard hazards. Top grille is steel reinforced for extra strength. Cabinet is powder painted for all weather protection.
Four sided outdoor coil design allows compressor opera-
tion with access panel removed.
Air is discharged upward away from bushes and shrubs.
The discharge pattern of the top grille provides minimum air restriction, resulting in quiet fan operation.
Combination Grille/Motor Mount secures the fan motor to
the underside of the discharge grille.
All controls are accessible by removing one service
panel. Removable top grille provides access to the out­door fan motor and outdoor coil.
Compressor compartment offers additional protection
from the elements and reduces operating noise.
Single speed, 8-pole fan motor is designed for quieter,
energy-saving operation.
Non-cycling reversing valve and demand defrost.
All models meet or exceed a 1000-hour salt spray test per
ASTM B117 Standard Practice for Operating Salt Spray Testing Apparatus.
HEAT PUMPS
(IN CERTAIN
MATCHED SYSTEMS)
13.0
2 Rheem Heating, Cooling and Water Heating
Engineering Features
RPNE- Series Heat Pump Outdoor Unit
1. Scroll compressor is hermetically sealed and incorporates internal high temperature motor overload protection, and durable insulation on the motor windings. It is externally mounted on rubber grommets to reduce vibration and noise.
2. Copper Tube/Aluminum Fin Coils—Both indoor and outdoor coils.
3. Strong, Attractive Cabinet—Constructed of powder painted steel.
Louvered design protects the coil from damage.
4. Internal Check Valve—Provides for more quiet refrigerant metering.
5. Enhanced Compressor Protection—Features an enhanced defrost control, auto-reset high pressure control, and auto-reset low pressure control to provide compressor protection under abnormally
high head pressure conditions (outdoor fan failure, restriction, dirty coil, etc.) or abnormally low suction pressure conditions (restrictions, TXV failure, loss of charge, indoor blower failure, etc.) while eliminating nuisance tripping sometimes experienced with conventional control systems.
6. Drawn Painted Base Pan—For extra corrosion resistance and sound reduction.
7. Demand Defrost Control—Provides complete defrost when defrost is required.
8. Non-Cycling Reversing Valve—Eliminates discharge noises on each heating cycle.
9. Hot Gas Muffler—Reduces noise in heating cycle.
10. Bi-Directional Filter Drier—Standard on all models.
11. Service valves are standard on all models.
12. Refrigerant Metering—TX valves accurately meter refrigerant into
indoor and outdoor coils.
13. The RPNE has a 10 year limited compressor warranty.
14. All refrigerant connections are on the exterior of the unit, located close
to the ground for neat appearing installations.
15. Coil design permits compressor operation with the access panel removed.
16. Control box is fully accessible in the upper part of the cabinet, just under the access panel.
17. Power and control wiring are kept separate.
18. Every unit is factory charged and tested.
All controls and compressor are accessible
for servicing by removal of the service panel.
Drawn Painted Base Pan.
Model Number Identification
[ ] Designates Metric Conversions
R P N E 018
RHEEM REMOTE
HEAT PUMP
HIGH
EFFICIENCY
(STANDARD)
DESIGN SERIES
018 = 18,000 BTU/HR [5.28 kW] 024 = 24,000 BTU/HR [7.03 kW] 030 = 30,000 BTU/HR [8.79 kW] 036 = 36,000 BTU/HR [10.55 kW] 042 = 42,000 BTU/HR [12.31 kW] 048 = 48,000 BTU/HR [14.07 kW] 060 = 60,000 BTU/HR [17.58 kW]
COOLING
CAPACITY
J A Z
ELECTRICAL
DESIGNATION
J = 208/230V-1-60 C = 208/230V-3-60 D = 460V-3-60 Y = 575V-3-60
(4&5 TON ONLY)
VARIATIONS
A-SERIES = FULL-FEATURED
COOLING
CONNECTION
FITTING
Z = SWEAT W/SCROLL
Rheem Heating, Cooling and Water Heating 3
Accessories
Low Ambient Control—Allows low temperature operation in the cooling cycle down to 0°F [-17.8°C] outdoor temperature. It is recommended that this control be installed in units to be operated for cooling at outdoor ambient temperatures under 65°F [18°C]. (Model No. RXPZ-C01)
Outdoor Thermostats— RXPT-A01—One outdoor thermostat in box. RXPT-A02—One outdoor thermostat for mounting in box for use with RXPT-A01 or A03. RXPT-A03—One outdoor thermostat with emergency Heat Relay wired and mounted in box. RXPT-A04—Two outdoor thermostats with emergency Heat Relay wired and mounted in box.
Compressor Crankcase Heater—Available through PROSTOCK®.
Heat Pump Monitor—Indicates inefficient operation or malfunction of heat pump. (Model No. RXPM-B01)
Thermostats
Compressor Time Delay Control—Compressor will remain off for five minutes after power or thermostat interruption, allowing system pressures to equalize. Starting during high pressure conditions can result in shortened compressor life. (Model No. RXMD-B01)
Blower Time Delay Control—RXMD-C04—Time Delay Accessory is not required if the outdoor unit is matched with a Rheem furnace or air handler, or if the furnace or air handler used has a blower off time delay built in.
Fossil Fuel Kits—RXPF-01
RXPF-02
Enhanced Compressor Protection Kit (R-22)—RXPG-A01. This kit includes an enhanced defrost control, auto-reset high pressure control (HPC), and auto-reset low pressure control (LPC). This kit provides compressor protection under abnormally high head pressure conditions (outdoor fan failure, restriction, dirty coil, etc.) or abnormally low suction pressure conditions (restriction, TEV failure, loss of charge, indoor blower failure, etc.) while eliminating nuisance tripping sometimes experienced with conventional control systems.
Hard Start Components—Offer additional starting torque to cover a wide range of voltage and pressure variations. Available through PROSTOCK
®
[ ] Designates Metric Conversions
4 Rheem Heating, Cooling and Water Heating
SCROLL®COMPRESSOR
The scroll compressor is the key to efficiency for this Rheem model. It’s the latest in high-efficiency compressor technology. The advanced scroll compressor offers low noise and vibration characteristics and features tolerance to liquid refrigerant and system contamination. The Scroll also has low start torque, eliminating start problems in the field. And its unique design enables the RPNE- heat pump to perform efficiently, quietly and reliably.
For all season home comfort, performance and energy conservation, choose a Rheem RPNE- Series Heat Pump and a RHSA, RHLA, or RHKA Series Air Handler.
More than a reverse cycle air conditioner, it’s a specially designed combination Winter/Summer comfort system using a single indoor coil for heating and cooling.
To choose an Air Handler designed for use with the RPNE- Heat Pump, refer to the Performance Data Tables and/or the air handler specification sheet.
Rheem Heat Pump System
Rheem Heating, Cooling and Water Heating 5
Performance Data ARI Standard Conditions—Single Phase (Scroll Compressor)
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions
ARI Cooling Performance ARI Heating Performance (70°F [21°C] Indoor)
95°F [35°C] DB Outdoor Air
Net
Sens.
BTU/H
[kW]
13,350
[3.9]
13,450
[3.9]
13,550
[4.0]
13,550
[4.0]
13,600
[4.0]
13,750
[4.0]
13,600
[4.0]
13,750
[4.0]
13,600
[4.0]
13,550
[4.0]
13,600
[4.0]
13,450
[3.9]
13,300
[3.9]
13,350
[3.9]
13,350
[3.9]
13,350
[3.9]
13,350
[3.9]
13,350
[3.9]
13,350
[3.9]
13,400
[3.9]
13,300
[3.9]
13,350
[3.9]
13,550
[4.0]
13,350
[3.9]
13,800
[4.0]
13,550
[4.0]
17,200
[5.0]
16,850
[4.9]
16,850
[4.9]
Net Latent BTU/H
[kW]
5,050
[1.5]
5,050
[1.5]
5,150
[1.5]
5,150
[1.5]
5,100
[1.5]
5,250
[1.5]
5,100
[1.5]
5,250
[1.5]
5,200
[1.5]
5,150
[1.5]
5,100
[1.5]
5,050
[1.5]
4,700
[1.4]
4,650
[1.4]
4,650
[1.4]
4,750
[1.4]
4,650
[1.4]
4,750
[1.4]
4,650
[1.4]
4,700
[1.4]
4,700
[1.4]
4,750
[1.4]
5,150
[1.5]
5,050
[1.5]
5,200
[1.5]
5,150
[1.5]
6,400
[1.9]
6,550
[1.9]
6,550
[1.9]
Snd.
SEER
Rate
EER
11.70 13.00 72
11.15 13.00 72
12.30 14.00 72
12.35 14.00 72
12.50 14.00 72
12.60 14.00 72
12.50 14.00
12.60 14.00 72
12.50 14.00 72
12.25 14.00 72
12.45 14.00 72
11.15 13.00 72
12.15 14.00 72
12.20 13.00 72
12.25 13.00 72
12.40 13.00 72
12.30 13.00 72
12.40 13.00 72
12.30 13.00 72
12.40 13.00 72
12.15 13.00 72
12.35 13.00 72
12.35 14.00 72
11.70 13.00 72
12.60 14.00 72
12.35 14.00 72
11.40 13.00 73
11.35 13.00 73
11.35 13.00 73
Indoor
CFM
dB
[L/s]
650
[307]
650
[307]
600
[283]
600
[283]
600
[283]
625
[295]
600
72
[283]
625
[295]
600
[283]
600
[283]
600
[283]
650
[307]
600
[283]
600
[283]
600
[283]
600
[283]
625
[295]
600
[283]
625
[295]
600
[283]
600
[283]
600
[283]
600
[283]
650
[307]
650
[307]
600
[283]
825
[389]
700
[330]
700
[330]
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
BTU/H
17,300
17,400
16,900
16,900
16,900
16,900
16,900
16,900
16,900
17,000
16,900
17,400
17,000
17,000
17,000
17,000
17,000
17,000
17,000
17,000
17,000
17,000
16,900
17,300
16,900
16,900
23,000
22,600
22,600
[kW]
[5.1]
[5.1]
[5.0]
[5.0]
[5.0]
[5.0]
[5.0]
[5.0]
[5.0]
[5.0]
[5.0]
[5.1]
[5.0]
[5.0]
[5.0]
[5.0]
[5.0]
[5.0]
[5.0]
[5.0]
[5.0]
[5.0]
[5.0]
[5.1]
[5.0]
[5.0]
[6.7]
[6.6]
[6.6]
COP
3.24
3.34
3.60
3.60
3.64
3.62
3.62
3.62
3.64
3.58
3.62
3.34
3.90
3.92
3.92
3.92
3.92
3.92
3.92
3.92
3.92
3.92
3.62
3.24
3.62
3.62
3.54
3.36
3.36
Outdoor Air 17°F [–8.5°C] DB/ 15°F [–9.5°C] WB
DOE Low Temp.
BTU/H
[kW]
11,000
[3.2]
11,100
[3.3]
10,600
[3.1]
10,600
[3.1]
10,600
[3.1]
10,600
[3.1]
10,600
[3.1]
10,600
[3.1]
10,600
[3.1]
10,600
[3.1]
10,600
[3.1]
11,100
[3.3]
10,200
[3.0]
10,200
[3.0]
10,200
[3.0]
10,200
[3.0]
10,200
[3.0]
10,200
[3.0]
10,200
[3.0]
10,200
[3.0]
10,200
[3.0]
10,200
[3.0]
10,600
[3.1]
11,000
[3.2]
10,600
[3.1]
10,600
[3.1]
14,400
[4.2]
14,400
[4.2]
14,400
[4.2]
DOE
Region
IV
HSPF
COP
2.46 8.50
2.42 8.35
2.60 8.90
2.60 9.00
2.62 9.00
2.62 9.00
2.62 9.00
2.62 9.00
2.62 9.00
2.58 8.90
2.62 9.00
2.42 8.35
2.60 8.20
2.58 8.20
2.58 8.20
2.58 8.20
2.58 8.20
2.58 8.20
2.58 8.20
2.58 8.20
2.58 8.20
2.58 8.20
2.62 9.00
2.46 8.50
2.62 9.00
2.62 9.00
2.40 8.50
2.30 8.30
2.30 8.30
Outdoor
Unit
RPNE-
Model Numbers
Indoor Coil and/or Air Handler
Capacity
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
Tot al
BTU/H
[kW]
Rev. 3/25/2008
18,400
[5.4]
18,500
[5.4]
18,700
[5.5]
18,700
[5.5]
18,700
[5.5]
19,000
[5.6]
18,700
[5.5]
19,000
[5.6]
18,800
[5.5]
18,700
[5.5]
18,700
[5.5]
18,500
[5.4]
18,000
[5.3]
18,000
[5.3]
18,000
[5.3]
18,100
[5.3]
18,000
[5.3]
18,100
[5.3]
18,000
[5.3]
18,100
[5.3]
18,000
[5.3]
18,100
[5.3]
18,700
[5.5]
18,400
[5.4]
19,000
[5.6]
18,700
[5.5]
23,600
[6.9]
23,400
[6.9]
23,400
[6.9]
018JAZ
024JAZ
RHSA-HM1817 (RCSA-H*2417A*)
RCFA-H*2414A*+RXMD-C04
RCFA-H*2417A* (RGFD-06?MCK?)
RCFA-H*2417A* (RGFD-07?MCK?)
RCFA-H*2417A* (RGGD-06?MCK?)
RCFA-H*2417A* (RGGD-07?MCK?)
RCFA-H*2417A* (RGJD-06?MCK?)
RCFA-H*2417A* (RGJD-07?MCK?)
RCFA-H*2417A* (RGLR-07?AMK?)
RCFA-H*2417A* (RGPR-05?BMK?)
RCFA-H*2417A* (RGPR-07?AMK?)
RCFA-H*2417A*+RXMD-C04
RBHP-17 (RCHJ-24A1)
RCHJ-24A1 (RGFD-06?MCK?)
RCHJ-24A1 (RGFD-07?MCK?)
RCHJ-24A1 (RGGD-06?MCK?)
RCHJ-24A1 (RGGD-07?MCK?)
RCHJ-24A1 (RGJD-06?MCK?)
RCHJ-24A1 (RGJD-07?MCK?)
RCHJ-24A1 (RGLR-07?AMK?)
RCHJ-24A1 (RGPR-05?BMK?)
RCHJ-24A1 (RGPR-07?AMK?)
17AHLA24HM (RCSA-H*2417A*)
17AHSA18HM (RCSA-H*2417A*)
RHKA-HM2417 (RCSA-H*2417A*)
RHLA-HM2417 (RCSA-H*2417A*)
RHSA-HM2417 (RCSA-H*2417A*)
RCFA-H*2414A*
RCFA-H*2417A*
Loading...
+ 11 hidden pages