Rheem RP14 Submittal Sheet

SUBMITTAL COVER SHEET
Quantity
Unit Designation
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES: NOTES:
PRINTED IN U.S.A 01/12 QG FORM NO. M11-1640
PROJECT NAME
LOCATION
ARCHITECT
ENGINEER
CONTRACTOR
SUBMITTED BY DATE
UNIT SUMMARY
UNIT DATA
COOLING PERFORMANCE
EFFICIENCY ..................................
_______
SEER
TOTAL CAPACITY*....................
_______
MBH [kW]
SENSIBLE CAPACITY*..............
_______
MBH [kW]
OUTDOOR DESIGN TEMP. ........
_______
°F [°C] DB
TEMP. OF AIR ENTERING
EVAPORATOR COIL ..............
_______
°F [°C] DB
_______
°F [°C] WB
POWER INPUT REQUIREMENT ..........
_______
kW
(*uses blower motor heat)
HEATING PERFORMANCE
EFFICIENCY ..................................
_______
HSPF
TOTAL CAPACITY*....................
_______
MBH [kW]
OUTDOOR DESIGN TEMP. ........
_______
°F [°C] DB
TEMP. OF AIR ENTERING
EVAPORATOR COIL ..............
_______
°F [°C] DB
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ..................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT........................................
_______
IWG
BLOWER SPEED..............................
_______
RPM
POWER OUTPUT REQUIREMENT ....
_______
BHP
MOTOR RATING ..........................
_______
HP [W]
POWER INPUT REQUIREMENT ..........
_______
kW
ELECTRICAL DATA
POWER SUPPLY..........................
____________ Hz
TOTAL UNIT AMPACITY..................
_______
AMPS
MINIMUM WIRE SIZE ......................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ............
_______
AMPS
CLEARANCES
ACCESS SIDE 24" [609.6 mm]
AIR INLETS 12" [304.8 mm]
ABOVE UNIT 60" [1524 mm]
JOB NAME LOCATION
CONTRACTOR ORDER NO.
ENGINEER UNIT MODEL NO.
SUBMITTED FOR APPROVAL RECORD COIL MODEL NO.
DATE AIR HANDLER MODEL NO.
SUBMITTAL SHEET FOR RP14 SERIES 1
1
/2 TO 5 NOMINAL TON [5.28 TO 17.6 kW], 14 SEER
HEAT PUMP UNITS
FORM NO. X33-1552
FEATURES FOR RP14 SERIES HEAT PUMP UNITS
• New composite base pan – dampens sound, captures louver panels, eliminates corrosion and reduces number of fasteners needed
• Improved tubing design – reduces vibration and stress, making unit quieter and reducing opportunity for leaks
• Optimized defrost characteristics – decrease defrosting and provide better home comfort
• Powder coat paint system – for a long lasting professional finish
• Optimized reversing valve sizing – improves shifting performance for quieter unit operation and increased life of the system
• Enhanced mufflers – help to dissipate vibration energy for quieter unit operation
• Scroll compressor – a sound abating feature added to the compressor significantly reduces noise when system transitions in and out of defrost mode
• Modern cabinet aesthetics – increased curb appeal with visually appealing design
• Curved louver panels – provide ultimate coil protection, enhance cabinet strength, and increased cabinet rigidity
• Optimized fan orifice – optimizes airflow and reduces unit sound
• Rust resistant screws – confirmed through 1500-hour salt spray testing
• PlusOne™ Expanded Valve Space – 3"-4"-5" service valve space – provides a minimum working area of 27-square inches for easier access
• Integrated heat pump lift receptacle – allows standard CPVC stands to be inserted into the base
• PlusOne™ Triple Service Access – 15" wide, industry leading corner service access – makes repairs easier and faster. The two fastener removable corner allows optimal access to internal unit components. Individual louver panels come out once fastener is removed, for faster coil cleaning and easier cabinet reassembly
• Diagnostic service window with two-fastener opening – provides access to the TXV valves and the heat pump reversing valve before opening the unit.
• External gauge port access – allows easy connection of “low-loss” gauge ports
• Single-row condenser coil – makes unit lighter and allows thorough coil cleaning to maintain “out of the box” performance
• 35% fewer cabinet fasteners and fastener-free base – allow for faster access to internal components and hassle-free panel removal
• Service trays – hold fasteners or caps during service calls
• QR code – provides technical information on demand for faster service calls
• Fan motor harness with extra-long wires – allows unit top to be removed without discon­necting fan wire
ACCESSORIES/OPTIONS
Compressor Crankcase Heater ....................................................................................
Low Ambient Control (Model No. RXAD-A08)........................................................................
Compressor Sound Cover......................................................................................................
Compressor Hard Start Kit ....................................................................................................
Classic Top Cap w/label (91-101123-21) ..............................................................................