Rheem RP14 Specification

Page 1
Rheem Classic®Series Heat Pump
FORM NO. P11-806 REV. 2
RP14 Series
Efficiencies: 14 SEER/11.5 EER 8.2 HSPF Nominal Sizes 1
1
/2 to 5 Ton [5.28 to 17.6 kW] Cooling Capacities 17.3 to 60.5 kBTU [5.7 to 17.7 kW]
• New composite base pan – dampens sound, captures louver panels, eliminates corrosion and reduces number of fasteners needed
• Improved tubing design – reduces vibration and stress, mak­ing unit quieter and reducing opportunity for leaks
• Optimized defrost characteristics - decrease defrosting and provide better home comfort
• Powder coat paint system – for a long lasting professional finish
• Optimized reversing valve sizing – improves shifting perfor­mance for quieter unit operation and increased life of the system
• Enhanced mufflers – help to dissipate vibration energy for quieter unit operation
• Scroll compressor – a sound abating feature added to the compressor significantly reduces noise when system transi­tions in and out of defrost mode
• Modern cabinet aesthetics – increased curb appeal with visu­ally appealing design
• Curved louver panels – provide ultimate coil protection, enhance cabinet strength, and increased cabinet rigidity
• Optimized fan orifice – optimizes airflow and reduces unit sound
• Rust resistant screws – confirmed through 1500-hour salt spray testing
• PlusOne™ Expanded Valve Space – 3"-4"-5" service valve space – provides a minimum working area of 27-square inches for easier access
• Integrated heat pump lift receptacle – allows standard CPVC stands to be inserted into the base
• PlusOne™ Triple Service Access – 15" wide, industry lead- ing corner service access – makes repairs easier and faster. The two fastener removable corner allows optimal access to internal unit components. Individual louver panels come out once fastener is removed, for faster coil cleaning and easier cabinet reassembly
• Diagnostic service window with two-fastener opening – provides access to the TXV valves and the heat pump revers­ing valve before opening the unit.
• External gauge port access – allows easy connection of “low-loss” gauge ports
• Single-row condenser coil – makes unit lighter and allows thor­ough coil cleaning to maintain “out of the box” performance
• 35% fewer cabinet fasteners and fastener-free base – allow for faster access to internal components and hassle-free panel removal
• Service trays – hold fasteners or caps during service calls
• QR code – provides technical information on demand for faster service calls
• Fan motor harness with extra-long wires – allows unit top to be removed without disconnecting fan wire
Air
Heat Pumps
RP14 Series
“Proper sizing and installation of equipment is critical to achieve
optimal performance. Ask your Dealer for details or visit www.energystar.gov.”
16.0
Page 2
Air
Table of Contents
RP14 Series
2
TABLE OF CONTENTS
Standard Feature Table ............................................................................................3
Available SKUs ........................................................................................................3
Features & Benefits ..............................................................................................4-5
Model Number Identification ................................................................................6-7
Physical Data ............................................................................................................8
Electrical Data ..........................................................................................................8
Accessories ..............................................................................................................9
Weighted Sound Power............................................................................................9
Thermostats..............................................................................................................9
Unit Dimensions......................................................................................................10
Clearances..............................................................................................................11
Wiring Diagrams ....................................................................................................12
Application Guidelines ............................................................................................12
Refrigerant Line Size Information ......................................................................13-14
Performance Data ............................................................................................15-18
Guide Specifications ..............................................................................................19
Limited Warranty ....................................................................................................20
Page 3
Air
Standard Feature Table/Available SKUs
RP14 Series
3
Feature 18 24 30 36 42 48 60
R-410a Refrigerant Maximum SEER 14 14 14 14 14 14 14 Maximum EER 11.5 11.5 11.5 11.5 11.5 11.5 11.5 Scroll Compressor Field Installed Filter Drier Front Seating Service Valves High Pressure Switch Low Pressure Switch Internal Pressure Relief Valve Internal Thermal Overload Long Line capability Low Ambient capability with Kit 3-4-5 Service Valve Access Composite Basepan 2 Screw Control Box Access 15" Access to Internal Components Quick release louver panel design No fasteners to remove along bottom Optimized Venturi Airflow Single row condenser coil Powder coated paint Rust resistant screws QR code External gauge ports Service trays
= Standard
Standard Feature Table
Available SKU
Available Models Description
RP1418AJ1NA
Classic
®
1 1/2 ton 14 SEER Single-Stage Heat Pump-208/230/1/60
RP1424AJ1NA
Classic
®
2 ton 14 SEER Single-Stage Heat Pump-208/230/1/60
RP1430AJ1NA
Classic
®
2 1/2 ton 14 SEER Single-Stage Heat Pump-208/230/1/60
RP1436AJ1NA
Classic
®
3 ton 14 SEER Single-Stage Heat Pump-208/230/1/60
RP1442AJ1NA
Classic
®
3 1/2 ton 14 SEER Single-Stage Heat Pump-208/230/1/60
RP1448AJ1NA
Classic
®
4 ton 14 SEER Single-Stage Heat Pump-208/230/1/60
RP1460AJ1NA
Classic
®
5 ton 14 SEER Single-Stage Heat Pump-208/230/1/60
RP1436AC1NA
Classic
®
3 ton 14 SEER Single-Stage Heat Pump-208/230/3/60
RP1442AC1NA
Classic
®
3 1/2 ton 14 SEER Single-Stage Heat Pump-208/230/3/60
RP1448AC1NA
Classic
®
4 ton 14 SEER Single-Stage Heat Pump-208/230/3/60
RP1460AC1NA
Classic
®
5 ton 14 SEER Single-Stage Heat Pump-208/230/3/60
RP1436AD1NA
Classic
®
3 ton 14 SEER Single-Stage Heat Pump-460/3/60
RP1442AD1NA
Classic
®
3 1/2 ton 14 SEER Single-Stage Heat Pump-460/3/60
RP1448AD1NA
Classic
®
4 ton 14 SEER Single-Stage Heat Pump-460/3/60
RP1460AD1NA
Classic
®
5 ton 14 SEER Single-Stage Heat Pump-460/3/60
Page 4
Air
Features & Benefits
RP14 Series
4
The RP14 is our 14 SEER heat pump and is part of the Rheem heat pump product line that extends from 14 to 20 SEER. This highly featured and reliable heat pump is designed for years of reliable, efficient operation when matched with Rheem indoor aluminum evaporator coils and furnaces or air handler units with aluminum evaporators.
Our unique composite base ( ) reduces sound emission, elimi­nates rattles, significantly reduces fasteners, eliminates corrosion and has integrated brass compressor attachment inserts
()
. Furthermore it has incorporated into the design, water manage­ment features, means for hand placement
()
for unit maneu-
vering, screw trays ( ) and inserts for lifting unit off pad. ( )
Service Valves ( ) are rigidly mounted in the composite base with 3" between suction and discharge valves, 4" clearance below service valves and a minimum of 5" above the service valves, creating industry leading installation ease. The minimum 27-square inches around the service valves allows ample room to remove service valve schrader prior to brazing, plenty of clearance for easy brazing of the suction and discharge lines to service valve outlets, easy access and hookup of low loss refrig­erant gauges ( ), and access to the service valve caps for opening. For applications with long-line lengths up to 250 feet total equivalent length, up to 200 feet heat pump above evapo­rator, or up to 80 feet evaporator above heat pump, the long-line instructions in the installation manual should be followed.
Controls are accessed from the corner of the unit by removing only two fasteners from the control access cover, revealing the industry’s largest 15" wide and 14" tall control area
()
. With all this room in the control area the high voltage electrical whip ( ) can easily be inserted through the right size opening in the bot­tom of the control area. Routing it leads directly to contractor lugs for connection. The low voltage control wires
()
are easily connected to units low voltage wiring. If contactor defrost con­trol or capacitor ( ) needs to be replaced there is more than adequate space to make the repair. Furthermore, the service window ( ) can be removed to access the TXV and reversing valve by removing two screws or the entire corner can be removed providing ultimate access to the TXV or reversing valve.
()
If in the rare event, greater access is needed to internal compo­nents, such as the compressor, the entire corner of the unit can be removed along with the top cover assembly to have unprece­dented access to interior of the unit
()
. Extra wire length is incorporated into each outdoor fan and compressor so top cover and control panel can be positioned next to unit. With minimal effort the plug can be removed from the compressor and the outdoor fan wires can be removed from the capacitor to allow even more uncluttered access to the interior of the unit
()
. Outdoor coils heights range from as short as 22" to 32", aiding access to the compressor. Disassembly to this degree and com­plete reassembly only takes a first time service technician less than 10 minutes.
()
All units utilize strong formed louver panels which provide indus­try leading coil protection. Louver removal for coil cleaning is accomplished by removing one screw and lifting the panel out of the composite base pan
().
All RP14 units utilize single row coils ( ) making cleaning easy and complete, restoring the performance of the heat pump back to out of the box perfor­mance levels year after year.
The outdoor fan motor has sleeve bearings and is inherently protected. The motor is totally enclosed for maximum protection from weather, dust and corrosion. Access to the outdoor fan is made by removing four fasteners from the fan grille. The outdoor fan can be removed from the fan grille by removing 4 fasteners in the rare case outdoor fan motor fails.
Each cabinet has optimized composite ( ) fan orifice assuring efficient and quiet airflow.
1
2
3
4
7
8
9
10
12
13
14
15
5
6
11
18
17
16
19
Introduction to RP14 Heat Pump
1
4
6
4
3 5
2
8
11
9
10
13
12
16
14
18
15
19
7
17
Page 5
Air
Features & Benefits
RP14 Series
5
The entire cabinet has powder post paint ( ) achieving 1000 hour salt spray rating, allowing the cabinet to retain its aesthetics throughout its life.
Scroll compressors with standard internal pressure relief and internal thermal overload are used on all capacities assuring longevity of high efficient and quiet operation for the life of the product. All RP14 Heat Pumps come standard with high and low pressure switches.
Each unit is shipped with filter drier for field installation and will trap any moisture or dirt that could contaminate the refrigerant system.
All cabinets have industry leading structural strength due to the composite base pan
()
, interlocking corner post
()
, formed
curved louver panels
()
and drawn top cover
()
making it
the most durable cabinet on the market today.
Each RP14 capacity has undergone rigorous psychrometric testing to assure performance ratings of capacity, SEER, EER and HSPF per AHRI Standard 210/240 rating conditions. Also each unit bears the UL mark and each unit is certified to UL 1995 safety standards.
Each unit has undergone specific strain and modal testing to assure tubing
()
is outside the units natural frequency and that the suction and discharge lines connected to the compressor with stand any starting, steady state operation or shut down forces imposed by the compressor.
All units have been sound tested in sound chamber to AHRI 270 rating conditions, and A-weighted Sound Power Level tables produced, assuring units have acceptable noise qualities (see page 8). Each unit has been ran in cooling operation at 95°F and 47°F and sound ratings for the RP14 range from as low as 74 dBA to 77 dBA.
All units have been ship tested to assure units meet stringent “over the road” shipping conditions.
As manufactured all units in the RP14 family have cooling capa­bility to 55 °F. Addition of low ambient control will allow the unit to operate down to 0°F.
Factory testing is performed on each unit. All component parts meet well defined specification and continually go through receiving inspections. Each component installed on a unit is scanned, assuring correct component utilization for a given unit capacity and voltage. All condenser coils are leak tested with pressurization test to 550#’s and once installed and assembled, each units’ complete refrigerant system is helium leak tested. All units are fully charged from the factory for up to 15 feet of pip­ing. All units are factory run tested. The RP14 has a 10-year conditional compressor and parts warranty (registration required).
Optional Accessories (Refer to accessory chart for model #)
Compressor Crankcase Heater
• Protects against refrigerant migration that can occur during low ambient operation
Compressor Sound Cover
• Reinforced vinyl compressor cover containing a 1½ inch thick batt of fiberglass insulation
• Open edges are sealed with a one-inch wide hook and loop fastening tape
Compressor hard Start Kit
• Single-phase units are equipped with a PSC compressor motor. This type of motor normally does not need a potential relay and start capacitor
• In conditions such as low voltage, this kit may be required to increase the compressor starting torque
Low Ambient Kit
• Heat Pump operate satisfactorily in the cooling mode down to 55°F outdoor air temperature without any additional controls
• Kit can be added in the field enabling unit to operate properly down to 0° in the cooling mode
• Crankcase heater and freezestat should be installed on com­pressors equipped with a low ambient kit
3"/6"/12"
• Gray high density polyethylene feet are available to raise unit off of mounting surface away from moisture
21 22
23 24
25
20
20
24
23
22
21
25
Page 6
Air
Model Number Identification
RP14 Series
6
R
P 14 24 A
J
1 N A *
Brand Product
Category
SEER Capacity
BTU/HR
Major Series* Voltage Type Controls Minor
Series**
Option
Code
Rheem
P - Heat Pump 13 - 13 SEER
14 - 14 SEER
16 - 16 SEER
17 - 17 SEER
20 - 20 SEER
18 - 18,000 [5.28 kW]
24 - 24,000 [7.03 kW]
30 - 30,000 [8.79 kW]
36 - 36,000 [10.55 kW]
42 - 42,000 [12.31 kW]
48 - 48,000 [14.07 kW]
60 - 60,000 [17.58 kW]
A - 1st Design
J - 1ph, 208-230/60
C - 3ph, 208-230/60
D - 3ph, 460/60
1 - Single-stage
V - Inverter
P - Piston
C - Communicating
N - Non-communicating
A - 1st Design N/A
R
C F 24 17
S
T A M C A *
Brand Product
Category
Type Capacity
BTU/HR
Width Efficiency Metering
Device
Major Series* Orientation Casing Minor Series** Option
Code
Rheem
C - Evap Coil F - Furn Coil
H - Air-Handler Coil
24 - 24,000 [7.03 kW]
36 - 36,000 [10.55 kW]
48 - 48,000 [14.07 kW]
60 - 60,000 [17.58 kW]
14 - 14"
17 - 17.5"
21 - 21"
24 - 24.5"
S- Standard Eff.
M- Mid Eff.
H- High Eff.
T-TXV
E-EEV
P-Piston
A -1st Design M - Multi-poise C - Cased
U - Uncased
A - 1st Design N/A
Heat Pumps
R
A 14 24 A
J
1 N A *
Brand Product
Category
SEER Capacity
BTU/HR [kW]
Major Series* Voltage Type Controls Minor Series** Option Code
Rheem A - Air Conditioners
13 - 13 SEER
14 - 14 SEER
16 - 16 SEER
17 - 17 SEER
20 - 20 SEER
18 - 18,000 [5.28 kW]
24 - 24,000 [7.03 kW]
30 - 30,000 [8.79 kW]
36 - 36,000 [10.55 kW]
42 - 42,000 [12.31 kW]
48 - 48,000 [14.07 kW]
60 - 60,000 [17.58 kW]
A - 1st Design
J - 1ph, 208-230/60
C - 3ph, 208-230/60
D - 3ph, 460/60
1 - Single-stage
2 - Two-stage
V - Inverter
C - Communicating
N - Non-communicating
A - 1st Design N/A
Furnace Coils (For Reference)
Air Conditioners (For Reference)
[ ] Designates Metric Conversions
Page 7
R
96 V A
70
2 3 17 M S A
Brand Series Motor Major Rev Input
BTU/HR [kW]
Stages Air Flow Cabinet
Width
Configuration Nox Minor Rev
Rheem
90 - 90 AFUE
92 - 92 AFUE
95 - 95 AFUE
96 - 96 AFUE
97 - 97 AFUE
V - Variable
speed
T - Constant
Torque
(X-13)
P - PSC
A - 1st Design
040 - 42,000 [12.31 kW]
060 - 56,000 [16.41 kW]
070 - 70,000 [20.51 kW]
085 - 84,000 [24.62 kW]
100 - 98,000 [28.72 kW]
115 - 112,000 [32.82 kW]
1 - Single-stage
2 - Two-stage
M- Modulating
3 - up to 3 ton
5 - 3 1/2 up to 5 ton
14 - 14"
17 - 17.5"
21 - 21"
24 - 24.5"
M - Multi-poise X - Low Nox
S - Standard
A - 1st Design
R
80 2 V A
075
3 17 M S A
Brand Series Stages Motor Major Rev Input
BTU/HR [kW]
Air Flow Cabinet
Width
Configuration Nox Minor Rev
Rheem
80 - 80+ AFUE 1 - Single-stage
2 - Two-stage
V - Variable speed
T - Constant Torque (X-13)
P - PSC premium
S - PSC standard
A - 1st Design
050 - 50,000 [15 kW]
075 - 75,000 [22 kW]
100 - 100,000 [29 kW]
125 - 125,000 [37 kW]
150 - 150,000 [44 kW]
3 - up to 3 ton
4 - 2 1/2 to 4 ton
5 - 3 1/2 up to 5 ton
14 - 14"
17 - 17.5"
21 - 21"
24 - 24.5"
M - Multi
D - Down
Z - Down &
zero clearance
down flow
X - Low Nox
S - Standard
A - 1st
Design
90%+ AFUE Gas Furnaces (For Reference)
80% AFUE Gas Furnaces (For Reference)
R
H 1 T 36
17
S T A N A A 000 *
Brand Product
Category
Stages of
Airflow
Motor Type Capacity
BTU/HR
Width Coil Size Metering
Device
Major Series* Controls Voltage Minor
Series**
Factory
Heat Cap
Option
Code
Rheem
H - Air Handler 1 - Single-stage
2 - Two-stage
M - Modulating
V - Variable Speed
T - Constant Torque
P - PSC
24 - 24,000 [7.03 kW]
36 - 36,000 [10.55 kW]
48 - 48,000 [14.07 kW]
60 - 60,000 [17.58 kW]
14 - 14"
17 - 17.5"
21 - 21"
24 - 24.5"
S - Standard Efficiency
M -Mid Efficiency
H - High Efficiency
T - TEV
E - EEV
P - Piston
A -1st Design C - Communicating
N - Non-communicating
A - 1ph, 115/60
J - 1ph, 208-240/60
D - 3ph, 480/60
A -1st
Design
00 - no
factory
heat with
option
code
N/A
Air Handlers (For Reference)
Air
Model Number Identification
RP14 Series
7
[ ] Designates Metric Conversions
Page 8
Physical Data
Model No.# RP1418 RP1424 RP1430 RP1436 RP1442 RP1448 RP1460 Nominal Tonnage 1.5 2.0 2.5 3.0 3.5 4.0 5.0 Valve Connections
Liquid Line O.D. – in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Suction Line O.D. – in. 3/4 3/4 3/4 3/4 7/8 7/8 7/8
Refrigerant (R410A) furnished oz.¹ 103 100.8 118 123 167 155 244 Compressor Type Scroll Outdoor Coil
Net face area – Outer Coil 9.1 9.1 11.1 14.9 14.8 19.8 24.2
Net face area – Inner Coil
Tube diameter – in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Number of rows 1 1 1 1 1 1 1
Fins per inch 20 20 20 20 20 20 20
Outdoor Fan
Diameter – in. 20 20 20 24 24 24 26
Number of blades 2 2 3 3 2 3 3
Motor hp 1/8 1/8 1/8 1/6 1/6 1/5 1/5
CFM 2410 2410 2535 3335 2945 4055 4780
RPM 1077 1077 1077 825 850 825 850
watts 154 156 142 173 161 228 279
Shipping weight – lbs. 156 151 162 178 208 234 269 Operating weight – lbs. 149 144 155 171 201 227 262
Electrical Data
Line Voltage Data (Volts-Phase-Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Maximum overcurrent protection (amps)² 20 25 30 35 40 45 50 Minimum circuit ampacity³ 12 17 19 20 24 26 31 Compressor
Rated load amps 9 12.8 14.1 15.4 17.9 19.6 23.7
Locked rotor amps 48 58.3 73 83.9 112 130 152.5
Condenser Fan Motor
Full load amps 0.7 0.7 0.7 0.6 0.9 1.2 1
Locked rotor amps 1.2 1.2 1.2 1.5 1.2 2 2.4
Line Voltage Data (Volts-Phase-Hz) 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60
Maximum overcurrent protection (amps)² 20 30 30 35
Minimum circuit ampacity³ 14 18 19 21
Compressor
Rated load amps 10.4 13.5 13.7 15.9
Locked rotor amps 73 88 83.1 110
Condenser Fan Motor
Full load amps 0.6 0.9 1.2 1
Locked rotor amps 1.5 1.2 2 2.3
Line Voltage Data (Volts-Phase-Hz) 480-3-60 480-3-60 480-3-60 480-3-60
Maximum overcurrent protection (amps)² TBD TBD TBD TBD
Minimum circuit ampacity³ TBD TBD TBD TBD
Compressor
Rated load amps TBD TBD TBD TBD
Locked rotor amps TBD TBD TBD TBD
Condenser Fan Motor
Full load amps TBD TBD TBD TBD
Locked rotor amps TBD TBD TBD TBD
¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional
refrigerant charge required. ²HACR type circuit breaker of fuse. ³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.
Air
Physical Data/Electrical Data
RP14 Series
8
Page 9
Accessories
Model No. RP1418 RP1424 RP1430 RP1436 RP1442 RP1448 RP1460
Compressor crankcase heater 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 44-17402-45 Factory Standard
Low ambient control RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08
Compressor sound cover 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25
Compressor hard start kit SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1
Low pressure control* Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard
High pressure control* Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard
Liquid Line Solenoid (24 VAC, 50/60 Hz)
Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC
Solenoid Coil 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V
Bi-flow kit* KS30387 KS30387 KS30387 KS30387 KS30387 KS30387 KS30387
Liquid Line Solenoid (120/240 VAC, 50/60 Hz)
Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC
Solenoid Coil 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V
Bi-flow kit* KS30387 KS30387 KS30387 KS30387 KS30387 KS30387 KS30387
Classic Top Cap w/Label 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21
*Bi-flow kits are required when installing a liquid line solenoid on a heat pump.
Weighted Sound Power Level (dBA)
RP14 SOUND POWER LEVEL
Model
Sound Power Level
[dB(A)]
Full Octave Linear Sound Power Level dB - Center Frequency - Hz
Sound Power Level [dB(A)] with
Sound Blanket
125 250 500 1000 2000 4000 6300 8000
RP1418A 75.2 53.8 60.2 64.3 66 62.5 57.6 54.6 53.5 74.6 RP1424A 75.4 55.9 59.8 64.8 66.1 62.3 57.7 55.6 53 75.2 RP1430A 76.5 60.8 60.5 65.4 66.9 63.9 59.9 55.2 53.1 75.9 RP1436A 74.3 50.5 58 63.5 65.1 61.2 56.1 55.9 53.7 73.2 RP1442A 76.4 51.9 59 64.4 68.7 63.5 57.4 54 53 74.9 RP1448A 77.5 54.5 55.1 64.4 67.3 64.3 58.2 55.8 53.6 75.2 RP1460A 77.2 53.9 56.3 65.7 70.3 65.4 61.2 58.8 55.8 75.4
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)
* Photos are representative. Actual models may vary.
For detailed thermostat match-up information, see specification sheet form number T11-001.
300-Series *
Deluxe Programmable
400-Series *
Special Applications/ Programmable
500-Series *
Communicating/ Programmable
200-Series *
Programmable
Thermostats
Air
Accessories/Weighted Sound Power/Thermostats
RP14 Series
9
Page 10
Unit Dimensions
MODEL
NUMBER
OPERATING SHIPPING
H (Height) L (Length) W (Width) H (Height) L (Length) W (Width)
INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm
RP1418 25 635 29.75 755 29.75 755
26.75 679 32.38 822 32.38 822
RP1424 25 635 29.75 755 29.75 755
26.75 679 32.38 822 32.38 822
RP1430 25 635 29.75 755 29.75 755
26.75 679 32.38 822 32.38 822
RP1436 27 685 33.75 857 33.75 857
28.75 679 36.38 924 36.38 924
RP1442 27 685 33.75 857 33.75 857
28.75 679 36.38 924 36.38 924
RP1448 35 889 33.75 857 33.75 857
36.75 933 36.38 924 36.38 924
RP1460 39 990 35.75 908 35.75 908
40.75 1035 38.38 975 38.38 975
[ ] Designates Metric Conversions
ST-A1226-02-00
Air
Unit Dimensions
RP14 Series
10
Page 11
6
(152.4)
24
(609.6)
Service
12
(304.8)
6
(152.4)
24
(609.6)
Service
24
(609.6)
24 recommended
12 minimum
12
(304.8)
12
(304.8)
6
(152.4)
24
(609.6)
Service
24
(609.6)
Service
24
(609.6)
Service
18
(457.2)
WALL
WALL
WALL
WALL
NOTE: NUMBERS IN () = mm
CLEARANCES
IMPORTANT: When installing multiple units in an alcove, roof well or partially enclosed area, ensure there is adequate ventillation to prevent re-circulation of discharge air.
ST-A1225-01-00
24
(609.6)
24 recommended
12 minimum
Air
Clearances
RP14 Series
11
Page 12
Air
Wiring Diagram/Application Guidelines
RP14 Series
12
.
Application Guidelines
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc.
2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).
3. Maximum outdoor operating air temperature is 125°F (51.7°C).
4. For reliable operation, unit should be level in all horizontal planes.
5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector
provided.
6. Do not apply capillary tube indoor coils to these units.
7. Factory – supplied filter drier must be installed.
Control Wiring
FIGURE 4
CONTROL WIRING FOR AIR HANDLER
Air Handler
W/BL
W2
G/BK
G
Y
Y
W/BK
W1
BL
B
G/Y
ODD
BR
C
R
R
Y
Heat Pump Thermostat
W2
G
B
Y
TYPICAL THERMOSTAT:
C
E
HEAT PUMP WITH
R
ELECTRIC HEAT
Heat Pump Outdoor Unit
Y
B
NOTES:
1. Jumper “E” to “W2” to transfer control of supplemental heat to 1st stage when the emergency heat switch is on.
2. This wire turns on heat for defrost, omit for most economical operation.
3. Wire with colored tracing stripe.
C
R
D
WIRING INFORMATION
Line Voltage
Field Installed
-
Factory Standard
-
NOTE: RED WIRE REQUIRED WITH RANCO DDL DEMAND DEFROST CONTROL
Page 13
Air
Refrigerant Line Size Information
RA14 Series
13
R-410A System
Capacity Model
Liquid Line Size
Connection Size
(Inch I.D.) [mm]
Liquid Line Size
(Inch O.D.) [mm]
Liquid Line Selection Chart
Elevation (Above or Below) Indoor Coil
Tot al Equivalent Length - Feet [m]
25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 125 [45.72] 150 [45.72] 175 [53.34] 200 [60.96] 225 [68.58] 250 [76.20] 275 [83.82] 300 [91.44]
Maximum Vertical Separation – Feet [m]
18 3/8" [9.53]
1/4 [6.35] 25 [7.62] 50 [15.24] 60 [18.29] 50 [15.24] 35 [10.67] 20 [6.1]
N/R N/R N/R N/R N/R N/R
5/16 [7.94] 25 [7.62] 50 [15.24] 75 [22.86] 90 [27.43] 85 [25.91] 85 [25.91] 80 [24.38] 75 [22.86] 70 [21.34] 70 [21.34] 65 [19.81] 60 [18.29]
3/8 [9.53] 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 100 [30.48] 100 [30.48] 95 [28.96] 95 [28.96] 95 [28.96] 90 [27.43] 90 [27.43] 90 [27.43]
7/16 [11.12] 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 105 [32] 100 [30.48] 100 [30.48] 100 [30.48] 100 [30.48] 100 [30.48] 100 [30.48] 100 [30.48]
1/2 [12.71] 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 105 [32] 105 [32] 105 [32] 105 [32] 105 [32] 105 [32] 100 [30.48] 100 [30.48]
24 3/8" [9.53]
1/4 [6.35] 25 [7.62] 50 [15.24] 30 [9.14] 10 [3.05]
N/R N/R N/R N/R N/R N/R N/R N/R
5/16 [7.94] 25 [7.62] 50 [15.24] 75 [22.86] 80 [24.38] 75 [22.86] 70 [21.34] 60 [18.29] 55 [16.76] 50 [15.24] 45 [13.72] 35 [10.67] 30 [9.14]
3/8 [9.53] 25 [7.62] 50 [15.24] 75 [22.86] 95 [28.96] 95 [28.96] 95 [28.96] 90 [27.43] 90 [27.43] 85 [25.91] 85 [25.91] 80 [24.38] 80 [24.38]
7/16 [11.12] 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 100 [30.48] 100 [30.48] 100 [30.48] 100 [30.48] 100 [30.48] 95 [28.96] 95 [28.96] 95 [28.96]
1/2 [12.71] 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 100 [30.48] 100 [30.48] 100 [30.48] 100 [30.48] 100 [30.48] 100 [30.48] 100 [30.48] 100 [30.48]
30 3/8" [9.53]
1/4 [6.35] 25 [7.62] 30 [9.14]
N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
5/16 [7.94] 25 [7.62] 50 [15.24] 75 [22.86] 65 [19.81] 55 [16.76] 50 [15.24] 40 [12.19] 30 [9.14] 25 [7.62] 15 [4.57] 5 [1.52]
N/R
3/8 [9.53] 25 [7.62] 50 [15.24] 75 [22.86] 90 [27.43] 85 [25.91] 80 [24.38] 80 [24.38] 75 [22.86] 75 [22.86] 70 [21.34] 65 [19.81] 65 [19.81]
7/16 [11.12] 25 [7.62] 50 [15.24] 75 [22.86] 95 [28.96] 95 [28.96] 90 [27.43] 90 [27.43] 90 [27.43] 90 [27.43] 85 [25.91] 85 [25.91] 85 [25.91]
1/2 [12.71] 25 [7.62] 50 [15.24] 75 [22.86] 95 [28.96] 95 [28.96] 95 [28.96] 95 [28.96] 95 [28.96] 95 [28.96] 95 [28.96] 95 [28.96] 90 [27.43]
36 3/8" [9.53]
1/4 [6.35] 25 [7.62]
N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
5/16 [7.94] 25 [7.62] 50 [15.24] 55 [16.76] 45 [13.72] 30 [9.14] 20 [6.1]
N/R N/R N/R N/R N/R N/R
3/8 [9.53] 25 [7.62] 50 [15.24] 75 [22.86] 75 [22.86] 70 [21.34] 70 [21.34] 65 [19.81] 60 [18.29] 55 [16.76] 50 [15.24] 45 [13.72] 40 [12.19]
7/16 [11.12] 25 [7.62] 50 [15.24] 75 [22.86] 85 [25.91] 85 [25.91] 85 [25.91] 80 [24.38] 80 [24.38] 80 [24.38] 75 [22.86] 75 [22.86] 70 [21.34]
1/2 [12.71] 25 [7.62] 50 [15.24] 75 [22.86] 90 [27.43] 90 [27.43] 90 [27.43] 90 [27.43] 85 [25.91] 85 [25.91] 85 [25.91] 85 [25.91] 85 [25.91]
42 3/8" [9.53]
1/4 [6.35] 5 [1.52]
N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
5/16 [7.94] 25 [7.62] 40 [12.19] 25 [7.62] 5 [1.52]
N/R N/R N/R N/R N/R N/R N/R N/R
3/8 [9.53] 25 [7.62] 50 [15.24] 60 [18.29] 50 [15.24] 45 [13.72] 40 [12.19] 35 [10.67] 30 [9.14] 20 [6.1] 15 [4.57] 10 [3.05]
N/R
7/16 [11.12] 25 [7.62] 50 [15.24] 70 [21.34] 65 [19.81] 65 [19.81] 60 [18.29] 60 [18.29] 55 [16.76] 55 [16.76] 50 [15.24] 50 [15.24] 45 [13.72]
1/2 [12.71] 25 [7.62] 50 [15.24] 70 [21.34] 70 [21.34] 70 [21.34] 70 [21.34] 65 [19.81] 65 [19.81] 65 [19.81] 65 [19.81] 60 [18.29] 60 [18.29]
48 3/8" [9.53]
1/4 [6.35]
N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
5/16 [7.94] 25 [7.62] 35 [10.67] 10 [3.05]
N/R N/R N/R N/R N/R N/R N/R N/R N/R
3/8 [9.53] 25 [7.62] 50 [15.24] 55 [16.76] 45 [13.72] 40 [12.19] 30 [9.14] 25 [7.62] 15 [4.57] 10 [3.05]
N/R N/R N/R
7/16 [11.12] 25 [7.62] 50 [15.24] 70 [21.34] 65 [19.81] 60 [18.29] 60 [18.29] 55 [16.76] 50 [15.24] 50 [15.24] 45 [13.72] 45 [13.72] 40 [12.19]
1/2 [12.71] 25 [7.62] 50 [15.24]. 75 [22.86] 70 [21.34] 70 [21.34] 70 [21.34] 65 [19.81] 65 [19.81] 65 [19.81] 65 [19.81] 60 [18.29] 60 [18.29]
60 3/8" [9.53]
1/4 [6.35]
N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
5/16 [7.94] 25 [7.62] 10 [3.05]
N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
3/8 [9.53] 25 [7.62]. 50 [15.24] 40 [12.19] 30 [9.14] 20 [6.1] 10 [3.05]
N/R N/R N/R N/R N/R N/R
7/16 [11.12] 25 [7.62] 50 [15.24] 60 [18.29] 55 [16.76] 50 [15.24] 45 [13.72] 40 [12.19] 40 [12.19] 35 [10.67] 30 [9.14] 25 [7.62] 20 [6.1]
1/2 [12.71] 25 [7.62] 50 [15.24] 65 [19.81] 65 [19.81] 60 [18.29] 60 [18.29] 60 [18.29] 55 [16.76] 55 [16.76] 50 [15.24] 50 [15.24] 50 [15.24]
Heat Pump Refrigerant Line Size Information
NOTES: [ ] Designates Metric Conversions
N/R = Application not recommended.
Grey =This application is acceptable, but the long line guidelines must be followed. Reference Long Line Set section in the I&O
Page 14
Air
Refrigerant Line Size Information
RA14 Series
14
R-410A System
Capacity Model
Vapor Line
Connection Size
(Inch I.D.) [mm]
Vapor Line Size
(Inch O.D.) [mm]
Vapor Line Selection Chart
Capacity Multiplier Table
Tot al Equivalent Length - Feet [m]
25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 125 [45.72] 150 [45.72] 175 [53.34] 200 [60.96] 225 [68.58] 250 [76.20] 275 [83.82] 300 [91.44]
18 3/4" [19.06]
5/8 [15.88] 1.00 0.99 0.99 0.99 0.99 0.98 0.98 0.98 0.97 0.97 0.97 0.97
3/4 [19.05] 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
7/8 [22.23]
N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
1 [25.4]
N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
1-1/8 [28.58]
N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
24 3/4" [19.06]
5/8 [15.88] 0.99 0.99 0.98 0.98 0.97 0.97 0.96 0.96 0.96 0.95 0.95 0.94
3/4 [19.05] 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.99 0.99 0.99 0.99
7/8 [22.23] 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.01 1.01 1.01 1.01
1 [25.4]
N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
1-1/8 [28.58]
N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
30 3/4" [19.06]
5/8 [15.88] 0.99 0.98 0.97 0.96 0.96 0.94 0.93 0.93 0.93 0.91 0.91 0.9
3/4 [19.05] 1.00 1.00 1.00 0.99 0.98 0.98 0.98 0.98 0.98 0.97 0.96 0.96
7/8 [22.23] 1.00 1.01 1.01 1.00 1.00 1.01 1.01 1.00 1.00 1.00 1.00 0.99
1 [25.4] 1.00 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.00
1-1/8 [28.58]
N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
36 3/4" [19.06]
5/8 [15.88] 0.99 0.97 0.95 0.93 0.92 0.91 0.9 0.9 0.9 0.87 0.87 0.86
3/4 [19.05] 1.00 0.99 0.98 0.98 0.97 0.97 0.97 0.96 0.96 0.95 0.94 0.94
7/8 [22.23] 1.00 1.00 1.00 1.00 0.99 0.99 0.99 0.99 0.99 0.98 0.98 0.98
1 [25.4] 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
1-1/8 [28.58]
N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
42 7/8" [22.23]
5/8 [15.88] 0.98 0.97 0.95 0.94 0.92 0.91 0.89 0.88 0.87 0.86 0.85
N/R
3/4 [19.05] 0.99 0.98 0.98 0.98 0.97 0.97 0.96 0.96 0.95 0.95 0.94
N/R
7/8 [22.23] 1.00 1.00 1.00 0.99 1.00 0.99 0.99 0.99 0.98 0.98 0.98
N/R
1 [25.4] 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.99 0.99 1.00
N/R
1-1/8 [28.58] 1.01 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.01
N/R
48 7/8" [22.23]
5/8 [15.88] 0.97 0.95 0.94 0.92 0.89 0.88 0.86 0.86 0.84
N/R N/R N/R
3/4 [19.05] 0.99 0.99 0.98 0.97 0.96 0.96 0.95 0.94 0.93
N/R N/R N/R
7/8 [22.23] 1.00 0.99 0.99 0.99 0.98 0.98 0.98 0.97 0.97
N/R N/R N/R
1 [25.4] 1.00 1.00 1.00 0.99 0.99 1.00 0.99 1.00 0.99
N/R N/R N/R
1-1/8 [28.58]
N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
60 7/8" [22.23]
5/8 [15.88] 0.98 0.94 0.92 0.9 0.88 0.85
N/R N/R N/R N/R N/R N/R
3/4 [19.05] 1.00 0.99 0.98 0.96 0.95 0.94
N/R N/R N/R N/R N/R N/R
7/8 [22.23] 1.00 1.00 1.00 0.99 0.99 0.98
N/R N/R N/R N/R N/R N/R
1 [25.4] 1.01 1.00 1.01 1.01 1.00 1.00
N/R N/R N/R N/R N/R N/R
1-1/8 [28.58]
N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
Heat Pump Refrigerant Line Size Information (con’t.)
NOTES: [ ] Designates Metric Conversions
N/R = Application not recommended.
All calculations assume a 3/8" liquid line
Page 15
Air
Performance Data
RP14 Series
15
High Sales Volume Tested Combination (HSVTC)
Outdoor
Unit
Air Handler
Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
SEER EER
Indoor CFM
[L/s]
47 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
17 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
Region
IV HSPF
AHRI#
RP1418AJ1 RH1T2417STAN 18800 [5.5] 13700 [4.0] 5100 [1.5] 14 11.5 575 [271.4] 17000 [5.0] 3.6 10200 [3.0] 2.4 8.2 7489173
RP1424AJ1 RH1T2417STAN 23800 [7.0] 17600 [5.2] 6200 [1.8] 14 11.5 825 [389.4] 22800 [6.7] 3.6 12600 [3.7] 2.34 8.2 7489174
RP1430AJ1 RH1T3617STAN 28800 [8.4] 22200 [6.5] 6600 [1.9] 14 11.5 1050 [495.5] 27400 [8.0] 3.5 16600 [4.9] 2.34 8.2 7489175
RP1436AC1 RH1T3617STAN 35200 [10.3] 26200 [7.7] 9000 [2.6] 14 11.5 1200 [566.3] 34800 [10.2] 3.66 23200 [6.8] 2.54 8.2 7489177
RP1436AJ1 RH1T3617STAN 35200 [10.3] 26200 [7.7] 9000 [2.6] 14 11.5 1200 [566.3] 34800 [10.2] 3.66 23200 [6.8] 2.54 8.2 7489178
RP1442AC1 RH1T4821STAN 42500 [12.5] 32400 [9.5] 10100 [3.0] 14 11.5 1400 [660.7] 39000 [11.4] 3.6 24800 [7.3] 2.5 8.2 7489179
RP1442AJ1 RH1T4821STAN 42500 [12.5] 32400 [9.5] 10100 [3.0] 14 11.5 1400 [660.7] 39000 [11.4] 3.6 24800 [7.3] 2.5 8.2 7489180
RP1448AC1 RH1T4821STAN 48000 [14.1] 35700 [10.5] 12300 [3.6] 14 11.5 1525 [719.7] 46000 [13.5] 3.6 29800 [8.7] 2.6 8.2 7489181
RP1448AJ1 RH1T4821STAN 48000 [14.1] 35700 [10.5] 12300 [3.6] 14 11.5 1525 [719.7] 46000 [13.5] 3.6 29800 [8.7] 2.6 8.2 7489182
RP1460AC1 RH1T6024STAN 56500 [16.6] 40800 [12.0] 15700 [4.6] 14 11.5 1800 [849.5] 57000 [16.7] 3.8 35800 [10.5] 2.66 8.2 7489183
RP1460AJ1 RH1T6024STAN 56500 [16.6] 40800 [12.0] 15700 [4.6] 14 11.5 1800 [849.5] 57000 [16.7] 3.8 35800 [10.5] 2.66 8.2 7489184
Performance Data @ AHRI Standard Conditions – Heat Pump
RGPT: Single Stage Upflow Constant Torque 80% Furnace Ratings
Outdoor
Unit
Furnace Indoor Coil
Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
SEER EER
Indoor CFM
[L/s]
47 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
17 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
Region
IV HSPF
AHRI#
RP1418AJ1 RGPT-05?BMK? RCF2417STAM 19000 [5.6] 14000 [4.1] 5000 [1.5] 14 11.5 650 [306.8] 17100 [5.0] 3.54 10400 [3.0] 2.4 8.2 7492684
RP1418AJ1 RGPT-07?AMK? RCF2417STAM 18900 [5.5] 13800 [4.0] 5100 [1.5] 14 11.5 625 [295.0] 17100 [5.0] 3.6 10400 [3.0] 2.4 8.2 7492685
RP1424AJ1 RGPT-07?AMK? RCF2417STAM 24000 [7.0] 17900 [5.2] 6100 [1.8] 14 11.5 875 [413.0] 22800 [6.7] 3.54 12800 [3.8] 2.34 8.2 7492694
RP1430AJ1 RGPT-07?BRQ? RCF3621STAM 28600 [8.4] 21700 [6.4] 6900 [2.0] 14 11.5 1000 [471.9] 27400 [8.0] 3.54 16400 [4.8] 2.34 8.2 7492708
RP1430AJ1 RGPT-10?BRM? RCF3621STAM 28600 [8.4] 21700 [6.4] 6900 [2.0] 14 11.5 1000 [471.9] 27400 [8.0] 3.54 16500 [4.8] 2.34 8.2 7492709
RP1436AC1 RGPT-07?BRQ? RCF3621STAM 35000 [10.3] 25900 [7.6] 9100 [2.7] 14 11.5 1175 [554.5] 34800 [10.2] 3.7 22400 [6.6] 2.54 8.2 7492717
RP1436AC1 RGPT-10?BRM? RCF3621STAM 35000 [10.3] 25900 [7.6] 9100 [2.7] 14 11.5 1175 [554.5] 34800 [10.2] 3.7 22400 [6.6] 2.54 8.2 7492718
RP1436AJ1 RGPT-07?BRQ? RCF3621STAM 35000 [10.3] 25900 [7.6] 9100 [2.7] 14 11.5 1175 [554.5] 34800 [10.2] 3.7 22400 [6.6] 2.54 8.2 7492724
RP1436AJ1 RGPT-10?BRM? RCF3621STAM 35000 [10.3] 25900 [7.6] 9100 [2.7] 14 11.5 1175 [554.5] 34800 [10.2] 3.7 22400 [6.6] 2.54 8.2 7492725
[ ] Designates Metric Conversions
Page 16
Air
Performance Data
RP14 Series
16
RGPE: Two-Stage, Variable Speed 80% (upflow/horizontal) furnace with Comfort Control System Ratings
Outdoor
Unit
Furnace Indoor Coil
Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
SEER EER
Indoor CFM
[L/s]
47 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
17 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
Region
IV HSPF
AHRI#
RP1418AJ1 RGPE-05?BMK? RCF2417STAM 18800 [5.5] 13600 [4.0] 5200 [1.5] 14 11.5 575 [271.4] 17100 [5.0] 3.6 10200 [3.0] 2.34 8.2 7492682
RP1418AJ1 RGPE-07?AMK? RCF2417STAM 19000 [5.6] 13900 [4.1] 5100 [1.5] 14 11.5 625 [295.0] 17000 [5.0] 3.6 10300 [3.0] 2.4 8.2 7492683
RP1424AJ1 RGPE-05?BMK? RCF2417STAM 23400 [6.9] 17000 [5.0] 6400 [1.9] 14 11.5 750 [354.0] 22400 [6.6] 3.5 12400 [3.6] 2.26 8.2 7492692
RP1424AJ1 RGPE-07?AMK? RCF2417STAM 23800 [7.0] 17600 [5.2] 6200 [1.8] 14 11.5 825 [389.4] 22800 [6.7] 3.6 12700 [3.7] 2.34 8.2 7492693
RP1430AJ1 RGPE-07?BRQ? RCF3621STAM 28800 [8.4] 22100 [6.5] 6700 [2.0] 14 11.5 1050 [495.5] 27400 [8.0] 3.54 16500 [4.8] 2.34 8.2 7492706
RP1430AJ1 RGPE-10?BRM? RCF3621STAM 28800 [8.4] 22200 [6.5] 6600 [1.9] 14 11.5 1075 [507.3] 27400 [8.0] 3.54 16500 [4.8] 2.34 8.2 7492707
RP1436AC1 RGPE-07?BRQ? RCF3621STAM 35200 [10.3] 26200 [7.7] 9000 [2.6] 14 11.5 1225 [578.1] 34800 [10.2] 3.7 22400 [6.6] 2.54 8.2 7492715
RP1436AC1 RGPE-10?BRM? RCF3621STAM 35200 [10.3] 26200 [7.7] 9000 [2.6] 14 11.5 1225 [578.1] 34800 [10.2] 3.7 22400 [6.6] 2.54 8.2 7492716
RP1436AJ1 RGPE-07?BRQ? RCF3621STAM 35200 [10.3] 26200 [7.7] 9000 [2.6] 14 11.5 1225 [578.1] 34800 [10.2] 3.7 22400 [6.6] 2.54 8.2 7492722
RP1436AJ1 RGPE-10?BRM? RCF3621STAM 35200 [10.3] 26200 [7.7] 9000 [2.6] 14 11.5 1225 [578.1] 34800 [10.2] 3.7 22400 [6.6] 2.54 8.2 7492723
Performance Data @ AHRI Standard Conditions – Heat Pump (con’t.)
R95T: 95% AFUE single-stage Constant Torque Multipoise Gas Furnace Ratings
Outdoor
Unit
Furnace Indoor Coil
Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
SEER EER
Indoor CFM
[L/s]
47 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
17 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
Region
IV HSPF
AHRI#
RP1418AJ1 R95TA0401317MSA RCF2417STAM 19000 [5.6] 14000 [4.1] 5000 [1.5] 14 11.5 650 [306.8] 17200 [5.0] 3.54 10400 [3.0] 2.4 8.2 7492676
RP1430AJ1 R95TA0401317MSA RCF3621STAM 28200 [8.3] 21100 [6.2] 7100 [2.1] 14 11.5 950 [448.4] 27000 [7.9] 3.46 16300 [4.8] 2.3 8.2 7492702
R96V: 96% AFUE 2-stage Variable Speed Multipoise Gas Furnace Ratings
Outdoor
Unit
Furnace Indoor Coil
Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
SEER EER
Indoor CFM
[L/s]
47 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
17 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
Region
IV HSPF
AHRI#
RP1418AJ1 R96VA0702317MSA RCF2417STAM 19000 [5.6] 14000 [4.1] 5000 [1.5] 14 11.5 650 [306.8] 17100 [5.0] 3.54 10400 [3.0] 2.4 8.2 7492677
RP1430AJ1 R96VA1002521MSA RCF3621STAM 28800 [8.4] 22100 [6.5] 6700 [2.0] 14 11.45 1050 [495.5] 27400 [8.0] 3.5 16500 [4.8] 2.3 8.2 7492703
RGFG: 95 Plus Communicating Modulating Upflow Gas Furnace equipped with Confront Control, ECM Ratings
Outdoor
Unit
Furnace Indoor Coil
Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
SEER EER
Indoor CFM
[L/s]
47 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
17 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
Region
IV HSPF
AHRI#
RP1418AJ1 RGFG-06?MCK? RCF2417STAM 18700 [5.5] 13500 [4.0] 5200 [1.5] 14 11.5 575 [271.4] 17100 [5.0] 3.6 10200 [3.0] 2.34 8.2 7492678
RP1418AJ1 RGFG-07?MCK? RCF2417STAM 19000 [5.6] 14000 [4.1] 5000 [1.5] 14 11.5 650 [306.8] 17100 [5.0] 3.54 10400 [3.0] 2.4 8.2 7492679
[ ] Designates Metric Conversions
Page 17
17
Air
Performance Data
RP14 Series
17
RGJF: 90 Plus Communicating Modulating Horizontal Gas Furnace equipped with Comfort Control, ECM Ratings
Outdoor
Unit
Furnace Indoor Coil
Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
SEER EER
Indoor CFM
[L/s]
47 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
17 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
Region
IV HSPF
AHRI#
RP1418AJ1 RGJF-06?MCK? RCF2417STAM 18900 [5.5] 13800 [4.0] 5100 [1.5] 14 11.5 625 [295.0] 17100 [5.0] 3.6 10400 [3.0] 2.4 8.2 7492680
RP1418AJ1 RGJF-07?MCK? RCF2417STAM 18800 [5.5] 13600 [4.0] 5200 [1.5] 14 11.5 575 [271.4] 17000 [5.0] 3.6 10200 [3.0] 2.34 8.2 7492681
RP1424AJ1 RGJF-06?MCK? RCF2417STAM 23800 [7.0] 17600 [5.2] 6200 [1.8] 14 11.5 825 [389.4] 22800 [6.7] 3.6 12700 [3.7] 2.34 8.2 7492690
RP1424AJ1 RGJF-07?MCK? RCF2417STAM 23400 [6.9] 17000 [5.0] 6400 [1.9] 14 11.5 750 [354.0] 22400 [6.6] 3.5 12400 [3.6] 2.26 8.2 7492691
RP1430AJ1 RGJF-09?ZCM? RCF3621STAM 28400 [8.3] 21500 [6.3] 6900 [2.0] 14 11.45 1000 [471.9] 27000 [7.9] 3.46 16300 [4.8] 2.3 8.2 7492704
RP1430AJ1 RGJF-10?ZCM? RCF3621STAM 28400 [8.3] 21500 [6.3] 6900 [2.0] 14 11.4 1000 [471.9] 27000 [7.9] 3.46 16300 [4.8] 2.3 8.2 7492705
Performance Data @ AHRI Standard Conditions – Heat Pump (con’t.)
ROCA Oil Furnace Ratings
Outdoor
Unit
Furnace Indoor Coil
Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
SEER EER
Indoor CFM
[L/s]
47 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
17 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
Region
IV HSPF
AHRI#
RP1418AJ1 ROCA-070E03 RCF2417STAM 18800 [5.5] 13700 [4.0] 5100 [1.5] 14 11.5 600 [283.2] 17000 [5.0] 3.6 10300 [3.0] 2.4 8.2 7492686
RP1418AJ1 ROCA-070E04 RCF2417STAM 18800 [5.5] 13700 [4.0] 5100 [1.5] 14 11.5 600 [283.2] 17000 [5.0] 3.6 10300 [3.0] 2.4 8.2 7492687
RP1424AJ1 ROCA-070E03 RCF2417STAM 23800 [7.0] 17500 [5.1] 6300 [1.8] 14 11.5 800 [377.6] 22800 [6.7] 3.6 12500 [3.7] 2.34 8.2 7492695
RP1424AJ1 ROCA-070E04 RCF2417STAM 23800 [7.0] 17500 [5.1] 6300 [1.8] 14 11.5 800 [377.6] 22800 [6.7] 3.6 12500 [3.7] 2.34 8.2 7492696
RP1430AJ1 ROCA-070E03 RCF3621STAM 28400 [8.3] 21500 [6.3] 6900 [2.0] 14 11.45 1000 [471.9] 27000 [7.9] 3.46 16300 [4.8] 2.3 8.2 7492710
RP1430AJ1 ROCA-070E04 RCF3621STAM 28400 [8.3] 21500 [6.3] 6900 [2.0] 14 11.45 1000 [471.9] 27000 [7.9] 3.46 16300 [4.8] 2.3 8.2 7492711
ROLA Oil Furnace Ratings
Outdoor
Unit
Furnace Indoor Coil
Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
SEER EER
Indoor CFM
[L/s]
47 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
17 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
Region
IV HSPF
AHRI#
RP1418AJ1 ROLA-070E03 RCF2417STAM 18700 [5.5] 13600 [4.0] 5100 [1.5] 14 11.5 600 [283.2] 17100 [5.0] 3.6 10400 [3.0] 2.4 8.2 7492688
RP1424AJ1 ROLA-070E03 RCF2417STAM 24200 [7.1] 18200 [5.3] 6000 [1.8] 14 11.5 900 [424.8] 22800 [6.7] 3.54 12700 [3.7] 2.34 8.2 7492697
RP1424AJ1 ROLA-070E04 RCF2417STAM 24200 [7.1] 18200 [5.3] 6000 [1.8] 14 11.5 900 [424.8] 22800 [6.7] 3.54 12700 [3.7] 2.34 8.2 7492698
RP1430AJ1 ROLA-070E03
RCF3617STAM 28400 [8.3] 21400 [6.3] 7000 [2.1] 14 11.45 975 [460.1] 26800 [7.9] 3.4 16200 [4.7] 2.26 8.2 7492700
RCF3621STAM 28400 [8.3] 21400 [6.3] 7000 [2.1] 14 11.5 975 [460.1] 26800 [7.9] 3.46 16100 [4.7] 2.3 8.2 7492712
RP1430AJ1 ROLA-070E04
RCF3617STAM 28400 [8.3] 21400 [6.3] 7000 [2.1] 14 11.45 975 [460.1] 26800 [7.9] 3.4 16200 [4.7] 2.26 8.2 7492701
RCF3621STAM 28600 [8.4] 21800 [6.4] 6800 [2.0] 14 11.5 1025 [483.7] 27200 [8.0] 3.5 16400 [4.8] 2.3 8.2 7492713
RP1430AJ1 ROLA-115E05 RCF3621STAM 28800 [8.4] 22100 [6.5] 6700 [2.0] 14 11.5 1050 [495.5] 27400 [8.0] 3.5 16500 [4.8] 2.34 8.2 7492714
RP1436AC1 ROLA-070E03 RCF3621STAM 35000 [10.3] 25900 [7.6] 9100 [2.7] 14 11.5 1175 [554.5] 34600 [10.1] 3.66 22200 [6.5] 2.54 8.2 7492719
RP1436AC1 ROLA-070E04 RCF3621STAM 35000 [10.3] 25900 [7.6] 9100 [2.7] 14 11.5 1175 [554.5] 34600 [10.1] 3.66 22200 [6.5] 2.54 8.2 7492720
RP1436AC1 ROLA-115E05 RCF3621STAM 35200 [10.3] 26200 [7.7] 9000 [2.6] 14 11.5 1200 [566.3] 34800 [10.2] 3.7 22400 [6.6] 2.54 8.2 7492721
RP1436AJ1 ROLA-070E03 RCF3621STAM 35000 [10.3] 25900 [7.6] 9100 [2.7] 14 11.5 1175 [554.5] 34600 [10.1] 3.66 22200 [6.5] 2.54 8.2 7492726
RP1436AJ1 ROLA-070E04 RCF3621STAM 35000 [10.3] 25900 [7.6] 9100 [2.7] 14 11.5 1175 [554.5] 34600 [10.1] 3.66 22200 [6.5] 2.54 8.2 7492727
RP1436AJ1 ROLA-115E05 RCF3621STAM 35200 [10.3] 26200 [7.7] 9000 [2.6] 14 11.5 1200 [566.3] 34800 [10.2] 3.7 22400 [6.6] 2.54 8.2 7492728
[ ] Designates Metric Conversions
Page 18
18
Air
Performance Data
RP14 Series
Air Handler Ratings
Outdoor
Unit
Air Handler
Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
SEER EER
Indoor CFM
[L/s]
47 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
17 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
Region
IV HSPF
AHRI#
RP1418AJ1
RH1V2417STAN 19100 [5.6] 14100 [4.1] 5000 [1.5] 14 11.5 650 [306.8] 17000 [5.0] 3.6 10300 [3.0] 2.4 8.2 7492689
RH1V2417STAN 23800 [7.0] 17600 [5.2] 6200 [1.8] 14 11.5 850 [401.2] 22800 [6.7] 3.6 12600 [3.7] 2.34 8.2 7492699
RH1V3617STAN 28600 [8.4] 21800 [6.4] 6800 [2.0] 14 11.5 1025 [483.7] 27200 [8.0] 3.46 16400 [4.8] 2.3 8.2 7489176
RP1442AC1 RH1T4824STAN 42500 [12.5] 33200 [9.7] 9300 [2.7] 14 11.5 1550 [731.5] 39500 [11.6] 3.54 25000 [7.3] 2.46 8.2 7492729
RP1442AJ1 RH1T4824STAN 42500 [12.5] 33200 [9.7] 9300 [2.7] 14 11.5 1550 [731.5] 39500 [11.6] 3.54 25000 [7.3] 2.46 8.2 7492730
RP1448AC1
RH1T4824STAN 48000 [14.1] 35700 [10.5] 12300 [3.6] 14 11.5 1550 [731.5] 45500 [13.3] 3.66 29800 [8.7] 2.66 8.2 7492731
RH1V4821STAN 47000 [13.8] 33700 [9.9] 13300 [3.9] 14 11.5 1400 [660.7] 45000 [13.2] 3.6 29200 [8.6] 2.54 8.2 7492732
RH1V4824STAN 48500 [14.2] 36700 [10.8] 11800 [3.5] 14 11.5 1625 [766.9] 45500 [13.3] 3.66 29800 [8.7] 2.66 8.2 7492733
RP1448AJ1
RH1T4824STAN 48000 [14.1] 35700 [10.5] 12300 [3.6] 14 11.5 1550 [731.5] 45500 [13.3] 3.66 29800 [8.7] 2.66 8.2 7492734
RH1V4821STAN 47000 [13.8] 33700 [9.9] 13300 [3.9] 14 11.5 1400 [660.7] 45000 [13.2] 3.6 29200 [8.6] 2.54 8.2 7492735
RH1V4824STAN 48500 [14.2] 36700 [10.8] 11800 [3.5] 14 11.5 1625 [766.9] 45500 [13.3] 3.66 29800 [8.7] 2.66 8.2 7492736
RP1460AC1 RH1V6024STAN 56500 [16.6] 40700 [11.9] 15800 [4.6] 14 11.5 1800 [849.5] 57000 [16.7] 3.84 35800 [10.5] 2.7 8.2 7492737
RP1460AJ1 RH1V6024STAN 56500 [16.6] 40700 [11.9] 15800 [4.6] 14 11.5 1800 [849.5] 57000 [16.7] 3.84 35800 [10.5] 2.7 8.2 7492738
Performance Data @ AHRI Standard Conditions – Heat Pump (con’t.)
[ ] Designates Metric Conversions
Page 19
Air
Guide Specifications
RP14 Series
19
GUIDE SPECIFICATIONS
General
System Description
Outdoor-mounted, air-cooled, split-system heat pump unit suit­able for ground or rooftop installation. Unit consists of a hermetic compressor, composite basepan, an air-cooled coil, propeller­type condenser fan, suction and liquid line service valve, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a coil unit.
Quality Assurance
— Unit will be rated in accordance with the latest edition of AHRI
Standard 210.
— Unit will be certified for capacity and efficiency, and listed in
the latest AHRI directory.
— Unit construction will comply with latest edition of ANSI/
ASHRAE and with NEC.
— Unit will be constructed in accordance with UL standards and
will carry the UL label of approval. Unit will have c-UL-us approval.
— Unit cabinet will be capable of withstanding ASTM B117 1000-
hr salt spray test.
— Air-cooled condenser coils will be leak tested at 150 psig and
pressure tested at 550 psig.
— Unit constructed in ISO9001 approved facility.
Delivery, Storage, and Handling
— Unit will be shipped as single package only and is stored and
handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer) — U.S. and Canada only.
Products
Equipment
Factory assembled, single piece, air-cooled heat pump unit. Con­tained within the unit enclosure is all factory wiring, piping, con­trols, compressor, refrigerant charge R-410A, and special fea­tures required prior to field start-up.
Unit Cabinet — Unit cabinet will be constructed of galvanized steel, bonder-
ized, and coated with a powder coat paint.
— All units constructed with louver coil protection and corner post.
Louver can be removed by removing one fastener per louver panel.
AIR-COOLED, SPLIT-SYSTEM HEAT PUMP RP14 1-1/2 TO 5 NOMINAL TONS
Fans — Condenser fan will be direct-drive propeller type, discharging
air upward.
— Condenser fan motors will be totally enclosed, 1-phase type
with class B insulation and permanently lubricated bearings.
Shafts will be corrosion resistant. — Fan blades will be statically and dynamically balanced. — Condenser fan openings will be equipped with coated steel
wire safety guards. Compressor
— Compressor will be hermetically sealed. — Compressor will be mounted on rubber vibration isolators. Condenser Coil
— Condenser coil will be air cooled. — Coil will be constructed of aluminum fins mechanically bonded
to copper tubes. Refrigeration Components
— Refrigeration circuit components will include liquid-line shutoff
valve with sweat connections, vapor-line shutoff valve with
sweat connections, system charge of R-410A refrigerant, and
compressor oil. — Unit will be equipped with filter drier for R-410A refrigerant for
field installation.
Operating Characteristics
— The capacity of the unit will meet or exceed _____ Btuh at a
suction temperature of _____ °F/°C. The power consumption
at full load will not exceed _____ kW. — Combination of the unit and the evaporator or fan coil unit will
have a total net cooling capacity of _____ Btuh or greater at
conditions of _____ CFM entering air temperature at the evap-
orator at _____ °F/°C wet bulb and _____ °F/°C dry bulb, and
air entering the unit at _____ °F/°C. — The system will have a SEER of _____ Btuh/watt or greater at
DOE conditions.
Electrical Requirements
— Nominal unit electrical characteristics will be _____ v, single
phase, 60 hz. The unit will be capable of satisfactory operation
within voltage limits of _____ v to _____ v. — Nominal unit electrical characteristics will be _____ v, three
phase, 60 hz. The unit will be capable of satisfactory operation
within voltage limits of _____ v to _____ v. — Unit electrical power will be single point connection. — Control circuit will be 24v.
Special Features
— Refer to section of this literature identifying accessories and
descriptions for specific features and available enhancements.
Page 20
Air
Limited Warranty
RP14 Series
20
GENERAL TERMS OF LIMITED WARRANTY*
Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
*For complete details of the Limited and Conditional Warranties, including
applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
Conditional Parts
(Registration Required)...............................Ten (10) Years
Page 21
Air
Notes
RA14 Series
21
Page 22
Air
Notes
RA14 Series
22
Page 23
23
Air
Notes
RA14 Series
Page 24
The new degree of comfort.
Rheem Heating, Cooling & Water Heating • P.O. Box 17010
Fort Smith, Arkansas 72917 • www.rheem.com
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
PRINTED IN U.S.A. 3/15 QG FORM NO. P11-806 REV. 2