Rheem ROLA-115E Submittal Sheet

Page 1
SUBMITTAL COVER SHEET
Quantity
Unit Designation
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES: NOTES:
PRINTED IN U.S.A 01/12 QG FORM NO. M11-1640
PROJECT NAME
LOCATION
ARCHITECT
ENGINEER
CONTRACTOR
SUBMITTED BY DATE
UNIT SUMMARY
Page 2
FORM NO. X33-1357 REV. 1
JOB NAME MODEL NO.
CONTRACTOR OUTDOOR UNIT MODEL NO.
ENGINEER LOCATION
SUBMITTED FOR APPROVAL RECORD ORDER NO.
DATE
SUBMITTAL SHEET FOR HIGHBOY & LOWBOY OIL FURNACES WITH ECM/VARIABLE SPEED MOTORS
ROCA-***E: Highboy Series ROLA-***E: Lowboy Series Input Ratio from 84,000 to 175,000 BTU/HR [24.61 to 51.28 kW]
UNIT DATA
HEATING PERFORMANCE
TOTAL CAPACITY INPUT* ......
_______
MBH [kW]
TOTAL CAPACITY OUTPUT* ..
_______
MBH [kW]
DESIGN TEMP. RISE ..............
_______
°F [°C] DB
AFUE ................................................
_______
%
CALIFORNIA SEASONAL
EFFICIENCY ..................................
_______
%
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT......................................
_______
IWG
BLOWER SPEED ..........................
_______
RPM
POWER OUTPUT REQUIREMENT ..
_______
BHP
MOTOR RATING ........................
_______
HP [W]
POWER INPUT REQUIREMENT ........
_______
kW
ELECTRICAL DATA
POWER SUPPLY ..............................
_______ Hz
TOTAL UNIT AMPACITY................
_______
AMPS
MINIMUM WIRE SIZE ....................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ..........
_______
AMPS
FEATURES FOR ROCA/ROLA
The Rheem
Classic Series
®
premium upflow oil furnace is for installa-
tion in proper ventilated utility rooms, closets or alcoves.
ECM blower assemblies for heating and air conditioning applications
ECM Control board located in furnace vestibule
ECM controls set for 2-stage air conditioning, 2-stage heat pump
back up
10-gauge primary and 14-gauge secondary heat exchanger
Front cleanout ports extend through front wall for accessibility
Efficiencies up to 85.9%
Front or rear flue Lowboys available
All furnaces have standard Honeywell controls
Available with Beckett, Riello Carlin burners
Extended vestibule on all units
ENER UIDE
Annual Fuel Utilization Efficiency -
THIS MODEL
80.0%
MID
82% 88%
HIGH
AFUE
97%78%
Page 3
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
Rheem Sales Company, Inc. P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Manufacturer reserves the right to make changes without notice.”
PRINTED IN U.S.A. 2-13 QG FORM NO. X33-1357 REV. 1
Supersedes Form No. X33-1299
Lowboy
* Specify front or rear flue on Lowboy models
[ ] Designates Metric Conversions
DIMENSIONS
DIMENSIONS
Highboy
Model
Cabinet Width (B) 20-1/4" 25-1/8" Cabinet Depth (C) 47-1/2" 53-5/8" 33-1/8" 38" Centerline - Flue to Floor (D) 31-1/4" 38-1/2" 49-1/8" 52-5/8" Centerline - Flue to Side (E) 10-1/8" 12-1/2" 11-1/8" 12-3/4" Warm Air Supply Depth (G) 17-1/2" 21-1/2" 19-3/4" 23-3/8" Warm Air Supply Width (Ho) 18-1/4" 22-7/8" 20-1/2" 23-3/4" Return Air Supply Width (Hr) 18-1/4" 22-7/8" 15" 15" Return Air Supply Depth (J) 14" 13-5/8" 23-5/8" 23-5/8" Shipping Weight 323 lbs. 362 lbs. 298 lbs. 347 lbs.
ROLA-070E ROLA-115E
Lowboy*
ROCA-070E
DIMENSIONS
53-5/8"Cabinet Height (A) 40" 46" 56-1/2" 22-1/4" 25-1/2"
Highboy
ROCA-115E
Loading...