Rheem 3805 Series, RHP270-3805, RHP340-3805 Owner's Manual And Installation Instructions

Owner’s Guide
and
Installation Instructions
Rheem Heat Pump Water Heater
270,340 Models
This water heater must be installed and serviced by a qualified person.
Please leave this guide with the householder.
P a g e | 1
Dear Homeowner:
Thank you for selecting the Rheem residential heat pump water heater.
NOTE: For continual safe operation of this water heater it must be installed, operated and maintained in accordance with these instructions. This manual provides instruction regarding both installation and operation. After installation is completed please ensure the manual is given to the end-user for future reference.
This water heater is designed for use in a single family domestic dwelling for the purpose of heating potable water.
The main features of the water heater include: automatic operation whilst power and water supplies available; simultaneous delivery of hot water to multiple outlets; automated temperature control to maintain tank temperature to constant level; inclusion of a number of safety protections such as thermostat, over temperature cut-off device, temperature/pressure relief valve and earth protective device (these devices must not be tampered with or removed. The water heater must not be operated unless each of these devices is fitted and is in working order).
P a g e | 2
Table of Contents
PRECAUTIONS .................................................................................................................................................. 4
SPECIFICATIONS ............................................................................................................................................... 6
DIMENSIONS .................................................................................................................................................... 8
INSTALLATION ................................................................................................................................................. 9
PLUMBING CONNECTION ............................................................................................................................... 10
MATERIAL SPECIFICATIONS ...................................................................................................................................... 10
CONNECTION SIZES ................................................................................................................................................ 10
PIPE SIZING .......................................................................................................................................................... 10
WATER CONNECTIONS ........................................................................................................................................... 11
HOT WATER DELIVERY ........................................................................................................................................... 11
TEMPERATURE & PRESSURE RELIEF VALVE ................................................................................................................. 11
EXPANSION CONTROL VALVE (ECV) ......................................................................................................................... 12
RELIEF VALVE DRAIN .............................................................................................................................................. 12
CONDENSATION DRAIN .......................................................................................................................................... 13
REDUCING HEAT LOSSES ......................................................................................................................................... 13
WATER SUPPLIED BY STORAGE TANK ON THE ROOF ....................................................................................................... 13
ELECTRICAL CONNECTION .............................................................................................................................. 14
OPERATION AND USAGE ................................................................................................................................ 15
TO FILL AND TURN ON THE WATER HEATER .............................................................................................................. 15
REMOTE CONTROLLER ............................................................................................................................................ 15
TO TURN OFF THE WATER HEATER ................................................................................................................ 17
DRAINING THE WATER HEATER ..................................................................................................................... 18
WATER QUALITY ............................................................................................................................................ 18
ANODE INSPECTION AND REPLACEMENT ..................................................................................................................... 18
SATURATION INDEX: .............................................................................................................................................. 19
MAINTENANCE .............................................................................................................................................. 19
MINOR SIX MONTH MAINTENANCE ........................................................................................................................... 19
MAJOR FIVE YEAR SERVICE....................................................................................................................................... 20
HEAT PUMP SYSTEM .............................................................................................................................................. 20
TROUBLESHOOTING....................................................................................................................................... 21
P a g e | 3
FAILURE AND SOLUTION ......................................................................................................................................... 21
CONTROL PANEL ................................................................................................................................................... 21
USING HOT WATER ............................................................................................................................................... 22
WIRING DIAGRAM ......................................................................................................................................... 24
WARRANTY .................................................................................................................................................... 25
1. HEAT PUMP WATER HEATER MODEL ........................................................... ERROR! BOOKMARK NOT DEFINED.
2. TERMS OF THE SOLAHART WARRANTY AND EXCLUSIONS TO IT .................. ERROR! BOOKMARK NOT DEFINED.
3. WHAT IS COVERED BY THE SOLAHART WARRANTY ................................................................................. 25
P a g e | 4
Precautions
Please read these precautions carefully, failure to follow these instructions may damage your Heat Pump water heater or endanger the safety of persons and property in the vicinity of the water heater.
This water heater is only intended to be operated by persons who have the experience or the knowledge and the capabilities to do so. This water heater is not intended to be operated by persons with reduced physical, sensory or mental capabilities i.e. the infirm, or by children. Children should be supervised to ensure they do not interfere with the water heater.
The water heater must be directly connected to a 220 V AC (±10%) mains power supply. The water heater must be on its own circuit with an isolating switch installed at the switchboard. A secondary isolating switch may be installed within reach of the water heater.
The removal of the access cover(s) will expose 220 Volt wiring. They must only be removed
by a qualified technician.
This water heater can deliver water at temperatures which can cause scalding. Check the water temperature before use, such as when entering a shower or filling a bath or basin, to ensure it will not cause scald injury.
We recommend and it may also be required by regulations that an approved temperature
limiting device be fitted. This will ensure the water temperature does not exceed 50°C and the risk of scald injury will be reduced.
Do not use aerosols, stain removers and household chemicals near the water heater whilst
it is working. Gases from some aerosol sprays, stain removers and household chemicals are corrosive to the materials used in the heat pump system.
Do not store swimming pool chemicals, household cleaners, etc near the water heater. Ensure the air inlet and outlet louvres are not obstructed in any way at any time. Do not lean
any objects against water heater and ensure all trees and shrubbery are well clear of air intakes and exhaust.
Discharge of water from relief valve and condensate drain is normal during heat pump
operation therefore provision must be made to drain this water away. A suitable floor drain that enables water to be drained away to a safe location must be installed near the storage tank location. The continual presence of moisture around base of heater will lead to premature failure.
The water heater is suitable for both indoor and outdoor installation. Take care to ensure all
electrical components are protected from effects of humidity and rain.
The power supply to the water heater must not be switched on until the water heater is
filled with water.
Do not attempt to install, repair or remove the water heater, all work must be carried out by
a qualified technician.
P a g e | 5
Do not attempt to insert any foreign object (e.g. hand, screwdriver, stick) into the air inlet or
outlet of the outdoor unit. Rotating fan blades may cause injury.
If the water heater begins to operate abnormally (e.g. excessive noise, emit smoke, peculiar
smell, etc) stop operation of the equipment, isolate power supply promptly and contact the Service Department. Do not attempt to repair the unit.
Operate the easing lever on the temperature & pressure relief valve at least once every 6
months. It is very important you raise and lower the lever gently.
o Ensure that the drain line is clear and free of any obstructions and discharge water
can freely flow from drain line. If water does not discharge please contact Service Department immediately.
Specifications
Model
RHP270-3805
RHP340-3805
Power Supply
220V50Hz
Circuit Fuse - Model Number
50T T16AL250V
Circuit Fuse - Parameters
16A/250V
Rated heating volume*
3250 W
HP heating rated input Power (watts)
900
Current (amps)
4.1
Auxiliary heating input Power (watts)
2400
Current (amps)
10.9
Power (watts)
3800
Current (amps)
17.3
Rated Hot water output (litres/hr)
70
Water temperature setting (oC)
3065 (Preset 55)
Suitable ambient temperature (oC)
-743
Refrigerant quantity
R134a (1.35 Kg)
Water Side
Heat exchanger type
Copper Pipe coiled outside the tank
Tank capacity (L)
270
340
Cold/ hot water connection
RP ¾” / 20
relief valve connection
RP ¾” / 20
Maximum Pressure (MPa)
0.85
Air Side Heat exchanger type
Female fitting hydrophilic aluminium foil
Air outlet
Side Exhaust
Storage Tank
Diameter (mm)
ø648
Height (mm)
1815
2125
Net weight (kg)
115
130
*Working conditions: Dry bulb temperature: 20oC, Wet bulb Temperature: 15oC,
Tank water inlet: 15oC, tank water outlet: 55oC.
Maximum Input
P a g e | 6
P a g e | 7
Loading...