Rheem RGVH User Manual

Page 1
RGVH
Parts List
19-August-2015
This parts list is current as of the above revision date.
See http://www.rheempartslists.net/92-42800-RGVH.pdf for the current revision.
80% Gas Furnaces
Page 2
Model Explanation.... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . ... Page 3
Parts Numbers
Panels - Miscellaneous ... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... .... Page 4
Electrical Group . ..... ..... ..... ..... ..... .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... ..... ..... ... Page 5
Blower Group... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... ..... ..... .... Page 6
Heat Exchanger-Burner Group.... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... . Page 7
Gas Controls ... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... .... Page 8
Orifice Selection Chart.... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... ..... .... Page 9
Drawings/Photographs
Exploded View .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... Page 10
Blower Assembly ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... ..... ..... .. Page 11
Heat Exchanger Assembly.... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... .... Page 12
Notes/Disclaimer . ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . . Page 13
Page 2 of 13
19-August-2015
92-42800-RGVH
Page 3
MODEL NUMBER EXPLANATION
R G V H - 0 7 E A U E R 1 2 3 4 5 6 7 8 9
(1) MODEL DESIGNATION (6) VARIATIONS A = Standard Cabinet (2) MODEL B = Wide Cabinet G = Gas Furnace (7) BLOWER DESIGNATION (3) TYPE U = 11 X 6 V = Horizontal M = 11 X 7 R = 11 X 10 (4) DESIGN SERIES (8) AIRFLOW (5) HEATING CAPACITY (INPUT) E = 1100 - 1300 CFM 05 = 50,000 BTU/HR G = 1500-1700 CFM 07 = 75,000 BTU/HR J = 1900-2100 CFM 10 = 100,000 BTU/HR 12 = 125,000 BTU/HR (9) FUEL DESIGNATION 15 = 150,000 BTU/HR A = Canadian - Natural Gas R = U.S. - Natural Gas E = Electric Ignition (HSI) N = Electric Ignition (HSI) with NOX
SERIAL NUMBER EXPLANATION
C Y 5 D 3 0 7 F 5 9 1 0 0 0 0
1 2 3 4 5 6 7 8 9 10 (1) GAS CODE (6) MOTOR HORSEPOWER (2) LIMIT CONTROL (7) PLANT
F = Fort Smth, AR (3) BLOWER (8) WEEK (4) HEATING ELEMENT (9) YEAR (5) SPECIAL AREA REQUIREMENT (10) PRODUCTION NUMBER
Page 3 of 13
19-August-2015
92-42800-RGVH
Page 4
MODEL
No. Notes
1 Jacket AS-61690-06 AS-61690-06 AS-61690-08 AS-61690-07 AS-61690-08 2 Top Plate AE-61657-01 AE-61657-01 AE-61657-02 AE-61657-02 AE-61657-02 3 Blower/Filter Door AE-61679-01 AE-61679-01 AE-61680-01 AE-61680-01 AE-61680-01 4 Burner Door (w/o Plug Button) AE-61675-01 AE-61675-01 AE-61676-01 AE-61676-01 AE-61676-01
Plug Button - 1-3/16 in opening (2) 45-22980-01 45-22980-01 45-22980-01 45-22980-01 45-22980-01
5 Control Box (w/o Components) 68-22857-01 68-22857-01 68-22857-01 68-22857-01 68-22857-01
Control Box Cover AE-61699-02 AE-61699-02 AE-61699-02 AE-61699-02 AE-61699-02
Silicone Tubing - Pressure Switch 79-21491-93 79-21491-93 79-21491-93 79-21491-93 79-21491-93 13 Integrated Furnace Control Board (IFC) See Gas Controls 14 Pressure Switch See Electrical Group 15 Door Switch - Push Button See Electrical Group 16 Limit - Main Limit (Heat Exchanger Panel) See Electrical Group 17 Limit - Manual Reset (Burner Compartment) See Electrical Group 18 Transformer See Electrical Group 19 Capacitor - Blower Motor See Blower Group 20 Induced Draft Blower w/Gasket See Electrical Group 26 Gas Valve See Gas Controls 28 Limit - Heat Assisted (Blower Housing) See Electrical Group
No. Notes
1 Jacket AS-61690-07 AS-61690-09 AS-61690-10 AS-61690-10 2 Top Plate AE-61657-02 AE-61657-03 AE-61657-04 AE-61657-04 3 Blower/Filter Door AE-61680-03 AE-61681-01 AE-61682-01 AE-61682-01 4 Burner Door (w/o Plug Button) AE-61676-03 AE-61677-01 AE-61678-01 AE-61678-01
Plug Button - 1-3/16 in opening (2) 45-22980-01 45-22980-01 45-22980-01 45-22980-01
5 Control Box w/o Components 68-22857-01 68-22857-01 68-22857-01 68-22857-01
Control Box Cover AE-61699-02 AE-61699-02 AE-61699-02 AE-61699-02
Silicone Tubing - Pressure Switch 79-21491-93 79-21491-93 79-21491-83 79-21491-83 13 Integrated Furnace Control Board (IFC) See Gas Controls 14 Pressure Switch See Electrical Group 15 Door Switch - Push Button See Electrical Group 16 Limit - Main Limit (Heat Exchanger Panel) See Electrical Group 17 Limit - Manual Reset (Burner Compartment) See Electrical Group 18 Transformer See Electrical Group 19 Capacitor - Blower Motor See Blower Group 20 Induced Draft Blower w/Gasket See Electrical Group 26 Gas Valve See Gas Controls 28 Limit - Heat Assisted (Blower Housing) See Electrical Group
HEATING CAPACITY VARIATION BLOWER DESIGNATION
PANELS, MISCELLANEOUS PARTS
MODEL HEATING CAPACITY VARIATION BLOWER DESIGNATION
PANELS, MISCELLANEOUS PARTS
RGVH-
04
A U
RGVH-
10
A M
RGVH-
05
A U
RGVH-
10
B R
RGVH-
06
A U
RGVH-
12
A R
RGVH-
07
A M
RGVH-
15
A R
RGVH-
07
A U
Page 4 of 13
19-August-2015
92-42800-RGVH
Page 5
MODEL
No. Notes
12 Bracket (Limit - Manual Reset) (2) AE-61600-02 AE-61600-02 AE-61600-02 AE-61600-02 AE-61600-02 13 Integrated Furnace Control Board (IFC) See Gas Controls 14 Stk Pressure Switch 42-24064-03 42-22682-02 42-24064-03 42-22682-03 42-22682-03 15 Door Switch - Push Button 42-22692-01 42-22692-01 42-22692-01 42-22692-01 42-22692-01 16 Stk Limit - Main Limit (Heat Exchanger Panel) 47-22679-01 47-22679-03 47-22679-02 47-22679-01 47-22679-02 17 Stk Limit - Manual Reset (Burner Compartment) (2) 47-22861-01 47-22861-01 47-22861-01 47-22861-01 47-22861-01 18 Stk Transformer 46-22863-01 46-22863-01 46-22863-01 46-22863-01 46-22863-01 19 Capacitor - Blower Motor See Blower Group 20 Stk Induced Draft Blower w/Gasket 70-24071-01 70-22838-02 70-24071-02 70-22838-02 70-22838-02 28 Stk Limit - Heat Assisted (Blower Housing) 47-22860-01 47-22860-01 47-22860-01 47-22860-01 47-22860-01
Gasket - Induced Draft Blower 68-22850-01 68-22850-01 68-22850-01 68-22850-01 68-22850-01
Wiring Harness - 9 pin from IFC Board to 9 pin - Before F3094 AS-61702-06 AS-61702-06 AS-61702-06 AS-61702-06 AS-61702-06
Wiring Harness - 9 pin from IFC Board to 9 pin - After F3094 AS-61702-09 AS-61702-09 AS-61702-09 AS-61702-09 AS-61702-09
Wiring Harness - 9 pin to 7 terminals - BeforeF3094 AS-61706-08 AS-61706-08 AS-61706-08 AS-61706-08 AS-61706-08
Wiring Harness - 9 pin to 8 terminals - After F3094 AS-61706-11 AS-61706-11 AS-61706-11 AS-61706-11 AS-61706-11
Wiring Harness - 6 pin from IFC Board to 4 pin AS-61703-01 AS-61703-01 AS-61703-01 AS-61703-01 AS-61703-01
Wiring Harness - 4 pin to 2 pin and 3 terminals - Before F3094 N/A AS-61707-01 AS-61707-01 AS-61707-01 AS-61707-01
Wiring Harness - 4 pin to 2 pin and 2 terminals - After F3094 N/A AS-61707-09 AS-61707-09 AS-61707-09 AS-61707-09
Wiring Harness - 4 pin to 2 pin, 2 pin, 1 terminal - Before F3094 AS-61707-06 N/A N/A N/A N/A
Wiring Harness - 4 pin to 2 pin, 2 Pin - After F3094 AS-61707-08 N/A N/A N/A N/A
No. Notes
12 Bracket (Limit - Manual Reset) (2) AE-61600-02 AE-61600-02 AE-61600-02 AE-61600-02 13 Integrated Furnace Control Board (IFC) See Gas Controls 14 Stk Pressure Switch 42-22682-03 42-22682-03 42-22682-02 42-22682-02 15 Door Switch - Push Button 42-22692-01 42-22692-01 42-22692-01 42-22692-01 16 Stk Limit - Main Limit (Heat Exchanger Panel) 47-22679-02 47-22679-02 47-22679-03 47-22679-03 17 Stk Limit - Manual Reset (Burner Compartment) (2) 47-22861-01 47-22861-01 47-22861-01 47-22861-01 18 Stk Transformer 46-22863-01 46-22863-01 46-22863-01 46-22863-01 19 Capacitor - Blower Motor See Blower Group 20 Stk Induced Draft Blower w/Gasket 70-22838-02 70-22838-02 70-22838-02 70-22838-02 28 Stk Limit - Heat Assisted (Blower Housing) 47-22860-03 47-22860-01 47-22860-03 47-22860-04
Gasket - Induced Draft Blower 68-22850-01 68-22850-01 68-22850-01 68-22850-01
Wiring Harness - 9 pin from IFC Board to 9 pin - Before F3094 AS-61702-06 AS-61702-06 AS-61702-06 AS-61702-06
Wiring Harness - 9 pin from IFC Board to 9 pin - After F3094 AS-61702-09 AS-61702-09 AS-61702-09 AS-61702-09
Wiring Harness - 9 pin to 7 terminals - BeforeF3094 AS-61706-08 AS-61706-08 AS-61706-08 AS-61706-08
Wiring Harness - 9 pin to 8 terminals - After F3094 AS-61706-11 AS-61706-11 AS-61706-11 AS-61706-11
Wiring Harness - 6 pin from IFC Board to 4 pin AS-61703-01 AS-61703-01 AS-61703-01 AS-61703-01
Wiring Harness - 4 pin to 2 pin and 3 terminals - Before F3094 AS-61707-01 AS-61707-01 AS-61707-01 AS-61707-01
Wiring Harness - 4 pin to 2 pin and 2 terminals - After F3094 AS-61707-09 AS-61707-09 AS-61707-09 AS-61707-09
HEATING CAPACITY VARIATION BLOWER DESIGNATION
ELECTRICAL GROUP
MODEL HEATING CAPACITY VARIATION BLOWER DESIGNATION
ELECTRICAL GROUP
RGVH-
04
A U
RGVH-
10
A M
RGVH-
05
A U
RGVH-
10
B R
RGVH-
06
A U
RGVH-
12
A R
RGVH-
07
A M
RGVH-
15
A R
RGVH-
07
A U
Page 5 of 13
19-August-2015
92-42800-RGVH
Page 6
MODEL
No. Notes
21 Stk Blower Assembly (Includes items 19, 22-25) AS-61697-46 AS-61697-47 AS-61697-48 AS-61697-55 AS-61697-48 19 Stk Capacitor - Blower Motor 43-100509-43 43-100509-42 43-100509-42 43-100509-43 43-100509-42 22 Housing AS-61674-19 AS-61674-20 AS-61674-20 AS-61674-21 AS-61674-20 23 Motor Mounting Legs (4) AE-61698-02 AE-61698-02 AE-61698-02 AE-61698-02 AE-61698-02
Motor Mounting Leg Screws (8) 63-24368-01 63-24368-01 63-24368-01 63-24368-01 63-24368-01 24 Stk Blower Motor 51-24070-01 51-22873-01 51-24070-02 51-25023-01 51-24070-02 25 Stk Blower Wheel 70-22683-01 70-22683-01 70-22683-01 70-23111-05 70-22683-01
Capacitor Strap N/A AE-50892-01 N/A AE-50892-01 AE-50892-01
No. Notes
21 Stk Blower Assembly (Includes items 19, 22-25) AS-61697-50 AS-61697-52 AS-61697-52 AS-61697-52 19 Stk Capacitor - Blower Motor 43-100509-42 43-100509-43 43-100509-43 43-100509-43 22 Housing AS-61674-21 AS-61674-22 AS-61674-22 AS-61674-22 23 Motor Mounting Legs (4) AE-61698-02 AE-61698-02 AE-61698-02 AE-61698-02
Motor Mounting Leg Screws (8) 63-24368-01 63-24368-01 63-24368-01 63-24368-01 24 Stk Blower Motor 51-24070-02 51-25023-01 51-25023-01 51-25023-01 25 Stk Blower Wheel 70-22688-01 70-20602-01 70-20602-01 70-20602-01
Capacitor Strap N/A AE-50892-01 AE-50892-01 AE-50892-01
HEATING CAPACITY VARIATION BLOWER DESIGNATION
BLOWER GROUP
MODEL HEATING CAPACITY VARIATION BLOWER DESIGNATION
BLOWER GROUP
RGVH-
04
A U
RGVH-
10
A M
RGVH-
05
A U
RGVH-
10
B R
RGVH-
06
A U
RGVH-
12
A R
RGVH-
07
A M
RGVH-
15
A R
RGVH-
07
A U
Page 6 of 13
19-August-2015
92-42800-RGVH
Page 7
MODEL
No. Notes
6 Stk Heat Exchanger Assembly AS-61579-01 AS-61579-01 AS-61579-08 AS-61579-02 AS-61579-02
Heat Exchanger Bracket (2) AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02
7 Stk BurnerTubew/Shield
8 NOX Burner lnsert 9 NOX Burner Retainer Rod AE-61715-01 AE-61715-01 AE-61715-02 AE-61715-02 AE-61715-02
Burner Support (Holds Burner between the Burner Support Brackets) AE-61577-01 AE-61577-01 AE-61577-02 AE-61577-02 AE-61577-02 10 Burner Support Bracket(2) AE-61588-01 AE-61588-01 AE-61588-01 AE-61588-01 AE-61588-01 11 Stk Manifold (w/o Orifices) 81-23492-01 81-23492-01 81-23492-02 81-23492-02 81-23492-02
Burner Orifice - Natural Gas See Orifice Selection Chart
Burner Orifice - LP See Orifice Selection Chart
Number of Orifices (2) (2) (3) (3) (3)
No. Notes
6 Stk Heat Exchanger Assembly AS-61579-07 AS-61579-04 AS-61579-05 AS-61579-06
Heat Exchanger Bracket (2) AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02
7 Stk BurnerTubew/Shield
8 NOX Burner lnsert 9 NOX Burner Retainer Rod AE-61715-03 AE-61715-04 AE-61715-05 AE-61715-06
Burner Support (Holds Burner between the Burner Support Brackets) AE-61577-03 AE-61577-03 AE-61577-04 AE-61577-05 10 Burner Support Bracket(2) AE-61588-01 AE-61588-01 AE-61588-01 AE-61588-01 11 Stk Manifold (w/o Orifices) 81-23492-03 81-23492-03 81-23492-04 81-23492-05
Burner Orifice - Natural Gas See Orifice Selection Chart
Burner Orifice - LP See Orifice Selection Chart
Number of Orifices (4) (4) (5) (6)
HEATING CAPACITY VARIATION BLOWER DESIGNATION
HEAT EXCHANGER, BURNER / MANIFOLD
MODEL HEATING CAPACITY VARIATION BLOWER DESIGNATION
HEAT EXCHANGER, BURNER / MANIFOLD
RGVH-
04
A U
75-22840-02
(2)
AS-61714-01
(2)
RGVH-
10
A M
75-22840-02
(4)
AS-61714-01
(4)
RGVH-
05
A U
75-22840-02
(2)
AS-61714-01
(2)
RGVH-
10
B R
75-22840-02
(4)
AS-61714-01
(4)
RGVH-
06
A U
75-22840-02
(3)
AS-61714-01
(3)
RGVH-
12
A R
75-22840-02
(5)
AS-61714-01
(5)
RGVH-
07
A M
75-22840-02
(3)
AS-61714-01
(3)
RGVH-
15
A R
75-22840-02
(6)
AS-61714-01
(6)
RGVH-
07
A U
75-22840-02
(3)
AS-61714-01
(3)
Page 7 of 13
19-August-2015
92-42800-RGVH
Page 8
No. Notes
26 Stk GasValve - Natural Gas 60-22525-11 60-22525-11 26 Stk,1 GasValve- LP See Note 1 See Note 1 13 Stk Integrated Furnace Control Board (IFC) 62-22737-07 62-22694-01
Stk Flame Sensor 62-23543-01 62-23543-01 27 Stk Ignitor 62-22868-02 62-22868-02
Ignitor Bracket AE-61581-01 AE-61581-01
Ignitor Shield AE-61627-01 AE-61627-01
LP Conversion Kit:
Stk U.S. Models FP-15 FP-15 Stk Canadian Models FP-04 FP-04
No. Notes
26 Stk GasValve - Natural Gas 60-105055-01 60-105055-01 60-105055-01 60-105055-01 60-105055-01 26 Stk,1 GasValve- LP See Note 1 See Note 1 See Note 1 See Note 1 See Note 1 13 Stk Integrated Furnace Control Board (IFC) 62-22694-02 62-22694-03 62-22737-08 62-22737-10 62-22694-11
Stk Flame Sensor 62-23543-01 62-23543-01 62-23543-01 62-23543-01 62-23543-01 27 Stk Ignitor 62-22868-02 62-22868-02 62-22868-02 62-22868-02 62-22868-02
Ignitor Bracket AE-61581-01 AE-61581-01 AE-61581-01 AE-61581-01 AE-61581-01
Ignitor Shield AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01
LP Conversion Kit:
Stk U.S. Models FP-15 FP-15 FP-15 FP-15 FP-15 Stk Canadian Models FP-15 FP-15 FP-15 FP-15 FP-15
No. Notes
26 Stk GasValve - Natural Gas 60-105055-01 60-105055-01 60-22526-01 26 Stk,1 GasValve- LP See Note 1 See Note 1 See Note 2 13 Stk Integrated Furnace Control Board (IFC) 62-24044-01 62-24084-02 62-24202-01
Stk Flame Sensor 62-23543-01 62-23543-01 N/A 27 Stk Ignitor 62-22868-02 62-22868-02 N/A
Ignitor Bracket AE-61581-01 AE-61581-01 N/A
Ignitor Shield AE-61627-01 AE-61627-01 N/A
Pilot Assembly N/A N/A 62-24203-01
Pilot Shield N/A N/A AE-61757-01
Pilot Bracket N/A N/A AE-61658-02
LP Conversion Kit:
Stk U.S. Models FP-15 FP-15 EP-89H Stk Canadian Models FP-15 FP-15 N/A
No. Notes
26 Stk GasValve - Natural Gas 60-23490-01 60-23490-01 60-23490-01 60-23490-01 60-24290-01 60-24290-01 26 Stk,1 GasValve- LP See Note 1 See Note 1 See Note 1 See Note 1 See Note 1 See Note 1 13 Stk Integrated Furnace Control Board (IFC) 62-22737-08 62-22694-11 62-24084-02 62-24044-01 62-24044-01 62-24084-02
Stk Flame Sensor 62-23543-01 62-23543-01 62-23543-01 62-23543-01 62-23543-01 62-23543-01 27 Stk Ignitor 62-22868-02 62-22868-02 62-22868-02 62-22868-02 62-22868-02 62-22868-02
Ignitor Bracket AE-61581-01 AE-61581-01 AE-61581-01 AE-61581-01 AE-61581-01 AE-61581-01
Ignitor Shield AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01
LP Conversion Kit:
Stk U.S. Models FP-15 FP-15 FP-15 FP-15 FP-15 FP-15 Stk Canadian Models FP-04 FP-04 FP-04 FP-04 FP-04 FP-04
MODEL GAS CODE (TYPE)
MODEL GAS CODE (TYPE)
MODEL GAS CODE (TYPE)
MODEL GAS CODE (TYPE)
RGVH
BT
(HSI)
GAS CONTROLS - ROBERTSHAW
RGVH
CE
(HSI)
GAS CONTROLS - HONEYWELL
RGVH
DC
(HSI)
GAS CONTROLS - HONEYWELL
RGVH
DA
(HSI)
GAS CONTROLS -WHITE RODGERS
RGVH
CA
(HSI)
RGVH
CV
(HSI)
RGVH
DF
(HSI)
RGVH
DB
(HSI)
RGVH
CW
(HSI)
RGVH
DJ
(IP)
RGVH
DG
(HSI)
RGVH
CX
(HSI)
RGVH
DH
(HSI)
RGVH
CY
(HSI)
RGVH
EU
(HSI)
RGVH
EV
(HSI)
Page 8 of 13
19-August-2015
92-42800-RGVH
Page 9
CAUTION: Selection of the correct Natural Gas Orifice requires the following information for the specific installation:
1) Altitude in of the installation (ft.).
2) Average energy content of the Natural Gas fuel from the local supplier (BTU/cu. ft.). For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-59 and the latest edition of the National Fuel Gas Code Handbook, or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1. CAUTION:This information is provided for replacement purposes only. Conversion for operation at High Altitude must be done using the kit specified on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is based on 25,000 BTU/HR per burner. NOTE: Factory installed orifices are calculated and sized based on a Natural Gas heating value of 1075 BTU/cu. ft. and an elevation of 0 - 3000 ft. Elevation (ft.)
EnergyValue
(BTU/cu. ft.)
850 62-22175-38 62-22175-39 62-22175-40 62-22175-41 62-22175-41 62-22175-42 62-22175-42 62-22175-43 900 62-22175-40 62-22175-41 62-22175-42 62-22175-42 62-22175-42 62-22175-43 62-22175-43 62-22175-44
975 62-22175-41 62-22175-42 62-22175-42 62-22175-42 62-22175-43 62-22175-43 62-22175-44 62-22175-44 1075 62-22175-42 62-22175-42 62-22175-43 62-22175-43 62-22175-43 62-22175-44 62-22175-44 62-22175-45 1170 62-22175-43 62-22175-44 62-22175-44 62-22175-44 62-22175-45 62-22175-45 62-22175-46 62-22175-47
CAUTION: Selection of the correct LP Orifice requires the altitude of the specific installation (ft.). For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-59 and the latest edition of the National Fuel Gas Code Handbook (NFG), or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1. CAUTION:This information is provided for replacement purposes only. Conversion to LP or for operation at High Altitude should be done using the kit(s) specified on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is based on 25,000 BTU/HR per burner. Also, the chart is developed using the specified pressure setting of 10 in. water column instead of the 11.0 in water column used by the NFG and CANB149.1. NOTE: Orifices supplied in the LP Conversion Kit are calculated and sized based on an altitude of 0 - 4000 ft.
Elevation (ft.) Orifice
0 - 2000 62-22175-54 2001 - 3000 62-22175-54 3001 - 4000 62-22175-54 4001 - 5000 62-22175-54 5001 - 6000 62-22175-54 6001 - 7000 62-22175-54 7001 - 8000 62-22175-55 8001 - 9000 62-22175-55
9001 - 10000 62-22175-55
0 - 1999 2000 - 2999 3000 - 3999 4000 - 4999 5000 - 5999 6000 - 6999 7000 - 7999 8000 - 8999
80% GAS FURNACE - ORIFICE SELECTION CHART - NATURAL GAS
80% GAS FURNACE - ORIFICE SELECTION CHART - LP
Page 9 of 13
19-August-2015
92-42800-RGVH
Page 10
Exploded View
Page 10 of 13
19-August-2015
92-42800-RGVH
Page 11
Blower Assembly
Page 11 of 13
19-August-2015
92-42800-RGVH
Page 12
Heat Exchanger Assembly
Page 12 of 13
19-August-2015
92-42800-RGVH
Page 13
NOTES
Stk It is recommended that stock be maintained for this part.
N/A Not Applicable
1 Order Gas Valve for Natural Gas along with LP Conversion Kit. (If the original valve has been replaced, order the spring kit for the
replacement valve.)
2 Order specified LP Conversion Kit
DISCLAIMER: This document is intended to provide general replacement parts information to aid qualified service personnel in the repair of these models. The complete Model and Serial Number of the unit under repair should be specified when selecting and ordering replacement parts. Specifications and illustrations are subject to change without notice. Document 92-42800-RGVH supersedes all previous parts lists for these models. See http://www.rheempartslists.net/92-42800-RGVH for the latest revision of this document. The manufacturer assumes no obligation for errors or omissions. Service personnel must verify the proper and safe operation of equipment after the replacement of any original components.
P.O. Box 17010
Fort Smith, AR 72917-7010
Loading...