Rheem RGPJ User Manual

Page 1
RGPJ
Parts List
03-January-2017
This parts list is current as of the above revision date.
See http://www.rheempartslists.net/92-42800-RGPJ.pdf for the current revision.
80% Gas Furnaces
Page 2
Model Explanation.... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . ... Page 3
Parts Numbers
Panels - Miscellaneous ... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... .... Page 4
Electrical Group . ..... ..... ..... ..... ..... .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... ..... ..... ... Page 5
Blower Group... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... ..... ..... .... Page 6
Heat Exchanger-Burner Group.... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... . Page 7
Gas Controls ... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... .... Page 8
Orifice Selection Chart.... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... ..... .... Page 9
Drawings/Photographs
Exploded View .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... Page 10
Blower Assembly ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... ..... ..... .. Page 11
Burner Assembly ... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... .... Page12
NOX Insert Assembly After F0299 .... ..... ..... ..... .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... . .... . Page 13
Notes/Disclaimer . ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . . Page 14
Page 2 of 14
03-January-2017
92-42800-RGPJ
Page 3
R G P J - 0 7 E A U E R 1 2 3 4 5 6 7 8 9
(1) TRADEBRAND IDENTIFICATION (6) VARIATIONS A = Standard Cabinet (2) MODEL B = Wide Cabinet G = Gas Furnace (7) BLOWER DESIGNATION (3) TYPE M = 11 X 7 P = Upflow Non-condensing R = 11 X 10 U = 11 X 6 (4) DESIGN SERIES (8) AIRFLOW (5) HEATING INPUT DESIGNATION E = 1100-1300 CFM 05 = 50,000 BTU/HR G = 1500-1700 CFM 07 - 75,000 BTU/HR J = 1800-2100 CFM 10 = 100,000 BTU/HR 12 = 125,000 BTU/HR (9) FUEL DESIGNATION 15 = 150,000 BTU/HR R = Natural Gas
E = Electric N = Electric w/NOX
G E 5 D 7 0 7 F 3 1 9 5 9 9 9 9
1 2 3 4 5 6 7 8 9 10
(1) GAS CODE (6) MOTOR HORSEPOWER (2) LIMIT CONTROL (7) PLANT
F'= Fort Smith, AR (3) BLOWER (8) WEEK (4) HEATING ELEMENT (9) YEAR (5) SPECIAL AREA REQUIREMENT (10) PRODUCTION NUMBER
MODEL NUMBER EXPLANATION
SERIAL NUMBER EXPLANATION
Page 3 of 14
03-January-2017
92-42800-RGPJ
Page 4
MODEL
No. Notes
1 PlugButton 45-22980-01 45-22980-01 45-22980-01 45-22980-01 45-22980-01 2 Burner Compartment Door AE-61675-01 AE-61676-01 AE-61676-01 AE-61676-01 AE-61677-01 3 Blower/Filter Door AE-61679-01 AS-67894-01 AS-67894-01 AS-67894-01 AS-67895-01 4 DoorSwitch - Push Button 42-22692-01 42-22692-01 42-22692-01 42-22692-01 42-22692-01 5 Junction Box AE-61475-02 AE-61475-02 AE-61475-02 AE-61475-02 AE-61475-02 6 Junction Box Cover AE-61476-02 AE-61476-02 AE-61476-02 AE-61476-02 AE-61476-02 7 InducedDraft Blower See Electrical Group 8 Blower Assembly See Blower Group
9 Jacket AS-61690-17 AS-61690-18 AS-61690-19 AS-61690-18 AS-61690-20 10 Heat Exchanger Bracket See Heat Exchanger Group 11 Heat Exchanger See Heat Exchanger Group 12 TopPlate AE-61657-01 AE-61657-02 AE-61657-02 AE-61657-02 AE-61657-03 13 Limit - Main Limit (Heat Exchanger Panel) See Electrical Group 14 Silicone Tubing - Pressure Switch AE-61737-07 AE-61737-04 AE-61737-04 AE-61737-04 AE-61737-23 15 Pressure Switch See Electrical Group 16 Rollout Switch Bracket AE-61600-02 AE-61600-02 AE-61600-02 AE-61600-02 AE-61600-02 17 Limit - Manual Reset (Burner Compartment) See Electrical Group 24 Control Mounting Plate AE-67877-01 AE-67877-01 AE-67877-01 AE-67877-01 AE-67877-01 26 Control Box Cover AE-61699-02 AE-61699-02 AE-61699-02 AE-61699-02 AE-61699-02 27 Control Box 68-22857-01 68-22857-01 68-22857-01 68-22857-01 68-22857-01
Touch-up Paint - Platinum (Aerosol) 523012 523012 523012 523012 523012 Touch-up Paint - Platinum (Paint Pen) 523013 523013 523013 523013 523013 Touch-up Paint - Green (Aerosol) 52-18662-48 52-18662-48 52-18662-48 52-18662-48 52-18662-48 Touch-up Paint - Green (Paint Pen) 523010 523010 523010 523010 523010
No. Notes
1 PlugButton 45-22980-01 45-22980-01 45-22980-01 45-22980-01 45-22980-01
2 Burner Compartment Door AE-61677-01 AE-61678-01 AE-61678-01 AE-61678-01 AE-61678-01
3 Blower/Filter Door AS-67895-01 AS-67896-01 AS-67896-01 AS-67896-01 AS-67896-01
4 DoorSwitch - Push Button 42-22692-01 42-22692-01 42-22692-01 42-22692-01 42-22692-01
5 Junction Box AE-61475-02 AE-61475-02 AE-61475-02 AE-61475-02 AE-61475-02
6 Junction Box Cover AE-61476-02 AE-61476-02 AE-61476-02 AE-61476-02 AE-61476-02
7 InducedDraft Blower See Electrical Group
8 Blower Assembly See Blower Group
9 Jacket AS-61690-20 AS-61690-26 AS-61690-26 AS-61690-26 AS-61690-26 10 Heat Exchanger Bracket See Heat Exchanger Group 11 Heat Exchanger See Heat Exchanger Group 12 TopPlate AE-61657-03 AE-61657-04 AE-61657-04 AE-61657-04 AE-61657-04 13 Limit - Main Limit (Heat Exchanger Panel) See Electrical Group 14 Silicone Tubing - Pressure Switch AE-61737-23 AE-61737-15 AE-61737-15 AE-61737-15 AE-61737-15 15 Pressure Switch See Electrical Group 16 Rollout Switch Bracket AE-61600-02 AE-61600-02 AE-61600-02 AE-61600-02 AE-61600-02 17 Limit - Manual Reset (Burner Compartment) See Electrical Group 24 Control Mounting Plate AE-67877-01 AE-67877-01 AE-67877-01 AE-67877-01 AE-67877-01 26 Control Box Cover AE-61699-02 AE-61699-02 AE-61699-02 AE-61699-02 AE-61699-02 27 Control Box 68-22857-01 68-22857-01 68-22857-01 68-22857-01 68-22857-01
Touch-up Paint - Platinum (Aerosol) 523012 523012 523012 523012 523012 Touch-up Paint - Platinum (Paint Pen) 523013 523013 523013 523013 523013 Touch-up Paint - Platinum (Aerosol) 523012 523012 523012 523012 523012 Touch-up Paint - Green (Paint Pen) 523010 523010 523010 523010 523010
HEATING CAPACITY VARIATION BLOWER DESIGNATION AIRFLOW
PANELS, SHEET METAL, MISCELLANEOUS
MODEL HEATING CAPACITY VARIATION BLOWER DESIGNATION AIRFLOW
PANELS, SHEET METAL, MISCELLANEOUS
RGPJ
05
A U E
RGPJ
10
B R J
RGPJ
07
A M G
RGPJ
12
A R G
RGPJ
07
A U E
RGPJ
12
A R J
RGPJ
10
A M E
RGPJ
15
A R G
RGPJ
10
B R G
RGPJ
15
A R J
Page 4 of 14
03-January-2017
92-42800-RGPJ
Page 5
MODEL
No. Notes
7 Stk Induced Draft Blower w/Gasket 70-101087-01 70-101087-01 70-101087-01 70-101087-01 70-101087-01 13 Stk Limit - Main Limit (Heat Exchanger Panel) 47-25349-03 47-25349-01 47-25349-02 47-25349-02 47-25349-01 15 Stk Pressure Switch 42-24194-01 42-24194-01 42-24194-01 42-24194-01 42-24194-01 17 Stk Limit - Manual Reset (Burner Compartment) (3) 47-22861-01 47-22861-01 47-22861-01 47-22861-01 47-22861-01 23 Stk Limit - Heat Assisted (Blower Housing) 47-22860-01 47-22860-01 47-22860-01 47-22860-03 47-22860-01 25 Integrated Furnace Control Board (IFC) See Gas Controls 28 Stk Transformer 46-24124-03 46-24124-03 46-24124-03 46-24124-03 46-24124-03
Transformer Fuse (Small - 9/16 in.) 46-22863-82 46-22863-82 46-22863-82 46-22863-82 46-22863-82 Transformer Fuse (Large - 1-9/16 in.) 46-22863-84 46-22863-84 46-22863-84 46-22863-84 46-22863-84 Wiring Harness - 6 pin to 4 pin, 4 wires 45-24371-05 45-24371-05 45-24371-05 45-24371-05 45-24371-05
Wiring Harness - 9 pin from board to 9 pin 45-24371-04 45-24371-04 45-24371-04 45-24371-04 45-24371-04
No. Notes
7 Stk Induced Draft Blower w/Gasket 70-101087-01 70-101087-01 70-101087-01 70-101087-01 70-101087-01 13 Stk Limit - Main Limit (Heat Exchanger Panel) 47-25349-01 47-25349-03 47-25349-03 47-25349-03 47-25349-03 15 Stk Pressure Switch 42-24194-01 42-24194-01 42-24194-01 42-24194-01 42-24194-01 17 Stk Limit - Manual Reset (Burner Compartment) (3) 47-22861-01 47-22861-01 47-22861-01 47-22861-01 47-22861-01 23 Stk Limit - Heat Assisted (Blower Housing) 47-22860-01 47-22860-03 47-22860-03 47-22860-04 47-22860-04 25 Integrated Furnace Control Board (IFC) See Gas Controls 28 Stk Transformer w/Fuse 46-24124-03 46-24124-03 46-24124-03 46-24124-03 46-24124-03
Transformer Fuse (Small - 9/16 in.) 46-22863-82 46-22863-82 46-22863-82 46-22863-82 46-22863-82 Transformer Fuse (Large - 1-9/16 in.) 46-22863-84 46-22863-84 46-22863-84 46-22863-84 46-22863-84 Wiring Harness - 6 pin to 4 pin, 4 wires 45-24371-05 45-24371-05 45-24371-05 45-24371-05 45-24371-05
Wiring Harness - 9 pin from board to 9 pin 45-24371-04 45-24371-04 45-24371-04 45-24371-04 45-24371-04
HEATING CAPACITY VARIATION BLOWER DESIGNATION AIRFLOW
Wiring Harness - 4 pin to 2 pin and 2 straight terminals, 4 wires
Wiring Harness - 9 pin to 8 terminals (5 insulated/1 straight/2 flag), 8 wires
MODEL HEATING CAPACITY VARIATION BLOWER DESIGNATION AIRFLOW
Wiring Harness - 4 pin to 2 pin and 2 straight terminals, 4 wires
Wiring Harness - 9 pin to 8 terminals (5 insulated/1 straight/2 flag), 8 wires
RGPJ
05
A U E
ELECTRIC GROUP
45-24371-17 45-24371-17 45-24371-17 45-24371-17 45-24371-17
45-24371-13 45-24371-13 45-24371-13 45-24371-13 45-24371-13
RGPJ
10
B R J
ELECTRIC GROUP
45-24371-17 45-24371-17 45-24371-17 45-24371-17 45-24371-17
45-24371-13 45-24371-13 45-24371-13 45-24371-13 45-24371-13
RGPJ
07
A M G
RGPJ
12
A
R G
RGPJ
07
A U E
RGPJ
12
A R J
RGPJ
10
A
M
E
RGPJ
15
A R
G
RGPJ
10
B R G
RGPJ
15
A R
J
Page 5 of 14
03-January-2017
92-42800-RGPJ
Page 6
MODEL
No. Notes
8 Stk Blower Assembly (Includes items 18-22) AS-61697-47 AS-61697-66 AS-61697-79 AS-61697-80 AS-61697-67 18 Stk Blower Wheel 70-22683-01 70-23111-05 70-22683-01 70-22688-01 70-20602-01 19 Housing AS-61674-20 AS-61674-21 AS-61674-20 AS-61674-21 AS-61674-22 20 Stk Blower Motor 51-22873-01 51-24272-01 51-22858-01 51-22858-01 51-24272-01 21 Motor Mount (4) AE-61698-02 AE-61698-02 AE-61698-02 AE-61698-02 AE-61698-02 22 Stk Capacitor - Blower Motor 43-100509-42 43-100509-43 43-100509-42 43-100509-42 43-21298-43 23 Limit - Heat Assisted (Blower Housing) See Electrical Group
No. Notes
8 Stk Blower Assembly (Includes items 18-22) AS-61697-74 AS-61697-67 AS-61697-74 AS-61697-67 AS-61697-74 18 Stk Blower Wheel 70-20602-01 70-20602-01 70-20602-01 70-20602-01 70-20602-01 19 Housing AS-61674-22 AS-61674-22 AS-61674-22 AS-61674-22 AS-61674-22 20 Stk Blower Motor 51-25327-01 51-24272-01 51-25327-01 51-24272-01 51-25327-01 21 Motor Mount (4) AE-61698-02 AE-61698-02 AE-61698-02 AE-61698-02 AE-61698-02 22 Stk Capacitor - Blower Motor 43-21298-43 43-21298-43 43-21298-43 43-21298-43 43-21298-43 23 Limit - Heat Assisted (Blower Housing) See Electrical Group
HEATING CAPACITY VARIATION BLOWER DESIGNATION AIRFLOW
MODEL HEATING CAPACITY VARIATION BLOWER DESIGNATION AIRFLOW
RGPJ
05
A U E
BLOWER GROUP
RGPJ
10
B R J
BLOWER GROUP
RGPJ
07
A M G
RGPJ
12
A
R G
RGPJ
07
A U E
RGPJ
12
A R J
RGPJ
10
A
M
E
RGPJ
15
A R
G
RGPJ
10
B R G
RGPJ
15
A R J
Page 6 of 14
03-January-2017
92-42800-RGPJ
Page 7
MODEL
No. Notes
10 Heat Exchanger Bracket AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02 11 Stk Heat Exchanger Assembly AS-61579-09 AS-100560-01 AS-100560-01 AS-61579-07 AS-61579-04 13 Limit - Main Limit (Heat Exchanger Panel) See Electrical Group 17 Limit - Manual Reset (Burner Compartment) (3) See Electrical Group 23 Limit - Heat Assisted (Blower Housing) See Electrical Group
29 NOX Burner Insert - BeforeF0299 34 NOX Burner Retainer Rod - Before F0299 AE-61715-01 AE-61715-01 AE-61715-01 AE-61715-01 N/A 29 NOX Insert Assembly - After F0299 34 NOX Insert Retainer - After F0299 AE-67872-01 AE-67872-02 AE-67872-02 AE-67872-03 N/A
30 Burner Support Bracket (2) - BeforeF0597 AE-61588-01 AE-61588-01 AE-61588-01 AE-61588-01 AE-61588-01 30 Burner Support Bracket (2) - After F0597 AE-61588-02 AE-61588-02 AE-61588-02 AE-61588-02 AE-61588-02
Burner Support - BeforeF0597 AE-61577-01 AE-61577-02 AE-61577-02 AE-61577-03 AE-61577-03 Burner Support - After F0597 AE-60997-01 AE-60997-02 AE-60997-02 AE-60997-03 AE-60997-03
31 Stk Manifold (w/o Orifices) 81-102427-01 81-102427-02 81-102427-02 81-102427-03 81-102427-03 32 Stk Burner w/Shield - Before F0597 32 Stk Burner Assembly - After F0597 AS-60993-02 AS-60993-03 AS-60993-03 AS-60993-04 AS-60993-04
Burner Orifice - Natural Gas See Orifice Selection Chart Burner Orifice - LP See Orifice Selection Chart Number of Orifices (2) (3) (3) (4) (4)
No. Notes
10 Heat Exchanger Bracket AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02 11 Stk Heat Exchanger Assembly AS-61579-04 AS-61579-05 AS-61579-05 AS-61579-06 AS-61579-06 13 Limit - Main Limit (Heat Exchanger Panel) See Electrical Group 17 Limit - Manual Reset (Burner Compartment) (3) See Electrical Group 23 Limit - Heat Assisted (Blower Housing) See Electrical Group
29 NOX Burner Insert - BeforeF0299 34 NOX Burner Retainer Rod - Before F0299 AE-61715-01 AE-61715-01 AE-61715-01 N/A AE-61715-01 29 NOX Insert Assembly - After F0299 34 NOX Insert Retainer - After F0299 AE-67872-03 AE-67872-04 AE-67872-04 N/A AE-67872-05
30 Burner Support Bracket (2) - BeforeF0597 AE-61588-01 AE-61588-01 AE-61588-01 AE-61588-01 AE-61588-01 30 Burner Support Bracket (2) - After F0597 AE-61588-02 AE-61588-02 AE-61588-02 AE-61588-02 AE-61588-02
Burner Support - BeforeF0597 AE-61577-03 AE-61577-04 AE-61577-04 AE-61577-05 AE-61577-05 Burner Support - After F0597 AE-60997-03 AE-60997-04 AE-60997-04 AE-60997-05 AE-60997-05
31 Stk Manifold (w/o Orifices) 81-102427-03 81-102427-04 81-102427-04 81-102427-05 81-102427-05 32 Stk Burner w/Shield - Before F0597 32 Stk Burner Assembly - After F0597 AS-60993-04 AS-60993-05 AS-60993-05 AS-60993-06 AS-60993-06
Burner Orifice - Natural Gas See Orifice Selection Chart Burner Orifice - LP See Orifice Selection Chart Number of Orifices (4) (5) (5) (6) (6)
HEATING CAPACITY VARIATION BLOWER DESIGNATION AIRFLOW
HEAT EXCHANGER, BURNER / MANIFOLD GROUP
MODEL HEATING CAPACITY VARIATION BLOWER DESIGNATION AIRFLOW
HEAT EXCHANGER GROUP
RGPJ
05
A U E
AE-61771-01
(2)
AS-67875-01
(1)
75-22840-02
(2)
RGPJ
10
B R J
AE-61771-01
(4)
AS-67875-01
(3)
75-22840-02
(4)
RGPJ
07
A M G
AE-61771-01
(3)
AS-67875-01
(2)
75-22840-02
(3)
RGPJ
12
A R G
AE-61771-01
(5)
AS-67875-01
(4)
75-22840-02
(5)
RGPJ
07
A U E
AE-61771-01
(3)
AS-67875-01
(2)
75-22840-02
(3)
RGPJ
12
A R J
AE-61771-01
(5)
AS-67875-01
(4)
75-22840-02
(5)
RGPJ
10
A
M
E
AE-61771-01
(4)
AS-67875-01
(3)
75-22840-02
(4)
RGPJ
15
A R
G
N/A
N/A
75-22840-02
(6)
RGPJ
10
B R G
N/A
N/A
75-22840-02
(4)
RGPJ
15
A R
J
AE-61771-01
(6)
AS-67875-01
(5)
75-22840-02
(6)
Page 7 of 14
03-January-2017
92-42800-RGPJ
Page 8
No. Notes
25 Stk Integrated Furnace Control Board (IFC) 62-24268-01 62-24268-01 62-24044-01 62-24084-02 62-24268-01
Stk Flame Sensor 62-23543-01 62-23543-01 62-23543-01 62-23543-01 62-23543-01 33 Stk Gas Valve - Natural Gas 60-105055-01 60-23490-01 60-24290-01 60-24290-01 60-24350-01 33 Stk Gas Valve - LP See Note 1 SeeNote 1 See Note 1 SeeNote 1 See Note 1 35 Stk Ignitor 62-22868-02 62-22868-02 62-22868-02 62-22868-02 62-22868-02
Ignitor Bracket AE-61581-01 AE-61581-01 AE-61581-01 AE-61581-01 AE-61581-01
Ignitor Shield AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01
LP Conversion Kit:
Stk U.S. Models FP-15 FP-15 FP-15 FP-15 FP-15
Stk Canadian Models FP-15 FP-04 FP-04 FP-04 FP-04
No. Notes
25 Stk Integrated Furnace Control Board (IFC) 62-24192-01 62-24192-01 62-24268-02 62-24268-02 62-24268-02
Stk Flame Sensor 62-23543-01 92-21310-40 62-23543-01 62-23543-01 62-23543-01 33 Stk Gas Valve - Natural Gas 60-23490-01 60-105055-01 60-105055-01 60-24350-01 60-23490-01 33 Stk Gas Valve - LP See Note 1 SeeNote 1 See Note 1 SeeNote 1 See Note 1 35 Stk Ignitor 62-22868-02 62-22868-02 62-22868-02 62-22868-02 62-22868-02
Ignitor Bracket AE-61581-01 AE-61581-01 AE-61581-01 AE-61581-01 AE-61581-01
Ignitor Shield AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01 AE-61627-01
LP Conversion Kit:
Stk U.S. Models FP-15 FP-15 FP-15 FP-15 FP-15
Stk Canadian Models FP-04 FP-15 FP-15 FP-04 FP-04
No. Notes
25 Stk Integrated Furnace Control Board (IFC) 62-24268-02 62-24192-01
Stk Flame Sensor 62-23543-01 62-23543-01 33 Stk Gas Valve - Natural Gas 60-105055-01 60-105055-01 33 Stk Gas Valve - LP See Note 1 SeeNote 1 35 Stk Ignitor 62-22868-02 62-22868-02
Ignitor Bracket AE-61581-01 AE-61581-01
Ignitor Shield AE-61627-01 AE-61627-01
LP Conversion Kit:
Stk U.S. Models FP-15 FP-15
Stk Canadian Models FP-15 FP-15
MODEL GAS CODE (TYPE)
GAS CONTROLS
MODEL GAS CODE (TYPE)
GAS CONTROLS
MODEL GAS CODE (TYPE)
GAS CONTROLS
RGPJ
EB
(HSI)
RGPJ
FW
(HSI)
RGPJ
GE
(HSI)
RGPJ
EC
(HSI)
RGPJ
FX
(HSI)
RGPJ
GF
(HSI)
RGPJ
EU
(HSI)
RGPJ
GA
(HSI)
RGPJ
EV
(HSI)
RGPJ
GB
(HSI)
RGPJ
EZ
(HSI)
RGPJ
GC
(HSI)
Page 8 of 14
03-January-2017
92-42800-RGPJ
Page 9
CAUTION: Selection of the correct Natural Gas Orifice requires the following information for the specific installation:
1) Altitude in of the installation (ft.).
2) Average energy content of the Natural Gas fuel from the local supplier (BTU/cu. ft.). For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-59 and the latest edition of the National Fuel Gas Code Handbook, or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1. CAUTION:This information is provided for replacement purposes only. Conversion for operation at High Altitude must be done using the kit specified on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is based on 25,000 BTU/HR per burner. NOTE: Factory installed orifices are calculated and sized based on a Natural Gas heating value of 1075 BTU/cu. ft. and an elevation of 0 - 3000 ft. Elevation (ft.)
EnergyValue
(BTU/cu. ft.)
850 62-22175-38 62-22175-39 62-22175-40 62-22175-41 62-22175-41 62-22175-42 62-22175-42 62-22175-43 900 62-22175-40 62-22175-41 62-22175-42 62-22175-42 62-22175-42 62-22175-43 62-22175-43 62-22175-44
975 62-22175-41 62-22175-42 62-22175-42 62-22175-42 62-22175-43 62-22175-43 62-22175-44 62-22175-44 1075 62-22175-42 62-22175-42 62-22175-43 62-22175-43 62-22175-43 62-22175-44 62-22175-44 62-22175-45 1170 62-22175-43 62-22175-44 62-22175-44 62-22175-44 62-22175-45 62-22175-45 62-22175-46 62-22175-47
CAUTION: Selection of the correct LP Orifice requires the altitude of the specific installation (ft.). For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-59 and the latest edition of the National Fuel Gas Code Handbook (NFG), or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1. CAUTION:This information is provided for replacement purposes only. Conversion to LP or for operation at High Altitude should be done using the kit(s) specified on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is based on 25,000 BTU/HR per burner. Also, the chart is developed using the specified pressure setting of 10 in. water column instead of the 11.0 in water column used by the NFG and CANB149.1. NOTE: Orifices supplied in the LP Conversion Kit are calculated and sized based on an altitude of 0 - 4000 ft.
Elevation (ft.) Orifice
0 - 2000 62-22175-54 2001 - 3000 62-22175-54 3001 - 4000 62-22175-54 4001 - 5000 62-22175-54 5001 - 6000 62-22175-54 6001 - 7000 62-22175-54 7001 - 8000 62-22175-55 8001 - 9000 62-22175-55
9001 - 10000 62-22175-55
0 - 1999 2000 - 2999 3000 - 3999 4000 - 4999 5000 - 5999 6000 - 6999 7000 - 7999 8000 - 8999
80% GAS FURNACE - ORIFICE SELECTION CHART - NATURAL GAS
80% GAS FURNACE - ORIFICE SELECTION CHART - LP
Page 9 of 14
03-January-2017
92-42800-RGPJ
Page 10
Exploded View
Page 10 of 14
03-January-2017
92-42800-RGPJ
Page 11
Blower Assembly
Page 11 of 14
03-January-2017
92-42800-RGPJ
Page 12
Burner Assembly
Page 12 of 14
03-January-2017
92-42800-RGPJ
Page 13
NOX Insert Assembly After F0299
Page 13 of 14
03-January-2017
92-42800-RGPJ
Page 14
NOTES
Stk It is recommended that stock be maintained for this part.
N/A Not Applicable
1 Order Gas Valve for Natural Gas along with LP Conversion Kit. (If the original valve has been replaced, order the
spring kit for the replacement valve.)
DISCLAIMER: This document is intended to provide general replacement parts information to aid qualified service personnel in the repair of these models. The complete Model and Serial Number of the unit under repair should be specified when selecting and ordering replacement parts. Specifications and illustrations are subject to change without notice. Document 92-42800-RGPJ supersedes all previous parts lists for these models. See http://www.rheempartslists.net/92-42800-RGPJ for the latest revision of this document. The manufacturer assumes no obligation for errors or omissions. Service personnel must verify the proper and safe operation of equipment after the replacement of any original components.
P.O. Box 17010
Fort Smith, AR 72917-7010
Loading...