RGLQ
Parts List
07-December-2013
This parts list is current as of the above revision date.
See http://www.rheempartslists.net/92-42800-RGLQ.pdf for the current revision.
80% Gas Furnaces - 2 Stage
Table of Contents
Model Explanation.... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . ... Page 3
Parts Numbers
Panels - Miscellaneous ... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... .... Page 4
Electrical Group . ..... ..... ..... ..... ..... .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... ..... ..... ... Page 5
Blower Group... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... ..... ..... .... Page 6
Heat Exchanger-Burner Group.... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... . Page 7
Gas Controls ... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... .... Page 7
Orifice Selection Chart.... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... ..... .... Page 8
Drawings/Photographs
Exploded View .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... . Page 9
Blower Assembly ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . .... ..... ..... ..... .. Page 10
Burner Assembly ... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... .... Page11
Notes/Disclaimer . ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... .... . .... . .... . .... ..... ..... ..... ..... ..... .... . .... . . Page 12
Page 2 of 12
07-December-2013
92-42800-RGLQ
R G L Q - 0 7 E A M G R
(1) (2) (3) (4) (5) (6) (7) (8) (9)
(1) TRADEBRAND IDENTIFICATION (6) VARIATIONS
A = Standard Cabinet
(2) MODEL B = Wide Cabinet
G = Gas Furnace
(7) BLOWER DESIGNATION
(3) TYPE M = 11 X 7
L = Downflow R = 11 X 10
U = 11 X 6
(4) DESIGN SERIES /VARIATION
(8) AIRFLOW
(5) HEATING INPUT DESIGNATION E = 1100 - 1300 CFM
J = 1800-2100 CFM
05 = 50,000 BTU/HR
07 = 75,000 BTU/HR (9) FUEL DESIGNATION
10 = 100,000 BTU/HR R = Canadian and U.S. - Natural Gas
12 = 125,000 BTU/HR
15 = 150,000 BTU/HR
E = Electric Ignition
N = Electric Ignition with NOX
G Q 5 D 7 0 7 F 3 5 0 6 9 9 9 9
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
(1) GAS CODE (6) MOTOR HORSEPOWER
(2) LIMIT CONTROL (7) PLANT
F = Fort Smith, AR
(3) BLOWER
(8) WEEK
(4) HEATING ELEMENT
(9) YEAR
(5) SPECIAL AREA REQUIREMENT
(10) PRODUCTION NUMBER
F 0 8 1 3 9 9 9 9
(1) (2) (3) (4)
(1) PLANT CODE
(2) WEEK (DATE CODE)
(3) YEAR
(4) PRODUCTION NUMBER
Note: For Gas Code, see Control System Gas Code on Rating Plate
SERIAL NUMBER EXPLANATION (Units Produced before Nov. 2013)
SERIAL NUMBER EXPLANATION (Units Produced after Nov. 2013)
MODEL NUMBER EXPLANATION
Page 3 of 12
07-December-2013
92-42800-RGLQ
MODEL
No. Notes
1 3 Jacket (See Note 3) N/A N/A N/A N/A N/A N/A
2 Top Plate AE-66981-01 AE-66981-02 AE-66981-02 AE-66981-03 AE-66981-04 AE-66981-04
3 Blower/Filter Door (Neutra Green) AS-67893-01 AS-67894-01 AS-67894-01 AS-67895-01 AS-67896-01 AS-67896-01
3 Blower/Filter Door (Granite/Steel Gray) AS-67893-13 AS-67894-13 AS-67894-13 AS-67895-13 AS-67896-13 AS-67896-13
4 Burner Compartment Door (NeutraGreen) AS-101733-01 AS-101734-01 AS-101734-01 AS-101735-01 AS-101736-01 AS-101736-01
4
Plug Button - 1-3/16 in. opening (2) 45-22980-01 45-22980-01 45-22980-01 45-22980-01 45-22980-01 45-22980-01
Door Angle AE-66980-01 AE-66980-02 AE-66980-02 AE-66980-03 AE-66980-04 AE-66980-04
5 Mounting Control Plate AE-67877-01 AE-67877-01 AE-67877-01 AE-67877-01 AE-67877-01 AE-67877-01
6 Junction Box AE-61475-02 AE-61475-02 AE-61475-02 AE-61475-02 AE-61475-02 AE-61475-02
7 Junction Box Cover AE-61476-02 AE-61476-02 AE-61476-02 AE-61476-02 AE-61476-02 AE-61476-02
8 Flue Pipe AE-66691-14 AE-66691-14 AE-66691-14 AE-66691-14 AE-66691-14 AE-66691-14
9 Flue Pipe Enclosure AE-66982-01 AE-66982-01 AE-66982-01 AE-66982-01 AE-66982-01 AE-66982-01
10 Flue Pipe Enclosure Door AE-66983-01 AE-66983-01 AE-66983-01 AE-66983-01 AE-66983-01 AE-66983-01
11 Rear Baffle AE-66994-01 AE-66994-02 AE-66994-02 AE-66994-03 AE-66994-04 AE-66994-04
12 NOX Insert Retainer See Heat Exchanger Group
13 NOX Burner Inserts See Heat Exchanger Group
14 Pressure Switch See Electrical Group
15 Door Switch - Push Button See Electrical Group
16 Limit - Main Limit (Heat Exchanger Panel) See Electrical Group
17 Limit - Manual Reset (Burner Compartment) See Electrical Group
18 Limit - Heat Assisted (Blower Housing) See Electrical Group
19 Transformer See Electrical Group
20 Induced Draft Blower w/Gasket See Electrical Group
21 Blower Assembly See Blower Group
27 Heat Exchanger Assembly See Heat Exchanger Group
28 Heat Exchanger Bracket See Heat Exchanger Group
29 Filter (2) 54-22699-02 54-22699-01 54-22699-01 54-22699-01 54-22699-02 54-22699-02
30 Filter Rack AE-61711-01 AE-66681-01 AE-66681-01 AE-66681-01 AE-66681-01 AE-66681-01
37 Gas Valve See Gas Controls
38 Integrated Furnace Control Board (IFC) See Gas Controls
Touch-up Paint - Platinum (Aerosol) 523012 523012 523012 523012 523012 523012
Touch-up Paint - Platinum (PaintPens) 523013 523013 523013 523013 523013 523013
Touch-up Paint - Green (Aerosol) 52-18662-48 52-18662-48 52-18662-48 52-18662-48 52-18662-48 52-18662-48
Touch-up Paint - Green (PaintPens) 523010 523010 523010 523010 523010 523010
HEATING CAPACITY
VARIATION
BLOWER DESIGNATION
AIRFLOW
Burner Compartment Door (Granite/Steel
Gray)
Touch-up Paint - Granite/Steel Gray
(Aerosol)
Touch-up Paint - Granite/Steel Gray (Paint
Pens)
RGLQ
05
A
U
E
PANELS, SHEET METAL PARTS
AS-101733-11 AS-101734-11 AS-101734-11 AS-101735-11 AS-101736-11 AS-101736-11
PD523018 PD523018 PD523018 PD523018 PD523018 PD523018
PD523019 PD523019 PD523019 PD523019 PD523019 PD523019
RGLQ
07
A
M
E
RGLQ
10
A
M
E
RGLQ
10
B
R
J
RGLQ
12
A
R
J
RGLQ
15
A
R
J
Page 4 of 12
07-December-2013
92-42800-RGLQ
MODEL
No. Notes
14 Stk,2 Pressure Switch 42-102341-02 42-102341-02 42-102341-02 42-102341-02
15 Door Switch - Push Button 42-22692-01 42-22692-01 42-22692-01 42-22692-01
16 Stk Limit - Main Limit (Heat Exchanger Panel) 47-25349-15 47-25349-13 47-25349-05 47-25349-03
17 Stk Limit - Manual Reset (Burner Compartment) 47-22861-03 47-22861-03 47-22861-03 47-22861-03
18 Stk Limit - Heat Assisted (Blower Housing) 47-22860-06 47-22860-06 47-22860-06 47-22860-06
19 Stk Transformer w/Fuse - Before F1106 46-22863-04 46-22863-04 46-22863-04 46-22863-04
19 Stk Transformer w/Fuse - After F1106 46-101496-01 46-101496-01 46-101496-01 46-101496-01
20 Stk Induced Draft Blowerw/Gasket 70-101888-01 70-101888-01 70-101888-02 70-101888-02
Wiring Harness - 9 pin to (3 pin and 7 terminals) 45-24371-21 45-24371-21 45-24371-21 45-24371-21
Wiring Harness - 2 pin to twostraight terminals from board 45-24371-23 45-24371-23 45-24371-23 45-24371-23
Wiring Harness - 4 pin to (3 pin from IFC Board) 45-24371-26 45-24371-26 45-24371-26 45-24371-26
Wiring Harness - 9 pin to 12 pin from IFC Board (After F3407) 45-102668-01 45-102668-01 45-102668-01 45-102668-01
Wiring Harness - 9 pin to 12 pin from IFC Board (Before F3407) 45-24371-25 45-24371-25 45-24371-25 45-24371-25
Wiring Harness - 2 pin to (1 terminal and 1 strip back from Junction Box) 45-24371-37 45-24371-37 45-24371-37 45-24371-37
Wiring Harness - 4 pin from blower shelf to (4 pin to Induced Draft Motor) 45-24371-48 45-24371-48 N/A N/A
Wiring Harness - 4 pin from blower shelf to (5 pin to Induced Draft Motor) N/A N/A 45-24371-49 45-24371-49
No. Notes
14 Stk,2 Pressure Switch 42-102341-02 42-102341-02
15 Door Switch - Push Button 42-22692-01 42-22692-01
16 Stk Limit - Main Limit (Heat Exchanger Panel) 47-25349-17 47-25349-05
17 Stk Limit - Manual Reset (Burner Compartment) 47-22861-03 47-22861-03
18 Stk Limit - Heat Assisted (Blower Housing) 47-22860-06 47-22860-06
19 Stk Transformer w/Fuse - Before F1106 46-22863-04 46-22863-04
19 Stk Transformer w/Fuse - After F1106 46-101496-01 46-101496-01
20 Stk Induced Draft Blowerw/Gasket 70-101888-02 70-101888-02
Wiring Harness - 9 pin to (3 pin and 7 terminals) 45-24371-21 45-24371-21
Wiring Harness - 2 pin to twostraight terminals from board 45-24371-23 45-24371-23
Wiring Harness - 4 pin to (3 pin from IFC Board) 45-24371-26 45-24371-26
Wiring Harness - 9 pin to 12 pin from IFC Board (After F3407) 45-102668-01 45-102668-01
Wiring Harness - 9 pin to 12 pin from IFC Board (Before F3407) 45-24371-25 45-24371-25
Wiring Harness - 2 pin to (1 terminal and 1 strip back from Junction Box) 45-24371-37 45-24371-37
Wiring Harness - 4 pin from blower shelf to (5 pin to Induced Draft Motor) 45-24371-49 45-24371-49
HEATING CAPACITY
VARIATION
BLOWER DESIGNATION
AIRFLOW
ELECTRIC GROUP
MODEL
HEATING CAPACITY
VARIATION
BLOWER DESIGNATION
AIRFLOW
ELECTRIC GROUP
RGLQ
05
A
U
E
RGLQ
12
A
R
J
RGLQ
07
A
M
E
RGLQ
15
A
R
J
RGLQ
10
A
M
E
RGLQ
10
B
R
J
Page 5 of 12
07-December-2013
92-42800-RGLQ
MODEL
No. Notes
21 Stk Blower Assembly(Includes items 22-26) AS-61697-46 AS-61697-50 AS-61697-50 AS-61697-52
22 Housing AS-61674-19 AS-61674-21 AS-61674-21 AS-61674-22
23 Stk Blower Motor 51-24070-01 51-24070-02 51-24070-02 51-25023-01
24 Motor Mount Leg (4) AE-61698-02 AE-61698-02 AE-61698-02 AE-61698-02
25 Stk BlowerWheel 70-22683-01 70-22688-01 70-22688-01 70-20602-01
26 Stk Capacitor - BlowerMotor 43-100509-43 43-100509-42 43-100509-42 43-100509-43
No. Notes
21 Stk Blower Assembly(Includes items 22-26) AS-61697-52 AS-61697-31
22 Housing AS-61674-22 AS-61674-06
23 Stk Blower Motor 51-25023-01 51-25023-01
24 Motor Mount Leg (4) AE-61698-02 AE-61698-02
25 Stk BlowerWheel 70-20602-01 70-20602-01
26 Stk Capacitor - BlowerMotor 43-100509-43 43-100509-43
HEATING CAPACITY
VARIATION
BLOWER DESIGNATION
AIRFLOW
BLOWER GROUP
MODEL
HEATING CAPACITY
VARIATION
BLOWER DESIGNATION
AIRFLOW
BLOWER GROUP
RGLQ
05
A
U
E
RGLQ
12
A
R
J
RGLQ
07
A
M
E
RGLQ
15
A
R
J
RGLQ
10
A
M
E
RGLQ
10
B
R
J
Page 6 of 12
07-December-2013
92-42800-RGLQ
MODEL
No. Notes
12 NOX Insert Retainer AE-67872-01 AE-67872-02 AE-67872-03 AE-67872-03 AE-67872-04 AE-67872-05
13 NOX Burner Inserts
27 Stk Heat Exchanger AS-66997-23 AS-100561-01 AS-66997-07 AS-66997-04 AS-66997-05 AS-66997-06
28
32 Stk Burner Assembly AS-60993-02 AS-60993-03 AS-60993-04 AS-60993-04 AS-60993-05 AS-60993-06
33 Burner Support AE-60997-01 AE-60997-02 AE-60997-03 AE-60997-03 AE-60997-04 AE-60997-05
34 Burner Support Bracket (2) AE-61588-02 AE-61588-02 AE-61588-02 AE-61588-02 AE-61588-02 AE-61588-02
35 Stk Manifold (w/o Orifices) 81-101149-01 81-101149-02 81-101149-03 81-101149-03 81-101149-04 AS-61663-05
36 Burner Orifice - Natural Gas See Orifice Selection Chart
36 Burner Orifice - LP See Orifice Selection Chart
36 Number of Orifices (2) (3) (4) (4) (5) (6)
No. Notes
37 Stk Gas Valve - NaturalGas 60-23490-08 60-23490-12 60-101921-01 60-101921-01
37 Stk,1 Gas Valve - LP SeeNote 1 See Note 1 See Note 4 See Note 4
38
38 Stk
39 Stk Flame Sensor 62-23543-01 62-23543-01 62-23543-01 62-23543-01
40 Stk Direct Spark Ignitor 62-24164-01 62-24164-01 62-24164-01 62-24164-01
Direct Spark Ignitor Bracket AE-61885-02 AE-61885-02 AE-61885-02 AE-61885-02
LP Conversion Kit:
Stk U.S. Models FP-09 FP-09 FP-32 FP-32
Stk Canadian Models FP-10 FP-10 FP-32 FP-32
HEATING CAPACITY
VARIATION
BLOWER DESIGNATION
AIRFLOW
Heat Exchanger Bracket(2) Before F2608
Heat Exchanger Bracket- Left Side
- After F2608
Heat Exchanger Bracket- Right
Side - After F2608
MODEL
GAS CODE
Integrated Furnace Control Board
(IFC) Original
Integrated Furnace Control Board
(IFC) Replacement
RGLQ
05
A
U
E
HEAT EXCHANGER, BURNER / MANIFOLD
AS-67875-01
(1)
AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02
AE-102680-01 AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02
AE-102680-02 AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02 AE-67846-02
RGLQ
FJ
62-24320-02 62-24320-02 62-24320-02 62-102635-01
62-102635-81 62-102635-81 62-102635-81 62-102635-01
RGLQ
07
A
M
E
AS-67875-01
(2)
RGLQ
FQ
GAS CONTROLS
RGLQ
10
A
M
E
AS-67875-01
(3)
RGLQ
GQ
RGLQ
10
B
R
J
AS-67875-01
(3)
RGLQ
GW
RGLQ
12
A
R
J
AS-67875-01
(4)
RGLQ
15
A
R
J
AS-67875-01
(5)
Page 7 of 12
07-December-2013
92-42800-RGLQ
CAUTION: Selection of the correct Natural Gas Orifice requires the following information for the specific installation:
1) Altitude in of the installation (ft.).
2) Average energy content of the Natural Gas fuel from the local supplier (BTU/cu. ft.).
For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-59 and the latest edition of the
National Fuel Gas Code Handbook, or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1.
CAUTION:This information is provided for replacement purposes only. Conversion for operation at High Altitude must be done using the kit specified
on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is based on 25,000 BTU/HR per burner.
NOTE: Factory installed orifices are calculated and sized based on a Natural Gas heating value of 1075 BTU/cu. ft. and an elevation of 0 - 3000 ft.
Elevation (ft.)
EnergyValue
(BTU/cu. ft.)
850 62-22175-38 62-22175-39 62-22175-40 62-22175-41 62-22175-41 62-22175-42 62-22175-42 62-22175-43
900 62-22175-40 62-22175-41 62-22175-42 62-22175-42 62-22175-42 62-22175-43 62-22175-43 62-22175-44
975 62-22175-41 62-22175-42 62-22175-42 62-22175-42 62-22175-43 62-22175-43 62-22175-44 62-22175-44
1075 62-22175-42 62-22175-42 62-22175-43 62-22175-43 62-22175-43 62-22175-44 62-22175-44 62-22175-45
1170 62-22175-43 62-22175-44 62-22175-44 62-22175-44 62-22175-45 62-22175-45 62-22175-46 62-22175-47
CAUTION: Selection of the correct LP Orifice requires the altitude of the specific installation (ft.).
For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-59 and the latest edition of the
National Fuel Gas Code Handbook (NFG), or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1.
CAUTION:This information is provided for replacement purposes only. Conversion to LP or for operation at High Altitude should be done using the
kit(s) specified on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is based on 25,000 BTU/HR per burner. Also, the chart is developed using the specified pressure setting of 10 in. water column
instead of the 11.0 in water column used by the NFG and CANB149.1.
NOTE: Orifices supplied in the LP Conversion Kit are calculated and sized based on an altitude of 0 - 4000 ft.
Elevation (ft.) Orifice
0 - 2000 62-22175-54
2001 - 3000 62-22175-54
3001 - 4000 62-22175-54
4001 - 5000 62-22175-54
5001 - 6000 62-22175-54
6001 - 7000 62-22175-54
7001 - 8000 62-22175-55
8001 - 9000 62-22175-55
9001 - 10000 62-22175-55
0 - 1999 2000 - 2999 3000 - 3999 4000 - 4999 5000 - 5999 6000 - 6999 7000 - 7999 8000 - 8999
80% GAS FURNACE - ORIFICE SELECTION CHART - NATURAL GAS
80% GAS FURNACE - ORIFICE SELECTION CHART - LP
Page 8 of 12
07-December-2013
92-42800-RGLQ
Exploded View
Page 9 of 12
07-December-2013
92-42800-RGLQ
Blower Assembly
Page 10 of 12
07-December-2013
92-42800-RGLQ
Burner Assembly
Page 11 of 12
07-December-2013
92-42800-RGLQ
NOTES
Stk It is recommended that stock be maintained for this part.
N/A Not Applicable
1 Order the specified LP Conversion Kit.
2 The specified replacement pressure switch may have a different pressure setting than that originally supplied.
3 Jacket is not available for replacement.
4 Order Gas Valve for Natural Gas along with LP Conversion Kit.
DISCLAIMER: This document is intended to provide general replacement parts information to aid qualified
service personnel in the repair of these models. The complete Model and Serial Number of the unit under repair
should be specified when selecting and ordering replacement parts. Specifications and illustrations are subject
to change without notice. Document 92-42800-RGLQ supersedes all previous parts lists for these models. See
http://www.rheempartslists.net/92-42800-RGLQ for the latest revision of this document. The manufacturer
assumes no obligation for errors or omissions. Service personnel must verify the proper and safe operation of
equipment after the replacement of any original components.
P.O. Box 17010