1 Gasket - Front Base Angle68-102435-0168-102435-0168-102435-0268-102435-0268-102435-03
3Blower/Filter Door - Before F1399AS-61908-02AS-61908-02AS-61909-02AS-61909-02AS-61910-02
3Blower/Filter Door - After F1399AS-61908-03AS-61908-03AS-61909-03AS-61909-03AS-61910-03
5Burner Compartment DoorAS-61978-01AS-61978-01AS-61979-01AS-61979-01AS-61980-01
Thumbscrew and Insert Kit64-24081-8164-24081-8164-24081-8164-24081-8164-24081-81
7BaffleAE-61875-01AE-61875-01AE-61875-01AE-61875-01AE-61875-01
8BaffleAE-61875-02AE-61875-02AE-61875-02AE-61875-02AE-61875-02
9Rear BaffleAE-61878-01AE-61878-01AE-61878-02AE-61878-02AE-61878-03
10Junction BoxAE-61475-02AE-61475-02AE-61475-02AE-61475-02AE-61475-02
11Junction Box CoverAE-61476-02AE-61476-02AE-61476-02AE-61476-02AE-61476-02
12Control Mounting Plate - Before F1399AS-61969-01AS-61969-01AS-61969-01AS-61969-01AS-61969-01
12Control Mounting Plate - After F1399AE-67877-01AE-67877-01AE-67877-01AE-67877-01AE-67877-01
13Solid BottomAE-61874-02AE-61874-02AE-61874-03AE-61874-03AE-61874-04
14Door SwitchSee Electrical Group
15Limit - Main Limit (Heat Exchanger Panel)See Electrical Group
16Limit - Manual Reset (Burner Compartment)See Electrical Group
17High Pressure SwitchSee Electrical Group
18Low Pressure SwitchSee Electrical Group
19Induced Draft Blower w/GasketSee Electrical Group
45Outlet Air Pipe68-24021-0168-24021-0168-24021-0168-24021-0168-24021-01
46Outlet Air Pipe Gasket68-24022-0268-24022-0268-24022-0268-24022-0268-24022-02
47Connector/Transition68-24047-0768-24047-0768-24047-0868-24047-0868-24047-09
48Hose Clamp (2)64-22043-0264-22043-0264-22043-0264-22043-0264-22043-02
49Tubing - Santoprene (31.5 in.)79-25353-8279-25353-8279-25353-8279-25353-8279-25353-82
Grommet (5/8 in. ID)56-22521-0356-22521-0356-22521-0356-22521-0356-22521-03
62Filter - Plastic54-24094-0154-24094-0154-24094-0254-24094-0254-24094-03
63Filter Retainer Rod45-24095-0145-24095-0145-24095-0145-24095-0145-24095-01
64Filter Rod Support AngleAE-60520-01AE-60520-01AE-60520-01AE-60520-01AE-60520-01
65Filter Support AngleAE-61883-01AE-61883-01AE-61883-01AE-61883-01AE-61883-01
ECM Motor Mount (Belly Band)70-24104-0270-24104-0270-24104-0270-24104-0270-24104-02
27Motor Mount Bracket (4)AE-61956-01AE-61956-01AE-61956-01AE-61956-01AE-61956-01
28Stk Blower Wheel - Before F210170-24254-0270-24254-0270-23112-0170-23112-0170-24255-01
28Stk Blower Wheel - After F210170-24254-0270-24254-0270-24179-0170-24179-0170-23111-20
29Thermistor - Return Air SensorSee Electrical Group
32Stk Direct Spark Ignitor - Before F210062-24271-0162-24271-0162-24271-0162-24271-0162-24271-01
32Stk Direct Spark Ignitor - After F210062-24141-0462-24141-0462-24141-0462-24141-0462-24141-04
Direct Spark Ignitor Bracket - Before F0502AE-61885-01AE-61885-01AE-61885-01AE-61885-01AE-61885-01
Direct Spark Ignitor Bracket - After F0502AE-61885-02AE-61885-02AE-61885-02AE-61885-02AE-61885-02
33Stk Manifold (w/o Orifices) - Before F2100AS-61815-02AS-61815-03AS-61815-04AS-61815-05AS-61815-06
33Stk Manifold (w/o Orifices) - After F2100AS-61815-18AS-61815-19AS-61815-20AS-61815-21AS-61815-22
35Burner Support BracketAE-61808-01AE-61808-01AE-61808-01AE-61808-01AE-61808-01
36Burner Support Bracket - Before F2100AE-61808-02AE-61808-02AE-61808-02AE-61808-02AE-61808-02
36Burner Support Bracket - After F2100AE-61808-01AE-61808-01AE-61808-01AE-61808-01AE-61808-01
37Burner Support - Before F2100AE-61765-02AE-61765-03AE-61765-04AE-61765-05AE-61765-06
37Burner Support - After F2100AE-61809-12AE-61809-13AE-61809-14AE-61809-15AE-61809-16
38Burner Diffuser - BeforeF2100AE-61766-02AE-61766-03AE-61766-04AE-61766-05AE-61766-06
38Burner Diffuser - After F2100AE-61882-11AE-61882-07AE-61882-08AE-61882-09AE-61882-10
39Burner ShieldAE-61807-02AE-61807-03AE-61807-04AE-61807-05AE-61807-06
34Burner Orifice - Natural GasSee Orifice Selection Chart
34Burner Orifice - LPSee Orifice Selection Chart
Stk Spark Ignitor62-24141-0462-24141-0462-24141-04
44Ignitor Control Bracket - After F4300AE-67903-02AE-67903-02AE-67903-02
AIgnitor Control BracketTop - Before F4300AE-59313-01AE-59313-01AE-59313-01
BIgnitor Control Bracket Bottom - Before F4300AE-59097-01AE-59097-01AE-59097-01
Stk LP Conversion Kit - U.S. ModelsFP-07FP-07FP-07
Stk LP Conversion Kit - Canadian ModelsFP-08FP-08FP-08
CAUTION: Selection of the correct Natural Gas Orifice requires the following information for the specific installation:
1) Altitude in of the installation (ft.).
2) Average energy content of the Natural Gas fuel from the local supplier (BTU/cu. ft.).
For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-59 and the latest edition of the
National Fuel Gas Code Handbook, or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1.
CAUTION:This information is provided for replacement purposes only. Conversion for operation at High Altitude must be done using the kit specified
on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is based on 15,000 BTU/HR per burner.
NOTE: Factory installed orifices are calculated and sized based on a Natural Gas heating value of 1075 BTU/cu. ft. and an elevation of 0 - 2000 ft.
Elevation (ft.)
CAUTION: Selection of the correct LP Orifice requires the altitude of the specific installation (ft.).
For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-59 and the latest edition of the
National Fuel Gas Code Handbook (NFG), or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1.
CAUTION:This information is provided for replacement purposes only. Conversion to LP or for operation at High Altitude should be done using the
kit(s) specified on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is based on 15,000 BTU/HR per burner. Also, the chart is developed using the specified pressure setting of 10 in. water column
instead of the 11.0 in water column used by the NFG and CANB149.1.
NOTE: Orifices supplied in the LP Conversion Kit are calculated and sized based on an altitude of 0 - 2000 ft.
Elevation (ft.)Orifice
0 to 2000 ft.62-22175-91
2001 to 300062-22175-91
3001 to 400062-22175-90
4001 to 500062-22175-58
5001 to 600062-22175-59
6001 to 700062-22175-60
7001 to 800062-22175-62
8001 to 900062-22175-63
9001 to 100062-22175-64
90% GAS FURNACE - ORIFICE SELECTION CHART - NATURAL GAS
90% GAS FURNACE - ORIFICE SELECTION CHART - LP
Page 8 of 12
19-October-2016
92-42800-RGFD
Page 9
Exploded View
Page 9 of 12
19-October-2016
92-42800-RGFD
Page 10
Blower Assembly
Page 10 of 12
19-October-2016
92-42800-RGFD
Page 11
Burner Assembly
Page 11 of 12
19-October-2016
92-42800-RGFD
Page 12
NOTES
Stk It is recommended that stock be maintained for this part.
N/A Not Applicable
1 Newer units will have front base angle gaskets. Older units can be retrofitted with this gasket.
2 Order the specified LP Conversion Kit.
DISCLAIMER: This document is intended to provide general replacement parts information to aid qualified
service personnel in the repair of these models. The complete Model and Serial Number of the unit under repair
should be specified when selecting and ordering replacement parts. Specifications and illustrations are subject
to change without notice. Document 92-42800-RGFD supersedes all previous parts lists for these models. See
http://www.rheempartslists.net/92-42800-RGFD for the latest revision of this document. The manufacturer
assumes no obligation for errors or omissions. Service personnel must verify the proper and safe operation of
equipment after the replacement of any original components.
P.O. Box 17010
Fort Smith, AR 72917-7010
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.