INSTALLATION INSTRUCTIONS
FOR REPLACEMENT UNCASED COILS FOR
AIR HANDLERS:
(-)CSA: featuring R-22 Refrigerant
(-)CSL: featuring Industry Standard R-410A
RCSL: Refrigerant
▲WARNING
These instructions are intended as an aid to qualified licensed
service personnel for proper installation, adjustment and operation of this unit. Read these instructions thoroughly before
attempting installation or operation. Failure to follow these
instructions may result in improper installation, adjustment, service or maintenance possibly resulting in fire, electrical shock,
property damage, personal injury or death.
NOTE: Shown with Horizontal Drip Shield.
(Requires RXHH- Horizontal Adapter Kit.)
!
92-100105-07-04
SUPERSEDES 92-100105-07-03
FIGURE 1
MODEL NUMBER EXPLANATION
(-) CSA—HU 24 17 AU
AIR HANDLER COIL
U = UNCASED
DESIGN VARIATION
A = 1STDESIGN
C = 2NDDESIGN
T = TIN PLATED
T = COPPER HAIRPINS
COIL SIZE
17 = 17.5" [431.8mm]
21 = 21" [533.4 mm]
24 = 24.5" [609.6 mm]
NOMINAL CAPACITY #
36/24 = 18,000 TO 24,000 BTUH
36/38 = [5.27 to 7.03 kW]
36/38 = 30,000 TO 36,000 BTUH
36/38 = [8.79 to 10.55 kW]
36/48 = 42,000 TO 48,000 BTUH
36/38 = [12.31 to 14.06 kW]
36/60 = 60,000 BTUH
36/38 = [17.58 kW]
AIRFLOW DIRECTION*
HU = A/C or Heat Pump,
HU = Upflow, Downflow or Horizontal
REFRIGERANT
A = R-22
L = R-410A
S = PRODUCT GENERATION
CLASSIFICATION
C = COIL
TRADE BRAND
*All replacement coils for HM and AU air handler applications will be HU.
GENERAL
(-)CSA- and (-)CSL- are replacement only uncased
coils. (-)CSA- replacement coils are used only in
(-)HKA, (-)HLA and (-)HSA R-22 air handlers.
RCSL- replacement coils are used only in (-)HKL,
(-)HLL and (-)HSL R-410A air handlers.
For horizontal applications, a horizontal drip shield
must be installed to catch excess condensate
drainage. RCSA and RCSL replacement coils are
shipped without a horizontal drip shield. For a horizontal adapter kit, refer to Tables 1 and 2 for correct kit matchups.
!
▲WARNING
The drain pan that comes with the RCSA- or
RCSL- Uncased Air Handler Coil is not built
with a high-heat resistant material. Do NOT use
these coils with gas and oil fossil fuel furnaces,
or any other high-heat device. Failure to obey
this warning could result in serious equipment
damage, personal injury or death.
TABLE 1
R-22 UNCASED COILS: (-)CSA- ACCESSORY INFORMATION
Replacement
R-22 Uncased Coil
Model
R-22 Air Handler Model
(-)HSA-HM/AU
Original
(-)HLA-HM
Horizontal Adapter Kit
Model Number
(-)HKA-HM
(-)CSA-HU2417AU/TU 1817 and 2417 2417 2417 RXHH-A02
(-)CSA-HU3617AU/TU 3017 and 3617 3617 3617 RXHH-A03
(-)CSA-HU3621AU/TU 3621 3621 3621 RXHH-A03
(-)CSA-HU4821AU/TU 4221 and 4821 4821 4821 RXHH-A04
(-)CSA-HU4824AU/TU 4824 4824 4824 RXHH-A04
(-)CSA-HU6024AU/TU — 6024 6024 RXHH-A05
TABLE 2
R-410A UNCASED COILS: (-)CSL- ACCESSORY INFORMATION
Replacement
R-410A Uncased Coil
Model
R-410A Air Handler Model
(-)HSL-HM/AU
Original
(-)HLL-HM
Horizontal Adapter Kit
Model Number
(-)HKL-HM
(-)CSL-HU2417CU/TU 1817 and 2417 2417 2417 RXHH-A02
(-)CSL-HU3617CU/TU 3017 and 3617 3617 3617 RXHH-A03
(-)CSL-HU3621CU/TU 3621 3621 3621 RXHH-A03
(-)CSL-HU3821CU/TU — 3821 3821 RXHH-A04
(-)CSL-HU3824CU/TU — 3824 — RXHH-A04
(-)CSL-HU4821CU/TU 4221 and 4821 4821 4821 RXHH-A04
(-)CSL-HU4824CU/TU 4824 4824 4824 RXHH-A04
(-)CSL-HU6024CU/TU — 6024 6024 RXHH-A05