Rheem RASLJEC Specification

Rheem Prestige Series™Two-Stage Air Conditioners equipped with the Comfort Control
2
FORM NO. A11-211
RASL- JEC Series
Efficiencies up to 18 SEER/14 EER Nominal Sizes 2 to 5 Ton [7.03 to 17.6 kW] Cooling Capacities 25.8 to 57.2 [7.56 to 16.76 kW]
• Industry’s lowest profile design: 33" maximum height
• The Comfort Control
2
System™ provides over 32+ on-board
diagnostics and fault history codes for condensing units with single-phase compressors by detecting system and electrical problems. The integrated diagnostics with Active Protection™ prevents compressor operation when potentially harmful conditions are detected. Sends “Call for Service” alert notifi­cation to the thermostat to alert the homeowner of required service.
• Serial Communication Enhanced – When installed with a Serial Communicating Air Handler (RHPL/RHPN-HM****JC) and user interface control (RHC-TST501CMMS) Series 500 thermostat this unit offers 4 or 2 wire installation, auto­configuration, and diagnostic messaging with full communi­cating capability.
• Legacy Enabled – Unit can be conventionally wired using 24VAC with non-communicating Rheem Prestige air-handlers or furnaces with non-communicating thermostat.
• Features a 10-year conditional unit replacement warranty and 10-year parts warranty when properly installed with a new Rheem air handler or Rheem indoor coil with a Rheem gas furnace. See product warranty card for additional information.
• Reliable Two-Stage operation for precise temperature control with On-Demand dehumidification feature. When matched with ECM gas furnace or air-handler, the system adjusts air­flow to help control humidity for unsurpassed comfort in the cooling mode.
• All controls are accessible by removing one service panel. Removable top grille provides access to the condenser fan motor and condenser coil.
• Attractive, louvered wrap-around jacket protects the coil from yard hazards and weather extremes. Top grille is steel reinforced for extra strength. Cabinet is powder painted for all-weather protection.
• For quiet operation and improved efficiency, models feature an ECM two-speed condenser fan motor with a 3-blade outdoor fan.
• All models meet or exceed a 1000-hour salt spray test per ASTM B117 Standard Practice for Operating Salt Spray Testing Apparatus.
Air
Air Conditioners
RASL- JEC Series
“Proper sizing and installation of equipment is critical to achieve
optimal performance. Ask your Contractor for details or visit www.energystar.gov.”
16.0
Air
Table of Contents
RASL- JEC Series
2
TABLE OF CONTENTS
Model Features ..............................................................................................3
Model Number Identification ............................................................................4
Accessories....................................................................................................4
Scroll Compressor ..........................................................................................4
Performance Data ......................................................................................5-38
Electrical & Physical Data ..............................................................................39
Unit Dimensions............................................................................................40
Refrigerant Line Size Information ..............................................................41-43
Limited Warranty ..........................................................................................44
Air
Model Features
RASL- JEC Series
3
The Rheem exclusive Dual 7-Segment LED Display easily shows system operating status codes and diagnostic codes.
A Sealed Switch replaces the standard
contactor and features optical control and latching mecha­nism. The sealed
switch prevents infiltration of insects and dust. A minimal switching arc, by the optical control, offers greater reliability. The latching mechanism con­sumes less power while reducing chatter.
The Status Indication and System Diagnostics feature thermostat communication capability, built-in diagnostics, current sensing and high & low pressure switch monitor­ing. The thermostat communication capability alerts the
homeowner to any necessary ser­vice requirements. Faster, more accurate service is provided by the built-in diagnostics, by providing the HVAC professional with dependable information. In addition, high and low pressure-switch moni­toring prevents the system from operating outside of its normal parameters.
The fault recall feature will allow for the last six fault-codes to be displayed, and will retain these codes even if power failure occurs.
Built-in short-cycle protection allows the compressor to restart easily without oil removal.
A 30-second minimum run-time for every compressor call allows the oil to return to the compressor.
Active Protection monitors the system to prevent nuisance lockouts and prevents compressor operation when poten­tially harmful conditions are detected.
The compressor and fan are controlled independently, which reduces the starting load and light dimming.
A manual push-button is offered to operate the com­pressor and fan for 5 seconds to allow for an operation check.
In order to save time and money, replacement automotive fuses can be utilized instead of replacing the entire control board.
Standard Features:
RASL- JEC Condensing Units
1. Scroll compressor is hermetically sealed and incorporates internal high temperature motor overload protection, and durable insulation on the motor windings. It is externally mounted on rubber grommets to reduce vibration and noise.
2. Compressors have an internal pressure relief assembly to protect against excessive pressure differential.
3. All refrigerant connections are on the exterior of the unit, located close to the ground for neat appearing installations.
4. Cabinet is constructed of powder painted galvanized steel. The full wrap-around louvered grille protects the coil from damage.
5. Sound Blanket-enhanced compressor sound blanket is standard.
6. Copper tube—aluminum fin coils are used on all models.
7. The control box is located in the top corner of the cabinet
providing for easy access through a service panel.
8. Service valves are standard on all models.
9. Field connections for power and control wiring are kept
separate.
10. Every unit is factory charged and run-tested.
11. Separate compressor compartment for easy service
access.
12. Drawn, painted base pan for extra corrosion resistance and sound reduction.
13. The RASL- JEC has a 10-year limited parts warranty, plus a 10-year conditional unit replacement warranty. Refer to the General Terms of Limited Warranty for more details.
14. Hard Start Kits—Standard on all JEC models.
15. Control Box Cover.
16. The RASL- JEC is shipped with a liquid line filter drier, and
also features factory-installed low and high pressure controls.
The
Comfort Control2System
Features:
Scroll
®
Compressor
024 & 036 nominal capacities
— Single scroll Ultra-Tech two-stage
compressor
— Operates at 67% capacity in non
peak conditions to improve efficiency and comfort (humidity control)
039, 048 & 60 nominal capacities
— Dual Drive scroll compressors –
Tandem
— Operates at 50% capacity on first
compressor in non peak conditions to improve efficiency and comfort (humidity control)
— Compressor “A” operated by control
board “A” Compressor “B” operated by control board “B”.
Air
Model I.D./Accessories/Compressor
RASL- JEC Series
4
Model Number Identification
R A S L 024
COOLING
CAPACITY
025 = 24,000 BTU/HR [7.03 kW] 037 = 36,000 BTU/HR [10.55 kW] 039 = 39,000 BTU/HR [11.43 kW] 048 = 48,000 BTU/HR [14.07 kW] 060 = 60,000 BTU/HR [17.6 kW]
J EC
RHEEM REMOTE
CONDENSING
UNIT
18-SEER DESIGN
SERIES
L = FIRST DESIGN
SERIES
ELECTRICAL
DESIGNATION
J = 208/230V-1-60
EC = EQUIPPED WITH
THE
COMFORT
CONTROL
2
SYSTEM
Accessories
Communicating 2 Wire Kit (RXME-A02)
* Photos are representative. Actual models may vary.
For detailed thermostat match-up information, see specification sheet form number T11-001.
300-Series *
Deluxe Programmable
400-Series *
Special Applications/ Programmable
500-Series *
Communicating/ Programmable
200-Series *
Programmable
Scroll®Compressor
The reliable scroll compressor is the key to efficiency for this Rheem model. It’s the latest in high-efficiency compressor tech­nology. The advanced scroll compressor offers low noise and vibration characteristics and features tolerance to liquid refrigerant and system contamination. The scroll compressor also has low start torque, reducing start problems in the field. And its unique design enables air conditioners to perform efficiently and quietly.
[ ] Designates Metric Conversions
Thermostats
Air
Performance Data
RASL- JEC Series
5
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
025JEC
RCSN-H*2421
RHPN-HM2421
1 14500 [4.2] 6100 [1.8]
25800 [7.6] 18 14
575 [271] 71
2 19300 [5.7] 6500 [1.9] 825 [389] 74
1 - dehumid 12100 [3.5] 5200 [1.5] 475 [224]
2 - dehumid 17300 [5.1] 7300 [2.1] 675 [319]
RCFL-H*2417
RGFE-06?MCK?
1 13800 [4.0] 6200 [1.8]
24600 [7.2] 17 13
575 [271] 71
2 18200 [5.3] 6400 [1.9] 800 [378] 74
RGFE-07?MCK?
1 14100 [4.1] 6100 [1.8]
24600 [7.2] 17 13
600 [283] 71
2 18200 [5.3] 6400 [1.9] 825 [389] 74
RGFG-06?MCK?
1 13800 [4.0] 6200 [1.8]
24600 [7.2] 17 13
575 [271] 71
2 18200 [5.3] 6400 [1.9] 800 [378] 74
RGFG-07?MCK?
1 14100 [4.1] 6100 [1.8]
24600 [7.2] 17 13
600 [283] 71
2 18200 [5.3] 6400 [1.9] 850 [401] 74
RGGE-06?MCK?
1 14100 [4.1] 6100 [1.8]
24800 [7.3] 17 13
625 [295] 71
2 18400 [5.4] 6400 [1.9] 825 [389] 74
RGGE-07?MCK?
1 13800 [4.0] 6200 [1.8]
24800 [7.3] 17 13
575 [271] 71
2 18400 [5.4] 6400 [1.9] 800 [378] 74
RGJF-06?MCK?
1 14100 [4.1] 6100 [1.8]
24800 [7.3] 17 13
625 [295] 71
2 18400 [5.4] 6400 [1.9] 825 [389] 74
RGJF-07?MCK?
1 13800 [4.0] 6200 [1.8]
24800 [7.3] 17 13
575 [271] 71
2 18400 [5.4] 6400 [1.9] 800 [378] 74
RGLE-07?AMK?
1 14300 [4.2] 6100 [1.8]
24800 [7.3] 17.5 13
600 [283] 71
2 18400 [5.4] 6400 [1.9] 800 [378] 74
RGPE-05?BMK?
1 13800 [4.0] 6200 [1.8]
24800 [7.3] 17 13
575 [271] 71
2 18400 [5.4] 6400 [1.9] 800 [378] 74
RGPE-07?AMK?
1 14300 [4.2] 6100 [1.8]
24800 [7.3] 17.5 13
625 [295] 71
2 18400 [5.4] 6400 [1.9] 825 [389] 74
RGRM-04?MAE?
1 13800 [4.0] 6200 [1.8]
24600 [7.2] 17 13
575 [271] 71
2 18200 [5.3] 6400 [1.9] 800 [378] 74
RGRM-06?MAE?
1 14100 [4.1] 6100 [1.8]
24600 [7.2] 17 13
600 [283] 71
2 18200 [5.3] 6400 [1.9] 825 [389] 74
RGRM-07?MAE?
1 14100 [4.1] 6100 [1.8]
24400 [7.1] 16.5 13
625 [295] 71
2 18000 [5.3] 6400 [1.9] 850 [401] 74
RGTM-06?MAE?
1 14900 [4.4] 5900 [1.7]
24600 [7.2] 17 13
750 [354] 71
2 18200 [5.3] 6400 [1.9] 825 [389] 74
ROCA-070E03
1 14300 [4.2] 6100 [1.8]
24800 [7.3] 17.5 13
600 [283] 71
2 18400 [5.4] 6400 [1.9] 800 [378] 74
ROLA-070E03
1 14100 [4.1] 6100 [1.8]
24800 [7.3] 17 13
600 [283] 71
2 18400 [5.4] 6400 [1.9] 800 [378] 74
RCFL-H*2417+RXMD-C06 Coil Only
1 13700 [4.0] 6100 [1.8]
24200 [7.1] 15.1 12.5
625 [295] 71
2 17800 [5.2] 6400 [1.9] 825 [389] 74
RCFL-H*2617
RGFE-06?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGFE-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
600 [283] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RASL- JEC Series
6
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
025JEC
RCFL-H*2617
RGFG-06?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGFG-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
600 [283] 71
2 19100 [5.6] 6500 [1.9] 850 [401] 74
RGGE-06?MCK?
1 15000 [4.4] 6000 [1.8]
25600 [7.5] 18 13
625 [295] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGGE-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGJF-06?MCK?
1 15000 [4.4] 6000 [1.8]
25600 [7.5] 18 13
625 [295] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGJF-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGLE-07?AMK?
1 14500 [4.2] 6100 [1.8]
25800 [7.6] 18 13
600 [283] 71
2 19300 [5.7] 6500 [1.9] 800 [378] 74
RGPE-05?BMK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGPE-07?AMK?
1 15000 [4.4] 6000 [1.8]
25800 [7.6] 18 13
625 [295] 71
2 19300 [5.7] 6500 [1.9] 825 [389] 74
RGRM-04?MAE?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGRM-06?MAE?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
600 [283] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGRM-07?MAE?
1 14800 [4.3] 6000 [1.8]
25400 [7.4] 17.5 13
625 [295] 71
2 18900 [5.5] 6500 [1.9] 850 [401] 74
RGTM-06?MAE?
1 15800 [4.6] 5800 [1.7]
25600 [7.5] 18 13
750 [354] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
ROCA-070E03
1 14500 [4.2] 6100 [1.8]
25800 [7.6] 18 13
600 [283] 71
2 19300 [5.7] 6500 [1.9] 800 [378] 74
ROLA-070E03
1 14500 [4.2] 6100 [1.8]
25800 [7.6] 18 13
600 [283] 71
2 19300 [5.7] 6500 [1.9] 800 [378] 74
RCFL-H*2617+RXMD-C06 Coil Only
1 14400 [4.2] 6000 [1.8]
25200 [7.4] 15.5 12.5
625 [295] 71
2 18700 [5.5] 6500 [1.9] 825 [389] 74
RCFL-H*2621
RGFE-06?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGFE-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
600 [283] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGFG-06?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGFG-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
600 [283] 71
2 19100 [5.6] 6500 [1.9] 850 [401] 74
RGGE-06?MCK?
1 15000 [4.4] 6000 [1.8]
25600 [7.5] 18 13
625 [295] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGGE-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
7
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
025JEC
RCFL-H*2621
RGJF-06?MCK?
1 15000 [4.4] 6000 [1.8]
25600 [7.5] 18 13
625 [295] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGJF-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGLE-07?AMK?
1 14500 [4.2] 6100 [1.8]
25800 [7.6] 18 13
600 [283] 71
2 19300 [5.7] 6500 [1.9] 800 [378] 74
RGPE-05?BMK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGPE-07?AMK?
1 15000 [4.4] 6000 [1.8]
25800 [7.6] 18 13
625 [295] 71
2 19300 [5.7] 6500 [1.9] 825 [389] 74
RGRM-04?MAE?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGRM-06?MAE?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
600 [283] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGRM-07?MAE?
1 14800 [4.3] 6000 [1.8]
25400 [7.4] 17.5 13
625 [295] 71
2 18900 [5.5] 6500 [1.9] 850 [401] 74
RGTM-06?MAE?
1 15800 [4.6] 5800 [1.7]
25600 [7.5] 18 13
750 [354] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
ROCA-070E03
1 14500 [4.2] 6100 [1.8]
25800 [7.6] 18 13
600 [283] 71
2 19300 [5.7] 6500 [1.9] 800 [378] 74
ROLA-070E03
1 14500 [4.2] 6100 [1.8]
25800 [7.6] 18 13
600 [283] 71
2 19300 [5.7] 6500 [1.9] 800 [378] 74
RCFL-H*2621+RXMD-C06 Coil Only
1 14400 [4.2] 6000 [1.8]
25200 [7.4] 15.5 12.5
625 [295] 71
2 18700 [5.5] 6500 [1.9] 825 [389] 74
RCFN-H*2417
RGFE-06?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGFE-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
600 [283] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGFG-06?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGFG-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
600 [283] 71
2 19100 [5.6] 6500 [1.9] 850 [401] 74
RGGE-06?MCK?
1 15000 [4.4] 6000 [1.8]
25600 [7.5] 18 13
625 [295] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGGE-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGJF-06?MCK?
1 15000 [4.4] 6000 [1.8]
25600 [7.5] 18 13
625 [295] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGJF-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGLE-07?AMK?
1 14500 [4.2] 6100 [1.8]
25800 [7.6] 18 13
600 [283] 71
2 19300 [5.7] 6500 [1.9] 800 [378] 74
RGPE-05?BMK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RASL- JEC Series
8
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
025JEC
RCFN-H*2417
RGPE-07?AMK?
1 15000 [4.4] 6000 [1.8]
25800 [7.6] 18 13
625 [295] 71
2 19300 [5.7] 6500 [1.9] 825 [389] 74
RGRM-04?MAE?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGRM-06?MAE?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
600 [283] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGRM-07?MAE?
1 14800 [4.3] 6000 [1.8]
25400 [7.4] 17.5 13
625 [295] 71
2 18900 [5.5] 6500 [1.9] 850 [401] 74
RGTM-06?MAE?
1 15800 [4.6] 5800 [1.7]
25600 [7.5] 18 13
750 [354] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
ROCA-070E03
1 14500 [4.2] 6100 [1.8]
25800 [7.6] 18 13
600 [283] 71
2 19300 [5.7] 6500 [1.9] 800 [378] 74
ROLA-070E03
1 14500 [4.2] 6100 [1.8]
25800 [7.6] 18 13
600 [283] 71
2 19300 [5.7] 6500 [1.9] 800 [378] 74
RCFN-H*2417+RXMD-C06 Coil Only
1 14400 [4.2] 6000 [1.8]
25200 [7.4] 15.5 12.5
625 [295] 71
2 18700 [5.5] 6500 [1.9] 825 [389] 74
RCFN-H*2421
RGFE-06?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGFE-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
600 [283] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGFG-06?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGFG-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
600 [283] 71
2 19100 [5.6] 6500 [1.9] 850 [401] 74
RGGE-06?MCK?
1 15000 [4.4] 6000 [1.8]
25600 [7.5] 18 13
625 [295] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGGE-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGJF-06?MCK?
1 15000 [4.4] 6000 [1.8]
25600 [7.5] 18 13
625 [295] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGJF-07?MCK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGLE-07?AMK?
1 14500 [4.2] 6100 [1.8]
25800 [7.6] 18 13
600 [283] 71
2 19300 [5.7] 6500 [1.9] 800 [378] 74
RGPE-05?BMK?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGPE-07?AMK?
1 15000 [4.4] 6000 [1.8]
25800 [7.6] 18 13
625 [295] 71
2 19300 [5.7] 6500 [1.9] 825 [389] 74
RGRM-04?MAE?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
575 [271] 71
2 19100 [5.6] 6500 [1.9] 800 [378] 74
RGRM-06?MAE?
1 14500 [4.2] 6100 [1.8]
25600 [7.5] 18 13
600 [283] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
RGRM-07?MAE?
1 14800 [4.3] 6000 [1.8]
25400 [7.4] 17.5 13
625 [295] 71
2 18900 [5.5] 6500 [1.9] 850 [401] 74
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RASL- JEC Series
9
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
025JEC
RCFN-H*2421
RGTM-06?MAE?
1 15800 [4.6] 5800 [1.7]
25600 [7.5] 18 13
750 [354] 71
2 19100 [5.6] 6500 [1.9] 825 [389] 74
ROCA-070E03
1 14500 [4.2] 6100 [1.8]
25800 [7.6] 18 13
600 [283] 71
2 19300 [5.7] 6500 [1.9] 800 [378] 74
ROLA-070E03
1 14500 [4.2] 6100 [1.8]
25800 [7.6] 18 13
600 [283] 71
2 19300 [5.7] 6500 [1.9] 800 [378] 74
RCFN-H*2421+RXMD-C06 Coil Only
1 14400 [4.2] 6000 [1.8]
25200 [7.4] 15.5 12.5
625 [295] 71
2 18700 [5.5] 6500 [1.9] 825 [389] 74
RCQD-2417
RBHM-17J
1 15000 [4.4] 5600 [1.6]
26000 [7.6] 18 13
600 [283] 71
2 20300 [5.9] 5700 [1.7] 825 [389] 74
RGFE-06?MCK?
1 14700 [4.3] 5700 [1.7]
26000 [7.6] 18 13
575 [271] 71
2 20300 [5.9] 5700 [1.7] 800 [378] 74
RGFE-07?MCK?
1 15000 [4.4] 5600 [1.6]
26000 [7.6] 18 13
600 [283] 71
2 20300 [5.9] 5700 [1.7] 825 [389] 74
RGFG-06?MCK?
1 14700 [4.3] 5700 [1.7]
26000 [7.6] 18 13
575 [271] 71
2 20300 [5.9] 5700 [1.7] 800 [378] 74
RGFG-07?MCK?
1 15000 [4.4] 5600 [1.6]
26000 [7.6] 18 13
600 [283] 71
2 20300 [5.9] 5700 [1.7] 850 [401] 74
RGJF-06?MCK?
1 15000 [4.4] 5600 [1.6]
26000 [7.6] 18 13
625 [295] 71
2 20300 [5.9] 5700 [1.7] 825 [389] 74
RGJF-07?MCK?
1 14700 [4.3] 5700 [1.7]
26000 [7.6] 18 13
575 [271] 71
2 20300 [5.9] 5700 [1.7] 800 [378] 74
RGPE-05?BMK?
1 14700 [4.3] 5700 [1.7]
26000 [7.6] 18 13
575 [271] 71
2 20300 [5.9] 5700 [1.7] 800 [378] 74
RGPE-07?AMK?
1 15000 [4.4] 5600 [1.6]
26200 [7.7] 18 13
625 [295] 71
2 20500 [6.0] 5700 [1.7] 825 [389] 74
RGPR-05?BMK?
1 15000 [4.4] 5600 [1.6]
25800 [7.6] 17.5 13
600 [283] 71
2 20000 [5.9] 5800 [1.7] 775 [366] 74
RGPR-07?AMK?
1 15000 [4.4] 5600 [1.6]
26000 [7.6] 18 13
600 [283] 71
2 20300 [5.9] 5700 [1.7] 800 [378] 74
RGRM-04?MAE?
1 14700 [4.3] 5700 [1.7]
26000 [7.6] 17.5 13
575 [271] 71
2 20300 [5.9] 5700 [1.7] 800 [378] 74
RGRM-06?MAE?
1 15000 [4.4] 5600 [1.6]
26000 [7.6] 18 13
600 [283] 71
2 20300 [5.9] 5700 [1.7] 825 [389] 74
RGRM-07?MAE?
1 15000 [4.4] 5600 [1.6]
25800 [7.6] 17.5 13
625 [295] 71
2 20100 [5.9] 5700 [1.7] 850 [401] 74
RGTM-06?MAE?
1 15900 [4.7] 5300 [1.6]
26000 [7.6] 18 13
750 [354] 71
2 20300 [5.9] 5700 [1.7] 825 [389] 74
ROCA-070E03
1 15000 [4.4] 5600 [1.6]
26200 [7.7] 18 13
600 [283] 71
2 20500 [6.0] 5700 [1.7] 800 [378] 74
ROLA-070E03
1 15000 [4.4] 5600 [1.6]
26200 [7.7] 18 13
600 [283] 71
2 20500 [6.0] 5700 [1.7] 800 [378] 74
RCQD-2417+RXMD-C06 Coil Only
1 14600 [4.3] 5600 [1.6]
25600 [7.5] 15.5 13
625 [295] 71
2 19900 [5.8] 5700 [1.7] 825 [389] 74
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RASL- JEC Series
10
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
037JEC
RCSN-H*3624
RHPN-HM3624
1 22300 [6.5] 8500 [2.5]
38500 [11.3] 18 14
925 [437] 69
2 27900 [8.2] 10600 [3.1] 1125 [531] 72
1 - dehumid 19100 [5.6] 7100 [2.1] 750 [354]
2 - dehumid 25800 [7.6] 11200 [3.3] 950 [448]
RCFL-H*3617
RGFE-06?MCK?
1 18800 [5.5] 9200 [2.7]
34600 [10.1] 15 11.5
875 [413] 69
2 23700 [6.9] 10900 [3.2] 1200 [566] 72
RGFE-07?MCK?
1 18800 [5.5] 9200 [2.7]
34600 [10.1] 15 11
875 [413] 69
2 23800 [7.0] 10800 [3.2] 1225 [578] 72
RGFG-06?MCK?
1 18800 [5.5] 9200 [2.7]
34600 [10.1] 15 11.5
875 [413] 69
2 23700 [6.9] 10900 [3.2] 1200 [566] 72
RGFG-07?MCK?
1 18400 [5.4] 9400 [2.8]
34000 [10.0] 15.5 12
800 [378] 69
2 22300 [6.5] 11700 [3.4] 1000 [472] 72
RGGE-06?MCK?
1 19300 [5.7] 9100 [2.7]
34800 [10.2] 15.5 11.5
925 [437] 69
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGGE-07?MCK?
1 19000 [5.6] 9200 [2.7]
34600 [10.1] 15.5 11.5
875 [413] 69
2 23700 [6.9] 10900 [3.2] 1200 [566] 72
RGJF-06?MCK?
1 19300 [5.7] 9100 [2.7]
34800 [10.2] 15.5 11.5
925 [437] 69
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGJF-07?MCK?
1 19000 [5.6] 9200 [2.7]
34600 [10.1] 15.5 11.5
875 [413] 69
2 23700 [6.9] 10900 [3.2] 1200 [566] 72
RGLE-07?AMK?
1 19000 [5.6] 9200 [2.7]
34800 [10.2] 15.5 12
875 [413] 69
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGLR-07?AMK?
1 19500 [5.7] 9100 [2.7]
34800 [10.2] 15.5 12
925 [437] 69
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGPE-05?BMK?
1 19300 [5.7] 9100 [2.7]
34800 [10.2] 15.5 11.5
900 [425] 69
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGPE-07?AMK?
1 19300 [5.7] 9100 [2.7]
34800 [10.2] 15.5 11.5
900 [425] 69
2 24000 [7.0] 10800 [3.2] 1225 [578] 72
RGPR-05?BMK?
1 19100 [5.6] 9100 [2.7]
34600 [10.1] 15 11.5
900 [425] 69
2 23700 [6.9] 10900 [3.2] 1200 [566] 72
RGPR-07?AMK?
1 19300 [5.7] 9100 [2.7]
34800 [10.2] 15.5 12
900 [425] 69
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGRM-04?MAE?
1 19100 [5.6] 9100 [2.7]
34600 [10.1] 15 11.5
925 [437] 69
2 23700 [6.9] 10900 [3.2] 1200 [566] 72
RGRM-06?MAE?
1 18300 [5.4] 9500 [2.8]
34000 [10.0] 15.5 12
775 [366] 69
2 22300 [6.5] 11700 [3.4] 1000 [472] 72
RGRM-07?MAE?
1 18400 [5.4] 9400 [2.8]
33800 [9.9] 15 11.5
800 [378] 69
2 22200 [6.5] 11600 [3.4] 1025 [484] 72
RGTM-06?MAE?
1 19300 [5.7] 9100 [2.7]
34200 [10.0] 15.5 12
900 [425] 69
2 22600 [6.6] 11600 [3.4] 1025 [484] 72
ROCA-070E03
1 18600 [5.4] 9400 [2.8]
34200 [10.0] 16 12.5
800 [378] 69
2 22500 [6.6] 11700 [3.4] 1000 [472] 72
ROCA-070E04
1 18600 [5.4] 9400 [2.8]
34200 [10.0] 16 12.5
800 [378] 69
2 22500 [6.6] 11700 [3.4] 1000 [472] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RASL- JEC Series
11
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
037JEC
RCFL-H*3617
ROLA-070E03
1 19500 [5.7] 9100 [2.7]
35000 [10.3] 16 12
900 [425] 69
2 24000 [7.0] 11000 [3.2] 1175 [554] 72
ROLA-070E04
1 19500 [5.7] 9100 [2.7]
35000 [10.3] 16 12
900 [425] 69
2 24000 [7.0] 11000 [3.2] 1175 [554] 72
RCFL-H*3617+RXMD-C06 Coil Only
1 18900 [5.5] 9100 [2.7]
34400 [10.1] 14 11.5
925 [437] 69
2 23200 [6.8] 11200 [3.3] 1075 [507] 72
RCFL-H*3621
RGFE-06?MCK?
1 19000 [5.6] 9200 [2.7]
34600 [10.1] 15 11.5
875 [413] 69
2 23700 [6.9] 10900 [3.2] 1200 [566] 72
RGFE-07?MCK?
1 19000 [5.6] 9200 [2.7]
34600 [10.1] 15 11
875 [413] 69
2 23800 [7.0] 10800 [3.2] 1225 [578] 72
RGFE-09?ZCM?
1 19000 [5.6] 9200 [2.7]
35000 [10.3] 16 12
875 [413] 69
2 24100 [7.1] 10900 [3.2] 1200 [566] 72
RGFE-10?ZCM?
1 19500 [5.7] 9100 [2.7]
35000 [10.3] 16 12
900 [425] 69
2 24200 [7.1] 10800 [3.2] 1225 [578] 72
RGFG-06?MCK?
1 19000 [5.6] 9200 [2.7]
34600 [10.1] 15 11.5
875 [413] 69
2 23700 [6.9] 10900 [3.2] 1200 [566] 72
RGFG-07?MCK?
1 18400 [5.4] 9400 [2.8]
34000 [10.0] 15.5 12
800 [378] 69
2 22300 [6.5] 11700 [3.4] 1000 [472] 72
RGFG-09?ZCM?
1 19000 [5.6] 9200 [2.7]
35000 [10.3] 16 12
875 [413] 69
2 24100 [7.1] 10900 [3.2] 1200 [566] 72
RGFG-10?ZCM?
1 19500 [5.7] 9100 [2.7]
35000 [10.3] 16 12
900 [425] 69
2 24100 [7.1] 10900 [3.2] 1200 [566] 72
RGGE-06?MCK?
1 19300 [5.7] 9100 [2.7]
34800 [10.2] 15.5 11.5
925 [437] 69
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGGE-07?MCK?
1 19000 [5.6] 9200 [2.7]
34800 [10.2] 15.5 11.5
875 [413] 69
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGGE-09?ZCM?
1 19000 [5.6] 9200 [2.7]
35200 [10.3] 16 12
875 [413] 69
2 24400 [7.1] 10800 [3.2] 1225 [578] 72
RGGE-10?ZCM?
1 19000 [5.6] 9200 [2.7]
35000 [10.3] 16 12
875 [413] 69
2 24100 [7.1] 10900 [3.2] 1200 [566] 72
RGJF-06?MCK?
1 19300 [5.7] 9100 [2.7]
34800 [10.2] 15.5 11.5
925 [437] 69
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGJF-07?MCK?
1 19000 [5.6] 9200 [2.7]
34800 [10.2] 15.5 11.5
875 [413] 69
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGJF-09?ZCM?
1 19000 [5.6] 9200 [2.7]
35200 [10.3] 16 12
875 [413] 69
2 24400 [7.1] 10800 [3.2] 1225 [578] 72
RGJF-10?ZCM?
1 19000 [5.6] 9200 [2.7]
35000 [10.3] 16 12
875 [413] 69
2 24100 [7.1] 10900 [3.2] 1200 [566] 72
RGLE-07?AMK?
1 19000 [5.6] 9200 [2.7]
35000 [10.3] 15.5 12
875 [413] 69
2 24100 [7.1] 10900 [3.2] 1200 [566] 72
RGLE-07?BRQ?
1 18300 [5.4] 9500 [2.8]
34400 [10.1] 16 12.5
775 [366] 69
2 22800 [6.7] 11600 [3.4] 1025 [484] 72
RGLE-10?BRM?
1 19200 [5.6] 9200 [2.7]
35200 [10.3] 16 12.5
875 [413] 69
2 24300 [7.1] 10900 [3.2] 1200 [566] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RASL- JEC Series
12
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
037JEC RCFL-H*3621
RGLR-07?AMK?
1 19500 [5.7] 9100 [2.7]
34800 [10.2] 16 12
925 [437] 69
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGLR-07?BRQ?
1 19500 [5.7] 9100 [2.7]
35200 [10.3] 16 12.5
900 [425] 69
2 24400 [7.1] 10800 [3.2] 1225 [578] 72
RGLR-10?BRM?
1 19500 [5.7] 9100 [2.7]
35200 [10.3] 16 12.5
925 [437] 69
2 24300 [7.1] 10900 [3.2] 1200 [566] 72
RGPE-05?BMK?
1 19300 [5.7] 9100 [2.7]
34800 [10.2] 15.5 11.5
900 [425] 69
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGPE-07?AMK?
1 19500 [5.7] 9100 [2.7]
35000 [10.3] 15.5 12
900 [425] 69
2 24200 [7.1] 10800 [3.2] 1225 [578] 72
RGPE-07?BRQ?
1 19500 [5.7] 9100 [2.7]
35400 [10.4] 16 12.5
900 [425] 69
2 24600 [7.2] 10800 [3.2] 1225 [578] 72
RGPE-10?BRM?
1 19500 [5.7] 9100 [2.7]
35400 [10.4] 16 12.5
900 [425] 69
2 24600 [7.2] 10800 [3.2] 1225 [578] 72
RGPR-05?BMK?
1 19300 [5.7] 9100 [2.7]
34600 [10.1] 15 11.5
900 [425] 69
2 23700 [6.9] 10900 [3.2] 1200 [566] 72
RGPR-07?AMK?
1 19300 [5.7] 9100 [2.7]
34800 [10.2] 15.5 12
900 [425] 69
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGPR-07?BRQ?
1 19200 [5.6] 9200 [2.7]
35200 [10.3] 16 12.5
875 [413] 69
2 24300 [7.1] 10900 [3.2] 1200 [566] 72
RGPR-10?BRM?
1 19500 [5.7] 9100 [2.7]
35200 [10.3] 16 12
925 [437] 69
2 24400 [7.1] 10800 [3.2] 1225 [578] 72
RGRM-04?MAE?
1 19100 [5.6] 9100 [2.7]
34600 [10.1] 15 11.5
925 [437] 69
2 23700 [6.9] 10900 [3.2] 1200 [566] 72
RGRM-06?MAE?
1 18300 [5.4] 9500 [2.8]
34000 [10.0] 15.5 12
775 [366] 69
2 22300 [6.5] 11700 [3.4] 1000 [472] 72
RGRM-07?MAE?
1 18400 [5.4] 9400 [2.8]
33800 [9.9] 15.5 11.5
800 [378] 69
2 22200 [6.5] 11600 [3.4] 1025 [484] 72
RGRM-07?YBG?
1 18700 [5.5] 9300 [2.7]
34400 [10.1] 15 11
850 [401] 69
2 23500 [6.9] 10900 [3.2] 1200 [566] 72
RGRM-09?ZAJ?
1 19300 [5.7] 9100 [2.7]
35000 [10.3] 15.5 12
950 [448] 69
2 24200 [7.1] 10800 [3.2] 1225 [578] 72
RGRM-10?ZAJ?
1 19000 [5.6] 9200 [2.7]
34600 [10.1] 15.5 12
875 [413] 69
2 23400 [6.9] 11200 [3.3] 1150 [543] 72
RGTM-06?MAE?
1 19300 [5.7] 9100 [2.7]
34200 [10.0] 15.5 12
900 [425] 69
2 22600 [6.6] 11600 [3.4] 1025 [484] 72
RGTM-07?RBG?
1 18600 [5.4] 9400 [2.8]
34600 [10.1] 16 12.5
800 [378] 69
2 23100 [6.8] 11500 [3.4] 1050 [495] 72
RGTM-09?ZAJ?
1 19900 [5.8] 8900 [2.6]
35200 [10.3] 16 12
975 [460] 69
2 24400 [7.1] 10800 [3.2] 1225 [578] 72
ROCA-070E03
1 18600 [5.4] 9400 [2.8]
34200 [10.0] 16 12.5
800 [378] 69
2 22500 [6.6] 11700 [3.4] 1000 [472] 72
ROCA-070E04
1 18600 [5.4] 9400 [2.8]
34200 [10.0] 16 12.5
800 [378] 69
2 22500 [6.6] 11700 [3.4] 1000 [472] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RASL- JEC Series
13
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
037JEC
RCFL-H*3621
ROLA-070E03
1 19500 [5.7] 9100 [2.7]
35000 [10.3] 16 12
900 [425] 69
2 24000 [7.0] 11000 [3.2] 1175 [554] 72
ROLA-070E04
1 19500 [5.7] 9100 [2.7]
35000 [10.3] 16 12
900 [425] 69
2 24000 [7.0] 11000 [3.2] 1175 [554] 72
ROLA-115E05
1 19500 [5.7] 9100 [2.7]
35200 [10.3] 16 12.5
900 [425] 69
2 24300 [7.1] 10900 [3.2] 1200 [566] 72
RCFL-H*3621+RXMD-C06 Coil Only
1 18900 [5.5] 9100 [2.7]
34400 [10.1] 14 11.5
925 [437] 69
2 23200 [6.8] 11200 [3.3] 1125 [531] 72
RCFL-H*3821
RGFE-06?MCK?
1 18900 [5.5] 9700 [2.8]
35400 [10.4] 15.5 12
875 [413] 69
2 24200 [7.1] 11200 [3.3] 1200 [566] 72
RGFE-07?MCK?
1 18900 [5.5] 9700 [2.8]
35400 [10.4] 15.5 11.5
875 [413] 69
2 24300 [7.1] 11100 [3.3] 1225 [578] 72
RGFE-09?ZCM?
1 19100 [5.6] 9700 [2.8]
35800 [10.5] 16 12.5
875 [413] 69
2 24600 [7.2] 11200 [3.3] 1200 [566] 72
RGFE-10?ZCM?
1 19700 [5.8] 9500 [2.8]
35800 [10.5] 16.5 12.5
900 [425] 69
2 24700 [7.2] 11100 [3.3] 1225 [578] 72
RGFG-06?MCK?
1 18900 [5.5] 9700 [2.8]
35400 [10.4] 15.5 12
875 [413] 69
2 24200 [7.1] 11200 [3.3] 1200 [566] 72
RGFG-07?MCK?
1 18500 [5.4] 9900 [2.9]
34800 [10.2] 16 12.5
800 [378] 69
2 22800 [6.7] 12000 [3.5] 1000 [472] 72
RGFG-09?ZCM?
1 19100 [5.6] 9700 [2.8]
35800 [10.5] 16 12.5
875 [413] 69
2 24600 [7.2] 11200 [3.3] 1200 [566] 72
RGFG-10?ZCM?
1 19500 [5.7] 9500 [2.8]
35800 [10.5] 16 12.5
900 [425] 69
2 24600 [7.2] 11200 [3.3] 1200 [566] 72
RGGE-06?MCK?
1 19500 [5.7] 9500 [2.8]
35600 [10.4] 16 12
925 [437] 69
2 24400 [7.1] 11200 [3.3] 1200 [566] 72
RGGE-07?MCK?
1 18900 [5.5] 9700 [2.8]
35400 [10.4] 15.5 12
875 [413] 69
2 24200 [7.1] 11200 [3.3] 1200 [566] 72
RGGE-09?ZCM?
1 20200 [5.9] 9200 [2.7]
36000 [10.5] 16 12.5
1025 [484] 69
2 25000 [7.3] 11000 [3.2] 1250 [590] 72
RGGE-10?ZCM?
1 19100 [5.6] 9700 [2.8]
35800 [10.5] 16 12.5
875 [413] 69
2 24600 [7.2] 11200 [3.3] 1200 [566] 72
RGJF-06?MCK?
1 19500 [5.7] 9500 [2.8]
35600 [10.4] 16 12
925 [437] 69
2 24400 [7.1] 11200 [3.3] 1200 [566] 72
RGJF-07?MCK?
1 18900 [5.5] 9700 [2.8]
35400 [10.4] 15.5 12
875 [413] 69
2 24200 [7.1] 11200 [3.3] 1200 [566] 72
RGJF-09?ZCM?
1 20200 [5.9] 9200 [2.7]
36000 [10.5] 16 12.5
1025 [484] 69
2 25000 [7.3] 11000 [3.2] 1250 [590] 72
RGJF-10?ZCM?
1 19100 [5.6] 9700 [2.8]
35800 [10.5] 16 12.5
875 [413] 69
2 24600 [7.2] 11200 [3.3] 1200 [566] 72
RGLE-07?AMK?
1 19100 [5.6] 9700 [2.8]
35600 [10.4] 16 12.5
875 [413] 69
2 24400 [7.1] 11200 [3.3] 1200 [566] 72
RGLE-07?BRQ?
1 19700 [5.8] 9500 [2.8]
36000 [10.5] 16.5 13
925 [437] 69
2 24900 [7.3] 11100 [3.3] 1225 [578] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RASL- JEC Series
14
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
037JEC RCFL-H*3821
RGLE-10?BRM?
1 19300 [5.7] 9700 [2.8]
36000 [10.5] 16.5 13
875 [413] 69
2 24800 [7.3] 11200 [3.3] 1200 [566] 72
RGLR-07?AMK?
1 19500 [5.7] 9500 [2.8]
35600 [10.4] 16 12.5
925 [437] 69
2 24400 [7.1] 11200 [3.3] 1200 [566] 72
RGLR-07?BRQ?
1 19700 [5.8] 9500 [2.8]
36000 [10.5] 16.5 13
900 [425] 69
2 24900 [7.3] 11100 [3.3] 1225 [578] 72
RGLR-10?BRM?
1 19700 [5.8] 9500 [2.8]
36000 [10.5] 16.5 13
925 [437] 69
2 24800 [7.3] 11200 [3.3] 1200 [566] 72
RGPE-05?BMK?
1 19500 [5.7] 9500 [2.8]
35600 [10.4] 16 12
900 [425] 69
2 24400 [7.1] 11200 [3.3] 1200 [566] 72
RGPE-07?AMK?
1 19500 [5.7] 9500 [2.8]
35800 [10.5] 16 12.5
900 [425] 69
2 24700 [7.2] 11100 [3.3] 1225 [578] 72
RGPE-07?BRQ?
1 19700 [5.8] 9500 [2.8]
36200 [10.6] 16.5 13
900 [425] 69
2 25100 [7.4] 11100 [3.3] 1225 [578] 72
RGPE-10?BRM?
1 19700 [5.8] 9500 [2.8]
36200 [10.6] 16.5 13
900 [425] 69
2 25100 [7.4] 11100 [3.3] 1225 [578] 72
RGPR-05?BMK?
1 19300 [5.7] 9500 [2.8]
35400 [10.4] 15.5 12
900 [425] 69
2 24200 [7.1] 11200 [3.3] 1200 [566] 72
RGPR-07?AMK?
1 19500 [5.7] 9500 [2.8]
35600 [10.4] 16 12.5
900 [425] 69
2 24400 [7.1] 11200 [3.3] 1200 [566] 72
RGPR-07?BRQ?
1 19300 [5.7] 9700 [2.8]
36000 [10.5] 16.5 13
875 [413] 69
2 24800 [7.3] 11200 [3.3] 1200 [566] 72
RGPR-10?BRM?
1 19700 [5.8] 9500 [2.8]
36000 [10.5] 16.5 12.5
925 [437] 69
2 24900 [7.3] 11100 [3.3] 1225 [578] 72
RGRM-04?MAE?
1 19300 [5.7] 9500 [2.8]
35200 [10.3] 15.5 11.5
925 [437] 69
2 24000 [7.0] 11200 [3.3] 1200 [566] 72
RGRM-06?MAE?
1 19500 [5.7] 9500 [2.8]
35200 [10.3] 15.5 11.5
900 [425] 69
2 23900 [7.0] 11300 [3.3] 1175 [554] 72
RGRM-07?MAE?
1 18500 [5.4] 9900 [2.9]
34600 [10.1] 15.5 12
800 [378] 69
2 22700 [6.7] 11900 [3.5] 1025 [484] 72
RGRM-07?YBG?
1 17600 [5.2] 10200 [3.0]
34400 [10.1] 16 12
700 [330] 69
2 22300 [6.5] 12100 [3.5] 975 [460] 72
RGRM-09?ZAJ?
1 19500 [5.7] 9500 [2.8]
35800 [10.5] 16 12
950 [448] 69
2 24700 [7.2] 11100 [3.3] 1225 [578] 72
RGRM-10?ZAJ?
1 19100 [5.6] 9700 [2.8]
35400 [10.4] 16 12.5
875 [413] 69
2 23900 [7.0] 11500 [3.4] 1150 [543] 72
RGTM-06?MAE?
1 19500 [5.7] 9500 [2.8]
35000 [10.3] 16 12.5
900 [425] 69
2 23100 [6.8] 11900 [3.5] 1025 [484] 72
RGTM-07?RBG?
1 19500 [5.7] 9500 [2.8]
36200 [10.6] 16 12.5
950 [448] 69
2 25300 [7.4] 10900 [3.2] 1275 [602] 72
RGTM-09?ZAJ?
1 20000 [5.9] 9400 [2.8]
36000 [10.5] 16 12.5
975 [460] 69
2 24900 [7.3] 11100 [3.3] 1225 [578] 72
ROCA-070E03
1 20100 [5.9] 9300 [2.7]
35800 [10.5] 16 12.5
1000 [472] 69
2 24600 [7.2] 11200 [3.3] 1200 [566] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling
Air
Performance Data
RASL- JEC Series
15
Outdoor
Unit
RASL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
037JEC
RCFL-H*3821
ROCA-070E04
1 20100 [5.9] 9300 [2.7]
35800 [10.5] 16 12.5
1000 [472] 69
2 24600 [7.2] 11200 [3.3] 1200 [566] 72
ROLA-070E03
1 19700 [5.8] 9500 [2.8]
35800 [10.5] 16.5 12.5
900 [425] 69
2 24500 [7.2] 11300 [3.3] 1175 [554] 72
ROLA-070E04
1 19700 [5.8] 9500 [2.8]
35800 [10.5] 16.5 12.5
900 [425] 69
2 24500 [7.2] 11300 [3.3] 1175 [554] 72
ROLA-115E05
1 19700 [5.8] 9500 [2.8]
36000 [10.5] 16.5 13
900 [425] 69
2 24800 [7.3] 11200 [3.3] 1200 [566] 72
RCFL-H*3821+RXMD-C06 Coil Only
1 18900 [5.5] 9500 [2.8]
35000 [10.3] 14 11.5
925 [437] 69
2 23500 [6.9] 11500 [3.4] 1125 [531] 72
RCFL-H*3824
RGFE-09?ZCM?
1 19100 [5.6] 9700 [2.8]
35800 [10.5] 16 12.5
875 [413] 69
2 24600 [7.2] 11200 [3.3] 1200 [566] 72
RGFE-10?ZCM?
1 19700 [5.8] 9500 [2.8]
35800 [10.5] 16.5 12.5
900 [425] 69
2 24700 [7.2] 11100 [3.3] 1225 [578] 72
RGFE-12?RCM?
1 19100 [5.6] 9700 [2.8]
36000 [10.5] 16.5 12.5
875 [413] 69
2 24900 [7.3] 11100 [3.3] 1225 [578] 72
RGFG-09?ZCM?
1 19100 [5.6] 9700 [2.8]
35800 [10.5] 16 12.5
875 [413] 69
2 24600 [7.2] 11200 [3.3] 1200 [566] 72
RGFG-10?ZCM?
1 19500 [5.7] 9500 [2.8]
35800 [10.5] 16 12.5
900 [425] 69
2 24600 [7.2] 11200 [3.3] 1200 [566] 72
RGFG-12?RCM?
1 19100 [5.6] 9700 [2.8]
36000 [10.5] 16.5 12.5
875 [413] 69
2 24900 [7.3] 11100 [3.3] 1225 [578] 72
RGGE-09?ZCM?
1 20200 [5.9] 9200 [2.7]
36000 [10.5] 16 12.5
1025 [484] 69
2 25000 [7.3] 11000 [3.2] 1250 [590] 72
RGGE-10?ZCM?
1 19100 [5.6] 9700 [2.8]
35800 [10.5] 16 12.5
875 [413] 69
2 24600 [7.2] 11200 [3.3] 1200 [566] 72
RGGE-12?RCM?
1 19100 [5.6] 9700 [2.8]
36000 [10.5] 16.5 13
875 [413] 69
2 24800 [7.3] 11200 [3.3] 1200 [566] 72
RGJF-09?ZCM?
1 20200 [5.9] 9200 [2.7]
36000 [10.5] 16 12.5
1025 [484] 69
2 25000 [7.3] 11000 [3.2] 1250 [590] 72
RGJF-10?ZCM?
1 19100 [5.6] 9700 [2.8]
35800 [10.5] 16 12.5
875 [413] 69
2 24600 [7.2] 11200 [3.3] 1200 [566] 72
RGJF-12?RCM?
1 19300 [5.7] 9700 [2.8]
36000 [10.5] 16.5 13
875 [413] 69
2 24800 [7.3] 11200 [3.3] 1200 [566] 72
RGLE-07?BRQ?
1 19700 [5.8] 9500 [2.8]
36000 [10.5] 16.5 13
925 [437] 69
2 24900 [7.3] 11100 [3.3] 1225 [578] 72
RGLE-10?BRM?
1 19300 [5.7] 9700 [2.8]
36000 [10.5] 16.5 13
875 [413] 69
2 24800 [7.3] 11200 [3.3] 1200 [566] 72
RGLE-12?ARM?
1 19700 [5.8] 9500 [2.8]
36200 [10.6] 16.5 13
925 [437] 69
2 25100 [7.4] 11100 [3.3] 1225 [578] 72
RGLR-07?BRQ?
1 19700 [5.8] 9500 [2.8]
36000 [10.5] 16.5 13
900 [425] 69
2 24900 [7.3] 11100 [3.3] 1225 [578] 72
RGLR-10?BRM?
1 19700 [5.8] 9500 [2.8]
36000 [10.5] 16.5 13
925 [437] 69
2 24800 [7.3] 11200 [3.3] 1200 [566] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions