SUBMITTAL SHEET FOR RHML
2 TO 5 NOMINAL TON [7.3 TO 17.6 kW] AIR HANDLERS
FEATURES FOR RHML
■ RHLA/RHLL models feature GEʼs new X-13 motor which provides
enhanced SEER performance with most manufacturerʼs outdoor units.
■ 1
1
/2 ton [5.3 kW] through 5 ton [17.6 kW] models are between 421/2 to
55
1
/2 inches [1080 to 1410 mm] tall and 22 inches [559 mm] deep.
■ Versatile 4-way convertible design for upflow, downflow, horizontal left and
horizontal right applications.
■ Factory-installed high efficiency indoor coil.
■ All models meet or exceed 330 to 400 CFM [156 to 189 L/s] per ton at .3
inches [.7 kPa] of external static pressure.
■ Enhanced airflow up to .7" external static pressure.
■ Sturdy construction with 1.0 inch [.24 kPa] of reinforced foil faced jacket
insulation for excellent thermal and sound insulation.
■ Field-installed auxiliary electric heater kits provide exact heat for indoor
comfort. Kits include circuit breakers which meet UL and cUL requirements for service disconnect.
■ The most compact unit design available, all standard heat air handler
models only 42
1
/2 to 551/2 inches [1079 to 1409 mm] high.
■ Attractive pre-painted cabinet exterior.
■ Rugged wall steel cabinet construction, designed for added strength and
versatility.
[ ] Designates Metric Conversions
UNIT DATA
COOLING PERFORMANCE
TOTAL CAPACITY*..................
_______
MBH [kW]
SENSIBLE CAPACITY*............
_______
MBH [kW]
OUTDOOR DESIGN TEMP. ....
_______
°F [°C] DB
TOTAL SUPPLY AIR ................
_______
CFM [L/s]
TEMP. OF AIR ENTERING
EVAPORATOR COIL............
_______
°F [°C] DB
_______
°F [°C] WB
POWER INPUT REQUIREMENT ........
_______
kW
(*uses blower motor heat)
HEATING PERFORMANCE
TOTAL CAPACITY*..................
_______
MBH [kW]
OUTDOOR DESIGN TEMP. ....
_______
°F [°C] DB
TEMP. OF AIR ENTERING
EVAPORATOR COIL............
_______
°F [°C] DB
ELECTRIC HEAT CAPACITY ............
_______
kW
POWER INPUT REQUIREMENT ........
_______
kW
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT......................................
_______
IWG
BLOWER SPEED ..........................
_______
RPM
POWER OUTPUT REQUIREMENT ..
_______
BHP
MOTOR RATING ........................
_______
HP [W]
POWER INPUT REQUIREMENT ........
_______
kW
ELECTRICAL DATA
POWER SUPPLY..................
______________ Hz
TOTAL UNIT AMPACITY................
_______
AMPS
MINIMUM WIRE SIZE ....................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ..........
_______
AMPS
CLEARANCES
SERVICE ACCESS FRONT 24" [609.6 mm]
FORM NO. X33-1394