
SALES FACT SHEET
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product which fails in
normal use and service within the applicable period stated, in accordance
with the terms of the limited warranty.
Indoor Coils leaks caused by factory defects . . . . . . . . . . . . . .Five (5) Years
Electric Heating Element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Five (5) Years
*Any Other Part . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Five (5) Years
*For complete details of the limited warranty, including applicable terms & conditions, see
your local installer or contact the manufacturer for a copy.
RHEEM AIR CONDITIONING DIVISION FORM NO. H11-523-SFS
5600 Old Greenwood Road, Fort Smith, Arkansas 72908 PRINTED IN U.S.A. DC 12-05
“CERTIFIED UNDER THE A.R.I. CERTIFICATION
PROGRAM—A.R.I. STANDARDS 210/240-84”
Features
■ Includes an energy efficient GE
®
ECM®Motor, which in
most applications, enhances the SEER rating of the outdoor unit. It also slowly ramps its speed up for quiet operation and enhanced customer satisfaction.
■ Versatile 4-way convertible design for upflow, downflow,
horizontal left and horizontal right applications.
■ Nominal airflow up to 1.0" external static pressure.
■ Factory-installed high efficiency indoor coil.
■ Sturdy cabinet construction with 1.0 inch [25.4 mm] of
foil faced insulation for excellent sound and insulating
characteristics.
■ Field-installed auxiliary electric heater kits provide exact
heat for indoor comfort. Kits include circuit breakers which
meet U.L. and cUL requirements for service disconnect.
■ Dip switch settings for selectable, customized cooling air-
flow over a wide variety of applications.
■ On-demand dehumidification terminal that adjusts airflow
to help control humidity for unsurpassed comfort in cooling mode.
Starting at:
Price $
RHKA- SERIES
featuring R-22 Refrigerant
RHKL- SERIES
featuring Earth-Friendly
R-410A Refrigerant
earth friendly refrigerant
R H K A 17 A
RHEEM CLASSIFICATION
H =
AIR HANDLER
K = PREMIUM REFRIGERANT
A = R-22
L = R-410A
—
HM
A/C OR HP
MULTI-
POSITION
(VERTICAL
UPFLOW/
HORIZONTAL
LEFT IS THE
FACTORY
CONFIGURATION)
A*
VARIATIONS
A = STANDARD
24 = 18,000/24,000 BTU/HR
36 = 30,000/36,000 BTU/HR
48 = 42,000/48,000 BTU/HR
60 = 60,000 BTU/HR
24 J
CAPACITY
[5.27/7.03 kW]
[6.79/10.55 kW]
[12.31/14.07 kW]
[17.58 kW]
CABINET
SIZE
17 = 17.5" [431.8 mm]
(800-1200 CFM)
21 = 21" [533.4 mm]
(1400-1600 CFM)
24 = 24.5" [609.6 mm]
(1600-1800 CFM)
VOLTAGE
J = 208/240/1/60
DESIGN
VARIATION
A = 1ST DESIGN