The latest EcoNet™ Control Center includes intuitive integrated air
and water control and supports new high-efficiency products.
Easy to Setup, Easy to Use,
Easy to Save
• Built with our 360°+1 design philosophy,
it is optimized for Installability
Integration & Serviceability
• Controls 65%
†
or more of a typical home’s
energy use from a single device
• Can reduce energy costs by up to 30%
™
, Performance,
††
Features
• Added support for EEV
(Electronic Expansion Valve) Air Handlers,
Air Conditioners and Heat Pumps
• Rapid installation with standard
4-wire configuration
• Automatically configures communicating
equipment with optimal settings
• Adapts to home décor through
interchangeable faceplates and
adjustable background coloring
• Full-color, 4.7" LCD touchscreen display
with easy-to-read icons and text
• Convenient date, time and indoor/outdoor
temperature indications
• 5 operating modes with short-cycle
protection (Heat, Cool, Auto, Emergency
Heat, Fan Only)
• 7-Day programmable schedule
with Smooth Arrival & Whole Home
Vacation options
• Detailed operating status, alarm history,
and audible alerts
• Supports humidifier accessories or
over-cool based dehumidification
• One-touch access to Water Heater
Management
†††
• Easily manage from anywhere in the world
with the compatible WiFi Module & EcoNet
app for smart phones and tablets
Limited Warranty
• 5-Year limited warranty from date
of installation
• If installed as part of a Rheem System,
the EcoNet Control Center will be covered
under the applicable product parts
warranty. Refer to manufacturer product
warranty card for specific details.
† Source – D epar tment of E nergy
†† When compared to non-programmable thermostats.
Source: EN ERGY STAR
††† Requi res wire d conne ction to EcoNet En abled E lectric or
Hybri d Water Hea ters
®
for Programmable Thermostats
EcoNet™ Control Center
Home control with intuitive LCD
touchscreen navigation
EcoNet Control Center Compatibility
OFFERINGSHEATING & COOLING
Product
Categories
ModelsR97V R96V R802V RHMV
RETST601SYS
Rheem Heating, Cooling & Water Heating
1100 Abernathy Road, Suite 1400 • Atlanta, GA 30328
www.rheem.com
Gas FurnacesAir HandlersAir ConditionersHeat Pumps
RH2T
(EEV)
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
RA20RA17RP20*RP17
INTEGRATED HOME COMFORT
WATER HEATING
WiFi Kit for HVAC
REWRA630 SYS
Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Electric
Tan k Mo d els
Ending in EC2
Brampton, Ontario • L6Y 0P5
PRINTED IN U.S.A. 4/16 QG FORM NO. C–RH-ECO-CCSS-15-1 Rev 2
Specially designed to work with Rheem Prestige
Series modulating gas furnaces. Plus, it’s designed
to be easy-to-view, easy-to-understand and easyto-operate with simple on-screen programming.
• Bright 12 square inch Touchscreen display
• Universal - Choice of 7 day, 5/1/1 day program-
mable, or non-programmable (Installer selectable)
• Armchair programming allows users to remove
STAGESSTAGESSTAGESAUTOREMOTEREMOTE
PART NOPROG(CONV)(HEAT PUMP)READYHEAT (HP/GAS)OVERFANSWITCHESSWITCHCONNECTIONSWxHxD (IN)INDOOROUTDOOR
Specifically designed for comfort and energy
savings with dual fuel split systems or Package
Dual Fuel models. Ships with outdoor temperature
sensor included.
• Bright 12 square inch Touchscreen display
• Universal - Choice of 7 day, 5/1/1 day program-
mable, or non-programmable (Installer selectable)
• Armchair programming allows users to remove
thermostat to set the schedule
• Keypad lockout options
• Easy, menu-driven programming
• Humidification and dehumidification controls
• Maintenance reminders
• Suitable for use with an indoor or outdoor sensor
• Compressor short cycle protection
• 5-year limited warranty
thermostat to set the schedule
• Keypad lockout options
• Dual-Powered - Choice of battery-
powered or hardwired with battery back-up
• Humidification and dehumidification controls
• Maintenance reminders
• Compressor short cycle protection
• 5-year limited warranty
STAGESSTAGESSTAGESAUTOREMOTEREMOTE
PART NOPROG(CONV)(HEAT PUMP)READYHEAT (HP/GAS)OVERFANSWITCHESSWITCHCONNECTIONSWxHxD (IN)INDOOROUTDOOR
Sensor Req EM Heat-Off ProgY,Y2,G,B,O,L,6,+,S,- 4-5/6x1-1/4
Sensor Req EM Heat-OffProg G,O/B,6,DHM,HM,+,S,- 4-5/6x1-1/4
• Keypad lockout options
• Maintenance reminders
• Suitable for use with an indoor or outdoor sensor
• Compressor short cycle protection
• 5-year limited warranty
• Additional feature for RHC-TST305UNMS only:
– Humidification and dehumidification controls
Rheem 200 Series Programmable
• Lighted 4 square inch blue display
• Fast and easy to program
• Permanent program retention
• Easy to wire terminal block
• Compressor short cycle protection
• 5-year limited warranty
STAGESSTAGESAUTO
PART NOPROG(CONV)(HEAT PUMP)OVERFANSWITCHESSWITCHCONNECTIONSWxHxD (IN)
RHC-TST211GESS5/2, 5/1/11H/1CN/AYesNoCool-Auto-Heat-OffOn-AutoRc,Rh,C,W,Y,G,O/B5-1/8 x 3-7/8 x 1-1/4
RHC-TST213UNMS5/1/12H/2C3H/2CYesNoCool-Auto-Heat-EM Heat-OffOn-AutoRH,RC,C,E/W1,W2,G,Y1,Y2,O,B,L5-1/8 x 3-7/8 x 1-1/4
8WWW.RHEEMPARTS.COM WWW.RUUDPARTS.COM
HEAT/COOLHEAT/COOLCHANGEPROGSYSTEMFANSIZE
Page 5
INTEGRATED CONTROLS
UETST601SYS
THE LATEST ECONET™ CONTROL CENTER INCLUDES INTUITIVE INTEGRATED
AIR AND WATER CONTROL AND SUPPORTS NEW HIGH-EFFICIENCY
PRODUCTS.
EASY TO SETUP, EASY TO USE,
EASY TO SAVE
• Built with our 360°+1 design philosophy,
it is optimized for Installability
Integration & Serviceability
• Controls 65%
†
or more of a typical home’s
energy use from a single device
• Can reduce energy costs by up to 30%
™
, Performance,
††
FEATURES
• Added support for new EEV (Electronic
Expansion Valve) Air Handlers,
Air Conditioners and Heat Pumps*
• Rapid installation with standard
4-wire confi guration
• Automatically confi gures communicating
equipment with optimal settings
• Adapts to home décor through
interchangeable faceplates and
adjustable background coloring
• Full-color, 4.7" LCD touchscreen display
with easy-to-read icons and text
• Convenient date, time and indoor/outdoor
temperature indications
• 5 operating modes with short-cycle
protection (Heat, Cool, Auto, Emergency
Heat, Fan Only)
• 7-Day programmable schedule with Smooth
Arrival & Whole Home Vacation options
• Detailed operating status, alarm history,
and audible alerts
• Supports humidifi er accessories or
over-cool based dehumidifi cation
• One-touch access to Water
Heater Management
†††
• Easily manage from anywhere in the world
with the compatible WiFi Module & EcoNet
app for smart phones and tablets
LIMITED WARRANTY
• 5-Year limited warranty from
date of installation
• If installed as part of a Ruud System,
the EcoNet Control Center will be covered
under the applicable product parts
warranty. Refer to manufacturer product
warranty card for specifi c details.
† Source – Department of Energy
†† When compared to non-programmable thermostats.
Source: ENERGY STAR
††† Requires wired connection to EcoNet Enabled Electric or
Hybrid Water Heaters
®
for Programmable Thermostats
econet™ control center
Home control with intuitive LCD
touchscreen navigation
ECONET CONTROL CENTER COMPATIBILITY
OFFERINGSHEATING & COOLING
Product
Categories
ModelsU97V U96V U802V RHMV
UETST601SYS
Ruud Heating, Cooling & Water Heating
1100 Abernathy Road, Suite 1400 • Atlanta, GA 30328
www.ruud.com
Gas FurnacesAir Handlers
RH2T
(EEV)
In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice.
Air
Conditioners
UA20 UA17 UP20* UP17
Heat Pumps
WiFi Kit
for HVAC
REWRA630SYS
Ruud Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Electric Tank
Models
Ending in EC2
PRINTED IN U.S.A. 4/16 QG FORM NO. C-RU-ECO-CCSS-15-1 Rev 2
WATER HEATING
Hybrid Tank
HB50 Models
Gas Powered Damper
Tank Models
*Av a ila ble i n 2016
Brampton, Ontario • L6Y 0P5
Rely on Ruud.
™
Page 6
N
D
™
L
G
T
elod
o
e
C
c
H F
t
e
C C
y
J
J
C
noo
C &
J
M
P
VA H
f
M
k
T
M
W
C
r
™
o
C
s
S
s
r
S
r
d
e
l
C
N
E
m
rt
Cl
t
y
C
r
evlan Voisnapxc EinortceEl
sledo) MVEE (
c.duuR
delEnabteNocE/moc
OCE
ET
EDIU
ORP
E SCTU
NOICTE
NoE
latsn
iuqe
tno
r
om Cetarepo od ter
pm
H
V
r
omC2 CC026NRTEe Rhf tn ooital
lorton
r
n
2
met
dog mnitacinummoy cllun a fr ietnel Co
w
oc
orntot CeNoce EhT
C
tsg synitaer HetaW
og mnitacinummoc
s ledop mmut PaeH
oo wslt a. IreldnaH
i
2
lort
or
no
e
oodtue ohn tr ootalsnar T™met
u
ledop mmut Paed Hnr aenoitidnor Ci A
(
d Felbant EeNoch Etid wehctan meh
of cb oue hhs ts aevrer sente
e atarepo od teriuqes rd in, asm
apmos cr ientel Corntoe Ch. Te
r UV o69h a Utd wiehctan mehw
c irtceld Eelbant EeNoch Ets wik
d is raol bortnos c’tin
.sreldnar Hir As oecanru
r
mCoh te wilbit
ad Tirbyd Hna
en
H
y
g
t eNocn Eh ati) wCEJ****
nitaes H’emor a hon foitacinum
nitaed Helbant EeNocn E
g &
2
l
n
™
m
Hr a R, oecanrus FaV G280
o
r Hetae Wp
.sretae
n
dng aniloo, Cg
yllun a fm ietsg syniloo
dn arenioitdn Cori A
r) Ai*VEET (2Hr R
*
EcoNet Mobile
iFi KitEcoNet WApp
oNet Control Cente
Page 7
o
t
t
W
o
o
E
r
T
r
a
s
f
S
o
n
H
T
s
e
n
o
c
g
f
N
T
S
W
d
w
a
y
e
yq
d
W
W
A
W
c
o
n k
M
i
E
T
g
y o
s p
M
k
T
w
P
e
, R
u
e
A
0
gg
g
eét
/Ldt Ladaan CduuR
eoNcE
e
ss utii KFit WeNocE
rnt fempiuqd eelbanE
stii KFi
wtes nselers wi'renwoemoe hh
trob pey wldneirf-eliboe mhm t
.sppe alibod mnl aa
not cenrentd Inabdaord bnk ar
arepe otomee rlbano en toitcen
t eNocf En ooit
r ot fii KFiW
f
ad Tirbyr Hc oirtcel
od Cng aniateH
e Wp
gnil
s rt iii KFiS WYS036ARWe REh
dnl aatrob pet weNoce Ehm to
ce Etarepy oletomeo rd teriuqe
036ARWe REh. Tpspe alibo m
t orae py bat mahs tretaer Het
t
iloog & Cnitaed Helbant EeN
och Ete wilbitapmoo csls aS iY
noitulot srofmoe cmol hatoe th
.
s metsg sy
d elbant EeN
SY0S36AWRER
r ot fii KFiW
T
ad Tirby
bd Hync airctelE
i
s t iii KFiWH WE136ARWEe Eh
retaer Hetae Wp
f
reater He
cl Eorntoy cletomeo rd teriuqer
l aatrob pet weNoce Ehm tor
.pspe alibod m
d nc airtceld Eelbant EeN
HEW136AREWE
r ot fii KFiW
aG
t
ater He
sr
t iii KFiWH WG136ARWEe Eh
nk W
epmad Derewoe Pp
os Pad Gelbant EeNocEe:to
nl aatrob pet weNoce Ehm tor
m
ar Tepmad Dere
l Eorntoy cletomeo rd teriuqes r
b pet weNocm Eors fretaer Het
tae Wp
ehm tort fod nn, apspe alibo
nk as Tad Gelbant EeNo
.pspe alibod mnl aatro
essecce ay bnln oas cretaer H
.rentel Corntot CeNoc E
HWG316ARWEE
g
E
E
I
4e 1tiu, Sdaoy Rhtanreb0 A011
M
Eg
h itig wnipe
r etag & Wniloo, Cgnitaed HuuR
nitaeH
H Ty
n
g
ilo
8230A 3, Gatnalt0 • A
s puounitnof c
cud
d pns aser
D
:
ETON
nnahe claselohw
d ruu
nem
p
res
mhge rhs t
ohtis wegnahe cka
, Udaoe Rrawegd5 E21
. ecitot n
e ho tc tfiicepe srs arebmul nedol ml
. r
fiy das mrebmul nedol miate. Rl
.
5PY O6o • Liratn, Onotpmart 1 • Bin
Page 8
RUUD THERMOSTATS
Ruud 400 Series Touchscreen – Modulating Furnace
Specially designed to work with Rheem Prestige
Series modulating gas furnaces. Plus, it’s designed
to be easy-to-view, easy-to-understand and easyto-operate with simple on-screen programming.
• Bright 12 square inch Touchscreen display
• Universal - Choice of 7 day, 5/1/1 day program-
mable, or non-programmable (Installer selectable)
• Armchair programming allows users to remove
STAGESSTAGESSTAGESAUTOREMOTEREMOTE
PART NOPROG(CONV)(HEAT PUMP)READYHEAT (HP/GAS)OVERFANSWITCHESSWITCHCONNECTIONSWxHxD (IN)INDOOROUTDOOR
Specifically designed for comfort and energy
savings with dual fuel split systems or Package
Dual Fuel models. Ships with outdoor temperature
sensor included.
• Bright 12 square inch Touchscreen display
• Universal - Choice of 7 day, 5/1/1 day program-
mable, or non-programmable (Installer selectable)
• Armchair programming allows users to remove
thermostat to set the schedule
• Keypad lockout options
• Easy, menu-driven programming
• Humidification and dehumidification controls
• Maintenance reminders
• Suitable for use with an indoor or outdoor sensor
• Compressor short cycle protection
• 5-year limited warranty
thermostat to set the schedule
• Keypad lockout options
• Dual-Powered - Choice of battery-powered or
hardwired with battery back-up
• Humidification and dehumidification controls
• Maintenance reminders
• Compressor short cycle protection
• 5-year limited warranty
STAGESSTAGESSTAGESAUTOREMOTEREMOTE
PART NOPROG(CONV)(HEAT PUMP)READYHEAT (HP/GAS)OVERFANSWITCHESSWITCHCONNECTIONSWxHxD (IN)INDOOROUTDOOR
Sensor Req EM Heat-Off ProgY,Y2,G,B,O,L,6,+,S,- 4-5/6x1-1/4
Sensor Req EM Heat-OffProg G,O/B,6,DHM,HM,+,S,- 4-5/6x1-1/4
• Keypad lockout options
• Maintenance reminders
• Suitable for use with an indoor or outdoor sensor
• Compressor short cycle protection
• 5-year limited warranty
• Additional feature for RHC-TST305UNMS only:
– Humidification and dehumidification controls
Ruud 200 Series Programmable
• Lighted 4 square inch blue display
• Fast and easy to program
• Permanent program retention
• Easy to wire terminal block
• Compressor short cycle protection
• 5-year limited warranty
STAGESSTAGESAUTO
PART NOPROG(CONV)(HEAT PUMP)OVERFANSWITCHESSWITCHCONNECTIONSWxHxD (IN)
UHC-TST211GESS5/2, 5/1/11H/1CN/AYesNoCool-Auto-Heat-OffOn-AutoRc,Rh,C,W,Y,G,O/B5-1/8 x 3-7/8 x 1-1/4
UHC-TST213UNMS5/1/12H/2C3H/2CYesNoCool-Auto-Heat-EM Heat-OffOn-AutoRH,RC,C,E/W1,W2,G,Y1,Y2,O,B,L5-1/8 x 3-7/8 x 1-1/4
12WWW.RHEEMPARTS.COM WWW.RUUDPARTS.COM
HEAT/COOLHEAT/COOLCHANGEPROGSYSTEMFANSIZE
Page 9
EMERSON (WHITE-RODGERS) THERMOSTATS
Sensi WiFi Thermostat
The Sensi WiFi Programmable Thermostat
provides control of home comfort - anytime and
anywhere from a smartphone, tablet or PC. The
FREE Sensi App connects the Sensi thermostat
to a home WiFi router. No more wasteful heating
or cooling an empty home. Includes 5-year
limited warranty with the professional installation.
• Easy to install
– No “C wire” require for most applications.
(Required for heat only/cool only systems)
– Traditional wire and configure installation
STAGESSTAGESSTAGESAUTOINDOOROUTDOOR
PART NOPROG(CONV)(HEAT PUMP)READYHEAT (HP/GAS) OVERFANSWITCHESSWITCHCONNECTIONSWxHxD (IN)SENSORSENSOR
1F86U-42WF72H/2C4H/2C——YesNo Cool-Auto-Heat-On-AutoRc,Rh,C,W/E,5-7/8 x 3-3/4 x 1-1/4——
feature saves energy during
peak A/C demand periods
• Compressor short cycle protection
• 5-year limited warranty
4-13/16 x 3-13/16 x 1-1/2
4-13/16 x 3-13/16 x 1-1/2
Classic 80 Series Programmable
• Lighted digital display
• Fast and easy to program
• Compressor short cycle protection
STAGESSTAGESAUTO
PART NOPROGRAMMING(CONV)(HEAT PUMP)OVERPROG FANSWITCHESFAN SWITCHCONNECTIONSSIZE WxHxD (IN)
1F85-2777, 5/1/12H/2C3H/2CYesNo
HEAT/COOLHEAT/COOLCHANGESYSTEM
Cool-Auto-Heat-EM Heat-Off
• Easy to wire terminal block
• Permanent program retention
• 5-year limited warranty
On-AutoR,C,E/W1,W2,G,Y1,Y2,O,B,L6-1/8 x 3-3/4 x 1-1/4
Classic 80 Series Non-Programmable
• Lighted digital display
• Easy to wire terminal block
• Compressor short cycle protection
• 5-year limited warranty
STAGESSTAGESAUTO
PART NOPROGRAMMING(CONV)(HEAT PUMP)OVERPROG FANSWITCHESFAN SWITCHCONNECTIONSSIZE WxHxD (IN)
1F86-241None1H/1C1H/1CNoNoCool-Off-HeatOn-AutoR,C,W2,Y,G,B/O,E,L6-1/8 x 3-3/4 x 1-1/4
HEAT/COOLHEAT/COOLCHANGESYSTEM
15THERMOSTATS & ALARMS
Page 12
EMERSON (WHITE-RODGERS) THERMOSTATS
New 80 Series Programmable
• Large bright backlight digital display with high
contrast screen
• Slim profile and modern design
• Compressor short cycle protection
• 5-year limited warranty
STAGESSTAGESAUTO
PART NOPROGRAMMING(CONV)(HEAT PUMP)OVERPROG FANSWITCHESFAN SWITCHCONNECTIONSSIZE WxHxD (IN)
1F83C-11PR7, 5/1/11H/1C1H/1CNoNoCool-Off-HeatOn-AutoRc,Rh,C,W,Y,O/B,G6 x 3-3/4 x 1-1/8
1F83H-21PR7, 5/1/1— 2H/1CNoNoCool-Heat-EM Heat-OffOn-AutoR,C,W2,E,Y,O/B,G,L6 x 3-3/4 x 1-1/8
1F85U-22PR7, 5/1/12H/2C2H/1CYesNoCool-Auto-Heat-EM Heat-OffOn-AutoRc,Rh,C,W/E,W2,Y,Y2,O/B/6,G,L6 x 3-3/4 x 1-1/8
1F85U-42PR7, 5/1/12H/2C4H/2CYesNoCool-Auto-Heat-EM Heat-OffOn-AutoRc,Rh,C,W/E,W2,Y,Y2,O/B/6,G,L6 x 3-3/4 x 1-1/8
PART NOPROGRAMMING(CONV)(HEAT PUMP)OVERPROG FANSWITCHESFAN SWITCHCONNECTIONSSIZE WxHxD (IN)
1F83H-21NPNone— 2H/1CNoNoCool-Heat-EM Heat-OffOn-AutoR,C,W2,E,Y,O/B,G,L6 x 3-3/4 x 1-1/8
1F85U-22NPNone2H/2C2H/1CYesNoCool-Auto-Heat-EM Heat-OffOn-AutoRc,Rh,C,W/E,W2,Y,Y2,O/B/6,G,L6 x 3-3/4 x 1-1/8
1F85U-42NPNone2H/2C4H/2CYesNoCool-Auto-Heat-EM Heat-OffOn-AutoRc,Rh,C,W/E,W2,Y,Y2,O/B/6,G,L6 x 3-3/4 x 1-1/8
HEAT/COOLHEAT/COOLCHANGESYSTEM
New 80 Series Programmable
• Large bright backlight digital display with high
contrast screen
• Slim profile and modern design
• Compressor short cycle protection
• 5-year limited warranty
STAGESSTAGESAUTO
HEAT/COOLHEAT/COOLCHANGESYSTEM
70 Series Programmable
• Digital display
• Economical upgrade to digital accuracy and
energy savings
• Easy to use
• Footprint covers wall marks of most
STAGESSTAGESAUTO
PART NOPROGRAMMING(CONV)(HEAT PUMP)OVERPROG FANSWITCHESFAN SWITCHCONNECTIONSSIZE WxHxD (IN)
1F78-1515/21H/1C1H/1CNoNoCool-Off-HeatOn-AutoRh,Rc,G,W,Y,O,B5-1/8 x 3-3/4 x 1-1/8
HEAT/COOLHEAT/COOLCHANGESYSTEM
mechanical thermostats
without additional wall plate
• Compressor short cycle protection
• 5-year limited warranty
70 Series Non-Programmable – Horizontal
• Digital display
• Economical upgrade to digital accuracy and
energy savings
• Easy to use
• Footprint covers wall marks of most
STAGESSTAGESAUTO
PART NOPROGRAMMING(CONV)(HEAT PUMP)OVERPROG FANSWITCHESFAN SWITCHCONNECTIONSSIZE WxHxD (IN)
1F78-144None1H/1C1H/1CNoNoCool-Off-HeatOn-AutoRh,Rc,G,W,Y,O,B5-1/8 x 3-3/4 x 1-1/8
1F79-111NoneN/A2H/1CNoNoCool-Off-Heat-EM HeatOn-AutoR,C,W2,Y,G,O/B,E,L5-1/8 x 3-3/4 x 1-1/8
HEAT/COOLHEAT/COOLCHANGESYSTEM
mechanical thermostats
without additional wall plate
• Compressor short cycle protection
• 5-year limited warranty
16WWW.RHEEMPARTS.COM WWW.RUUDPARTS.COM
Page 13
EMERSON (WHITE-RODGERS) THERMOSTATS
70 Series Non-Programmable – Vertical
• Digital display
• Economical upgrade to digital accuracy and
energy savings
• Easy to use
STAGESSTAGESAUTO
PART NOPROGRAMMING(CONV)(HEAT PUMP)OVERPROG FANSWITCHESFAN SWITCHCONNECTIONSSIZE WxHxD (IN)
1E78-140None1H/0C—No—On-Off—Rh, W3-3/16 x 5-5/16 x 1-1/8
1E78-144None1H/1C1H/1CNo—Cool-Off-HeatOn-AutoRc,Rh,G,W,Y,B,O3-3/16 x 5-5/16 x 1-1/8
HEAT/COOLHEAT/COOLCHANGESYSTEM
Mechanical (Mercury Free) Thermostats
• Mercury free replacement for hundreds of
White-Rodgers and competitive models
installed during the past 50 years
• Enclosed contacts for increased reliability and
accuracy
STAGESSTAGESAUTO
PART NOPROGRAMMING(CONV)(HEAT PUMP)OVERPROG FANSWITCHESFAN SWITCHCONNECTIONSSIZE WxHxD (IN)
1E56N-444None1H/1C1H/1CNoNoCool-Off-HeatOn-AutoRc,Rh,W,Y,G,O,B,A3-1/4 x 4-1/2 x 1-5/8
1F56N-444None1H/1C1H/1CNoNoCool-Off-HeatOn-AutoRc,Rh,W,Y,G,O,B,A4-1/2 x 3-1/4 x 1-5/8
HEAT/COOLHEAT/COOLCHANGESYSTEM
• Compressor short cycle
protection
• 5-year limited warranty
• Includes terminal wallplate for
3-wire zone valve applications
• Available in both horizontal (1F56N-444) and
vertical (1E56N-444) configurations
• 5 Year limited warranty
PRO1 THERMOSTATS
Contractors demand quality, reliability, and
availability. Homeowners want an easy to use
thermostat with premium styling and large displays.
The Pro1 thermostats are designed to satisfy these
heavy duty demands. They provide a great value
and are exclusive to the HVAC industry.
• Dual powered – choice of battery-powered or
hardwired with battery back-up
• One Size Thermostats – All Pro1 thermostats
have the same size footprint, so you’ll never have
to worry about wall marks left by older designs;
you can also upgrade to new models without
replacing the subbase
PRO1 WIFI THERMOSTATS
T855i Programmable WiFi
• Control and monitor the HVAC system’s
performance from anywhere
• Active alerts send notification to smart device if
the system is not working correctly
• Easy setup; quickstart guide walks
homeowner through the WiFi linking procedure
STAGESSTAGESSTAGESAUTO
PART NOIDENTIFIERPROG(CONV)(HEAT PUMP)READYHEAT (HP/GAS)OVERFANSWITCHESSWITCHCONNECTIONSWxHxD (IN)QTYREQ
HEAT/COOL HEAT/COOLDUEL FUELDUEL FUELCHANGEPROGSYSTEMFANSIZECASE CASE
Gas as Auxilary Heat OnlyEM Heat-OffW/E,W2,G,Y1,Y2
• Innovative Dealer Badge System -
Private labeling for dealers has
never been easier. The magnetic badge is
universal for all Pro1 models. Go to
www.rheemparts.com or www.ruudparts.com for
more details and a copy of the “Private Label
Program Order Form”
• Color coded terminal blocks to help identify
terminals
• Glow in the dark light button
• Compressor short cycle protection due to user
inputs
• 5-year limited warranty
• Smart grid capable; works with
many utility incentive programs
• Bright 8 square inch LCD display
• Universal - Choice of 7 day, 5/1/1 day
programmable, or non-programmable
• Armchair programming
4-3/4 x 4-7/16 x 1-1/4
10Yes
17THERMOSTATS & ALARMS
Page 14
PRO1 THERMOSTATS
PRO1 WIFI THERMOSTATS
T701i WiFi
• Low cost basic WiFi option; programmable
through app only
• Control and monitor the HVAC system’s
performance from anywhere
• Active alerts send notification to smart device if
the system is not working correctly
STAGESSTAGESSTAGESAUTO
PART NOIDENTIFIERPROG(CONV)(HEAT PUMP)READYHEAT (HP/GAS)OVERFANSWITCHESSWITCHCONNECTIONSWxHxD (IN)QTYREQ
Construction thermostats are a low cost, nonadjustable, temporary thermostat preset to a
given temperature.
• Reduces fuel bills during the construction
process; no more high fuel bills caused by
construction workers turning up the
thermostat and leaving
• Rugged construction; not affected by heat,
moisture, paint and drywall dust
• Mercury-free
Temp-Stat Construction Thermostats
Rated 24VAC, 1A
PART NODESCRIPTIONCASE QTY CASE REQ
CL-70Temporary Construction Thermostat - Cooling Only - 70F10Yes
TS-41Temporary Construction Thermostat - Heating Only - 41F10Yes
TS-50Temporary Construction Thermostat - Heating Only - 50F10Yes
TS-60Temporary Construction Thermostat - Heating Only - 60F10Yes
TS-65Temporary Construction Thermostat - Heating Only - 65F10Yes
TS-70Temporary Construction Thermostat - Heating Only - 70F10Yes
TS-75Temporary Construction Thermostat - Heating Only - 75F10Yes
ICM Construction Thermostats
Rated 24VAC, 2A
PART NODESCRIPTIONCASE QTY CASE REQ
41-ICMSC055Temporary Construction Thermostat - Cooling Only - 55F10Yes
THERMOSTAT ACCESSORIES
THERMOSTAT GUARDS
F29-0143
These durable poly guards are designed for use
in offices, churches, restaurants, and other
public areas to prevent adjustment of the
thermostat by unauthorized personnel.
• Clear plastic keeps thermostat visible
PART NOLENGTH (IN) HEIGHT (IN) DEPTH (IN)COVER MATERIAL
F29-01436-3/83-1/23Clear Plastic
• Can be mounted vertically or
horizontally
• Includes options for both ring mount or solid
plate mount
• Furnished with one key
F29-0222
These durable metal guards are designed for
government, military, industrial, and education
applications to prevent adjustment of the
thermostat by unauthorized personnel.
PART NOLENGTH (IN) HEIGHT (IN) DEPTH (IN)COVER MATERIAL
F29-02226-5/84-1/23-3/8Metal - 18 guage
• Beige enamel finish over heavy-
duty steel enclosure
• Can be mounted vertically or horizontally
• Furnished with one key
T150
Pro1’s commercial strength locking thermostat
cover guard; can be installed without removing
the existing thermostat; ideal for high traffic areas.
PART NOLENGTH (IN) HEIGHT (IN) DEPTH (IN)COVER MATERIAL
F29-02226-3/452-3/8Clear Plastic
• Clear plastic keeps thermostat
visible
• Furnished with one key
24WWW.RHEEMPARTS.COM WWW.RUUDPARTS.COM
Page 21
THERMOSTAT ACCESSORIES
WALL PLATES
RETSTWPLWHT EcoNet Wall Plate
PART NOHEIGHT (IN) WIDTH (IN)COLORDESCRIPTION
RETSTWPLWHT56-5/8WhiteFits all EcoNet control centers
F61-2301
PART NOHEIGHT (IN) WIDTH (IN)COLORDESCRIPTION
F61-23015-5/85-3/4WhiteIncludes adapter for mounting to vertical junction box
F61-2500
PART NOHEIGHT (IN) WIDTH (IN)COLORDESCRIPTION
F61-25004-5/87-5/8WhiteFits all 80 Series Emerson/White-Rodgers models except Blue models
F61-2252
PART NOHEIGHT (IN) WIDTH (IN)COLORDESCRIPTION
F61-22525-5/85-3/4BeigeFits all 1F90 and 1F70 Emerson/White-Rodgers models
F61-2300
PART NOHEIGHT (IN) WIDTH (IN)COLORDESCRIPTION
F61-23007-1/45-1/2WhiteFits all 1F90 Emerson/White-Rodgers models except Blue models
F61-2510
PART NOHEIGHT (IN) WIDTH (IN)COLORDESCRIPTION
F61-25106-1/24-1/2WhiteFits all F70 Emerson/White-Rodgers models.
Includes adapter for mounting to horizontal or vertical junction box
F61-2550
PART NOHEIGHT (IN) WIDTH (IN)COLORDESCRIPTION
F61-25506-1/24-1/2WhiteFits all F70 Emerson/White-Rodgers models
F61-2600
PART NOHEIGHT (IN) WIDTH (IN)COLORDESCRIPTION
F61-26008-1/85-3/8WhiteFits 90 Series Blue Emerson/White-Rodgers models.
For use with or without horizontal junction box.
25THERMOSTATS & ALARMS
Page 22
THERMOSTAT ACCESSORIES
WALL PLATES
F61-2634
PART NOHEIGHT (IN) WIDTH (IN)COLORDESCRIPTION
F61-263456-1/2WhiteFits 90 and 80 Series Blue Emerson/White-Rodgers models.
PD411073 (T119)
PART NOHEIGHT (IN) WIDTH (IN)COLORDESCRIPTIONCASE QTY CASE REQ
PD4110735-1/27-1/2WhiteFits all Pro1 IAQ models5Yes
50028399-001
PART NOHEIGHT (IN) WIDTH (IN)COLORDESCRIPTION
50028399-0015-1/27-7/8WhiteFits Honeywell THX9000 series high definition thermsotats.
EMERSON (WHITE-RODGERS) REMOTE TEMPERATURE SENSORS
F1451328 Indoor Sensor
• For use with all Emerson (White-Rodgers)
thermostats with remote sensor capability
• Classic white color
For use with or without horizontal junction box.
Includes bracket for mounting to 2 in. x 4 in. juction box.
• Digital signal output provides
superior temperature control
• Works with a maximum 300 foot wire run
PART NODESCRIPTION
F1451328Remote Indoor Sensor
F1451378 Outdoor Sensor
• For use with all Emerson (White-Rodgers)
thermostats with remote sensor capability
• Classic white color
PART NODESCRIPTION
F1451378Remote Outdoor Sensor
• Digital signal output provides
superior temperature control
• Works with a maximum 300 foot wire run
F145RF-1600 Wireless Indoor/Outdoor Sensor
• 1F98EZ-1621 accepts up to three remote
sensors configured as indoor sensors and one
remote sensor configured as an outdoor
Wirelessly senses outdoor temperature and
humidity to display on compatible RedLINK™
enabled thermostats and accessories, include
HD Prestige™
PART NODESCRIPTION
C7089R1013Remote Outdoor Sensor
• In Non-Zoned Applications:
– Take anywhere in the home to sense and
control temperature from the room that you
are in
• In Zoned Applications:
– View and adjust all RedLINK™ enabled
thermostats from a single control
– Controls up to 16 thermostats
• Installs in minutes
• Up to 5-year battery life
• Includes two AA lithium batteries and
mounting hardware
PRO1 WIRELESS ACCESSORIES
Pro1 W150W Wireless Repeater
The wireless repeater extends the signal range
of Pro1 wireless devices. When W150W receives
a coded wireless signal, it repeats it to extend
the wireless range of the device. Extends range
PART NODESCRIPTION
W150WWireless Repeater
up to 100 feet with no
obstructions, and 50 feet in standard residential
construction. Requires 24VAC power source.
Pro1 WW160W “Wireless Wire”
Wireless Wire®replaces 24V control wiring.
Simply connect the terminals on one module,
and when those terminals see 24V, the corresponding terminals on the other module close.
• Wireless connect up to 2H/2C conventional or
PART NODESCRIPTIONCASE QTY CASE REQ
PD411086“Wireless Wire” Wire Extender5Yes
3H/2C heat pump systems
• Add wires to a condensing unit
• Wireless range up to 100 feet unobstructed
and up to 50 feet in standard residential
construction
28WWW.RHEEMPARTS.COM WWW.RUUDPARTS.COM
Page 25
THERMOSTAT ACCESSORIES
FAST-STAT WIRE EXTENDERS
For over 15 years now, FAST-STAT wiring
extenders have eliminated the need to re-pull
thermostat and condenser cables when adding
or upgrading HVAC equipment. FAST-STAT provides a significant savings in installation costs. A
new system can be wired in about 20 minutes.
• Designed to have a minimum service life of 50
years; limited lifetime free replacement
warranty
•
Suitable for up to 300 ft. between sender and
receiver (when using 18 AWG cable)
• No batteries required
• Common applications include:
– Adding 2-stage heating
– Adding single or 2-stage cooling
– Heat pump conversion
– Upgrading PTACs
– Upgrading RTUs
Connect the sender
to the existing
thermostat. The sender
is then installed into the
wall space behind the
thermostat.
All FAST-STAT models
require a minimum of
two wires between te
sender and receiver.
Install the receiver
at the furnace, fan-
coil, heat pump,
PTAC or RTU.
Extra wires
can be used
for other
functions.
FAST-STAT 1000 Wire Extender
(Provides One Additional Wire to a Cable)
Model 1000 provides one additional conductor to a thermostat or condenser cable. For instance, with a
2-wire cable it can provide “R”, “W”, plus one of “G”, “Y”, “H”, “D”, “W2”or “Y2” and with a 4-wire cable
it could provide “R”, “W”, “Y”, “G”, plus any one of “C”, “D”, “W2”, “Y2” or “O/B”. Common uses include
adding manual fan control “G” to a heating system, installing a powered thermostat that requires a
common connection “C”, or upgrading to 2-stage cooling and providing “Y2” to the condenser.
PART NOPOWER INPUT (VAC) NO OF CONTACTSCONTACT CONFIGCONTACT RATING (VAC)CONTACT RATING (A)
100018-302NO242
FAST-STAT 3000 Wire Extender (Provides 4-Wire Control Over a 2-Wire Cable)
Model 3000 provides 4-wire control over 2-wire cable or 6-wire control over a 4-wire cable. With a 2wire cable it can provide “R”, “W”, “G” and “Y”. With a 4-wire cable it can provide “R”, “W”, “Y”, “G”,
plus any two of “C”, “D”, “W2”, “Y2” or “O/B”. Common uses include adding air conditioning to a
heating system. Can also be used for heat pumps, 2-stage heating or cooling when an existing 4-wire
thermostat cable is present.
PART NOPOWER INPUT (VAC) NO OF CONTACTSCONTACT CONFIGCONTACT RATING (VAC)CONTACT RATING (A)
300020-303NO242
FAST-STAT 5000 Wire Extender (Provides 6-Wire Control Over a 2-Wire Cable)
Model 5000 provides 6-wire control over 2-wire cable or 8-wire control over a 4-wire cable. With a 2wire cable it can provide “R”, “C”, “W1”, “W2”, “G” and “Y”. With a 4-wire cable it can provide “R”, “C”,
“W1”, “W2”, “G” and “Y”, plus any other two functions such as “H”, “D”, “W2”, “Y2” or “O/B”.Common
uses include adding air conditioning to a heating system or installation of a 2-stage furnace. Can also be
used for heat pumps, 2-stage heating or cooling when an existing 4-wire thermostat cable is present.
PART NOPOWER INPUT (VAC) NO OF CONTACTSCONTACT CONFIGCONTACT RATING (VAC)CONTACT RATING (A)
500020-304NO242
FAST-STAT 7000 Wire Extender (For Converting AC to HP)
Model 7000 provides 7-wire control from the thermostat to the furnace or fan-coil over a 4-wire cable. This
includes “R”, “C”, “G”, “W”, “Y1”, “Y2” and “O/B”. From the furnace or fan-coil to the heat pump it provides
6-wire control over a 2-wire cable. This includes “R”, “C”, “Y1”, “Y2”, “O/B” and “W” (defrost).Common uses
include converting from an air conditioning to a heat pump (single or 2-stage) system.
PART NOPOWER INPUT (VAC) NO OF CONTACTSCONTACT CONFIGCONTACT RATING (VAC)CONTACT RATING (A)
700020-305NO242
29THERMOSTATS & ALARMS
Page 26
THERMOSTAT ACCESSORIES
FAST-STAT WIRE EXTENDERS
FAST-STAT 9000 Wire Extender (For Converting AC to 1 or 2-Stage HP)
Model 9000 mounts between the control board on the indoor unit and the outdoor unit. Provides 2-stage
air conditioning or heat pump control over the existing 2-wire condenser cable. It is designed to reduce
installation time when converting from an air conditioner to a heat pump (single or 2-stage) system. It can
also interact with Zone Controllers made by Honeywell and others.
PART NODESCRIPTION
9000FAST-STAT 9000 Wire Extender
Kure-A-Stat – Energy Saving Chip
• Micro post-purge fan off delay timer
• Measures run time of the compressor and/or
heating system; calculates the best fan off
delay time to purge ducts of residual air
PART NODESCRIPTION
Kure-A-StatKure-A-Stat - Energy Saving Chip
• Works on all 24V systems that
have a common wire, including
heat pumps
• 5-year limited warranty
HUMIDISTATS & DEHUMIDISTATS
H8908ASPST Humidistat
Can be mounted in either vertical or horizontal configuration.
PART NOPART NO(VAC)CONFIGOPERATIONRANGE (% RH)LOCATONWxHxD (IN)
H8908ASPSTH8908ASPST24SPSTContacts close on humidity drop10-60Wall, Duct 5-1/2 x 4 x 2-1/2
VENDORVOLTAGECONTACTCONTACTADJUSTMENTMOUNTINGSIZE
45-25055-99 Humidistat
PART NOPART NO(VAC)CONFIGOPERATIONRANGE (% RH)LOCATONWxHxD (IN)
45-25055-99352680-00824SPSTContacts close on humidity drop20-80Wall, Duct
VENDORVOLTAGECONTACTCONTACTADJUSTMENTMOUNTINGSIZE
4-3/4 x 2-7/8 x 1-3/8
H8908DSPST Dehumidistat
Can be mounted in either vertical or horizontal configuration.
PART NOPART NO(VAC)CONFIGOPERATIONRANGE (% RH)LOCATONWxHxD (IN)
H8908DSPSTH8908DSPST/U24SPSTContacts close on humidity rise10-60Wall, Duct 5-1/2 x 4 x 2-1/2
VENDORVOLTAGECONTACTCONTACTADJUSTMENTMOUNTINGSIZE
41-25066-02 Dehumidistat
PART NOPART NO(VAC)CONFIGOPERATIONRANGE (% RH)LOCATONWxHxD (IN)
41-25066-02J10-809-07024SPSTContacts close on humidity rise20-80Wall
VENDORVOLTAGECONTACTCONTACTADJUSTMENTMOUNTINGSIZE
4-3/8 x 2-7/8 x 1-1/2
30WWW.RHEEMPARTS.COM WWW.RUUDPARTS.COM
Page 27
DUCT SMOKE DETECTORS & ACCESSORIES
DUCT SMOKE DETECTORS – AIR PRODUCTS AND CONTROLS
SL-2000 SERIES DUCT SMOKE DETECTORS
Product Application: The SL-2000 Series Smoke
Duct Detector is the latest innovation for early detection of smoke and products of combustion
present in air moving through HVAC ducts in Commercial, Industrial, and Residential applications.
The unit is designed to prevent the recirculation or
spread of smoke by air handling systems, fans,
and blowers. Complete systems may be shut
down in the event of smoke detection. The SL2000 is designed and built to meet all local code
requirements, as well as the NFPA and ICC standards regarding HVAC supply and return duct
smoke detectors. Output terminals are provided for
a wide range of remote accessories such as horns,
strobes, remote status indicators, and test/reset
key switches or push buttons.
Product Description: The SL-2000 includes many
features that represent true innovations from current generation duct smoke detectors. Air Products
and Controls’ traditional installer/ servicer-friendly
approach has been closely followed and expanded
throughout the SL-2000. This philosophy provides
a new level of efficiency in after-purchase value to
both the installer/ servicer and end-user. Attention
to detail has yielded a host of “No-Tools Required”
features, as well as a multi-application performance
level as yet unmatched in the industry. The key features below detail many of the customer-driven innovations incorporated in the SL-2000 Series.
Innovative product combined with unsurpassed
customer service equals the right combination for
all of your projects.
• Low-Flow Technology: Both Ionization and
Photoelectric models listed for velocities between
100-4000 ft./min
• Both models listed for high-temperature
applications
• Operating voltages: 230/120/24VAC, 24VDC
• Interconnect up to 30 units for common functions
• Patent-pending “No-Tools Required” front or rear
loading and removing sampling/exhaust tubes
• Patent-pending “Test Port Valve” allows for
aerosol smoke testing without
cover removal
• Clear cover fitted with four captive “No-Tools
Required” thumbscrews
• Instantaneous cover removal trouble indication
• Staggered terminal blocks for easier wiring
• Flashing LED on detector head indicates normal
operation
• Magnet test capability (magnet included)
• More wiring space than competitive models
• Footprint allows easy retrofit in many applications
without additional drilling
• Over 15 remote accessories available
• Duct wall gaskets on back of enclosure are pre-
installed
• Compatible with the WP-2000 weatherproof
enclosure
• Reset switch is also an alarm test switch -
competitive models require a magnet or cover
removal to test at unit
• Unit includes green pilot and red alarm visual
indicators
• External mounting tabs do not require cover
removal to install
• Colored cover gasket indicates proper cover seal
• UL, C-UL, CSFM, and MEA Listed
• Compact, lightweight size means easy handling,
lower shipping costs
• Two sets of 10A form “C” alarm contacts
• One set of 2A form “A” alarm contacts
• One set of 10A form “C” trouble contacts
• Large terminal connection screws
• Standard interchangeable “plug-in” UL268
photoelectric or ionization heads
• Advanced detector head design yields internal
dust filtering
• No additional screens or filters to clean
• Compatible with building automation and fire
alarm systems
• Ionization and Photoelectric versions available
• Complete wiring details permanently fixed to unit
849050STN-1.0Sampling Tube - 10 in. (For SL-2000)1—
849051STN-2.5Sampling Tube - 2.5 ft. (For SL-2000)5Yes
849052STN-5.0Sampling Tube - 5.0 ft. (For SL-2000)5Yes
849053STN-10.0Sampling Tube - 10.0 ft. (For SL-2000)1—
31THERMOSTATS & ALARMS
Page 28
DUCT SMOKE DETECTORS & ACCESSORIES
DUCT SMOKE DETECTORS – AIR PRODUCTS AND CONTROLS
SM-501 SERIES DUCT SMOKE DETECTORS
Product Application: The SM-501 Series Duct
Smoke Detector provides early detection of smoke
and products of combustion present in air moving
through HVAC ducts in Commercial, Industrial, and
Residential applications. The unit is designed to
prevent the re-circulation or spread of smoke by air
handling systems, fans, and blowers. Complete
systems may be shut down in the event of smoke
detection. The SM-501 model will operate on any
one of four input voltages (230, 120, or 24VAC or
24VDC). The SM-501 allows up to 30 detectors to
be interconnected for many common functions.
Product Description: Continuing Air Products and
Controls’ history of building innovative and reliable
products, the SM-501 is housed in the popular traditional compact housing. The unit provides two
sets of 10 Amp form “C” alarm contacts, along
with one set of 10 Amp form “C” trouble contacts
for monitoring head removal and supply voltage
failure. The green pilot and red alarm visual indicators provided on the front of the SM-501 signal the
operating status of the device. The green pilot LED
will be extinguished when the detector head is removed or power is lost. A manual test/reset switch
is located next to the visual indicators. The SM-501
has been specially designed to allow linkage of
common detector functions for up to 30 detectors.
The units may be wired to use a common
test/reset function, and to alarm when a single unit
alarms. Also, up to 15 units with signaling devices
may be intercon-nected to operate with a single
alarm. The SM-501 is designed and built to meet
all local code requirements, as well as the NFPA
and ICC standards regarding HVAC supply and return duct smoke detectors. Output terminals are
provided for remote accessories such as horns,
strobes, remote status indicators, and test/reset
key switches or push buttons. The SM-501 is avail-
able with either ionization or
photo-electric detector heads,
which are inter-changeable. Air sampling is accomplished via two rear loading tubes which protrude
into the duct. An exhaust tube of one standard
length (7.0 in) is supplied in the installation kit with
the duct smoke unit. Once the duct width has
been determined, the air intake sampling tube
must be ordered. Sampling tubes are supplied in
standard lengths (1.0, 2.5, 5.0, and 10.0 foot), and
are cut to size to fit the duct. Mounting the duct
smoke detector is accomplished by the use of a
template and four sheet metal screws, as provided.
Mounting can be achieved without the removal of
the clear cover, which is secured by four captive
screws.
• Operating voltages: 230/120/24VAC, 24VDC
• Both models listed for high temperature applica-
tions
• UL, C-UL, CSFM, and MEA Listed
• Interconnect up to 30 units for common functions
• Compact Size
• Two sets of 10A form “C” alarm contacts
• One set of 10A form “C” trouble contacts
• Rugged steel back box with clear cover
• Compatible with WP-1 weatherproof enclosure
• Easy retro-fit/upgrade of existing RW Series de-
tectors
• Clear cover fitted with 4 captive screws
• Large terminal connection screws
• Interchangeable “Plug-In” photoelectric or ioniza-
tion heads
• Easy mounting without cover removal
• Advanced detector head design yields internal
dust filtering with no additional screens or filters
to clean
• Over 15 remote accessories available
• Toll-Free Technical Support 888.332.2241
SM-501-N Duct Smoke Detector – Ionization
PART NOVENDOR PART NODESCRIPTION
SM-501-NSM-501-NSmoke Detector - Ionization
SM-501-P Duct Smoke Detector – Photoelectric
PART NOVENDOR PART NODESCRIPTION
SM-501-PSM-501-PSmoke Detector - Photoelectric
Sampling Tubes for SM-500/SM-501 Series
PART NOVENDOR PART NODESCRIPTIONCASE QTY CASE REQ
849054STS-1.0Sampling Tube - 10 in. (For SM-500/SM-501)1—
849055STS-2.5Sampling Tube - 2.5 ft. (For SM-500/SM-501)5Yes
849056STS-5.0Sampling Tube - 5.0 ft. (For SM-500/SM-501)5Yes
849057STS-10.0Sampling Tube - 10.0 ft. (For SM-500/SM-501)1—
32WWW.RHEEMPARTS.COM WWW.RUUDPARTS.COM
Page 29
DUCT SMOKE DETECTORS & ACCESSORIES
DUCT SMOKE DETECTORS – AIR PRODUCTS AND CONTROLS
MS SERIES REMOTE ACCESSORIES
The MS Series remote accessories are designed to be used with the Air Products
and Controls Duct Smoke Detectors to provide audible and visual indication as
well as remote test/reset functions. These devices are constructed of attractive, yet durable
brushed stainless steel and mount on a standard single or double gang electrical box.
MS-RA (849058) – Alarm LED
PART NOVENDOR PART NODESCRIPTION
849058MS-RARemote Accessory - Alarm LED
MS-RA/P (849059) – Alarm & Pilot LEDs
PART NOVENDOR PART NODESCRIPTION
849059MS-RA/PRemote Accessory - Alarm & Pilot LEDs
MS-RA/R (849060) – Alarm LED / Test/Reset Button
PART NOVENDOR PART NODESCRIPTION
849060MS-RA/RRemote Accessory - Alarm LED / Test/Reset Button
MS-RA/P/R (849061) – Alarm & Pilot LEDs / Test/Reset Button
PART NOVENDOR PART NODESCRIPTION
849061MS-RA/P/RRemote Accessory - Alarm & Pilot LEDs / Test/Reset Button
MS-RA/P/T (849062) – Fault/Trouble & Pilot LEDs
PART NOVENDOR PART NODESCRIPTION
849062MS-RA/P/TRemote Accessory - Fault/Trouble & Pilot LEDs
MS-RA/FT/P (849063) – Fault/Trouble & Pilot LEDs / Test/Reset Switch
PART NOVENDOR PART NODESCRIPTION
849063MS-RA/FT/PRemote Accessory - Fault/Trouble & Pilot LEDs / Test/Reset Switch
MS-KA/R (849064) – Alarm LED / Test/Reset Switch
PART NOVENDOR PART NODESCRIPTION
849064MS-KA/RRemote Accessory - Alarm LED / Test/Reset Switch
33THERMOSTATS & ALARMS
Page 30
DUCT SMOKE DETECTORS & ACCESSORIES
DUCT SMOKE DETECTORS – AIR PRODUCTS AND CONTROLS
MS SERIES REMOTE ACCESSORIES
MS-KA/P/R (849065) – Alarm & Pilot LEDs/Test/Reset Switch
PART NOVENDOR PART NODESCRIPTION
849065MS-KA/P/RRemote Accessory - Alarm & Pilot LEDs / Test/Reset Switch
849071MS-RDRemote Accessory - Duct Smoke Detector LED
KEY (849157) for MS Series Accessories
PART NOVENDOR PART NODESCRIPTION
849157KEYAlarm Horn Key (Pack of 2)
MSR-AV AUDIO/VISUAL TERMINAL SERIES
The MSR-AV series provides audible and visible private mode alarm indications in a low-profile, singlegang Decora style configuration. Choice of plate colors. Boasting code compliance with emergency
signaling applications, the MSR-AV is Listed to UL 464 and UL 1638, and offers the industry’s first LED
strobe. The sound output level is jumper-selectable at either 53/54 dB (low) or 68/69 dB (high). The
sound output format is also jumper selectable for steady or temporal (code 3). The units are shipped with
the jumpers installed, pre-set to high, temporal. For use with UL Listed 24VDC polarized power circuits.
MSR-AV/T/R/C (841010) Horn/Strobe – Red w/ Clear Lens
PART NOVENDOR PART NODESCRIPTION
841010MSR-AV/T/R/CHorn/Strobe - Red w/ Clear Lens
MSR-AV/T/W/C (841008) Horn/Strobe – White w/Clear Lens
PART NOVENDOR PART NODESCRIPTION
841008MSR-AV/T/W/CHorn/Strobe - White w/Clear Lens
MSR-AV/T/W/O (841009) Horn/Strobe – White w/Opaque Lens
PART NOVENDOR PART NODESCRIPTION
841009MSR-AV/T/W/OHorn/Strobe - White w/Opaque Lens
MSR-100R/R Remote Accessory Controller
The MSR-100 Series remote accessories are
designed to be used with Air Products and
Controls duct smoke detectors to provide the
most complete functionality ever available in
such a device.
• Visual indication of detector pilot, trouble and
alarm functions
• Selectable audible indication of alarm, trouble
or both
PART NOVENDOR PART NODESCRIPTION
MSR-100R/RMSR-100R/RRemote Accessory - Controller - Red
• Buzzer silence function, with
silenced indication and
“ringback” following condition correction
• Lamp/buzzer test function
• Key-operated detector test and reset functions
• Lever-operated “no-tools” terminal block
• Port for plugging in the optional strobe
assembly
35THERMOSTATS & ALARMS
Page 32
DUCT SMOKE DETECTORS & ACCESSORIES
DUCT SMOKE DETECTORS – AIR PRODUCTS AND CONTROLS
WP-2000 (849079) Weatherproof Enclosure for SL-2000 Series
PART NOVENDOR PART NODESCRIPTION
849079WP-2000Weatherproof Enclosure (For SL-2000)
TG-2000 (849074) Test Gas for SL-2000 Series
PART NOVENDOR PART NODESCRIPTIONCASE QTY CASE REQ
849074TG-2000Test Gas w/Test Port Nozzle (For SL-2000)12Yes
Air Products and Controls Replacement Parts/Service
PART NOVENDOR PART NODESCRIPTION
84908055000-225Replacement Head (For SL-2000-N)
84908155000-328Replacement Head (For SL-2000-P)
84908255000-250Replacement Head (For SM-501-N)
84908355000-350Replacement Head (For SM-501P)
849084STN-XTReplacement Exhaust Tube (For SL-2000-N and SL-2000-P)
849085STS-XTReplacement Exhaust Tube (For SM-501)
849086CLEAN-RECALSmoke Detector Head Cleaning and Recalibration Service
The Innovair Flex D4120 Duct Smoke Detectors
provide superb immunity to false alarms and easy,
labor saving installation options. Its flexible configurations allow an easy replacement to any model, and
its 2 to 1 sensor to power board offers cost savings
where both supply and return installation is required.
The InnovairFlex D4120 4-wire photoelectric duct
smoke detector features a pivoting housing that fits
both square and rectangular footprints and mounts to
round or rectangular ductwork. This unit senses
smoke in the most challenging conditions. An
improved cover design isolates the sensor head from
the low-flow feature for simple maintenance. With its
2:1 sensor-to-power capability, the power board of
the D4120 may be used to monitor a second sensor,
D4S, simultaneously (i.e., supply and return side). As
many as 50 InnovairFlex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays; only the
detector sensing smoke will go into alarm, thus
pinpointing the fire source. An easy-access Test/Reset
button makes it possible to test the unit with the cover
on. Three DIP switches can be used to configure field
selectable settings: cover tamper delay, number of
sensors to be controlled, and shut down on trouble
option. Each power board has two LEDs that can be
used to indicate the status of connected sensors, and
a quick reference imprinted on the cover explains the
LED status indications (Standby, Maintenance,
PART NODESCRIPTION
D4120Duct Smoke Detector - Photoelectric, 4-Wire
Trouble, and Alarm). The InnovairFlex duct smoke
detector can be customized to meet local codes and
specifications without additional wiring.
• Versatile mounting options: square or rectangular
configuration
• Air velocity rating from 100 ft/min to 4,000 ft/min
(0.5 m/s to 20.32 m/sec)
• Broad ranges for operating temperature (-4°F to
158°F) and humidity (0% to 95% non-condensing)
• Patented sampling tube installs from front or back of
InnovairFlex duct smoke detector with NEMA Type 4 enclosure for non-hazardous locations indoor,
and for outdoor rooftop installations – saving the cost of expensive separate enclosures.
DST1Sampling Tube - Duct Widths up to 1 ft. (For Innovair Flex)10Yes
DST1.5Sampling Tube - Duct Widths 1 to 2 ft. (For Innovair Flex)10Yes
DST10Sampling Tube - Duct Widths 8 to 12 ft. (For Innovair Flex)3Yes
DST3Sampling Tube - Duct Widths 2 to 4 ft. (For Innovair Flex)10Yes
DST5Sampling Tube - Duct Widths 4 to 8 ft. (For Innovair Flex)10Yes
REMOTE TEST STATIONS
RTS151 Remote Test Station
Remote test (magnet) and reset station with status LED.
PART NODESCRIPTION
RTS151Remote Test Station
RTS151KEY Remote Test Station with Key
Key remote test and reset station with status LED.
PART NODESCRIPTION
RTS151KEYRemote Test Station with Key
37THERMOSTATS & ALARMS
Page 34
DUCT SMOKE DETECTORS & ACCESSORIES
DUCT SMOKE DETECTORS – SYSTEM SENSOR
MULTI-SIGNALING ACCESSORIES
RTS2-AOS Multi-Signaling Accessory with Add-on-Strobe
RTS2-AOS is multi-signaling accessory designed to work with InnovairFlex 4-wire conventional duct
smoke detectors. AOS stands for “Add On Strobe”. The RTS2 and AOS may be ordered separately
PART NODESCRIPTION
RTS2-AOSMulti-Signaling Accessory w/Strobe
RTS2 Multi-Signaling Accessory
PART NODESCRIPTION
RTS2Multi-Signaling Accessory w/o Working Strobe
AOS Add-On-Strobe
PART NODESCRIPTION
AOSAdd-On-Strobe – Component for RTS2
MHW Mini-Horn
The SpectrAlert®Advance MHW is the white, 12/24V mini-horn used where
a smaller notification device is desired.
PART NODESCRIPTION
MHWMini-Horn - White
REMOTE ANNUNCIATORS
APA151 Remote Annunciator with Piezo and Alarm/Power LEDs
Remote annunciator with piezo alarm and status LED.
PART NODESCRIPTION
APA151Remote Annunciator w/Piezo/Alarm/Power LED
RA100Z Remote Annunciator with Alarm LED
Remote annunciator with red LED alarm indication.
PART NODESCRIPTION
RA100ZRemote Annunciator w/Alarm LED
38WWW.RHEEMPARTS.COM WWW.RUUDPARTS.COM
Page 35
CARBON MONOXIDE (CO) ALARMS
AC Powered Plug-In with Battery Backup
The Kidde AC-powered carbon monoxide alarm
plugs directly into a standard wall outlet making
installation quick and easy. The two AA battery
backup provides protection even during power
outages when many CO incidences occur. The
tamper resist feature deters tampering or theft of
the unit. It is a great CO alarm for property
owners that are concerned with theft, or parents
with small children. The unit alerts you if it has
been unplugged or if it comes loose from the wall
outlet. This alarm uses advanced electromechanical sensing technology to monitor for
carbon monoxide levels in your home. This alarm
has a compact that does not conceal seoncdary
receptacle space in a standard outlet. Provides a
loud warning signal against the dangers of
elevated CO levels. This alarm is easily installed in
AC wall outlets. The green LED shows that AC
power is present and the alarm is working
properly. The red LED will illuminate when the
alarm detects carbon monoxide.
Tamper resist feature - Unit
goes into constant alarm mode if it has been
unplugged or has come loose from the outlet
•
AAA battery backup - Provides continuous
protection even during power outages.
•
Low battery hush®- Silences low battery chirp
warning for up to twelve hours in order to
maintain protection without having to replace
the battery at an inconvenient time
•
Easy installation - Mounts to any wall outlet
•
Battery pull tab - Eliminates battery installation
time and keeps battery fresh
•
Loud 85dB alarm - Alerts of deadly CO gas
•
Test/Reset button - Tests the alarm electronics
and resets the unit during alarm
•
Green LED - Indicates alarm is receiving power
and operating properly
•
Red LED - Illuminates when in alarm mode
•
UL listed
•
10-year limited warranty.
Battery Operated
The Kidde battery operated carbon monoxide
alarm utilizes sophisticated electronic
components to protect from the dangers of
carbon monoxide. This alarm includes a slide-out
battery door that gives immediate access to the
batteries and a safety feature that makes it difficult
to close the door without the batteries being
installed. Inside cover of battery door features
quick reference guide for what to do in case of an
alarm. This easy-to-install alarm is suitable for all
living areas. UL Listed with a 10-year limited
warranty. Provides a loud warning signal against
the dangers of elevated CO levels. The batteryoperated CO alarm provides continuous monitoring of CO levels, even during power outages
when AC-only units are not providing protection.