Rheem Single Element, Double Element Use & Care Manual

WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR
Residential Electric Water Heater
USE & CARE MANUAL
AP9029-6 (1/00)
Printed in USA
PROPOSITION 65: This appliance contains fiberglass insulation. Respirable particles of fiberglass are known to the State of California to cause cancer.
Do Not Destroy this Manual. Please read careful­ly and keep in a safe place for Future Reference.
Recognize this symbol as an Indication of Impor­tant Safety Information!
The purpose of this manual is twofold: one, for the installing contractor, to provide requirements and recommendations for the proper installation and adjustment of the water heater; and two, for the owner-operator, to explain the features, operation, safe­ty precautions, maintenance and trouble shooting of the water heater. This manual also includes a parts list.
It is imperative that all persons who are expected to install, op­erate or adjust this water heater read the instructions carefully so that they may understand how to do so.
!
®
LISTED
786H
!
!
2
WATER TEMPERATURE ADJUSTMENT - Safety and en­ergy conservation are factors to be considered when se­lecting the water temperature setting of water heater’s thermostat. Water temperatures above 125°F can cause severe burns or death from scalding. Be sure to read and follow the warnings outlined on the label pictured below. This label is also located on the water heater near the ther­mostat access panel
General Safety Precautions
!
Gasoline, as well as other flammable materials and liq­uids (adhesives, solvents, etc.), and the vapors they pro­duce, are extremely dangerous. DO NOT handle, use or store gasoline or other flammable or combustible mate­rials anywhere near or in the vicinity of a water heater. The arc drawn in the water heater controls can ignite these vapors. Failure to do so can result in property damage, bodily injury, or death.
The chart shown above may be used as a guide in deter­mining the proper water temperature for your home.
NOTE: Households with small children, disabled, or el­derly persons may require a 120°F or lower thermostat setting to prevent contact with “HOT” water.
The temperature of the water in the heater is regulated by the adjustable surface mounted thermostat(s) located behind the Jacket Access Panel(s). Dual element heaters have two thermostats. To comply with safety regulations the thermostat(s) were set at 120° F before the water heater was shipped from the factory.
The illustration above shows the temperature adjustment dial used for setting the water temperature. Refer to Operation section of this manual for detailed instructions in how to adjust the thermostat(s).
There is a Hot Water SCALD Potential if the thermostat is set too high.
Mixing valves for reducing point of use water tempera­ture by mixing hot and cold water in branch water lines are available. Contact a licensed plumber or the local plumbing authority for further information.
Temperature Time to Produce Serious Burn
120° F More than 5 minutes 125° F 1
1
/2to 2 minutes 130° F About 30 seconds 135° F About 10 Seconds 140° F Less than 5 seconds 145° F Less than 3 seconds 150° F About 1
1
/2 seconds
155° F About 1 second
Table courtesy of Shriners Burn Institute
TIME / TEMPERATURE RELATIONSHIPS IN SCALDS
Be sure to read and understand the entire Use & Care Manual before attempting to install or operate this water heater. It may save you time and cost. Pay particular attention to the General Safety Precautions. Failure to follow these warnings could result in serious bodily injury or death . Should you have prob­lems understanding the instructions in this manual, or have any questions, STOP, and get help from a qualified installer, service technician, or the local electric utility.
Thermostat Protective
Cover
Thermostat Dial
Pointer
Reset Button
WARNING
!
!
DANGER
HOT
BURN
Water temperature over 125°F can cause severe burns instantly or death from scalds.
Children, disabled and elderly are at highest risk of being scalded.
See instruction manual before setting temperature at water heater.
Feel water before bathing or showering.
Temperature limiting valves are available, see manual.
R
T
E
E
S
S
E
E
T
R
90°F150°F
125°F
TURN OFF
POWER
BEFORE
SERVICING
DANGER
!
1. INSPECT SHIPMENT — Inspect water heater for possible dam-
age. Check the markings on the rating plate of the water heater to be certain the power supply corresponds to that for which the water heater is equipped.
2. THERMAL EXPANSION — Determine if a check valve exists in the inlet water line. It may have been installed in the cold water
line as a separate back flow preventer, or it may be part of a pres­sure reducing valve, water meter or water softener. A check valve located in the cold water inlet line can cause what is referred to as a ”closed water system”. A cold water inlet line with no check valve or back flow prevention device is referred to as an ”open” water system.
As water is heated, it expands in volume and creates an increase in the pressure within the water system. This action is referred to as ”thermal expansion”. In an ”open” water system, expanding water which exceeds the capacity of the water heater flows back into the city main where the pressure is easily dissipated.
A ”closed water system”, however, prevents the expanding water from flowing back into the main supply line, and the result of ”thermal expansion” can create a rapid, and dangerous pres- sure increase in the water heater and system piping. This rapid pressure increase can quickly reach the safety setting of the re­lief valve, causing it to operate during each heating cycle. Ther­mal expansion, and the resulting rapid, and repeated expansion and contraction of components in the water heater and piping system can cause premature failure of the relief valve, and pos­sibly the heater itself. Replacing the relief valve will not correct the problem!
The suggested method of controlling thermal expansion is to install an expansion tank in the cold water line between the water heater and
the check valve. (refer to Figure 2.) The expansion tank is designed with an air cushion built in that compresses as the system pressure increases, thereby relieving the over pressure condition and elimi­nating the repeated operation of the relief vale. Other methods of con­trolling thermal expansion are also available. Contact your installing contractor, water supplier, or plumbing inspector for additional in­formation regarding this subject.
3. WATER SUPPLY CONNECTIONS — Refer to Fig. 2 for suggested
typical installation. The installation of unions or flexible copper connectors is recommended on the hot and cold water connec­tions so that the water heater may be easily disconnected for ser­vicing if necessary. The HOT and COLD water connections are clearly marked and are 3/4” NPT on all models. Install a shut-off valve in the cold water line near the water heater.
IMPORTANT!! Do not apply heat to the hot or cold water connections. If sweat connections are used, sweat tubing to adapter before fitting adapter to hot or cold water connections on heater. Any heat applied to the hot or cold water supply fittings will permanently damage them.
4. RELIEF VALVE — A new combination temperature and pressure
relief valve, complying with the Standard for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22, must be installed in the opening provided and marked for the purpose on the water heater. (Refer to Fig. 2.) No valve of any type should be installed between the relief valve and the tank. Local codes shall govern the installation of relief valves.
The pressure rating of the relief valve must not exceed 150 PSI, the maximum working pressure of the water heater as marked on the rating plate. The BTUH Rating of the relief valve must not be less than the input rating of the water heater as indicated on the
3
The location chosen for the water heater must take into considera­tion the following:
LOCAL INSTALLATION REGULATIONS
This water heater must be installed in accordance with these in­structions, local codes, utility company requirements or, in the ab­sence of local codes, the latest edition of the National Electrical Code. It is available from some local libraries or can be purchased from the National Fire Prevention Association, Batterymarch Park, Quincy, MA 02269 as booklet ANSI/NFPA 70.
LOCATION
Locate the water heater in a clean dry area as near as practical to the area of greatest heated water demand. Long uninsulated hot water lines can waste energy and water. Place the water heater in such a manner that the thermostat and element access panels can be re­moved to permit inspection and servicing such as removal of ele­ments or checking controls. The water heater and water lines should be protected from freezing temperatures. Do not install the water heater in outdoor, unprotected areas.
The water heater should not be located in an area where leakage of the tank or connections will result in damage to the area adjacent to it or to lower floors of the structure. Where such areas cannot be avoided, it is recommended that a suitable catch pan, adequately drained, be installed under the water heater.
NOTE: Auxiliary catch pan installation MUST conform to local codes.
Catch Pan Kits are available from the distributor or store where the water heater was purchased
This water heater SHOULD NOT be installed in a space where liquids which give off flammable vapors are to be used or stored. Such liq­uids include gasoline, LP gas (butane and propane), paint or adhe­sives and their thinners, solvents or removers. Because of natural air movement in a room or other enclosed space, flammable vapors can be carried from where their liquids are being used or stored. The arc drawn within the water heater’s control can ignite these vapors caus­ing an explosion or fire which may result in severe burns or death to those in range, as well as property damage.
Figure 1. — Auxiliary Catch Pan
Introduction
Installation
A —Diameter of water
heater plus 2" min.
B — Maximum 2"
To open drain, line should be at least
3
4" ID and pitched
for proper drainage.
A
B
CAUTION
!
WARNING
!
4
rating label located on front of the heater (1 watt = 3.412 BTUH). Connect the outlet of the relief valve to a suitable open drain so that the discharge water cannot contact live electrical parts and to eliminate potential water damage. Piping used should be of a type approved for hot water distribution. The discharge line must be no smaller than the outlet of the valve and must pitch down­ward from the valve to allow complete drainage (by gravity) of the relief valve and discharge line. The end of the discharge line should not be threaded or concealed and should be protected from freezing. No valve of any type, restriction or reducer coupling should be installed in the discharge line.
5. TO FILL WATER HEATER — Make certain drain valve is com-
pletely closed. Open shut-off valve in cold water supply line. Open each hot water faucet slowly to allow air to vent from the water heater and piping. A steady flow of water from the hot water faucet(s) indicates a full water heater.
Tank MUST BE full of water before power is turned on. Heating ele­ment(s) WlLL BE DAMAGED if energized for even a short time while tank is dry. The water heater’s warranty does not cover damage or fail­ure resulting from operation with an empty or partially empty tank. (Reference is made to the limited warranty for complete terms and conditions.)
6. ELECTRICAL CONNECTIONS — A separate branch circuit with
copper conductors, overcurrent protective device and suitable disconnecting means must be provided by a qualified electrician. All wiring must conform to local codes or latest edition of the Na­tional Electrical Code ANSI/NFPA 70.
The water heater is completely wired to the junction box inside jacket at top front of water heater. An opening for l⁄2” or 3⁄4” electri- cal fitting is provided for field wiring connections. (Refer to Fig. 3)
The voltage requirements and wattage load for the water heater is specified on the rating plate on front of heater.
Table 1 recommends minimum branch circuit sizing based on National Electric Code. Refer to wiring diagram on back cover of this manual for field wiring connections.
Installation
R
E
L
I
E
F
V
A
L
V
E
COLD
HOT
Figure 2. — Typical Installation
Heat Trap
6" Min.
Hot Water
Outlet to Fixtures
Electrical Junction
Box
(Use only Copper
Conductors)
Jacket Access
Panels
Heat Trap 6" Min.
Union
Union
Air Gap 6"
Auxiliary Catch Pan
Drain Valve
Temperature & Pressure Relief Valve
To Electrical Distribution Panel
Anode
Table 1. — Branch Circuit Sizing Guide Based on
N.E.C. ANSI / NFPA 70
Figure 3. — Water Heater Junction Box.
P
Recommended Over
Total h
Current Protection Copper Wire Size -
Water a
(Fuse or Circuit Breaker) AWG Based on N.E.C.
Heater s
Amperage Rating Table 310-16 (75°C.)
Wattage e 208V 240V 277V 480V 208V 240V 277V 480V
3,000
12020151512121414 3 20 20 --- 15 12 12 --- 14
4,000
12525201510101214 3 25 25 --- 15 10 10 --- 14
4,500
13025251510101014 3 30 25 --- 15 10 10 --- 14
5,000
13030251510101014 3 30 30 --- 15 10 10 --- 14
5,500
1 35 30 25 15 8 10 10 14 3 35 30 --- 15 8 10 --- 14
6,000
140353020 8 8 1012 3 35 30 --- 15 8 10 --- 14
8,000
150454025 8 8 8 10 3 45 40 --- 20 8 8 --- 12
9,000
1 --- 50 45 25 --- 8 8 10 3 50 45 --- 25 8 8 --- 10
10,000
1 --- --- 50 30 --- --- 8 10 3 --- 50 --- 25 --- 8 --- 10
11,000
1 --- --- 50 30 --- --- 8 10 3 --- 50 --- 25 --- 8 --- 10
12,000
1 --- --- --- 35 --- --- --- 8 3 --- --- --- 30 --- --- --- 10
Shut-Off
Valve
To Cold Water Supply
Relief Valve Discharge Line to suitable open drain
Thermal Expansion Tank (if required)
!
WARNING