Rheem CRITERION II PLUS 2 LXE RGPL- SERIES User Manual

CRITERION®II PLUS 2 LXE TWO STAGE 80% A.F.U.E.
UPFLOW/HORIZONTAL GAS FURNACES
The Rheem®Criterion II Plus 2 LXE line of upflow/horizontal gas furnaces are designed for utility rooms, closets, alcoves, or attics. Because of the Criterion’s low-profile
34 inch [864 mm] height, the upflow model installed vertically can also be used to satisfy most applications that traditionally call for a horizontal furnace.
The design is certified by CSA International.
Features
Patented Heat Exchanger, constructed of both stainless and
aluminized steel for the maximum in corrosion resistance.
Low profile “34 inch” [864 mm] design is lighter and easier
to handle, and leaves room for optional equipment.
Energy efficient and quiet ECM 2+ motor.
Improves cooling efficiency when matched with rated con-
densing unit and coil.
Constant CFM.
Dip switch settings for selectable heating temperature rise
and cooling airflow.
On-demand dehumidification terminal for improved com-
fort in cooling mode.
Convertible from upflow to horizontal left or right without
field conversion.
Left or right side gas and electric inlet connections.
All models equipped with remote sense feature, an inte-
grated board with humidifier and electronic air cleaner hookups.
Insulated blower compartment, a slow-open gas valve, a
specially designed draft inducer motor and blower motor make it one of the quietest furnaces on the market today.
Pre-paint galvanized steel cabinet.
Molded permanent filter.
Grab-holes in doors to aid in easy door removal and
replacement.
Compatible with single or two-stage thermostat. (For opti-
mal performance, two-stage thermostat recommended.) A variety of cooling coils and plenums designed to use with Rheem Criterion II Plus 2 LXE gas furnaces are available as optional accessories.
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of
Energy test procedures.
FORM NO. G11-473 REV. 5
Supersedes Form No. G11-473 Rev. 4
GAS FURNACES
RGPL- SERIES
ECM Equipped Models with Input Rates from 50,000 to 125,000 BTU/HR [15 to 37 kW] (U.S. & Canadian Models)
ENER UIDE
Annual Fuel Utilization Efficiency -
THIS MODEL
80.0%
MID
82% 88%
ISO 9001:2000
HIGH
AFUE
97%78%
2 Rheem Manufacturing Company
Direct Spark Ignitor
Remote Sensor
In-Shot Burners
Integrated Furnace Controls
Heat Exchanger
Two-Speed Draft Inducer Motor
ECM Motor
The complete terms of limited and other warranties are available at our sales office, or through local installer.
All models can be converted by a qualified Rheem distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Rheem parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
STANDARD EQUIPMENT
Completely assembled and wired; 2 speed draft inducer; high and low pressure switches; redundant 2 stage main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; transformer; direct drive multi-speed blower motor. Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics; fused protection (secondary), 3rd speed fan option
for continuous fan.
OPTIONAL EQUIPMENT
Side filter frame assembly. Return air cabinet for all sizes. (See Page 6) NOTE: Furnace is not listed for use with fuels other than natural or L.P.
(propane) gas.
RHEEM CRITERION II PLUS 2 LXE TWO STAGE 80% UPFLOW/HORIZONTAL GAS FURNACE
Rheem Manufacturing Company 3
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS (UPFLOW) U.S. AND CANADA MODELS
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy.
Gas Heat Exchanger Limited Warranty .......Twenty (20) Years
*Any Other Part..............................................Five (5) Years
*This five year limited warranty is applicable only to single-phase products
installed in residential applications on or after January 1, 2001.
MODEL IDENTIFICATION—UPFLOW MODELS
[ ] Designates Metric Conversions
In accordance with D.O.E. test procedures.See Conversion Kit Index Form for high altitude derate.
RG P L
07E
Furnace
BR K R
Rheem Gas Upflow/ Design Heating Input Designation
Horizontal Series
Variations Blower Heating & Cooling Fuel Type
M = 11 x 7
[279 x 178 mm]
R = 11 x 10
[279 x 254 mm]
K = 600-1200 CFM
[283-566 L/s]
M = 1200-2000 CFM
[566-944 L/s]
Q = 1000-1600 CFM
[566-944 L/s]
Electric Ignition
05E 07E 10E 12E
A = Std.
Cabinet
B = Wide
Cabinet
Designation Designation R = Natural Gas,
U.S. and Canadian Standard Furnace
Input
BTU/HR
50,000 [15 kW]
75,000 [22 kW] 100,000 [29 kW] 125,000 [37 kW]
NO
x
Model
05N 07N 10N 12N
MODEL NUMBERS RGPL- SERIES
High Input–BTU/Hr [kW] Heating Capacity–BTU/Hr [kW] Low Input–BTU/Hr [kW] 35,000 [10] 52,500 [15] 70,000 [20] 87,500 [25] Heating Capacity–BTU/Hr [kW] 28,000 [8] 41,600 [12] 56,000 [16] 70,080 [20] Heating–Ext. Static Pressure [kPa] .10 [.025] .12 [.029] .15 [.037] .20 [.05]
Blower (D x W) [mm]
ECM Motor H.P. [W] Motor Full Load Amps. 9.6 7.7 12.8 12.8
Heating Speed CFM–High Fire [L/s] 860 [405] 1060 [500] 1320 [623] 1890 [892] Heating Speed CFM–Low Fire [L/s] 648 [306] 700 [330] 942 [445] 1296 [573] Cooling CFM @ .5" [kPa] E.S.P.
(Nominal) [L/s] Max. E.S.P. (In. W.C.) [kPa] 0.5 [.12] 0.5 [.12] 0.5 [.12] 0.5 [.12] Temperature Rise Range °F
[°C] Max. Outlet Air Temp. °F [°C] 155 [68.3] 170 [76.6] 170 [76.6] 180 [82.2] Standard Filter Size–Inches
[mm]
Return Air Cabinets (Opt.) RXGR­Filter Size [mm]
AFUE
05EBMKR 05NBMKR
50,000 [15] 75,000 [22] 100,000 [29] 125,000 [37] 40,900 [12] 61,280 [18] 81,470 [24] 101,660 [29]
11 x 7
[279 x 178]
3
/4 [559]
1200 [566]
25-55
[13.9-30.6]
153/4 x 25
[400 x 635]
C17B
(2) 12 x 16
[305 x 406]
80.5% 80.3% 80.0% 80.0%
07EBRKR 07NBRKR
11 x 10
[279 x 254]
1
/2 [373]
1200 [566]
30-60
[17-33]
191/4 x 25
[489 x 635]
C21B
(2) 20 x 16
[508 x 406]
07EBRQR 07NBRQR
75,000 [22] 61,280 [18] 52,500 [15] 41,600 [12]
.12 [.029]
11 x 10
[279 x 254]
3
/4 [559]
9.6
12.0Unit Amps 8.7 8.7 12.0 12.0 15Maximum Overcurrent Protection 15 15 15 15
1060 [500]
700 [330]
1600 [755]
0.5 [.12] 30-60
[17-33]
170 [76.6]
191/4 x 25
[489 x 635]
115 [52]Approx. Shipping Weight (Lbs.) [kg] 110 [50] 115 [52] 120 [54] 140 [63]
C21B
(2) 20 x 16
[508 x 406]
80.3%
10EBRMR 10NBRMR
11 x 10
[279 x 254]
1 [746] 1 [746]
2000 [944]
40-70
[22.2-38.9]
191/4 x 25
[489 x 635]
C21B (2) 20 x 16 [508 x 406]
12EARMR 12NARMR
11 x 10
[279 x 254]
2000 [944]
35-65
[19.4-36.1]
223/4 x 25
[578 x 635]
C24B (2) 24 x 16 [610 x 406]