Rheem CRITERION II Installation Manual

FORM NO. G11-449 REV. 6
Supersedes Form No. G11-449 Rev. 5
GAS FURNACES
CRITERION®II
80.0-82.2% A.F.U.E.
DOWNFLOW GAS FURNACES
The Rheem®Criterion®II line of downflow gas furnaces is designed for installation in closets, alcoves, utility rooms, or attics. The design is certified by CSA.
Features
Patented heat exchanger, constructed of both stainless
and aluminized steel for the maximum in corrosion resistance.
Low profile “34 inch” [864 mm] design is lighter and easier
to handle, and leaves room for optional equipment.
Left or right side gas and electric inlet connections with
quick, simple change.
Direct Spark ignition models and integrated board with
humidifier and electronic air cleaner hookups.
Insulated blower compartment helps to reduce jacket loss
and noise.
Pre-paint galvanized steel cabinet.
Molded permanent filter.
Grab-holes in doors to aid in easy door removal and
replacement.
A variety of cooling coils and plenums designed to use with Rheem Criterion II gas furnaces are available as optional accessories.
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of
Energy test procedures.
RGLH- SERIES
Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kW]
Annual Fuel Utilization Efficiency -
AFUE
THIS MODEL
ENER UIDE
97%78%
HIGH
MID
82% 88%
80.0%
2 Rheem Manufacturing Company
STANDARD EQUIPMENT
Completely assembled and wired; induced draft; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; manual shut-off valve, pressure regulator for natural and L.P. (propane) gas; transformer; direct drive multi­speed blower motor. Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics; on-board twinning; fused transformer (secondary), 3rd speed option for
continuous fan; common heat/cool terminal.
NOTE: Furnace is not listed for use with fuels other than natural or L.P.
(propane) gas.
The complete terms of limited and other warranties are available at our sales office, or through local installer.
All models can be converted by a qualified Rheem distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Rheem parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form. NOTE: For natural and L.P. (propane) gas models, standard hot surface ignition
is 100% lockout type.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
RHEEM CRITERION II 80% DOWNFLOW GAS FURNACE
Heat Exchanger
Draft Inducer Motor
In-Shot Burners
Molded Permanent Filter
Integrated Furnace Control
Direct Spark Ignitor with Remote Sense
Rheem Manufacturing Company 3
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS
MODEL NUMBERS
RGLH- SERIES
05EAUER 05NAUER
07EAUER 07NAUER
Standard Filter [mm]
(1) 14 x 20
[356 x 508]
(2) 12 x 20
[305 x 508]
Input–BTU/Hr [kW]
50,000 [15] 75,000 [22]
Heating Capacity BTU/Hr [kW]
41,000 [12] 60,000 [18]
High Altitude Input [kW] 45,000 [13] 67,500 [19.8]
Blower (D x W) [mm]
11 x 6
[279 x 152]
11 x 6
[279 x 152]
Motor H.P. [W]–Speeds [W]– PSC Type
1
/2-4-PSC
[373]
1
/2-4-PSC
[373] Motor Full Load Amps 6.8 7.1 Heating Speed MED-LOW MED-HIGH Cooling Speed HIGH HIGH Cooling CFM @ .5" [kPa] E.S.P.
(Nominal) [L/s]
1200 [566]
1200
[566] Rated E.S.P. (In. W.C.) [kPa] .50 [.12] .50 [.12]
Temperature Rise Range °F [°C]
25-55
[13.9-30.6]
40-70
[22.2-38.9]
Max. Outlet Air Temp. °F [°C]
155
[68.3]
165
[73.9]
Approx. Shipping Weight (Lbs.) [kg]
85
[38.6]
105
[47.6]
California Seasonal Efficiency– Electric Ignition NoxModels
75.9/76.2 74.4/74.9
High Altitude Output Capacity [kW]
36,500 [10.7] 53,500 [15.7]
Heat Ext. Static Pressure [kPa] .10 [.025] .12 [.029]
07EAMGR 07NAMGR
10EAMER 10NAMER
10EBRJR
10NBRJR
12EARJR 12NARJR
(2) 12 x 20
[305 x 508]
(2) 12 x 20
[305 x 508]
(2) 14 x 20
[356 x 508]
(2) 14 x 20
[356 x 508]
75,000 [22] 100,000 [29.3] 100,000 [29.3] 125,000 [36.6]
54,000 [15.8] 72,000 [21.1] 72,500 [21.2] 89,000 [26.1]
60,500 [18] 80,000 [23] 81,000 [24] 99,000 [29]
.12 [.029] .15 [.037] .15 [.037] .20 [.05]
67,500 [19.8] 90,000 [26.4] 90,000 [26.4] 112,500 [33]
11 x 7
[279 x 178]
11 x 6 = 10*AU
[279 x 152]
11 x 7 = 10*AM
[279 x 178
11 x 10
[279 x 254]
11 x 10
[279 x 254]
3
/4-4-PSC
[559]
1
/2-4-PSC
[373]
3
/4-4-PSC
[559]
3
/4-4-PSC
[559]
9.5 7.1 9.5 9.5
MED-LOW MED-HIGH MED-LOW MED-LOW
MED-HIGH HIGH MED-HIGH MED-HIGH
1600 [755]
1200 [566]
2000 [944]
2000 [944]
.50 [.12] .50 [.12] .50 [.12] .50 [.12]
25-55
[13.9-30.6]
55-85 = 10*AU
[30.6-47.2]
45-75 = 10*AM
[25-41.7]
40-70
[22.2-38.9]
40-70
[22.2-38.9]
155
[68.3]
190
[87.8]
190
[87.8]
180
[82.2]
105
[47.6]
115
[52.2]
120
[54.4]
140
[63.5]
75.1/75.5 75.2/75.2 74.7/74.7 75.2/75.3
15EARJR 15NARJR
(2) 14 x 20
[356 x 508]
150,000 [44]
107,500 [31.5]
120,000 [35]
.20 [.05]
135,000 [39.6]
11 x 10
[279 x 254]
3
/4-4-PSC
[559]
9.5
MED-LOW
MED-HIGH
2000 [944]
.50 [.12]
50-80
[27.8-44.4]
190
[87.8]
150
[68.0]
76.0/75.9
81.1% 80.2% 80% 80%
AFUE–Electric Ignition Models
82.2% 80.5% 80%
NOTES: All models are 115V, 60HZ, 1Ø. Gas connection size for all models is 1/2" N.P.T.
In accordance with D.O.E. test procedures.See Conversion Kit Index Form No. 92-21519-52 for U.S. models and Form No. 92-21519-53 for Canadian models for high altitude derate.
MODEL IDENTIFICATION—DOWNFLOW MODELS
[ ] Designates Metric Conversions
R G L H
A U E R
Rheem Gas Downflow Design Variations Blower Heating & Cooling Fuel Type
U = 11 x 6
[279 x 152 mm]
M = 11 x 7
[279 x 178 mm]
R = 11 x 10
[279 x 254 mm]
S = 500-1200 CFM
[236-566 L/s]
E = 1100-1330 CFM
[519-628 L/s]
G = 1450-1750 CFM
[684-826 L/s]
J = 1800-2075 CFM
[850-979 L/s]
Furnace Series A = Std.
Cabinet
B = Wide
Cabinet
Designation Designation R = Natural Gas,
U.S. and Canadian Standard Furnace
NO
x
Model
05N 07N 10N 12N 15N
Input
BTU/HR
50,000 [15 kW]
75,000 [22 kW] 100,000 [29 kW] 125,000 [37 kW] 150,000 [44 kW]
Electric Ignition
05E 07E 10E 12E 15E
Heating Input Designation
07E