Rheem Commercial Booster User Manual

ELECTRIC BOOSTER WATER HEATERS
6 KW THRU 18 KW
RHEEM-RUUD Electric Booster Water Heaters
are specifically designed to fit under counters and deliver 180°F (82°C) sanitizing rinse water for all stationary rack and conveyor type commercial dishwashers. They will raise preheated or cold water to 180°F (82°C) rinse temperature for compliance with Local Health Department Sanitation Codes. In addition, these models can be used as circulating tank commercial electric water heaters for gravity or pump circulation to an auxiliary storage tank.
SYSTEM SENTINEL – An exclusive Element Diagnostic Panel. Our new line of electric com­mercial water heaters now includes a compact instantaneous heater in an expanded range of KW power inputs. The completely redesigned single panel control center with hinged stainless steel door provides ready access to all controls, available for either single or three phase opera­tion, these units provide the most versatile and dependable operation we have ever offered in a compact commercial water heater.
Engineering Information
Rheemglas
®
compact commercial electric water heaters are quality engineered models designed to provide the maximum amount of hot water from the energy input of the heating elements. These models include Rheem-Ruud’s System Sentinel
, an exclusive Element Diagnositic Panel. A light emitting diode monitors each element’s on-off cycle and identifies any nonfunctioning element. The precision thermostat(s) is easily adjustable from 100°F to 180°F (38°C to 82°C), with positive off position at low end temperature range. With the design capability to be connected to 208, 240 and 600 volt, single or three phase power installa­tions, they are ideally suited for a wide variety of water heating systems. Detailed engineering information is available in Tables A & B.
10 U.S. GALLON
(37.8 L) CAPACITY
208, 240 AND 600 VOLTAGES
COMPACT FOR UNDERCOUNTER
INSTALLATIONS
Construction Features
GLASS LINED STORAGE TANK – Heavy
duty steel tank protects with double coating of exclusive Rheemglas
®
to resist the corrosive action of hot water. Designed for 150 PSI working pressure. Each tank is supplied with cleanout and two factory installed magnesium anode rods for maximum cathodic protection.
WATER CONNECTIONS – Hot outlet and
cold inlet are 1-1/4" NPS brass nipples which prevent excessive turbulence of heated water and result in optimum tank draw.
HEAVY INSULATION – An effective blanket
of insulation completely surrounds tanks to limit heat loss and assure high operating efficiency.
STAINLESS STEEL DOOR AND CONTROL PANEL – Ideal for food service
applications.
HEATING ELEMENTS – Separate elements
are of the screw-in type and are made of top quality Nichrome
®
embedded in magnesium oxide sealed in a tinned copper tube to afford corrosion resistance and long life.
AUTOMATIC TEMPERATURE CONTROL – Water temperature is maintained
by an external easily adjustable thermostat starting with an OFF position and ranging from 100°F to 180°F (38°C to 82°C) that insure instant power shut off at the selected temperature. Over temperature protection is provided by an immersion high temperature limit control, factory set at 200°F (93°C).
MAGNETIC CONTRACTORS – All models
equipped with contractors, factory wired for simplicity of installation and economical maintenance throughout life of unit.
240 VOLT CONTROL CIRCUIT – all
units are furnished with a 240 volt control circuit. All controls (thermostats, high temperature limit, etc.) are operated off of this basic 240 volt control circuit.
ELECTRICAL CONNECTIONS – Pre-wired,
accessible control box with knock-outs on the side in size selections to match the Canadian Electrical Code. Sizes range from 1/2" to 2". New terminal block will accept both copper and aluminum wire.
STANDARD EQUIPMENT ASME T&P RELIEF VALVE – This is a double safety valve
that relieves when temperature or pressure becomes excessive.
STAINLESS STEEL 6" LEGS SYSTEM SENTINEL
An element
diagnostic panel, utilizing light emitting diodes (LED) corresponding to the number and location of each heating element are energized when the electric elements are operating. An unlit LED pinpoints the exact location of a non-functioning element, making element operation diagnosis simple and positive.
Optional Equipment
ELEMENT FUSING – In addition to all the
above construction features, there is internal fusing available that protects all elements, magnetic contractors, thermostats and internal wiring circuits.
For optional fusing, suffix “F” should be added to the model number. Ex. EG10CF-12KW