FORM NO. X33-1370
Supersedes Form No. X33-1296
JOB NAME MODEL NO.
CONTRACTOR OUTDOOR UNIT MODEL NO.
ENGINEER LOCATION
SUBMITTED FOR APPROVAL RECORD ORDER NO.
DATE
UNIT DATA
HEATING PERFORMANCE
TOTAL CAPACITY INPUT* ......
_______
MBH [kW]
TOTAL CAPACITY OUTPUT* ..
_______
MBH [kW]
DESIGN TEMP. RISE ..............
_______
°F [°C] DB
AFUE ................................................
_______
%
CALIFORNIA SEASONAL
EFFICIENCY ..................................
_______
%
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT......................................
_______
IWG
BLOWER SPEED ..........................
_______
RPM
POWER OUTPUT REQUIREMENT ..
_______
BHP
MOTOR RATING ........................
_______
HP [W]
POWER INPUT REQUIREMENT ........
_______
kW
ELECTRICAL DATA
POWER SUPPLY ..............................
_______ Hz
TOTAL UNIT AMPACITY................
_______
AMPS
MINIMUM WIRE SIZE ....................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ..........
_______
AMPS
FEATURES FOR RGTM-
■ Two stages of operation to save energy and maintain optimal
comfort level.
■ Furnace operates at 70% capacity for low-heat and 100% capacity
for high-heat.
■ Compatible with single or two-stage thermostat. (For optimal perfor-
mance a two-stage thermostat is recommended.)
■ Heat exchanger is constructed of all stainless steel for maximum
corrosion resistance and thermal fatigue reliability.
■ Low profile “34 inch” design is lighter and easier to handle and
leaves room for optional accessories.
■ Left or right side gas, electric, and condensate drainage connections.
■ Integrated control board manages all operational functions and
provides hookups for humidifier and electronic air cleaner.
■ An insulated blower compartment, a slow-opening gas valve and a
specially designed inducer system make it one of the quietest
furnaces on the market today.
■ Variable speed blower motor technology provides ultimate humidity
control, quieter sound levels and year-round energy savings.
■ Optional indoor or outdoor combustion air. In addition, combustion air
may be piped to either the top or side of the cabinet on all downflow
models. A special molded fitting is provided to ease installation.
■ Control fuse protection.
■ Solid bottom is standard.
■ Control board diagnostics.
FIELD INSTALLED ACCESSORIES
Plenum Adapter (RXAA-) ....................................................................
Vent Termination Kits Concentric:
Vertical/Horizontal: RXGY-E03A ..................................................
Horizontal Two Pipe: RXGY-D02, RXGY-D03, BXGY-D04 ..........
Condensate Pump Kit: RXGY-B01 ......................................................
Neutralizer Kit: RXGY-A01............................................................
Fossil Fuel Kit: RXPF-F01 and F02 ....................................................
Return Air Plenum (RXGR-C17B, 21B, 24B) ......................................
External Bottom Filter Rack: RXGF-CB ..............................................
External Side Filter Rack: RXGF-CA (Side) RXGF-CB (Bottom) ......
“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps
must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your Contractor for details or visit www.energystar.gov.”
TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES:
RGTM- Series
95% A.F.U.E. Models with Input Rates of 60, 75, 90 & 105 kBTU
[17.58, 22, 26.38 & 30.77 kW]