FORM NO. X33-1208 REV. 2
Supersedes X33-1208 Rev. 1
JOB NAME MODEL NO.
CONTRACTOR OUTDOOR UNIT MODEL NO.
ENGINEER LOCATION
SUBMITTED FOR APPROVAL RECORD ORDER NO.
DATE
SUBMITTAL SHEET FOR RGTK92% A.F.U.E. OR ABOVE TWO-STAGE
DOWNFLOW/HORIZONTAL GAS FURNACES
Models with Input Rates from 60,000 to 120,000 BTU/HR
[17.58 to 35.17 kW]
UNIT DATA
HEATING PERFORMANCE
TOTAL CAPACITY INPUT* ......
_______
MBH [kW]
TOTAL CAPACITY OUTPUT* ..
_______
MBH [kW]
DESIGN TEMP. RISE ..............
_______
°F [°C] DB
AFUE ................................................
_______
%
CALIFORNIA SEASONAL
EFFICIENCY ..................................
_______
%
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT......................................
_______
IWG
BLOWER SPEED ..........................
_______
RPM
POWER OUTPUT REQUIREMENT ..
_______
BHP
MOTOR RATING ........................
_______
HP [W]
POWER INPUT REQUIREMENT ........
_______
kW
ELECTRICAL DATA
POWER SUPPLY......................
____________ Hz
TOTAL UNIT AMPACITY ................
_______
AMPS
MINIMUM WIRE SIZE ....................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ..........
_______
AMPS
FEATURES FOR RGTK
■ Two stages of operation to save energy and maintain optimal
comfort level.
■ Furnace operates at 70% capacity for low-heat and 100% capacity
for high-heat.
■ Compatible with single or two-stage thermostat. (For optimal perfor-
mance two-stage thermostat recommended.)
■ Heat exchanger tubular construction is stainless steel for maximum
corrosion resistance and thermal fatigue reliability.
■ Low profile “34 inch” design is lighter and easier to handle and
leaves room for optional accessories.
■ Top electrical connections, left or right side gas, electric, and
condensate drainage connections on downflow/horizontal models.
■ Integrated control board manages all operational functions and
provides hookups for humidifier and electronic air cleaner.
■ An insulated blower compartment, a slow-opening gas valve and a
specially designed inducer system make it one of the quietest
furnaces on the market today.
■ Pre-paint galvanized steel cabinet.
■ Molded permanent filters.
■ Optional indoor or outdoor combustion air.
■ Transformer and control fuse protection.
■ Condensate drain trap for horizontal/downflow application provided
standard.
■ Control board diagnostics.
FIELD INSTALLED ACCESSORIES
Plenum Adapter (RXAA-) ....................................................................
Vent Termination Kits Concentric:
Vertical/Horizontal: RXGY-E03 ....................................................
Horizontal Two Pipe: RXGY-D02, RXGY-D03,
RXGY-D04, RXGY-G02............................................................
Condensate Pump Kit: RXGY-B01 ......................................................
Neutralizer Kit: RXGY-A01............................................................
Fossil Fuel Kit: RXPF-F01 and F02 ....................................................
Return Air Plenum (RXGR-C17B, 21B, 24B) ......................................
External Bottom Filter Rack: RXGF-CB ..............................................
External Side Filter Rack: RXGF-CC ..................................................
Drain Kit for Converting to Left Drain: RXGY-H01 ..............................
High Altitude Kit is not available at this time.