Rheem Classic Series Up to 95 AFUE 2-Stage PSC Motor Specification

90 PLUS®WITH DUAL COMFORT
CONTROL
TWO-STAGE UPFLOW
GAS FURNACES
RGRK- Series
Models with Input Rates 120,000 BTU/HR [35.17 kW] (All Models 90% A.F.U.E.
or Above)
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with
Department of Energy test procedures.
• The Rheem Classic
®
Series 90 Plus with Dual Comfort
Control
line of upflow gas furnaces are designed for utility
rooms, closets, alcoves, or attics. Because of the low-
profile 34 inch [864 mm] height, the upflow model can also be used to satisfy most applications that traditionally call for a horizontal furnace.
• Two stages of operation to save energy and maintain optimal comfort level.
• Furnace operates at 70% capacity for low-heat and 100% capacity for high-heat.
• Compatible with single or two-stage thermostat. (For optimal performance two-stage thermostat recommended.)
• Heat exchanger is constructed of aluminized steel for maxi­mum corrosion resistance and thermal fatigue reliability.
• Low profile “34 inch” design is lighter and easier to handle and leaves room for optional accessories.
• Left or right side gas, electric, and condensate drainage con­nections on upflow models.
• Integrated control board manages all operational functions and provides hookups for humidifier and electronic air cleaner.
• An insulated blower compartment, a slow-opening gas valve and a specially designed inducer system make it one of the quietest furnaces on the market today.
• Pre-paint galvanized steel cabinet.
• Molded permanent filters.
• Optional indoor or outdoor combustion air. In addition, com­bustion air may be piped to either the top or side of the cabi­net on all upflow models. A special molded fitting is provided to ease installation.
• Transformer and control fuse protection.
• Solid bottom is standard.
• Control board diagnostics.
• A variety of cooling coils and plenums designed to use with the Classic 90 Plus gas furnaces are available as optional accessories for air conditioning models.
Air
Gas Furnaces
RGRK Series
Air
Table of Contents
RGRK Series
2
TABLE OF CONTENTS
Standard & Optional Equipment ......................................................................3
Model Features/Physical Data & Specifications..................................................4
Model Number Identification ............................................................................5
Dimensional Data............................................................................................6
Blower Performance Data ................................................................................7
Accessories....................................................................................................8
Limited Warranty ............................................................................................9
PRIMARY AND SECONDARY HEAT EXCHANGER
REMOTE SENSOR
IN-SHOT BURNERS
PRESSURE SWITCHES
DRAFT INDUCER
INTEGRATED
FURNACE
CONTROL
GAS VALVE AND MANIFOLD
DIRECT SPARK IGNITION & REMOTE SENSOR
STANDARD EQUIPMENT
Completely assembled and wired; heat exchanger; primary: aluminized steel, secondary: 29-4C stainless steel; induced draft; pressure switches; redundant main gas control; blower compartment door safety switch; solid state time on/off blower control; limit controls; manual shut-off valve; 100% safety lock out; cool fan off delay; field selectable heat fan off delay; one hour automatic retry; power and self-test diagnostics; flame sense current diagnostics; electronic air cleaner connections; twinning (built-in) features; humidifier connections; humidifier on/off delay; low speed continuous fan option; single speed option for heating and cooling applications; pressure regulator for natural and L.P. (propane) gasses; transformer; direct drive, multi-speed blower motor. (Please note: a thermostat is not included as standard equipment.)
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
OPTIONAL EQUIPMENT
Side and bottom filter racks; return air cabinet for all sizes. NOTE: Furnace is not listed for use with fuels other than natural
or L.P. (propane) gas.
All models can be converted by a qualified distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
Air
Standard & Optional Equipment
RGRK Series
3
Air
Model Features/Physical Data & Specifications
RGRK Series
4
NOTES: All models are 115V, 60HZ, 1ø.Gas connection size for all models is 1/2" [13 mm] N.P.T.
See Conversion Kit Index Form for high altitude derate.Canadian installations only.In accordance with D.O.E. test procedures.
*E = Standard
*N = NO
x
Models
[ ] Designates Metric Conversions
Physical Data and Specifications
U.S. and Canadian Models
• Two stages of operation to save energy and maintain optimal comfort level.
• Furnace operates at 70% capacity for low-heat and 100% capacity for high-heat.
• Compatible with single or two-stage thermostat. (For optimal performance two-stage thermostat recommended.)
• Heat exchanger is constructed of aluminized steel for maxi­mum corrosion resistance and thermal fatigue reliability.
• Low profile “34 inch” design is lighter and easier to handle and leaves room for optional accessories.
• Left or right side gas, electric, and condensate drainage con­nections on upflow models.
• Integrated control board manages all operational functions and provides hookups for humidifier and electronic air cleaner.
• An insulated blower compartment, a slow-opening gas valve and a specially designed inducer system make it one of the quietest furnaces on the market today.
• Pre-paint galvanized steel cabinet.
• Molded permanent filters.
• Optional indoor or outdoor combustion air. In addition, com­bustion air may be piped to either the top or side of the cabi­net on all upflow models. A special molded fitting is provided to ease installation.
• Transformer and control fuse protection.
• Solid bottom is standard.
• Control board diagnostics.
Model Features
MODEL NUMBERS
HIRE FIRE INPUT BTU/HR [kW] LOW FIRE INPUT BTU/HR [kW] HEATING CAPACITY BTU/HR [kW] 113,000 [33.12]
HIGH ALTITUDE INPUT 8000' HIGH ALTITUDE OUTPUT
AT 8000' (HIGH FIRE) [kW] BLOWER (D x W)
[mm] MOTOR H.P. [W]–
SPEEDS–TYPE MOTOR FULL LOAD AMPS HEATING SPEED–HIGH FIRE
COOLING SPEED MINIMUM EXT. STATIC PRESSURE
(IN. W.C.) [kPa] MAXIMUM EXT. STATIC PRESSURE
(IN. W.C.) [kPa] HEATING CFM @ .2" [.049 kPa]
W.C. E.S.P. [L/s] COOLING CFM @ .5" [.124 kPa]
W.C. E.S.P. [L/s] TEMPERATURE RISE-HIGH FIRE
RANGE °F [°C] TEMPERATURE RISE-LOW FIRE
RANGE °F [°C] RETURN AIR CABINETS (OPT.)
RXGR­FILTER SIZE [mm]
STANDARD, HIGH VELOCITY PERMANENT FILTER (IN.)
APPROX. SHIPPING WEIGHT (LBS.) [kg]
AFUE
RGRK-12*RAJS
120,000 [35.17]
84,000 [24.62]
81,600 [23.91]
75,888 [22.24]
11 x 10
[279 x 254]
3
/4 [559]-4-PSC
9.5
MED-HI
LOWHEATING SPEED–LOW FIRE HIGH
.20 [.049]
.50 [.124]
1580 [745]
1900 [897]
50-80
[27.8-44.4]
40-70
[22.2-38.9]
C24B
(2) 24" x 16"
[609 x 406]
223/4 x 25 x 1
160 [72.6]
92.0%