SALES FACT SHEET
Rheem Heating, Cooling and Water Heating FORM NO. A11-217-SFS
P.O. Box 17010, Fort Smith, AR 72917 PRINTED IN U.S.A. QG 10-12
RAPM- JAZ SERIES
Efficiencies up to 16.00 SEER/13.55 EER
Nominal Sizes 1.5 to 5 Tons
[5.28 kW] to [17.6 kW]
Cooling Capacities
18.8 to 62.5 kBTU
[5.50 kW] to [18.32 kW]
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product which fails in
normal use and service within the applicable period stated, in accordance
with the terms of the limited warranty.
Compressor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Ten (10) Years
Conditional Parts (Registration Required) . . . . . . . . . . . . . . . . .Ten (10) Years
Rheem
Classic®Series
Air Conditioners
Features
■
Attractive, louvered wrap-around jacket protects the coil from yard hazards and weather extremes. Top grille is steel reinforced for extra strength.
Cabinet is powder painted for all-weather protection.
■
Air is discharged upward away from bushes and shrubs. The discharge
pattern of the top grille provides minimum air restriction.
■
Combination Grille/Motor Mount secures the motor to the underside of the
discharge grille. The grille protects the motor windings and bearings from
rain and snow.
■
All controls are accessible by removing one service panel. Removable top
grille provides access to the condenser fan motor and condenser coil.
■
Single speed 8-pole fan motor designed for low speed, quiet, energysaving operation.
■
All models meet or exceed a 1000-hour salt spray test per ASTM B117
Standard Practice for Operating Salt Spray Testing Apparatus.
MODEL
Nominal Cooling
Capacity (BTU/HR)
VOLTAGE
PHASE
HEIGHT
WIDTH
LENGTH
Shipping
Weight
Service
Valve -
Liquid
Service
Valve -
Suction
PRICE
018JAZ
024JAZ
030JAZ
036JAZ
042JAZ
048JAZ
056JAZ
060JAZ
18,000
24,000
30,000
36,000
42,000
48,000
56,000
60,000
208/230
208/230
208/230
208/230
208/230
208/230
208/230
208/230
1
1
1
1
1
1
1
1
19"
29"
29"
33"
33"
33"
33"
33"
27 - 5/8"
31 - 1/2"
31 - 1/2"
31 - 1/2"
31 - 1/2"
31 - 1/2"
31 - 1/2"
31 - 1/2"
40 - 1/2"
44 - 3/8"
44 - 3/8"
44 - 3/8"
44 - 3/8"
44 - 3/8"
44 - 3/8"
44 - 3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/4"
3/4"
3/4"
7/8"
7/8"
7/8"
7/8"
7/8"
160.5
214.5
214
227
256
298
306.5
306.5
“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched