Rheem Classic Series Single Stage Submittal Sheet

SUBMITTAL COVER SHEET
Quantity
Unit Designation
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES: NOTES:
PRINTED IN U.S.A 01/12 QG FORM NO. M11-1640
PROJECT NAME
LOCATION
ARCHITECT
ENGINEER
CONTRACTOR
SUBMITTED BY DATE
UNIT SUMMARY
UNIT DATA
COOLING PERFORMANCE
EFFICIENCY ..................................
_______
SEER
TOTAL CAPACITY ....................
_______
MBH [kW]
SENSIBLE CAPACITY ..............
_______
MBH [kW]
OUTDOOR DESIGN TEMP. ........
_______
°F [°C] DB
TEMP. OF AIR ENTERING
EVAPORATOR COIL ..............
_______
°F [°C] DB
_______
°F [°C] WB
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ..................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT........................................
_______
IWC
MOTOR RATING ..........................
_______
HP [W]
ELECTRICAL DATA
POWER SUPPLY ..........................
___________ Hz
MINIMUM WIRE SIZE ......................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ............
_______
AMPS
CLEARANCES
ACCESS SIDE 24" [609.6 mm]
AIR INLETS 6" [152 mm]
ABOVE UNIT 60" [1524 mm]
(-)ANL- SERIES – AIR CONDITIONERS EFFICIENCIES UP TO 14.5 SEER/12.5 EER NOMINAL SIZES 1.5-5 TONS [5.27-17.58 kW]
FORM NO. X33-1406
JOB NAME UNIT MODEL NO.
CONTRACTOR COIL MODEL NO.
ENGINEER AIR HANDLER MODEL NO.
SUBMITTED FOR APPROVAL RECORD LOCATION
DATE ORDER NO.
FEATURES FOR (-)ANL- SERIES
• This unit contains a special scroll compressor that is designed specifically to operate with R-410A refrigerants and polyolester (POE) oils. The compressor is hermetically sealed and incorporates internal high temperature motor overload protection and durable insulation on the motor windings. It is externally mounted on rubber grommets to reduce vibration and noise.
• Compressors have an internal pressure relief assembly to protect against excessive pressure differential.
• All refrigerant connections are on the exterior of the unit, located close to the ground for neat appearing installations.
• Cabinet is constructed of powder painted galvanized steel. The full wrap ­around louvered grille protects the coil from damage.
• Copper tube—aluminum fin coils are used on all models.
• The control box is located in the top corner of the cabinet providing for easy access through a service panel.
• Service valves are standard on all models.
• Power and control wiring are kept separate.
• Every unit is factory charged and tested.
• Separate compressor compartment for easy service access.
• Drawn, painted base pan for extra corrosion resistance and sound reduction.
• Automatic reset high and low pressure controls are standard on all models.
• A liquid line filter drier is standard on all models (shipped – not installed).
Conditional Parts ............................................................................Ten (10) Years
Compressor ....................................................................................Ten (10) Years
FIELD INSTALLED ACCESSORIES
Low Ambient Control ........................................................................................
Compressor Time Delay Control ......................................................................
Hard Start Components ....................................................................................
Compressor Crankcase Heater (CCH) ..............................................................
“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with
appropriate coil components to meet ENERGY STAR criteria. Ask your Contractor for details or visit www.energystar.gov.”

16.0