Rheem Classic Series 80 AFUE Single-Stage X-13 Motor Sales Fact Sheet

SALES FACT SHEET
CLASSIC®SERIES SUPER QUIET 80
80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES w/ECM MOTOR
Features
ECM X-13 Motor for reduced power consumption and improved A/C
efficiency.
Innovative combustion design results in reliable, efficient operation at
sound levels which provide distinct competitive advantage.
Patented Heat Exchanger, constructed of both stainless and aluminized
steel for the maximum in corrosion resistance.
Low profile “34 inch” design is lighter and easier to handle, and leaves
room for optional equipment.
Convertible from upflow to horizontal left or right without field conversion.
Left or right side gas and electric inlet connections with quick, simple
change.
Robust and reliable direct spark ignition utilizing remote sense and an
integrated board with humidifier and electronic air cleaner hookups.
Insulated blower compartment helps to reduce jacket loss and noise.
Pre-paint galvanized steel cabinet.
Molded permanent filter.
Grab-holes in doors to aid in easy door removal and replacement.
A variety of cooling coils and plenums designed to use with Rheem Classic
®
Series Super Quiet 80™gas furnaces are available as optional accessories.
These furnaces can be installed in an upflow position or laid on either side in a horizontal position. Field conversion not required.
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
Gas Heat Exchanger Limited Warranty . . . . . . . . . . . . . . . . . . . . . . .Twenty (20) Years
Conditional Parts Warranty* (Registration Required) . . . . . . . . . . . . . . .Ten (10) Years
*Refer to Product Warranty Card for Details.
Rheem Heating, Cooling and Water Heating FORM NO. G11-507-SFS
P.O. Box 17010, Fort Smith, AR 72917 PR INT ED IN U.S.A. DC 5-10
RGPT- SERIES
ECM Equipped Models with Input Rates from 50,000 to 125,000 BTU/HR [15 to 37 kW]
(U.S. & Canadian Models)
In accordance with D.O.E. test procedures. See Conversion Kit Index Form for high altitude derate.
[ ] Designates Metric Conversions
*E=Standard, N=NOx Models
MODEL
RGPT-05*BMKR 50,000 [15] 41,000 [12] 823 [388] 1600 [755] 105 [48]
RGPT-07*AMKR 75,000 [22] 60,000 [18] 1053 [497] 1200 [566] 105 [48]
RGPT-07*BRQR 75,000 [22] 60,000 [18] 1211 [572] 2000 [944] 120 [54]
RGPT-10*BRMR 100,000 [29] 81,000 [24] 1445 [682] 2000 [944] 120 [54]
RGPT-12*ARMR 125,000 [37] 99,000 [29] 1730 [816] 2000 [944] 140 [63]
INPUT-
BTU/HR [kW]
HEATING CAPACITY
BTU/HR [kW]
HEATING CFM @ .5"
[.12 kPa] W.C. E.S.P. [L/s]
COOLING CFM @ .5"
[.12 kPa] W.C. E.S.P. [L/s]
APPROX. SHIPPING WEIGHT (LBS.) [kg]
PRICE