Rheem Classic Series 80 AFUE 2-Stage PSC Motor Submittal Sheet

SUBMITTAL COVER SHEET
Quantity
Unit Designation
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES: NOTES:
PRINTED IN U.S.A 01/12 QG FORM NO. M11-1640
PROJECT NAME
LOCATION
ARCHITECT
ENGINEER
CONTRACTOR
SUBMITTED BY DATE
UNIT SUMMARY
FORM NO. X33-1385 REV. 1
Supersedes Form No. X33-1231
JOB NAME MODEL NO.
CONTRACTOR OUTDOOR UNIT MODEL NO.
ENGINEER LOCATION
SUBMITTED FOR APPROVAL RECORD ORDER NO.
DATE
FEATURES FOR RGLQ-
Patented heat exchanger, constructed of aluminized steel for the
maximum in corrosion resistance and thermal fatigue reliability.
Low profile “34 inch” [864 mm] design is lighter and easier to
handle, and leaves room for optional equipment.
Left or right side gas and electric inlet connections with quick,
simple change.
Direct spark ignition.
Integrated control board with humidifier and electronic air
cleaner hookups.
Insulated blower compartment, a two stage gas valve and a
specially designed two speed draft inducer motor make it one of the quietest furnaces on the market today.
Pre-paint galvanized steel cabinet.
Grab-holes in doors to aid in easy door removal and replacement.
Compatible with single or two-stage thermostat. (For optimal
performance, two-stage thermostat recommended.)
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test
procedures.
FIELD INSTALLED ACCESSORIES
Fossil Fuel Kit (RXPF-F01 and F02) ........................................
Filter Rack (RXGF-CCM) ..........................................................
Combustible Floor Base (RXGC-B14, 17, 21, 24) ....................
UNIT DATA
HEATING PERFORMANCE
TOTAL CAPACITY INPUT* ......
_______
MBH [kW]
TOTAL CAPACITY OUTPUT* ..
_______
MBH [kW]
DESIGN TEMP. RISE ..............
_______
°F [°C] DB
AFUE ................................................
_______
%
CALIFORNIA SEASONAL
EFFICIENCY ..................................
_______
%
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT......................................
_______
IWG
BLOWER SPEED ..........................
_______
RPM
POWER OUTPUT REQUIREMENT ..
_______
BHP
MOTOR RATING ........................
_______
HP [W]
POWER INPUT REQUIREMENT ........
_______
kW
ELECTRICAL DATA
POWER SUPPLY......................
____________ Hz
TOTAL UNIT AMPACITY................
_______
AMPS
MINIMUM WIRE SIZE ....................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ..........
_______
AMPS
CLEARANCES
FRONT SIDE 3" [76.2 mm]
RIGHT SIDE 3" [76.2 mm]
LEFT SIDE 0" [0 mm]
TOP 1" [25.4 mm]
TWO-STAGE DOWNFLOW GAS FURNACES:
RGLQ- Series 80% A.F.U.E. Input Rates 50 to 150 kBTU [15 to 44 kW] (U.S. & Canadian Models)
DOWNFLOW MODELS
DOWNFLOW WARNING: Unit design is certified for installation on non-combustible floor. A special factory supplied combustible floor sub-base is required when installing on a combustible floor. Failure to install the sub-base may result in fire, property damage and personal injury.
NOTES: May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
May be 0" [0 mm] with type B vent.May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes.
DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm]
COMBUSTIBLE FLOOR BASE DIMENSIONS
MODEL
RGLQ-
A B C D E
REDUCED CLEARANCES (IN.) [mm]
05
14 [356] 1227/32 [326] 103/8 [264]
131/8 [333]
0
4 [102]
0 1 [25] 3 [76]
6 [152]
LEFT SIDE
RIGHT
SIDE
BACK TOP FRONT VENT
SHIP. WGTS.
(LBS.) [kg]
85 [38.6]
07
171/2 [445] 1611/32 [415] 121/8 [308]
165/8 [422]
0
3 [76]
0 1 [25] 3 [76]
6 [152]
105 [47.6]
10 (A) 171/2 [445] 1611/32 [415] 121/8 [308]
165/8 [422] 0
3 [76]
0 1 [25] 3 [76]
6 [152]
115 [52.2]
10 (B)
21 [533] 1927/32 [504] 137/8 [352]
201/8 [511]
0
0
0 1 [25] 3 [76]
6 [152]
120 [54.4]
12 241/2 [622] 2311/32 [593] 155/8 [397]
235/8 [600] 0 0 0 1 [25] 3 [76]
6 [152]
140 [63.5]
15
241/2 [622] 2311/32 [593] 155/8 [397]
235/8 [600]
0 0 0 1 [25] 3 [76]
6 [152]
150 [68]
COMBUSTIBLE
FLOOR BASE
A
IN. [mm]BIN. [mm]
USE WITH
FURNACE SIZES
RXGC-B24
25 [635] 233/4 [603]
(-)GLQ-12, (-)GLQ-15
RXGC-B14
141/2 [368] 131/4 [337]
(-)GLQ-05 RXGC-B17 18 [457] 163/4 [425](-)GLQ-07, (-)GLQ-10A RXGC-B21 211/2 [546] 201/4 [514](-)GLQ-10B
C
IN. [mm]
213/4 [552]
111/4 [286] 143/4 [451] 181/4 [464]
[    ] Designates Metric Conversions
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
Rheem Sales Company, Inc. P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A. 10-13 QG FORM NO. X33-1385 REV. 1
Supersedes Form No. X33-1231
Loading...