FORM NO. X33-1385 REV. 1
Supersedes Form No. X33-1231
JOB NAME MODEL NO.
CONTRACTOR OUTDOOR UNIT MODEL NO.
ENGINEER LOCATION
SUBMITTED FOR APPROVAL RECORD ORDER NO.
DATE
FEATURES FOR RGLQ-
■ Patented heat exchanger, constructed of aluminized steel for the
maximum in corrosion resistance and thermal fatigue reliability.
■ Low profile “34 inch” [864 mm] design is lighter and easier to
handle, and leaves room for optional equipment.
■ Left or right side gas and electric inlet connections with quick,
simple change.
■ Direct spark ignition.
■ Integrated control board with humidifier and electronic air
cleaner hookups.
■ Insulated blower compartment, a two stage gas valve and a
specially designed two speed draft inducer motor make it one
of the quietest furnaces on the market today.
■ Pre-paint galvanized steel cabinet.
■ Grab-holes in doors to aid in easy door removal and replacement.
■ Compatible with single or two-stage thermostat. (For optimal
performance, two-stage thermostat recommended.)
✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test
procedures.
FIELD INSTALLED ACCESSORIES
Fossil Fuel Kit (RXPF-F01 and F02) ........................................
Filter Rack (RXGF-CCM) ..........................................................
Combustible Floor Base (RXGC-B14, 17, 21, 24) ....................
UNIT DATA
HEATING PERFORMANCE
TOTAL CAPACITY INPUT* ......
_______
MBH [kW]
TOTAL CAPACITY OUTPUT* ..
_______
MBH [kW]
DESIGN TEMP. RISE ..............
_______
°F [°C] DB
AFUE ................................................
_______
%
CALIFORNIA SEASONAL
EFFICIENCY ..................................
_______
%
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT......................................
_______
IWG
BLOWER SPEED ..........................
_______
RPM
POWER OUTPUT REQUIREMENT ..
_______
BHP
MOTOR RATING ........................
_______
HP [W]
POWER INPUT REQUIREMENT ........
_______
kW
ELECTRICAL DATA
POWER SUPPLY......................
____________ Hz
TOTAL UNIT AMPACITY................
_______
AMPS
MINIMUM WIRE SIZE ....................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ..........
_______
AMPS
CLEARANCES
FRONT SIDE 3" [76.2 mm]
RIGHT SIDE 3" [76.2 mm]
LEFT SIDE 0" [0 mm]
TOP 1" [25.4 mm]
TWO-STAGE DOWNFLOW GAS FURNACES:
RGLQ- Series
80% A.F.U.E.✝
Input Rates 50 to 150 kBTU [15 to 44 kW] (U.S. & Canadian Models)