Rheem Classic®Series Super Quiet 80
™
A.F.U.E.†Two-Stage Downflow
Gas Furnaces
FORM NO. G11-515 REV. 1
RGLQ- Series
Models with Input Rates from
50,000 to 150,000 BTU/HR
[15 to 44 kW]
(U.S. & Canadian Models)
• The Rheem Classic
®
Series Super Quiet 80
™
2-Stage line of
downflow gas furnaces is designed for installation in closets,
alcoves, utility rooms, or attics. The design is certified by CSA
International.
• Patented heat exchanger, constructed of aluminized steel for the
maximum in corrosion resistance and thermal fatigue reliability.
• Low profile “34 inch” [864 mm] design is lighter and easier to
handle, and leaves room for optional equipment.
• Left or right side gas and electric inlet connections with quick,
simple change.
• Direct spark ignition.
• Integrated control board with humidifier and electronic air
cleaner hookups.
• Insulated blower compartment, a two stage gas valve and a
specially designed two speed draft inducer motor make it one
of the quietest furnaces on the market today.
• Pre-paint galvanized steel cabinet.
• Grab-holes in doors to aid in easy door removal and
replacement.
• Compatible with single or two-stage thermostat. (For optimal
performance, two-stage thermostat recommended.)
• A variety of cooling coils and plenums designed to use with
Rheem Classic
®
Series Super Quiet 80
™
2-Stage gas furnaces
are available as optional accessories.
Air
Gas Furnaces
RGLQ Series
✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with
Department of Energy test procedures.
Annual Fuel Utilization Efficiency -
AFUE
THIS MODEL
97%78%
HIGH
MID
82% 88%
80.0%
ENER UIDE

Air
Table of Contents
RGLQ Series
2
TABLE OF CONTENTS
Standard & Optional Equipment ......................................................................3
Model Features/Physical Data & Specifications..................................................4
Model Number Identification ............................................................................5
Dimensional Data............................................................................................6
Blower Performance Data ................................................................................7
Accessories....................................................................................................8
Limited Warranty ............................................................................................9

Air
Standard & Optional Equipment
RGLQ Series
3
STANDARD EQUIPMENT
Completely assembled and wired; 2 speed induced draft blower;
high and low pressure switches; 2 stage redundant main gas control;
blower compartment door safety switch; solid state time on/time off
blower control; limit control; transformer; direct drive multi-speed
blower motor. Furnaces are equipped with cooling/heating relay
and transformer (40VA) ready for air conditioning applications.
(Please note: a thermostat is not included as standard equipment.)
Flame sensor diagnostics; fused-protection (secondary).
NOTE: Furnace is not listed for use with fuels other than natural or L.P.
(propane) gas.
The complete terms of limited and other warranties are available
at our sales office, or through local installer.
OPTIONAL EQUIPMENT
All models can be converted by a qualified Rheem professional or
local service dealer to use L.P. (propane) gas without changing
burners. Factory approved kits must be used to convert from natural
to L.P. (propane) gas and may be ordered as optional accessories.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
NOTE: For natural and L.P. (propane) gas models, direct spark ignition
is 100% lockout type.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
INTEGRATED
FURNACE
CONTROL
HEAT EXCHANGER
IN-SHOT BURNERS
DIRECT SPARK IGNITOR
REMOTE SENSOR
TWO-SPEED DRAFT
INDUCER MOTOR

Air
Model Features/Physical Data & Specifications
RGLQ Series
4
Physical Data and Specifications
U.S. and Canadian Models
• Patented heat exchanger, constructed of aluminized steel for the
maximum in corrosion resistance and thermal fatigue reliability.
• Low profile “34 inch” [864 mm] design is lighter and easier to
handle, and leaves room for optional equipment.
• Left or right side gas and electric inlet connections with quick,
simple change.
• Direct spark ignition.
• Integrated control board with humidifier and electronic air
cleaner hookups.
• Insulated blower compartment, a two stage gas valve and a
specially designed two speed draft inducer motor make it one
of the quietest furnaces on the market today.
• Pre-paint galvanized steel cabinet.
• Grab-holes in doors to aid in easy door removal and
replacement.
• Compatible with single or two-stage thermostat. (For optimal
performance, two-stage thermostat recommended.)
• A variety of cooling coils and plenums designed to use with
Rheem Classic
®
Series Super Quiet 80
™
2-Stage gas furnaces
are available as optional accessories.
Model Features
NOTES: All models are 115V, 60HZ, 1Ø. Gas connection size for all models is 1/2" [12.7 mm] N.P.T.
➀
In accordance with D.O.E. test procedures.
➁
See Conversion Kit Index for high altitude derate in U.S. applications. For Canadian applications, reference the furnace installation instructions.
[ ] Designates Metric Conversions
MODEL NUMBERS
RGLQ- SERIES
High Input–BTU–BTU/Hr [kW] ➁
Heating Capacity–BTU/Hr [kW] ➀
Low Input–BTU/Hr [kW] 35,000 [10] 52,500 [15]
Heating Capacity–BTU/Hr [kW] 28,000 [8] 41,600 [12]
Heating–Ext. Static Pressure [kPa] .10 [.025] .12 [.029] .15 [.037] .15 [.037] .20 [.05] .20 [.05]
Blower (D x W) [mm]
Motor H.P.–[W]
Speeds–Type
Motor Full Load Amps 6.8 7.1
Heating Speed–High Fire MED-LOW MED-HIGH
Heating Speed–Low Fire LOW MED-LOW LOW LOW LOW LOW
Cooling Speed HIGH HIGH
Cooling CFM @ .5" [kPa] E.S.P.
(Nominal) [L/s]
Max. E.S.P. (In. W.C.) [kPa] 0.5 [.12] 0.5 [.12]
Temperature Rise Range °F [°C]
High Input
Temperature Rise Range °F [°C]
Low Input
Max. Outlet Air Temp. °F
[°C]
Standard Filter–In.
[mm]
Approx. Shipping Weight (Lbs.)
[kg]
AFUE ➀
05EAUER
05NAUER
50,000 [15] 75,000 [22]
40,360 [12] 61,020 [18]
11 x 6
[279 x 152]
1
/2 [373]
4-PSC
1200
[566]
25-55
[13.9-30.6]
20-50
[11.1-27.8]
155
[68.3]
(1) 14 x 20
[356 x 508]
85
[39]
80.0% 80.0%
07EAMER
07NAMER
11 x 7
[279 x 178]
1
/2 [373]
4-PSC
1200
[566]
35-65
[19.4-36.1]
30-60
[16.7-33.0]
165
[78.3]
(2) 12 x 20
[306 x 508]
105
[48]
10EAMER
10NAMER
100,000 [29] 100,000 [29] 125,000 [37]
81,600 [24] 81,040 [24] 101,750 [29]
70,000 [20] 70,000 [20] 87,500 [25]
56,000 [16] 56,000 [16] 70,000 [20]
11 x 7
[279 x 178]
1
/2 [373]
4-PSC
7.1 9.5 9.5
MED-HIGH MED-HIGH MED-HIGH
HIGH HIGH HIGH
1200
[566]
0.5 [.12] 0.5 [.12] 0.5 [.12]
45-75
[25.0-41.7]
20-50
[11.1-27.8]
180
[82.2]
(2) 12 x 20
[306 x 508]
115
[52]
80.0% 80.0% 80.0%
10EBRJR
10NBRJR
11 x 10
[279 x 254]
3
/4 [559]
4-PSC
2000
[944]
30-60
[16.7-33.3]
35-65
[19.4-36.1]
180
[82.2]
(2) 14 x 20
[356 x 508]
120
[54]
12EARJR
12NARJR
11 x 10
[279 x 254]
3
/4 [559]
4-PSC
2000
[944]
35-65
[19.4-36.1]
25-55
[13.9-30.6]
180
[82.2]
(2) 14 x 20
[356 x 508]
140
[63]
15EARJR
15NARJR
150,000 [44]
121,550 [35]
105,000 [30]
84,000 [24]
11 x 10
[279 x 254]
3
/4 [559]
4-PSC
9.5
MED-HIGH
HIGH
2000
[944]
0.5 [.12]
50-80
[27.8-44.4]
30-60
[16.7-33.3]
190
[87.7]
(2) 14 x 20
[356 x 508]
150
[68]
80.0%