Rheem AFUE Upflo Horizontal Submittal Sheet

Page 1
SUBMITTAL COVER SHEET
Quantity
Unit Designation
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES: NOTES:
PRINTED IN U.S.A 01/12 QG FORM NO. M11-1640
PROJECT NAME
LOCATION
ARCHITECT
ENGINEER
CONTRACTOR
SUBMITTED BY DATE
UNIT SUMMARY
Page 2
FORM NO. X33-1438
Supersedes Form No. X33-1285 Rev. 2
JOB NAME MODEL NO.
CONTRACTOR OUTDOOR UNIT MODEL NO.
ENGINEER LOCATION
SUBMITTED FOR APPROVAL RECORD ORDER NO.
DATE
UNIT DATA
HEATING PERFORMANCE
TOTAL CAPACITY INPUT* ......
_______
MBH [kW]
TOTAL CAPACITY OUTPUT* ..
_______
MBH [kW]
DESIGN TEMP. RISE ..............
_______
°F [°C] DB
AFUE ................................................
_______
%
CALIFORNIA SEASONAL
EFFICIENCY ..................................
_______
%
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT......................................
_______
IWG
BLOWER SPEED ..........................
_______
RPM
POWER OUTPUT REQUIREMENT ..
_______
BHP
MOTOR RATING ........................
_______
HP [W]
POWER INPUT REQUIREMENT ........
_______
kW
ELECTRICAL DATA
POWER SUPPLY ..............................
_______ Hz
TOTAL UNIT AMPACITY................
_______
AMPS
MINIMUM WIRE SIZE ....................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ..........
_______
AMPS
FEATURES FOR R801T UPFLOW/HORIZONTAL
80% residential Gas Furnace CSA certified
3 way multi poise design UF / HZ
PlusOne
Diagnostics – 7 Segment LED all units
PlusOne
Ignition System – DSI for reliability and longevity
Heat exchanger is removable for improved serviceability.
Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability.
Solid doors provide quiet operation
Solid bottom
Insulated blower compartment
Low profile 34" cabinet ideal for space constrained installations
Blower shelf design – serviceable in all furnace orientations
Hemmed edges on cabinets and doors
1/4 turn door knobs for tool less access
Integrated Control board features dip switches for easy
system set up
QR code for quick access to product information from your
smart phone or tablet
Constant Torque electrically commutated motor
FIELD INSTALLED ACCESSORIES
External Bottom Filter Rack RXGF-CB ......................................
External Side Filter Rack RXGF-CD ..........................................
Indoor Coil Casing RXBC-D14A1..............................................
Indoor Coil Casing RXBC-D17A1..............................................
Indoor Coil Casing RXBC-D21A1..............................................
Indoor Coil Casing RXBC-D21B1..............................................
Indoor Coil Casing RXBC-D24A1..............................................
Solid Bottom Kit RXGB-D14......................................................
Solid Bottom Kit RXGB-D17......................................................
Solid Bottom Kit RXGB-D21......................................................
Solid Bottom Kit RXGB-D24......................................................
4" Flue Adapter RXGW-C01 ......................................................
UPFLOW/HORIZONTAL GAS FURNACE
R801T Series 80% A.F.U.E. Input Rates 50 to 125 kBTU [14.7 to 36 kW]
Page 3
MODEL R801T-
A B C D E F
REDUCED CLEARANCE (IN.) [mm]
SHIP
WGTS.
(LBS.) [kg]
LEFT
SIDE
RIGHT
SIDE
BACK TOP FRONT VENT
050 141/2 [356] 1227/32 [326] 105/8 [270]
111/2 [292] 17/8 [48] 0
4 [102]
0 1 [25] 3 [76]
6 [152]
85 [38.6]
075 171/2 [445] 1611/32 [415] 123/8 [314]
151/2 [381] 21/2 [64] 0
3 [76]
0 1 [25] 3 [76]
6 [152]
105 [47.6]
100 211/2 [533] 1927/32 [504] 141/8 [359]
181/2 [470] 21/2 [64] 0 0 0 1 [25] 3 [76]
6 [152]
120 [54.4]
125 241/2 [622] 2311/32 [593] 157/8 [403]
221/2 [559] 21/2 [64] 0 0 0 1 [25] 3 [76]
6 [152]
140 [63.5]
NOTES: May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter. 4" adapter included with (-)801P units.
May be 0" [0 mm] with type B vent.May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and in accordance with local codes.
[ ] Designates Metric Conversions
Unit Dimensions
Horizontal Application
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED FOR INSTALLATION
ON ITS BACK, WITH ACCESS DOORS
FACING UPWARDS.
Upflow Application
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
Rheem Sales Company, Inc. P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A. 7-14 QG FORM NO. X33-1438
Supersedes Form No. X33-1209
Loading...