Rheem Advantage Plus User Manual

ADVANTAGEPLUS™FROM RHEEM-RUUD WATER HEATERS
95% Efficiency!
Get drastically lower operating costs
with sealed-combustion!
Meets SCAQMD Rule 1146.2 and TNRCC Low NOx requirements.
Commercial water heaters
from Rheem-Ruud
AdvantagePlus
from Rheem-Ruud
The sealed-combustion gas fired water heater line that’s perfect for commercial applications needing
LARGE VOLUMES of LOW-COST hot water.
95% efficient sealed-combustion design: Saves
hundreds, even thousands, of dollars in annual operating costs.
No chimney required – Vents up to 40 feet using
3" Schedule 40 PVC, CPVC or ABS pipe.*
* 100,000 and 130,000 BTU/hour models are certified to vent with 2˝ Schedule PVC,
CPVC or ABS Pipe.
Low-weight design: Rust-proof nonferrous outer jacket
and nonmetallic trim components make AdvantagePlus much lighter and easier to maneuver than comparable competitive models.
Rugged and corrosion-resistant 316L stainless steel
tank ensures long life. No anode rod is needed.
High-efficiency 90/10 cupronickel heat exchanger
features the same highly durable, corrosion-resistant material commonly used for boiler heat exchangers.
Whisper-quiet design: The burner and
blower assembly is located below eye level and behind an enclosure made of ABS plastic, resulting in an ultra-quiet operation.
Easy to service: All components and
controls are conveniently located behind an easy-to-remove, front­mounted access panel.
Storage capacities from 45 to
119 gallons.
Inputs from 100,000 to 199,000
BTU/hour.
Large volumes fast: 119-gallon,
199,000 BTU/hour model delivers 314 gallons of hot water in the first hour, while needing only 31 minutes to fully recover.
Saves energy: No burning pilot light.
Meets low NOx requirements in
California (SCAQMD Rule 1146.2) and Texas (TNRCC).
No chimney required: 85 equivalent
feet of vent length, using plastic pipe.
Self-diagnostic electronic control: Features digital
readout of water temperature set point and differential.
Minimizes heat loss: 2" polyurethane foam insulation
shrinks heat loss to less than 0.5° F per hour (R-17 rating).
Wide temperature-setting range: 70°F to 160°F.
(180°F on booster models).
Zero clearance to any combustible surface.
Easy equipment servicing through highly accessible
front cover (24" service clearance recommended).
The ultimate in heavy-duty durability, high-tech efficiency and user-friendly flexibility.
Heat Exchanger/ Combustion Chamber
Control Well and E.C.O. Air Inlet Connector Gas Valve Combustion Blower Gas Burner Gas Inlet Nipple 1/2” Hot Surface Ignitor Flame Probe Exhaust Outlet Connector Control Board Vent Over-Temp
Reset Switch Exhaust Elbow and Drain Pressure Switch Transformer Condensate Connector Hose Condensate Connector
Rheem-Ruud AdvantagePlus
RECOVERY CAPACITIES
EMPERATURE RISE - DEGREES F - GALLONS PER HOUR
ODEL
M NUMBER CAPACITY INPUT EFFICIENCY 40° 50° 60° 70° 80° 90° 100° 110° 120° 130° 140°
E45-100 45 100,000 95% 288 230 192 165 144 128 115 105 96 N/A N/A
H
E45-130 45 130,000 95% 374 299 249 214 187 166 150 136 125 N/A N/A
H HE80-130 80 130,000 95% 374 299 249 214 187 166 150 136 125 N/A N/A HE119-130 119 130,000 95% 374 299 249 214 187 166 150 136 125 N/A N/A
E45-160 45 160,000 95% 461 368 307 263 230 205 184 167 154 142 132
H
E80-160 80 160,000 95% 461 368 307 263 230 205 184 167 154 N/A N/A
H HE119-160 119 160,000 95% 461 368 307 263 230 205 184 167 154 N/A N/A
E45-199 45 199,000 95% 573 458 382 327 286 255 229 208 191 176 164
H
E80-199 80 199,000 95% 575 460 384 329 288 256 230 209 192 N/A N/A
H HE119-199 119 199,000 95% 575 460 384 329 288 256 230 209 192 N/A N/A
ecovery rating is based on a recovery efficiency obtained in an UL laboratory.
R This model exceeds the minimum NAECA energy factor requirements of ASHRAE 90.1b-1992.
MAXIMUM DELIVERY (in gallons) (Includes useable storage and recovery for indicated times)
ODEL TEMP. 5 10 15 20 30 45 123MIN. TO RECOVER
M NUMBER CAPACITY INPUT EFFICIENCY RISE MIN. MIN. MIN. MIN. MIN. MIN. HR. HR. HR. CONTENTS
E45-100 45 100,000 95% 100° 41 51 60 70 89 118 147 262 377 23
H HE45-130 45 130,000 95% 100° 44 56 69 81 106 144 181 331 481 18 HE80-130 80 130,000 95% 100° 68 81 93 106 131 168 206 355 505 32
E119-130 119 130,000 95% 100° 96 109 121 134 159 196 234 383 533 48
H
E45-160 45 160,000 95% 100° 47 62 78 93 124 170 216 400 584 15
H HE80-160 80 160,000 95% 100° 71 87 102 117 148 194 240 424 609 26 HE119-160 119 160,000 95% 100° 99 115 130 145 176 222 268 452 637 39
E45-199 45 199,000 95% 100° 51 70 89 108 146 203 261 490 719 12
H HE80-199 80 199,000 95% 100° 75 94 114 133 171 229 286 516 747 21 HE119-199 119 199,000 95% 100° 103 122 141 161 199 257 314 544 774 31
T
DIMENSIONAL INFORMATION (All dimensions shown in inches)
MODEL APPROX. SHIPPING NUMBER HEIGHT WIDTH DEPTH VENT WEIGHT (LBS.)
HE45-100 42 23-1/2 32 2 HE45-130 42 23-1/2 32 2 HE45-160 42 23-1/2 32 3 175 HE45-199 42 23-1/2 32 3 175 HE80-130 72 23-1/2 32 2 HE80-160 72 23-1/2 32 3 235 HE80-199 72 23-1/2 32 3 235 HE119-130 73 27 36 2 HE119-160 73 27 36 3 405 HE119-199 73 27 36 3 405
Models with inputs of 100,000 kBtu and 130,000 kBtu are certified to vent with 2” Schedule 40 PVC, CPVC or ABS pipe.
175 175
235
405
CLEARANCES TO COMBUSTIBLES
MODEL REAR /
NUMBER SIDES FRONT* TOP
HE45-100 00 0 HE45-130 00 0 HE45-160 00 0 HE45-199 00 0 HE80-130 00 0 HE80-160 00 0 HE80-199 00 0 HE119-130 00 0 HE119-160 00 0 HE119-199 00 0
* 24" service clearance recommended
Commercial water heaters
from Rheem-Ruud
®
Rheem-Ruud AdvantagePlus
LIMITED WARRANTY
This product features a three-year limited warranty against tank leaks. Please refer to Commercial Warranty Information brochure for complete warranty information.
CERTIFICATIONS AND RATINGS
EFFICIENCY
The water heaters are UL/ULC listed and exceed the minimum efficiency requirements of current ASHRAE Standards.
SAFETY AND CONSTRUCTION
All water heaters are supplied with an AGA/ASME rated temperature and pressure relief valve. The control panel is an integrated solid state temperature and ignition control device with integral diagnostics, LED fault display capability and a digital display of temperature settings.
CERTIFIED FOR A 150 PSI MAXIMUM WORKING PRESSURE.
In keeping with its policy of continuous progress and product improvement, Rheem-Ruud reserves the right to make changes without notice.
Commercial water heaters
from Rheem-Ruud
Rheem Water Heating • 101 Bell Road, Montgomery, AL 36117-4305 800-621-5622 • sales@rheem.com • www.rheem.com
Rheem Canada Ltd./Ltée • Water Heater Division • 128 Barton Street West, Hamilton, Ontario L8N 3P3
Not all models are available in Canada.
Printed in U.S.A 05/07 WP RR103 Rev. 6
Loading...