Rheem 27 874 Series, 874 Series Owner's Manual And Installation Instructions

Page 1
Page 2
PATENTS
This water heater may be protected by one or more patents or registered designs in the name of
Rheem Australia Pty Ltd or Paloma Industries Ltd.
Rheem New Zealand Pty Ltd is the supplier of the Rheem range of electronic continuous flow gas water heaters,
manufactured by Paloma Industries Ltd, a world leader in water heater technology and manufacture.
® Registered trademark of Rheem New Zealand Pty Ltd.
™ Trademark of Rheem New Zealand Pty Ltd.
Note: Every care has been taken to ensure accuracy in preparation of this publication.
No liability can be accepted for any consequences, which may arise as a result of its application.
Warning: Upon completion of the installation and commissioning of the water heater, leave this guide
with the householder or a responsible officer. DO NOT
leave this guide inside of the cover of the water heater, as it may interfere with the safe operation of the water heater or ignite when the water heater is turned on.
Page 3
3
CONTENTS
HOUSEHOLDER - We recommend you read pages 4 to 73.
The other pages are intended for the installer but may be of interest.
About Your Water Heater ............................................................................................................ 4
Temperature Control ................................................................................................................... 9
Temperature Control – Standard ............................................................................................. 10
Temperature Control – Deluxe ................................................................................................. 20
Save A Service Call ................................................................................................................... 39
Installation – Water Heater ....................................................................................................... 42
Connections – Plumbing .......................................................................................................... 55
Connections – Electrical ........................................................................................................... 57
Installation – Controllers .......................................................................................................... 58
Commissioning.......................................................................................................................... 65
Draining The Water Heater ....................................................................................................... 72
Water Supplies........................................................................................................................... 72
Warranty ..................................................................................................................................... 73
Page 4
4
ABOUT YOUR WATER HEATER
MODEL TYPE
The Rheem® electronic continuous flow gas water heater model you have chosen is for outdoor installation only. This model has an extended warranty (refer to “Warranty” on page 73).
The water heater has a preset outlet temperature setting of:
874 series 55°C
Notes:
.
The 874 series water heater may be installed as an in-series gas booster water heater to a solar preheat
water heater. For information relating to the function and operation of the solar water heater, refer to the Owner’s Guide and Installation Instructions supplied with the solar water heater.
When installed as a gas booster to a solar preheater, the 874 series water heater:
Can deliver water at temperatures up to 75°C for a Premier Loline and Loline pumped system and a
Hiline thermosiphon system and possibly higher temperatures from a Premier Hiline thermosiphon system.
During periods of low solar energy gain, will boost the water temperature automatically to a minimum
75°C when required.
WATER HEATER OPERATION
The water heater operates automatically, heating water as it passes through the water heater. When a hot tap is opened, the gas burners ignite to provide immediate heating of the water. The heat produced by the burner is transferred to the water through the heat exchanger. The water is heated to a constant temperature by the automatic adjustment of the gas supply to the burner to suit the water flow rate (refer to
“Temperature Control” on pages 9 to 38). The gas burners extinguish
when the hot tap is closed.
Automatic safety controls are fitted to the water heater to provide safe and efficient operation.
GAS BOOSTING FOR A SOLAR WATER HEATER
Water stored in the solar storage tank passes through the gas booster water heater when a hot tap is opened. The gas booster water heater is for heating water at times of low solar energy gain, such as during cloudy or rainy weather, or during winter months.
Solar heated water can reach temperatures up to 75°C for a Premier Loline and Loline pumped system and a Hiline thermosiphon system and possibly higher for a Premier Hiline thermosiphon system. The gas booster water heater operates automatically. When the solar heated water temperature is 58°C or higher, the flow passes through the gas booster water heater without boosting. When the solar heated water temperature is below 58°C, the gas booster water heater operates, and heats the water to a minimum temperature of 75°C.
Page 5
ABOUT YOUR WATER HEATER
5
MAINS PRESSURE
The water heater is designed for direct connection to the mains water supply. If the mains supply pressure in your area exceeds that shown on page 44, a pressure limiting valve must be fitted. The supply pressure should be greater than 140 kPa for the rated flow and performance to be achieved.
HOW HOT SHOULD THE WATER BE?
The water heater may be installed with one or more user adjustable temperature controllers, which allow you to choose the most suitable temperature for your hot water needs (refer to “Temperature Control” on page 9).
If a controller is not installed, the water heater heats the water to the factory preset outlet temperature setting. The preset outlet temperature setting is:
874 series 55°C
Note: The preset outlet temperature setting of this water
heater cannot be adjusted by the householder. The setting can only be adjusted by the installer, or an Accredited Rheem Service Centre.
If this water heater is installed as part of a solar water heater system, the installer should check, and if required, adjust the preset outlet temperature setting of an 874 series water
heater to 75°C. A tempering valve must be installed as per
AS/NZS3500.4 requires you to do so.
Warning: Temperature controllers must not be fitted to this water heater (874 series) as part of a solar
water heater system. This is because the water can be supplied at a temperature much higher than the controller temperature setting. If a solar preheater has been installed to an existing water heater installation,
then all controllers must be disconnected and removed.
If this water heater is installed as part of a solar water heater system, the system can deliver water at temperatures from 58°C up to 75°C and possibly higher depending upon the model of solar water heater installed.
HOTTER WATER INCREASES THE RISK OF SCALD INJURY
This water heater can deliver water at temperatures which can cause scalding. Check the water temperature before use, such as when entering a shower or filling a bath or basin, to ensure it is suitable for the application and will not cause scald injury.
It may be required by local regulations that supplying hot water to an early childhood centre, school, nursing home or a facility for young, aged, sick or disabled people. An approved temperature limiting device supplying a fixed temperature of 45°C or less, to be fitted into the hot water piping to the bathroom and ensuite when an 874 series water heater is installed to reduce risk of scald injury. If no controllers are installed, and the 874 series preset outlet temperature setting has not been adjusted below 55°C, or if a Kitchen controller is installed, and there is no temperature limiting device, the 874 series supply temperature can still potentially cause a scald.
The factory preset temperature setting of an 874 series water heater will not deliver temperatures exceeding 55°C. There is no requirement in AS/NZS 3500.4 to fit a temperature limiting device unless the water heater is supplying hot water to an early childhood centre, school, nursing home or a facility for young, aged, sick or disabled people.
maximum Kitchen controller
temperature setting 874 series
maximum recommended supply
temperature to bathrooms and
ensuites. maximum Bathroom controller temperature setting 874 series
Minimum Kitchen and Bathroom
controller temperature setting
Page 6
ABOUT YOUR WATER HEATER
6
WARNING
This water heater is only intended to be operated by persons who have the experience or the knowledge and the capabilities to do so. This water heater is not intended to be operated by persons with reduced physical, sensory or mental capabilities i.e. the infirm, or by children. Children should be supervised to ensure they do not interfere with the water heater.
The water heater uses 240 Volt AC electrical power for operation of the control systems and the combustion fan. The removal of the front panel will expose 240 V wiring. It must only be removed by an authorised or qualified person.
The power lead from the water heater must be plugged into a weatherproof electrical outlet. Take care not to touch the power plug with wet hands.
SAFETY
This water heater is supplied with temperature sensors, a FlameSafe® protection system and a pressure relief valve. These devices must not be tampered with or removed. The water heater must not be operated unless each of these devices is fitted and is in working order.
If the power supply cord or plug is damaged, it must be replaced by an authorised person in order to avoid a hazard. The power supply cord and plug must be replaced with a genuine replacement part available from Rheem. Phone your nearest Rheem Service Department or Accredited Service Centre to arrange for an inspection.
The warranty can become void and serious hazards may result
if relief valves or other safety devices
are tampered with or if the installation is not in accordance with these instructions.
Do not store flammable or combustible materials near
the water heater. Flammable liquids (such as petrol), newspapers and similar articles must be kept well away from the water heater and the flue terminal.
Do not use aerosols, stain removers and household
chemicals near the water heater whilst it is working. Gases
from some aerosol sprays, stain removers and household chemicals become corrosive when drawn into a flame.
Do not store swimming pool chemicals, household
cleaners, etc., near the water heater.
Do not place anything on top of the water heater or in
contact with the flue terminal. Ensure the flue terminal is not obstructed in any way at any time.
Do not use Propane / Butane gas mixtures in a Propane model. A Propane model is designed to operate
on Propane only. The use of Propane / Butane mixture, such as automotive LPG fuel, in a Propane model is unsafe and can cause damage to the water heater.
GOING ON HOLIDAYS
If you are going on holidays, it is not necessary to turn the water heater off. If it is necessary to turn off the water heater, refer to “To Turn off the Water Heater” on page 7.
Page 7
ABOUT YOUR WATER HEATER
7
TO TURN OFF THE WATER HEATER
If it is necessary to turn off the water heater:
Turn off the controllers(s) (if fitted) by pressing the on / off button.
The light in the on / off button will go out and the priority light (standard controller) or the ACTIVE light (Deluxe controller), if it is on, will go out.
Switch off the electrical supply at the power outlet to the water heater if there is no risk of freezing
conditions occurring (refer to note below).
Close the gas isolation valve at the inlet to the water heater.
Close the cold water isolation valve at the inlet to the water heater.
Note: If there is a risk of freezing conditions, the electrical supply to the water heater should not be switched
off unless the water heater is drained, otherwise damage could result (refer to “Frost Protection” on page 8 and “Draining the Water Heater” on page 8).
TO TURN ON THE WATER HEATER
Screw in the drain plugs at the cold water inlet and hot water outlet of the water heater if the water
heater has been drained.
Open all of the hot taps in the house (don’t forget the shower).
Open the cold water isolation valve fully at the inlet to the water heater.
Air will be forced out of the taps.
Close each tap as water flows freely from it.
Open the gas isolation valve fully at the inlet to the water heater.
Plug in the power supply cord at the power outlet.
Switch on the electrical supply at the power outlet to the water heater.
Turn on a controller, if one is fitted, by pressing the on / off button.
The light in the on / off button and the priority light (standard controller) or ACTIVE light (Deluxe controller) will both glow.
The water heater will operate automatically when you open a hot tap.
HOW DO I KNOW IF THE WATER HEATER IS INSTALLED CORRECTLY?
Installation requirements are shown on page 52. The water heater must be installed by an authorised person. In New Zealand the installation must comply with Standards AS/NZS 3500.4 and NZS 5261 and all local codes and regulatory authority requirements.
Warning: Temperature controllers must not be fitted to this water heater (874 series) as part of a solar
water heater system because water at a temperature much higher than the controller setting can be delivered. If a solar preheater heater has been installed to an existing water heater installation, then all
controllers must be disconnected and removed.
The pipe work between the solar storage tank (if one is installed) and the gas booster water heater has a
minimum recommended pipe size of DN20, MUST BE
of copper and be fully insulated in accordance with the requirements of AS/NZS 3500.4. The insulation must be weatherproof and UV resistant if exposed. The insulation must be fitted up to the connections on both the solar storage tank and the gas booster water heater.
DOES THE WATER CHEMISTRY AFFECT THE WATER HEATER?
The water heater is suitable for most public water supplies; however some water chemistries may have
detrimental effects on the heat exchanger and fittings. If you are in a known harsh water area you must
read page 72
. If you are not sure, have your water chemistry checked against the conditions described on
page 72.
Page 8
ABOUT YOUR WATER HEATER
8
HOW LONG WILL THE WATER HEATER LAST?
There are a number of factors that will affect the length of service the water heater will provide. These include the water chemistry, the water pressure, temperature (inlet and outlet) and the water usage pattern. However, your water heater is supported by a comprehensive warranty (refer to page 73).
GENERAL MAINTENANCE
The jacket of the water heater can be cleaned with a soft cloth and warm mild soapy water. Under no circumstances should abrasive materials or powders be used.
SERVICING
For safe and efficient operation, the water heater should be serviced annually by your nearest Rheem Accredited Service Centre. Only genuine replacement parts should be used on this water heater.
Warning: Servicing of a gas water heater should only be carried out by authorised personnel.
FROST PROTECTION
The water heater has a frost protection system. The frost protection system will protect the water heater from damage, by preventing ice forming in the waterways of the water heater, in the event of freezing conditions occurring.
Notes:
The frost protection system will be rendered inoperable if electrical power is not available at the water
heater. Damage caused by freezing due to the unavailability of power at the water heater is not covered by warranty (refer to “Warranty Exclusions” on page 74).
If it is necessary to switch the power off to the water heater and there is a risk of freezing, then it is
necessary to drain the water heater (to “Draining the Water Heater” on page 72).
Pipe work to and from the water heater must be adequately insulated to prevent freezing.
The water heater is not suitable for installation in areas where the ambient temperature falls below -20ºC
(including wind chill factor).
Refer to “Warranty Exclusions” on page 74.
DRAINING THE WATER HEATER
Turn off the water heater (refer to “Turn Off The Water Heater” on page 71).
Open a hot tap (preferably the shower outlet).
Unscrew the two drain plugs, one each at the cold water inlet and hot water outlet, on the underside of
the water heater.
Water will drain from the water heater.
When water stops flowing from the water heater, close the hot tap.
Note: It is recommended not to screw the drain plugs back in, until the water heater is to be turned on again.
Page 9
9
TEMPERATURE CONTROL
CONTROLLERS
The Rheem 874 series can be installed with Rheem controllers to enable the user to control the temperature of the delivered water from the outlet of the water heater. There are two families of Rheem controllers suitable for installation with this water heater. These are the standard controllers and the Deluxe controllers.
Standard Controllers
There are three types of standard controller. They are the Kitchen controller (Rheem PN 299853), Bathroom1 controller (Rheem PN 299854) and the Bathroom2 controller (Rheem PN 299855). The standard controllers are suitable for use on all 874 and 876 series models.
The standard controllers are identified by a ‘K’ (Kitchen controller), ‘B1’ (Bathroom1 controller) or ‘B2’ (Bathroom2 controller) located on the front bottom left hand corner of the standard controller.
Deluxe Controllers
There are three types of Deluxe controller. They are the Kitchen Deluxe controller (Rheem PN 299861), Bathroom1 Deluxe controller (Rheem PN 299862) and the Bathroom2 Deluxe controller (Rheem PN 299863).
The Deluxe controllers are identified by a ‘K’ (Kitchen Deluxe controller), ‘B1’ (Bathroom1 Deluxe controller) or ‘B2’ (Bathroom2 Deluxe controller), located under the front panel, to the bottom left hand corner adjacent to the BATH FILL VOLUME label.
The Deluxe controllers offer additional functions to the standard controllers. These are:
An assistance call function, which provides a voice prompt when pressed and will sound on all
controllers. This is useful should a family member require assistance when in the bathroom.
A Bath Fill mode, which is designed to allow the water heater to deliver a selected volume of water at a
selected temperature. Bath filling takes place when the hot tap is opened. When the set volume has been delivered, the water flow from the water heater ceases. Refer to “Bath Fill Mode” on page 30.
Note: The bath level should be monitored periodically while this function is in use to avoid the possibility
of the bath overflowing. The Bath Fill mode should also be used with caution until you are familiar with its operation.
Warning: Baths should not be left unattended whenever young children are present.
Warning: Temperature controllers must not be fitted to this water heater (874 series) as part of a solar
water heater system. This is because the water can be supplied at a temperature much higher than the controller temperature setting. If a solar preheater has been installed to an existing water heater installation,
then all controllers must be disconnected and removed.
Notes:
Where more than one controller is installed, the second or third controller must be of the same family.
A standard controller can only be installed with another standard controller(s) and a Deluxe controller
can only be installed with another Deluxe controller(s). A standard controller(s) and a Deluxe controller(s) cannot be connected to the same water heater.
One, two or three controllers can be installed. Only one of each type of controller can be connected to
the water heater. Therefore, a maximum of three controllers only can be connected to each water heater.
A Bathroom2 controller can only be installed if a Bathroom1 controller is installed and a Bathroom2
Deluxe controller can only be installed if a Bathroom1 Deluxe controller is installed.
Other manufacturers’ controllers are not suitable to and cannot be installed with this water heater.
Page 10
10
TEMPERATURE CONTROL – STANDARD
STANDARD CONTROLLER FUNCTIONS
If one or more controllers are installed, at least one must be on for the water heater to operate. If all controllers are off, the water heater will only deliver cold water.
on / off button – This button must be pressed once to turn on the controller.
A controller cannot be turned on if water is flowing from a hot tap.
To turn off a controller, press the on / off button once. The light will go out.
A controller can be turned off whilst water is flowing.
on / off operating light – The light in the on / off button will glow when the controller is turned on.
The light will go out when the controller is turned off.
priority light – This light will glow on a controller when that controller has priority.
The Bathroom controller(s), if they are turned on, have priority over the Kitchen controller.
Priority means that controller has control of the water heater temperature setting.
The water temperature setting can only be adjusted by the controller that has priority.
in use light – This light will glow on all controllers, whether they are on or off, when hot water is
flowing, regardless of which controller has priority.
display panel The current temperature setting is displayed on all controllers (whether hot water is
flowing or not), when any controller is on.
If all controllers are off, then the display remains blank.
The water volume can also be displayed on the Kitchen controller. The x10l symbol glows when the water volume is displayed.
i (up button) – The up button increases the temperature setting (refer to “Temperature Adjustment –
Standard Controller” on page 13).
j (down button) – The down button decreases the temperature setting (refer to “Temperature
Adjustment – Standard Controller” on page 13).
water volume button (Kitchen controller only) – This feature enables an alarm to sound when a set volume
of water has flowed through the water heater (refer to “Water Volume Function –
Standard Controller” on page 18).
water volume operating light – The light in the water volume button will glow when the water volume button
is pressed and the water volume mode is turned on.
The light will go out when the water volume button is pressed and the water volume mode is turned off.
water volume symbol – The x10l symbol below the display panel glows when the water volume mode is
turned on and the water volume is displayed.
Page 11
TEMPERATURE CONTROL – STANDARD
11
STANDARD CONTROLLER
int e g rit y
Note: water volume button, water volume operating light and water volume symbol are on the Kitchen
controller only.
SILENCING A CONTROLLER – STANDARD
The controller emits a sound whenever a button is pressed. This sound can be turned off to provide silent operation.
To turn off the sound:
Press the on / off button, to deactivate the controller (on / off light is off).
Press and hold the up (i) button.
Press the on / off button, whilst the up (i) button is pressed.
The sound for the controller is deactivated. Repeat this procedure on the other controllers if you wish to deactivate their sound. To restore the sound, repeat this procedure.
i up
button
j down
button
on / off
button
on / off
operating light
controller type
K = Kitchen B1 = Bathroom1 B2 = Bathroom2
water volume
operating light
display panel
water volume
button
water volume
symbol
in use light
priority light
Page 12
TEMPERATURE CONTROL – STANDARD
12
TEMPERATURE SETTINGS – STANDARD CONTROLLER
The temperature settings of each type of controller are:
Bathroom1 & 2 37°C to 48°C (in 1°C increments), 50°C
Kitchen 37°C to 48°C (in 1°C increments), 50°C*, 55°C
Temperature settings
37 38 39 40 41 42 43 44 45 46 47 48 50 55
warm average hot shower hot very hot
The installation of a Bathroom controller(s) only (i.e. no Kitchen controller) limits the temperature setting of the water heater to a maximum of:
874 series 50ºC
Regardless of the preset outlet temperature setting of the water heater.
The installation of a Kitchen controller will allow a maximum temperature setting of:
874 series 55ºC
Regardless of the preset outlet temperature setting of the water heater.
If controllers are not installed, the water heater defaults to the preset outlet temperature setting. This may be up to:
874 series 55°C
Refer to “How Hot Should The Water Be?” on page 5.
If a building is fitted with a temperature limiting device to ablution areas, and an 874 series water heater is installed with a separate untempered hot water line to the kitchen, laundry or other non-ablution areas, the kitchen controller will be able to display temperatures up to 55°C, however the tempered water at ablution areas may be lower. However, the maximum water temperature which can be delivered to the hot water outlets in these locations is determined by the preset temperature setting of the temperature limiting device. If fitted, this is usually 55°C; however the temperature setting of the temperature limiting device will determine the outlet temperature.
To enable the delivery of water temperatures above 55°C (e.g. when used as a Solar Booster), the water heater preset temperature will need increased. To supply water above 55°C to the kitchen, laundry or other non-ablution area, a separate untempered supply must be installed from the water heater to the hot water outlets in these locations.
Page 13
TEMPERATURE CONTROL – STANDARD
13
TEMPERATURE ADJUSTMENT – STANDARD CONTROLLER
A controller must be on and have priority to be able to adjust the temperature setting.
The temperature adjustment is made by pressing the up (i) button or down (j) button.
The maximum temperature setting for the controllers are:
Kitchen Bathroom
874 series 55°C 50°C
Each press of the up (i) button will increase the temperature setting by one increment.
Pressing and holding the up (i) button will scroll the temperature setting up to a maximum 43°C if there
is hot water flowing or 45°C if there is no hot water flowing.
From the 45°C setting, the up (i) button must be pressed once for each increase in temperature
increment.
The temperature setting cannot be increased above 43°C whilst hot water is flowing.
The minimum temperature setting for each type of controller is 37°C.
Each press of the down (j) button will decrease the temperature setting by one temperature increment.
Pressing and holding the down (j) button will scroll down the temperature setting.
The temperature setting can be decreased from any temperature setting whether the hot water is flowing
or not.
Page 14
TEMPERATURE CONTROL – STANDARD
14
KITCHEN CONTROLLER – STANDARD
The Kitchen controller allows the user to select the temperature setting for the hot water to be used in the kitchen and laundry. It has a minimum temperature setting of 37°C and a maximum temperature setting of:
874 series 55ºC
The Kitchen controller does not have priority if a Bathroom controller is on.
Notes on the Kitchen controller:
The controller cannot be turned on whilst a hot tap is open.
The Kitchen controller must be on and have priority in order to adjust the temperature setting on the
Kitchen controller.
The Bathroom controller(s) can be turned off from the Kitchen controller.
Press and hold the on / off button on the Kitchen controller for three seconds.
This turns off all the controllers and the displays go blank.
If hot water is flowing from a hot tap, it will go cold.
inte grity
Kitchen Controller
Page 15
TEMPERATURE CONTROL – STANDARD
15
To operate the Kitchen controller:
1. Turn off the Bathroom controller(s)
If a temperature setting is displayed and the priority light is not glowing, it is necessary to turn off the
Bathroom controller(s) to gain priority.
Refer to the notes on the Kitchen controller on page 14.
2. Turn on the Kitchen controller
Press the on / off button.
The on / off operating light and the priority light will both glow.
The Kitchen controller temperature setting will be displayed. This is the lower of the previous setting and:
874 series 50ºC
3. Select the temperature setting
Press the up (i) button or down (j) button.
Refer to “Temperature Adjustment – Standard
Controller” on page 13.
The selected temperature setting will be displayed on all controllers.
4. Open the hot tap.
The in use light will glow on all controllers.
5. Close the hot tap.
The in use light will go out on all controllers, if no other hot tap is open.
6. Turn off the Kitchen controller
Press the on / off button.
The priority light and on / off operating light will go out and the temperature display will go blank.
Important: Turn off the Kitchen controller after hot water usage is finished in the kitchen and / or laundry. Refer to Important
note for Bathroom controllers on page 16.
water
volume
on off
check
hot water
temperature
before use
50
°C
priority
in use
x10l
5
5
°C
priority
in use
x10l
5
5
°C
priority
in use
x10l
5
5
°C
priority
in use
x10l
water
volume
on off
check
hot water
temperature
before use
°C
priority
in use
x10l
Page 16
TEMPERATURE CONTROL – STANDARD
16
BATHROOM CONTROLLERS – STANDARD
The Bathroom controller(s) allows the user to select the temperature setting for the hot water to be used in the bathroom. They have a minimum temperature setting of 37°C and a maximum temperature setting of:
874 series 50ºC
The Bathroom controllers operate in tandem. Whenever an operation is selected on one Bathroom controller, it is also set on the other Bathroom controller. The Bathroom controllers automatically have priority if they are on.
Important: It is important to turn on the Bathroom controller before opening a hot tap in the bathroom
(priority is automatically gained). If the Bathroom controller is not on and the Kitchen controller is on (has priority), then it is possible to receive water at a temperature higher than expected from a hot tap in the bathroom. This temperature could be up to:
874 series 55ºC if a temperature limiting device is installed in the hot pipe to the
bathroom, or up to 55°C if a temperature limiting device is not installed.
Notes on the Bathroom controllers:
The controller cannot be turned on whilst a hot tap is open.
When a Bathroom controller is turned on, it gains priority from the Kitchen controller.
The Bathroom controller must be on in order to adjust the temperature setting on the Bathroom
controller.
The Kitchen controller can be turned off from a Bathroom controller.
Press and hold the on / off button on a Bathroom controller for three seconds.
This turns off all the controllers and the displays go blank.
If hot water is flowing from a hot tap, it will go cold.
Warning: It is advised to leave the Bathroom controller on after hot water usage is finished in the
bathroom. Turning off a controller in one bathroom will also turn off the controller in the other bathroom. The Kitchen controller will gain priority if it is on and the temperature setting can be up to:
874 series 55°C
If a hot tap is open in another bathroom, the water will be delivered at this temperature.
int e grit y
Bathroom Controller
Page 17
TEMPERATURE CONTROL – STANDARD
17
check
hot water
temperature
before use
on off
40
°C
priority
in use
42
°C
priority
in use
42
°C
priority
in use
42
°C
p
riority
in use
To operate a Bathroom controller:
1. Turn off the Kitchen controller
If a temperature setting is displayed and the priority light is not glowing, it is advised to turn off the
Kitchen controller.
Refer to the notes on the Bathroom controllers on page 16.
2. Turn on the Bathroom controller
Press the on / off button.
The on / off operating light and the priority light will both glow.
The temperature setting of 40°C will be displayed.
3. Select the temperature setting
Press the up (i) button or down (j) button.
Refer to “Temperature Adjustment – Standard Controller”
on page 13.
The selected temperature setting will be displayed on all controllers.
4. Open the hot tap
The in use light will glow on all controllers.
5. Close the hot tap
The in use light will go out on all controllers, if no other hot tap is open.
It is advised not to turn off the Bathroom controller(s).
Refer to the warning in the notes on page 16.
Page 18
TEMPERATURE CONTROL – STANDARD
18
WATER VOLUME FUNCTION – STANDARD CONTROLLER
The water volume function is designed to warn, by a beeping sound, that a certain volume of water has been
delivered from the water heater. It does not stop either the flow of or the heating of water. This function
is particularly useful if a bath is being filled, or measuring the water consumed by the use of a shower.
The water volume function can only be set by the Kitchen controller. Refer to the notes on the water volume
function on page 19.
To operate the water volume alarm:
1. Turn on the water volume alarm
Press the water volume button.
The water volume operating light will glow.
The current set water volume (in litres divided by 10) will be displayed and the x10l indicator will also glow.
Eg. The factory preset water volume of 180 litres is shown as 18 x10l.
2. Adjust the water volume setting (if necessary)
To adjust the water volume setting, press the
up (i) button to increase the water volume or the down (j) button to decrease the water volume.
Each press of the up (i) button or down (j) button will change the water volume setting by 10 litres.
Pressing the up (i) button or down (j) button continuously will scroll the water volume setting.
Fifteen seconds after the water volume has been selected, the water volume operating light will start to flash and the selected water volume is set.
The water volume operating light will continue to flash until the alarm sounds.
A maximum of 500 litres (50 and x10l displayed) and a minimum of 10 litres (1 and x10l displayed) can be set
with the water volume alarm.
3. Set the water temperature
Turn on the controller for the room where the hot water is
to be used.
Gain priority (if using the Kitchen controller).
Select the temperature setting.
4. Open the hot tap
The in use light will glow on all controllers.
Measurement of the water flow at the water heater will commence when a hot tap is open and the water volume operating light is flashing.
The alarm will sound when the set volume of water has passed through the water heater.
water
volume
on
off
check
hot water
temperature
before use
18
°C
priority
in use
x10l
water
volume
on
off
check
hot water
temperature
before use
15
°C
priority
in use
x10l
on
off
check
hot water
temperature
before use
42
°C
priority
in use
42
°C
priority
in use
water
volume
Page 19
TEMPERATURE CONTROL – STANDARD
19
5. Turn off the alarm
Press the water volume button to turn off the alarm.
The water volume operating light goes out and 0 x10l is displayed momentarily on the controller.
The temperature setting of the controller with priority is then displayed.
6. Close the hot tap
If it is a Bathroom controller which is in use and has priority, then it is advised to leave the controller on.
Refer to the warning in the notes on page 16.
If it is the Kitchen controller which is in use and has priority, then it is advised to turn the controller off.
Refer to Important note for Bathroom controllers on
page 16.
Notes on the water volume function:
The water volume can only be set by the Kitchen controller.
The Kitchen controller does not require priority nor to be on in order to set the water volume function.
The water volume function can be set whilst a hot tap is open.
The water volume alarm will only sound from the Kitchen controller.
The water volume alarm will still sound if the Kitchen controller has been silenced (refer to “Silencing A
Controller” on page 11).
The factory preset water volume is 180 litres.
If a hot tap is not opened for one hour after the new water volume has been set, then the setting will be
automatically cancelled. The water volume resets to the previously set water volume (or the factory preset water volume if no water volume has previously been set).
To display the remaining water volume while water is being drawn, press the water volume button. After
a few seconds, the display returns to the temperature setting.
To turn off the water volume function before the alarm sounds, press the water volume button twice.
The water volume is measured as the water flows through the water heater. Therefore if more than one
hot tap is open, the alarm will respond to the total water volume drawn from all taps and the expected water volume from the first tap will be decreased.
If the hot tap is closed before the set water volume flows through the water heater and the water volume
button is left on, then the alarm will sound when the remaining water volume is consumed during a later operation. To prevent the alarm from sounding, press the water volume button twice to turn it off.
water
volume
42
°C
on
off
check
hot water
temperature
before use
priority
in use
x10l
42
°C
priority
in use
Page 20
20
TEMPERATURE CONTROL – DELUXE
DELUXE CONTROLLER FUNCTIONS
If one or more Deluxe controllers are installed, at least one must be on or the bath fill function activated for the water heater to operate. If all Deluxe controllers and the bath fill function are off, the water heater will only deliver cold water.
ON / OFF button – The ON / OFF button must be pressed once to turn on the Deluxe controller. A Deluxe
controller cannot be turned on if water is flowing from a hot tap.
To turn off a Deluxe controller, press the ON / OFF button once. A Deluxe controller can be turned off whilst water is flowing.
ON / OFF operating light – The light in the ON / OFF button will glow when the Deluxe controller is turned on.
The light will go out when the Deluxe controller is turned off.
ACTIVE light – The ACTIVE light will glow on a Deluxe controller when the controller is ‘active’, i.e. it
has priority. The Bathroom Deluxe controller(s), if they are turned on, are ‘active’ and have priority over the Kitchen Deluxe controller.
ACTIVE or priority means that Deluxe controller has control of the water heater temperature setting. The water temperature setting can only be adjusted by a Deluxe controller that has priority and is displaying the ACTIVE light.
operating light – The operating light will glow on all Deluxe controllers, whether they are on or off, when
hot water is flowing, regardless of which Deluxe controller has priority.
temperature display panel – The current temperature setting is displayed in °C on all Deluxe controllers
(whether hot water is flowing or not), when any Deluxe controller is on. If all Deluxe controllers are off, the display remains blank.
i (up button) – The up button increases the water temperature setting (refer to “Temperature
Adjustment – Deluxe Controllers” on page 25).
j (down button) – The down button decreases the water temperature setting (refer to “Temperature
Adjustment – Deluxe Controllers” on page 25).
assistance call button – Pressing this button sounds an alert message on all Deluxe controllers, indicating
that assistance is required in the room from which the assistance call button was activated.
speaker – The audio of the voice prompts and chimes is emitted from the speaker. BATH FILL button – The BATH FILL button must be pressed once to turn on the Bath Fill mode.
When the Bath Fill mode is turned on, the last selected bath fill water volume in litres will be displayed in the bath fill water volume display panel and the last selected bath fill temperature in °C will be displayed in the ‘temperature’ display panel.
The bath fill water volume and temperature can be adjusted by using the BATH FILL VOLUME and BATH FILL TEMPERATURE buttons located behind the hinged panel on the lower half of the Deluxe controller (refer to “Bath-Fill Mode” on page 30).
To turn off the Bath Fill mode, press the BATH FILL button.
BATH FILL operating light – The light in the BATH FILL button will glow when the BATH FILL button is
pressed and the Bath Fill mode is turned on.
The light in the button will flash when the selected bath fill function is complete but before the Bath Fill mode has been turned off.
The light will go out when the BATH FILL button is pressed and the Bath Fill mode is turned off.
Page 21
TEMPERATURE CONTROL – DELUXE
21
bath fill water volume display panel – The selected bath fill water volume is displayed in litres on all Deluxe
controllers.
The selected bath fill water volume is displayed whenever the Bath Fill mode is on (refer to “Bath Fill Mode” on page 30) or when the bath fill water volume is being adjusted and the Bath Fill mode is off.
If the bath fill water volume is being adjusted and the Bath Fill mode is off, then the bath fill water volume display panel goes blank three (3) seconds after a BATH FILL VOLUME button is last pressed.
At other times, if the Bath Fill mode is off, the bath fill water volume display panel remains blank.
bath fill indicator light – this light in the display panel will glow when the bath fill water volume is displayed. BATH FILL TEMPERATURE i (up button) – The up button increases the bath fill water temperature
setting (refer to “Temperature Adjustment – Deluxe Controllers” on page 25 and to
“Bath Fill Mode” on page 25).
BATH FILL TEMPERATURE j (down button) – The down button decreases the bath fill water temperature
setting (refer to “Temperature Adjustment – Deluxe Controllers” on page 25 and to
“Bath Fill Mode” on page 25).
BATH FILL VOLUME i (up button)– The up button increases the bath fill water volume setting in
increments of 10 litres up to 500 litres. A further setting of 990 litres can be selected.
BATH FILL VOLUME j (down button) – The down button decreases the bath fill water volume setting from
990 litres to 500 litres and in increments of 10 litres from 500 litres down to 10 litres.
DELUXE CONTROLLER
Rheem
BATH (l)
42
°C
230
A
CTIVE
BATH FILL ON/OFF
K
BATH FILL
VOLUME
BATH FILL
TEMPERATURE
ACTIVE Light on
2.
Adjust
Temperature
3.
Open hot
tap
4.Hot Water
Press
1.
ON/OFF
Bath Fill completed (automatic)
Bath Fill Button
(Red light flashes)
6. Close hot tap
5.
Press Bath Fill Button
(Red light on)
3.
4. Open hot tap
BATH FILL
Press Bath Fill Button
(red light off)
7.
BATH FILL
Bath Fill
Bath
Water
Volume
Bath Fill Temp
Set Bath Fill Water Volume
and Temperature
1. 2.
BATH FILL
VOLUME
j down button
BATH FILL
VOLUME
i up button
BATH FILL
button
assistance call
button
BATH FILL
operating light
Deluxe controller type
K = Kitchen B1 = Bathroom1 B2 = Bathroom2
brief Deluxe controller operating instructions
bath-fill mode and
hot water mode
BATH FILL
TEMPERATURE
j down button
BATH FILL
TEMPERATURE
i up button
ON / OFF
button
ON / OFF
operating light
i up
button
j down
button
operating
light
ACTIVE
light
BATH FILL
indicator light
temperature display panel
speaker
bath fill water volume
display panel
Page 22
TEMPERATURE CONTROL – DELUXE
22
VOICE PROMPT AND OPERATING TONE
The Deluxe controllers have a series of voice prompts and operating tones which sound during certain operations.
The voice prompts and operating tones sound from all Deluxe controllers, regardless of which Deluxe controller is being operated at the time.
Voice Prompt
The voice prompts are:
When either the up (i) button or BATH FILL TEMPERATURE i (up button) is pressed
“hot water temperature has been increased”
When either the down (j) button or BATH FILL TEMPERATURE j (down button) is pressed
“hot water temperature has been decreased”
When the BATH FILL VOLUME i (up button) is pressed
“Caution, bath fill water volume has been increased, bath may overflow”
When the BATH FILL VOLUME j(down button) is pressed
“bath fill water volume has been decreased”
When the BATH FILL button is pressed to turn on the bath Fill mode
“please set bath water volume and bath temperature, then open the hot water tap”
When the set bath fill water volume has been delivered from the water heater during Bath Fill mode
“the bath is ready, please turn off the hot water tap and press the BATH FILL button to finish”
When the BATH FILL button is pressed to halt the bath fill function before it is complete
“bath filling has been stopped, please turn off the hot water tap and press the BATH FILL button to finish”
When the BATH FILL button is pressed to turn the Bath Fill mode off and the hot tap has not been
turned off
“please ensure the bath hot water tap is turned off”
When the Deluxe controllers have been turned off during the bath fill function
“bath filling has been stopped”
When the assistance call button is pressed
“assistance required, assistance required”
Operating Tone
The operating chime will sound when the temperature adjustment up (i) button or down (j) button is pressed and the voice prompt is not speaking.
The operating beep will sound for each change in temperature increment when a BATH FILL TEMPERATURE adjustment button is pressed or scrolled, whether the voice prompt is speaking or not.
The operating beep will sound for each change in volume increment when a BATH FILL VOLUME adjustment button is pressed or scrolled and the voice prompt is not speaking.
Page 23
TEMPERATURE CONTROL – DELUXE
23
Adjusting the Volume of the Voice Prompt and Operating Tone
The volume of the voice prompt and the operating tone can be adjusted to a level comfortable for you. The volume of the voice prompt and the operating tone can be adjusted independently of each other. The volume levels on a Deluxe controller are adjusted independently of another Deluxe controller.
The voice prompt and / or operating tone can also be turned off on an individual or all Deluxe controllers so they do not sound at all.
The factory default volume setting of both the voice prompt and operating tone is medium [med]. If there is an interruption to the water heater power supply, the volume of both the voice prompt and operating tone returns to the default setting.
When adjusting the volume levels, the operating tone volume level is indicated by a chime, followed by the voice prompt volume level which is indicated by two beeps. If during the volume setting procedure only the chime is audible, this indicates the voice prompt is off. If during the volume setting procedure only the two beeps is audible, this indicates the operating tone is off.
To adjust or turn off the volume for the voice prompt and operating tone:
Turn off all Deluxe controllers.
Press and hold the up (i) button, then within four (4) seconds press the ON / OFF button.
Each press of the ON / OFF button will change the voice prompt and operating tone in the following sequence:
operating tone [MAX], voice prompt [OFF]
operating tone [MIN], voice prompt [MIN]
operating tone [MIN], voice prompt [OFF]
operating tone [OFF], voice prompt [OFF]
operating tone [MAX], voice prompt [MAX]
operating tone [MED], voice prompt [OFF]
operating tone [MED], voice prompt [MED]
This order then repeats.
Note: If the ON / OFF button is not pressed within four (4) seconds of the up (i) button being pressed,
“CL” will start flashing on the temperature display panel. If this occurs, release the up (i) button and recommence the procedure.
ASSISTANCE CALL FUNCTION
A Deluxe controller has an assistance call button. Should assistance be required, such as when in the bathroom, a voice prompt will sound on all Deluxe controllers to notify others that assistance is required.
The Deluxe controller does not have to be on for the assistance call function to be activated and the function can be activated during any operation.
To Call for Assistance
To operate the assistance call function:
1. Press the green assistance call button.
The voice prompt will sound on all Deluxe controllers,
“assistance required, assistance required”
The red light in the assistance call button will glow on all Deluxe controllers for the duration of the voice prompt.
“assistance required,
assistance required”
BATH (l)
88
°C
A
CTIVE
BATHFILL ON/OFF
BATH (l)
88
°C
A
CTIVE
BATHFILL ON/OFF
Page 24
TEMPERATURE CONTROL – DELUXE
24
TEMPERATURE SETTINGS – DELUXE CONTROLLERS
The temperature settings of each type of Deluxe controller are:
Bathroom1 & 2 Deluxe 37°C to 48°C* (in 1°C increments), 50°C
Kitchen Deluxe 37°C to 48°C* (in 1°C increments), 50°C*, 55°C
(Limited to 48ºC when set in bathfill mode.)
.
Temperature settings
37 38 39 40 41 42 43 44 45 46 47 48 50 55
warm average hot shower hot very hot
The installation of a Bathroom Deluxe controller(s) only (i.e. no Kitchen Deluxe controller) limits the temperature setting of the water heater to a maximum of:
874 series 50ºC
regardless of the preset outlet temperature setting of the water heater.
The installation of a Kitchen Deluxe controller will allow a maximum temperature setting of:
874 series 55ºC
regardless of the preset outlet temperature setting of the water heater.
If Deluxe or standard controllers are not installed, the water heater defaults to the preset outlet temperature setting. This may be up to:
874 series 55ºC
Refer to “How Hot Should The Water Be?” on page 5.
On a building fitted with a temperature limiting device such as a tempering valve and where an 874 series water heater is installed without a separate untempered hot water line to the kitchen, laundry or other non­ablution area, although the Kitchen Deluxe controller will be able to display temperatures above 55°C and the water leaving the water heater will be at the set temperature, the maximum water temperature which can be delivered to the hot water outlets in these locations is determined by the temperature setting of the temperature limiting device. This is usually 55°C.
To enable the delivery of water temperatures above 55°C to the kitchen, laundry or other non-ablution area, separate untempered pipe work must be installed from the water heater to the hot water outlets in these locations and water heater temperature increased to 75ºC.
Page 25
TEMPERATURE CONTROL – DELUXE
25
TEMPERATURE ADJUSTMENT – DELUXE CONTROLLERS
A controller must be on with the ACTIVE indicator displayed to be able to adjust the temperature setting.
The temperature adjustment is made by pressing the up (i) button or down (j) button.
The minimum temperature setting for each type of controller is 37°C.
The maximum temperature setting for the controllers are:
Kitchen Bathroom
874 series
55°C 50°C
Each press of the up (i) button will increase the temperature setting by one increment.
Pressing and holding the up (i) button will scroll the temperature setting up to a maximum 43°C if there
is hot water flowing or 45°C if there is no hot water flowing.
From the 45°C setting, the up (i) button must be pressed once for each increase in temperature
increment.
The temperature setting cannot be increased above 43°C whilst hot water is flowing.
Each press of the down (j) button will decrease the temperature setting by one temperature increment.
Pressing and holding the down (j) button will scroll down the temperature setting.
The temperature setting can be decreased from any temperature setting whether the hot water is flowing
or not.
Note: A Deluxe controller sounds a double beep at the 42°C temperature setting, if the voice prompt is not
speaking, when either the up (i) button or down (j) button has been pressed. The double beep does not
sound at the 42°C temperature setting when the BATH FILL TEMPERATURE i (up button) or BATH FILL TEMPERATURE j(down button) is pressed.
Page 26
TEMPERATURE CONTROL – DELUXE
26
KITCHEN CONTROLLER – DELUXE
The Kitchen Deluxe controller allows the user to select the temperature setting for the hot water to be used in the kitchen and laundry. It has a minimum temperature setting of 37°C and a maximum temperature setting of:
874 series 55ºC
The Kitchen Deluxe controller does not have priority (ACTIVE light is off) if a Bathroom Deluxe controller is on.
Notes on the Kitchen Deluxe controller:
The Deluxe controller cannot be turned on whilst a hot tap is open.
The Kitchen Deluxe controller must be on and have priority (ACTIVE light glows) in order to adjust the
temperature setting on the Kitchen Deluxe controller.
The Bathroom Deluxe controller(s) can be turned off from the Kitchen Deluxe controller.
Press and hold the ON / OFF button on the Kitchen Deluxe controller for three seconds. This turns off all the Deluxe controllers, including the bath fill function if it is on, the displays go blank and the lights go out. If hot water is flowing from a hot tap, it will go cold.
Rheem
BATH (l)
40
°C
120
ACTIVE
ON/OFFBATHFILL
Kitchen Deluxe Controller
Page 27
TEMPERATURE CONTROL – DELUXE
27
To operate the Kitchen Deluxe controller:
1. Turn off the Bathroom Deluxe controller(s)
If a temperature setting is displayed and the ACTIVE
light is not glowing, it is necessary to turn off the Bathroom Deluxe controller(s) to gain priority.
Refer to the notes on the Kitchen Deluxe controller on
page 26.
2. Turn on the Kitchen Deluxe controller
Press the ON / OFF button.
The light in the ON / OFF button and the ACTIVE light will both glow.
The previous Kitchen Deluxe controller temperature setting will be displayed on the temperature display panel.
3. Select the temperature setting
Press the up (i) button or down (j) button.
When the down (j) button is pressed, the voice prompt will sound;
“hot water temperature has been increased”
When the down (j) button is pressed, the voice prompt will sound;
“hot water temperature has been decreased”
Refer to “Temperature Adjustment – Deluxe
Controllers” on page 25.
The selected temperature setting will be displayed on all Deluxe controllers.
4. Open the hot tap.
The operating light will glow on all Deluxe controllers.
5. Close the hot tap.
The operating light will go out on all Deluxe controllers, if no other hot tap is open.
6. Turn off the Kitchen Deluxe controller
Press the ON / OFF button.
The ACTIVE light and the ON / OFF light will go out and the temperature display panel will go blank.
Important: Turn off the Kitchen Deluxe controller after hot
water usage is finished in the kitchen and / or laundry. Refer
to Important note for Bathroom Deluxe controllers on
page 28.
BATH(l)
55
°C
8888
ACTIVE
BATHFILL ON/OFF
ON/OFF
BATH(l)
50
°C
8888
ACTIVE
BATHFILL
ON/OFF
BATH(l)
55
°C
8888
ACTIVE
BATHFILL
“hot water temperature
has been increased”,
or
“hot water temperature
has been decreased
ON/OFF
BATH(l)
55
°C
8888
ACTIVE
BATHFILL
ON/OFF
BATH(l)
55
°C
8888
ACTIVE
BATHFILL
BATH(l)
55
°C
8888
ACTIVE
BATHFILL ON/OFF
Page 28
TEMPERATURE CONTROL – DELUXE
28
BATHROOM CONTROLLERS – DELUXE
The Bathroom Deluxe controller(s) allows the user to select the temperature setting for the hot water to be used in the bathroom. They have a minimum temperature setting of 37°C and a maximum temperature setting of:
874 series 50ºC
The Bathroom Deluxe controllers operate in tandem. Whenever an operation is selected on one Bathroom Deluxe controller, it is also set on the other Bathroom Deluxe controller. The Bathroom Deluxe controllers automatically have priority (ACTIVE light glows) if they are on.
Important: It is important to turn on the Bathroom Deluxe controller before opening a hot tap in the bathroom
(priority is gained automatically and the ACTIVE light glows). If the Bathroom Deluxe controller is not on and the Kitchen Deluxe controller is on (will have priority and ACTIVE light glows), then it is possible to receive water at a temperature higher than expected from a hot tap in the bathroom. This temperature could be up to:
874 series 55ºC if a temperature limiting device is installed in the hot pipe to the
bathroom or up to 55°C if a temperature limiting device is not installed.
Notes on the Bathroom Deluxe controllers:
The Deluxe controller cannot be turned on whilst a hot tap is open.
When a Bathroom Deluxe controller is turned on, it gains priority (ACTIVE light glows) from the Kitchen
Deluxe controller.
The Bathroom Deluxe controller must be on in order to adjust the temperature setting on the Bathroom
Deluxe controller.
The Kitchen Deluxe controller can be turned off from a Bathroom Deluxe controller.
Press and hold the ON / OFF button on the Bathroom Deluxe controller for three seconds. This turns off all the Deluxe controllers, including the bath fill function if it is on, the displays go blank and the lights go out. If hot water is flowing from a hot tap, it will go cold.
Warning: It is advised to leave the Bathroom Deluxe controller on after hot water usage is finished in
the bathroom. Turning off a Bathroom Deluxe controller in one bathroom will also turn off the Bathroom Deluxe controller in the other bathroom. The Kitchen Deluxe controller will gain priority
(ACTIVE light glows) if it is on and the temperature setting can be up to:
874 series 55°C
If a hot tap is open in another bathroom, the water will be delivered at up to 55°C for an 874 series model if a temperature limiting device is installed in the hot pipe to the bathroom, or up to 55°C if a temperature limiting device is not installed.
Rheem
BATH(l)
40
°C
120
ACTIVE
ON/OFFBATHFILL
B1
BATHFILL
VOLUME
BATHFILL
TEMPERATURE
ACTIVE
Lighton
2.
Adjust
Temperature
3.
Openhot
tap
4.HotWater
Press
1.
ON/OFF
Bath
Water
Volume
Bath Fill Temp
BathFill
SetBathFillWaterVolume
andTemperature
1. 2.
BathFill
completed
(automatic)
BathFillButton
(Redlightflashes)
6.Closehottap
5.
PressBath
FillButton
(Redlighton)
3.
4. Openhottap
BATHFILL
PressBath FillButton
(Redlightoff)
7.
BATHFILL
Bathroom Deluxe
Controller
front cover
closed
front cover
open
Page 29
TEMPERATURE CONTROL – DELUXE
29
To operate a Bathroom Deluxe controller:
1. TurnofftheKitchenDeluxecontroller
Ifatemperaturesetting isdisplayedandtheACTIVE
andON/OFFoperatinglightsarenot glowing,itis advisedtoturnofftheKitchenDeluxecontroller.
Refertothe notes ontheBathroomDeluxe
controllersonpage28.
2. TurnontheBathroomDeluxecontroller
PresstheON/OFFbutton.
Thelight in theON/OFFbuttonandtheACTIVE lightwillbothglow.
TheprevioustemperaturesettingoftheBathroom Deluxecontrollerwillbedisplayedonthe temperaturedisplaypanel.
3. Selectthetemperaturesetting
Presstheup(i)buttonordown(j)button.
Whentheup(i)button is pressed,thevoice promptwillsound;
“hotwatertemperaturehasbeenincreased”
Whenthedown(j)button is pressed,thevoice promptwillsound;
“hotwatertemperaturehasbeendecreased”
Referto“TemperatureAdjustment –Deluxe
Controllers”onpage25.
Theselectedtemperaturesettingwillbedisplayed onallDeluxecontrollers.
4. Openthehottap
TheoperatinglightwillglowonallDeluxecontrollers.
5. Closethehottap
TheoperatinglightwillgooutonallDeluxecontrollers, ifnootherhottapisopen.
It is advisednottoturnofftheBathroomDeluxe controller(s).
Refertothewarninginthenotesonpage28.
BATH(l)
55
°C
8888
ACTIVE
BATHFILL ON/OFF
ON/OFF
BATH(l)
40
°C
8888
ACTIVE
BATHFILL
ON/OFF
BATH(l)
42
°C
8888
ACTIVE
BATHFILL
“hot water temperature
has been increased”,
or
“hot water temperature
has been decreased
ON/OFF
BATH(l)
42
°C
8888
ACTIVE
BATHFILL
ON/OFF
BATH(l)
42
°C
8888
ACTIVE
BATHFILL
Page 30
TEMPERATURE CONTROL – DELUXE
30
BATH FILL MODE
The Bath Fill mode is designed to allow the water heater to deliver a selected volume of water at a selected temperature. The Bath Fill mode commences when the BATH FILL button is on and a hot tap is opened. When the set volume has been delivered, the water flow from the water heater ceases and heating stops. It is also useful for controlling the water volume used by a shower or other application.
Note: The bath level should be monitored periodically while this function is in use to avoid the possibility of
the bath overflowing. The Bath Fill mode should be used with caution until you are familiar with its operation.
Warning: Baths should not be left unattended whenever young children are present. After using the
bath fill function, check the water temperature before entering a bath, to ensure it is suitable and will not cause scald injury.
The Bath Fill mode can be set and turned off at any of the Deluxe controllers. Refer to the notes on page 36.
Bath Fill Mode – Brief Guide
This guide provides a brief instruction on the operating sequence of the bath fill function. It is recommended to read the explanatory notes and become familiar with each step in the bath fill function. Refer to “Bath Fill
Mode – Explanatory Notes” on page 32.
To operate the Bath Fill Mode:
1. Turn off all Deluxe controllers
It is advised to turn off all Deluxe controller(s) before
activating the Bath Fill mode.
Refer to the notes on the Bathroom Deluxe controllers on page 28.
2. Pull down the front panel on the Deluxe controller.
The BATH FILL VOLUME and BATH FILL TEMPERATURE up (i) and down (j) buttons will be exposed.
3. Set the Bath Fill temperature
Press the BATH FILL TEMPERATURE i (up button) or
the BATH FILL TEMPERATURE j (down button) to
select the desired bath fill temperature.
Refer to “Temperature Adjustment – Deluxe Controllers”
on page 25.
The selected temperature setting will be displayed on all Deluxe controllers.
4. Set the bath fill water volume
Press the BATH FILL VOLUME i (up button) or the
BATH FILL VOLUME j (down button) to select the
desired bath fill water volume. Each press will change the water volume setting by 10 litres.
Pressing the BATH FILL VOLUME i (up button) or BATH FILL VOLUME j (down button) continuously
will scroll the water volume setting.
A maximum volume of 990 litres and a minimum volume of 10 litres can be set. The volume changes in 10 litre increments.
The selected bath fill water volume will be displayed and the bath fill indicator light will glow on all Deluxe controllers.
BATH (l)
55
°C
8888
ACTIVE
BATHFILL ON/OFF
B1
BATHFILL
VOLUME
BATHFILL
TEMPERATURE
“hot water temperature has
been increased”
or
“hot water temperature has
been decreased”
BATH (l)
40
°C
120
ACTIVE
ON/OFFBATHFILL
“caution, bath fill water volume has
been increased, bath may overflow”
or
“bath fill water volume has been
decreased
BATH (l)
40
°C
120
ACTIVE
ON/OFFBATHFILL
Page 31
TEMPERATURE CONTROL – DELUXE
31
5. Close the front panel on the Deluxe controller.
6. Turn on the Bath Fill mode
Press the BATH FILL button.
On all Deluxe controllers:
The BATH FILL operating light will glow.
The bath fill temperature setting will appear on
the temperature display panel.
The bath fill water volume will appear on the
bath fill water volume display panel.
The bath fill indicator light will glow.
7. Open the hot tap.
The operating light will glow on all Deluxe controllers.
Measurement of the water flow at the water heater will commence when the hot tap is opened.
When the set volume of water has passed through the water heater:
Water flow from the hot tap will cease.
The operating light will go out.
The bath fill water volume display panel will show
0 litres.
The temperature display will go blank.
The BATH FILL operating light will commence to flash
The voice prompt will sound;
“the bath is ready, please turn off the hot water tap and press the BATH FILL button to finish”
8. Close the hot tap.
9. Turn off the Bath Fill mode
Press the BATH FILL button.
The BATH FILL operating light and bath fill indicator light will go out.
The BATH FILL operating light and bath fill indicator light will go out.
The bath fill water volume display will go blank.
Note: If the hot tap has not been turned off, the
voice prompt will sound;
“please ensure the bath hot water tap is turned off”
Rheem
“please set bath water volume
and bath temperature, then
open the hot water tap”
BATHFILL
BATH(l)
40
°C
120
ACTIVE
ON/OFF
BATHFILL
BATH(l)
40
°C
120
ACTIVE
ON/OFF
“the bath is ready,
p
lease turn off the hot water tap
and press the
BATH FILL button to finish”
BATHFILL
BATH(l)
40
°C
0
ACTIVE
ON/OFF
BATHFILL
BATH(l)
40
°C
0
ACTIVE
ON/OFF
“please ensure the bath hot
water tap is turned off”
BATH(l)
40
°C
0
A
CTIVE
ON/OFFBATHFILL
Page 32
TEMPERATURE CONTROL – DELUXE
32
Bath Fill Mode – Explanatory Notes
To operate the Bath Fill mode:
1. Turn off all Deluxe controllers
It is advised to turn off all Deluxe controller(s) before
activating the Bath Fill mode.
Refer to the notes on the Bathroom Deluxe
controllers on page 28.
The Deluxe controllers do not need to be on to set the bath fill temperature and bath fill water volume and to turn on the Bath Fill mode.
2. Pull down the front panel on the Deluxe controller.
The BATH FILL VOLUME and BATH FILL TEMPERATURE up (i) and down (j) buttons will be exposed.
3. Set the bath fill temperature
Press the BATH FILL TEMPERATURE
i (up button) or the BATH FILL TEMPERATURE j (down button).
The first press of either the BATH FILL
TEMPERATURE (up button) or the BATH FILL TEMPERATURE (down button) will bring up the last
selected bath fill temperature setting.
While the bath fill temperature is displayed, each subsequent press of the BATH FILL
TEMPERATURE (up button) or BATH FILL TEMPERATURE (down button) will change the
temperature setting.
Refer to “Temperature Adjustment – Deluxe
Controllers” on page 25.
When the BATH FILL TEMPERATURE
i (up button) is pressed and the temperature
setting is increased, the voice prompt will sound;
“hot water temperature has been increased”
When the BATH FILL TEMPERATURE (down button) is pressed and the temperature setting is
decreased, the voice prompt will sound;
“hot water temperature has been decreased”
The selected temperature setting will be displayed in the temperature display panel and will be displayed on all Deluxe controllers.
The temperature display panel will go blank 3 seconds after the last press of either of the bath fill temperature adjustment buttons.
The bath fill temperature setting will be remembered when the BATH FILL button is pressed “on”.
BATH(l)
40
°C
120
ACTIVE
ON/OFFBATHFILL
B1
BATHFILL VOLUME
BATHFILL
TEMPERATURE
ACTIVE
Lighton
2.
Adjust
Temperature
3.
Openhot
tap
4.HotWater
Press
1.
ON/OF
F
Bath
Water
Volume
Bath Fill Temp
BathFill
SetBathFillWaterVolume
andTemperature
1. 2.
BathFill
completed
(automatic)
BathFillButton
(Redlightflashes)
6.Closehottap
5.
PressBath FillButton
(Redlighton)
3.
4.Openhottap
BATHFILL
PressBath FillButton
(R
edlightoff)
7.
BATHFILL
BATH (l)
40
°C
120
ACTIVE
ON/OFFBATHFILL
B1
BATHFILL
VOLUME
BATHFILL
TEMPERATURE
ACTIVE Lighton
2.
Adjust
Temperature
3.
Openhot
tap
4.HotWater
Press
1.
ON/OFF
Bath
Water
Volume
Bath Fill Temp
BathFill
SetBathFillWaterVolume
andTemperature
1. 2.
BathFill completed (automatic)
BathFillButton
(Redlightflashes)
6.Closehottap
5.
PressBath FillButton
(Redlighton)
3.
4.Openhottap
BATHFILL
PressBath FillButton
(R
edlightoff)
7.
BATHFILL
“hot water
temperature
has been
increased”
or
“hot water
temperature
has been
decreased”
Page 33
TEMPERATURE CONTROL – DELUXE
33
4. Set the bath fill water volume
Press the BATH FILL VOLUME (up button) or the
BATH FILL VOLUME (down button).
The first press of either the BATH FILL VOLUME
i (up button) or the BATH FILL VOLUME j(down button) will display the last selected bath fill
water volume setting in the bath fill water volume display panel and the bath fill indicator light will glow.
While the bath fill water volume is displayed, each subsequent press of the BATH FILL VOLUME
i (up button) or BATH FILL VOLUME j (down button) will change the water volume
setting by 10 litres.
When the BATH FILL VOLUME i (up button) is
pressed and the water volume setting is increased, the voice prompt will sound;
“caution, bath fill water volume has been increased, bath may overflow”
When the BATH FILL VOLUME j (down button) is pressed and the water volume setting is
decreased, the voice prompt will sound;
“bath fill water volume has been decreased”
Pressing the BATH FILL VOLUME i (up button) or BATH FILL VOLUME j (down button)
continuously will scroll the water volume setting.
A maximum volume of 990 litres and a minimum volume of 10 litres can be set. The maximum volume of 990 litres is achieved in 10 litre increments up to 500 litres, then 990 litres is the next setting.
The selected bath fill water volume will be displayed and the bath fill indicator light will glow on all Deluxe controllers.
The bath fill water volume display panel will go blank and the bath fill indicator light will go out 3 seconds after the last press of either of the volume adjustment buttons.
The set volume will be remembered when the BATH FILL button is next pressed “on”.
5. Close the front panel on the Deluxe controller.
6. Turn on the Bath Fill mode
Press the BATH FILL button.
On all Deluxe controllers:
The BATH FILL operating light will glow.
The bath fill temperature setting will appear on
the temperature display panel.
The bath fill water volume will appear on the
bath fill water volume display panel.
The bath fill indicator light will glow.
The voice prompt will sound;
“please set bath water volume and bath temperature, then open the hot water tap”
BATH (l)
40
°C
120
A
CTIVE
ON/OFFBATHFILL
B1
BATHFILL
VOLUME
BATHFILL
TEMPERATURE
ACTIVE Lighton
2.
Adjust
Temperature
3.
Openhot
tap
4.HotWater
Press
1.
ON/OFF
Bath
Water
Volume
Bath Fill Temp
BathFill
SetBathFillWaterVolume
andTemperature
1. 2.
BathFill
completed
(automatic)
BathFillButton
(Redlightflashes)
6.Closehottap
5.
PressBath FillButton
(Redlighton)
3.
4.Openhottap
BATHFILL
PressBath FillButton
(R
edlightoff)
7.
BATHFILL
“caution,
bath fill water
volume has been
increased,
bath may overflow
or
“bath fill water
volume has been
decreased”
Rheem
BATH(l)
40
°C
120
A
CTIVE
ON/OFFBATHFILL
BATHFILL
BATH(l)
40
°C
120
A
CTIVE
ON/OFF
Rheem
“please set
bath water volume
and
bath temperature,
then open the hot water tap”
Page 34
TEMPERATURE CONTROL – DELUXE
34
7. Open the hot tap.
The operating light will glow on all Deluxe controllers.
Measurement of the water flow at the water heater will commence when the hot tap is opened.
Notes:
If a second hot tap is opened when the Bath Fill mode
is turned on, the set bath fill water volume expected from the first hot tap will be reduced by the volume which flows through the second hot tap.
The bath fill temperature setting and bath fill water
volume setting can also be adjusted whilst a hot tap is open and the Bath Fill mode is operating.
When the set volume of water has passed through the water heater:
Water flow from the hot tap will cease.
The operating light will go out.
The bath fill water volume display panel will show
0 litres.
The temperature display will go blank.
The BATH FILL operating light will commence to flash
The voice prompt will sound;
“the bath is ready, please turn off the hot water tap and press the BATH FILL button to finish”
8. Close the hot tap.
9. Turn off the Bath Fill mode
Press the BATH FILL button.
The BATH FILL operating light and bath fill indicator light will go out.
The bath fill water volume display will go blank.
Note: If the hot tap has not been turned off, the
voice prompt will sound;
“please ensure the bath hot water tap is turned off”
BATHFILL
BATH(l)
40
°C
120
ACTIVE
ON/OFF
“the bath is ready,
p
lease turn off the hot water tap
and press the
BATH FILL button to finish”
BATHFILL
BATH(l)
40
°C
0
ACTIVE
ON/OFF
BATHFILL
BATH(l)
40
°C
0
ACTIVE
ON/OFF
“please ensure the bath hot
water tap is turned off”
BATH(l)
40
°C
0
A
CTIVE
ON/OFFBATHFILL
Page 35
TEMPERATURE CONTROL – DELUXE
35
Turning Off Bath Fill Mode During Its Operation
The bath fill operation can be interrupted by pressing the BATH FILL button before completion of the bath fill operation.
If it is necessary to turn off the Bath Fill mode before the operation is complete, during Step 7:
Press the BATH FILL button
At this first press of the BATH FILL button
Water flow from the hot tap will cease
The operating light will go out
The bath fill water volume display panel will show
0 litres.
The temperature display will go blank
The bath fill operating light will flash
The voice prompt will sound
“bath filling has been stopped, please turn off the hot water tap and press the BATH FILL button to finish”
Close the hot tap
Press the BATH FILL button again
At this second press of the BATH FILL button
The bath fill operating light and bath fill indicator light
will go out
The bath fill water volume display will go blank
Note: If the hot tap has not been turned off, the voice
prompt will sound
“please ensure the bath hot water tap is turned off”
“bath filling has been stopped,
p
lease turn off the hot water tap
and press the
BATH FILL button to finish”
BATHFILL
BATH(l)
40
°C
0
A
CTIVE
ON/OFF
BATHFILL
BATH(l)
40
°C
0
ACTIVE
ON/OFF
“please ensure the bath hot
water tap is turned off”
BATH(l)
40
°C
0
A
CTIVE
ON/OFFBATHFILL
Page 36
TEMPERATURE CONTROL – DELUXE
36
Notes on the Bath Fill mode:
The Bath Fill mode can be set and turned on at any of the Deluxe controllers.
The Deluxe controllers do not require to have priority (ACTIVE light glowing) or be on in order to set the
bath fill water volume or bath fill temperature or to turn the BATH FILL button on.
The BATH FILL button cannot be turned on whilst a hot tap is open.
The bath fill water volume and the bath fill temperature settings can be adjusted whilst a hot tap is open.
If a hot tap is not opened for six hours after the new bath fill water volume and bath fill temperature has
been set, whilst the BATH FILL button is on, the settings will be automatically cancelled and will reset to the previous settings or to the factory default settings if no previous settings have been set.
The factory default bath fill water volume setting is 180 litres.
The factory default bath fill temperature setting is 40°C.
The Bath Fill mode will automatically have priority when the BATH FILL button is pressed and the
Bath Fill mode is turned on. If the ACTIVE light is glowing on a Deluxe controller, it will go out. The ACTIVE light on a Deluxe controller will not glow whenever the BATH Fill operating light is on.
Whilst water is flowing from a hot tap during the bath fill operation (BATH FILL operating light is on), a
Deluxe controller cannot be turned on or off:
if it is on, pressing the ON / OFF button will not turn it off
if it is off, pressing the ON / OFF button will not turn it on.
Whilst there is no water flowing from a hot tap and the BATH FILL operating light is on, a Deluxe
controller can be turned on (ON / OFF light glows), but it will not gain priority (ACTIVE light will not glow).
Pressing the up (i) button or down (j) button above the ON / OFF button during the bath fill operation
(BATH FILL operating light is on) will not adjust the temperature setting.
Important
Ensure all hot taps are turned off after a bath fill operation is complete and before pressing the
BATH FILL button “OFF”. Otherwise;
Water will flow from the hot tap when the BATH FILL button is pressed “OFF”.
The water will be cold if all Deluxe controllers are off, or hot if a Deluxe controller is ACTIVE.
The voice prompt will also sound;
“please ensure the bath hot water tap is turned off”.
Page 37
TEMPERATURE CONTROL – DELUXE
37
Opening a Second Hot Water Tap During Bath Fill Operation
The bath fill water volume is measured as the water flows through the water heater. If more than one hot
tap is open, the Bath Fill mode will measure the total water volume drawn from all taps and the expected water volume from the first tap will be decreased.
If the hot water supply should cease unexpectedly, check to see if the BATH FILL operating light is
flashing
If the BATH FILL operating light is flashing, this indicates the set bath fill water volume has been
delivered and the bath fill operation is complete
If further hot water is required for the application:
Turn off the hot tap
Press the bath fill button to turn off the Bath Fill mode
Recommence the Bath Fill procedure from Step 3, ensuring the water volume is adjusted to the
volume required to complete the application.
Early Completion of Bath Fill Operation
If the hot tap is closed before the set water volume flows through the water heater and the Bath Fill
button is left on, the Bath Fill mode remains active for six hours.
If during this time a hot tap is turned on, the bath fill operation continues until the remaining bath fill
water volume is consumed, then
The water flow will cease and the voice prompt will sound;
“the bath is ready, please turn off the hot water tap and press the BATH FILL button to finish”
Close the hot tap
Press the BATH FILL button
To prevent the bath fill operation completing and interrupting the hot water supply, whilst the hot tap
is off, then
press the BATH FILL button twice to turn it off
The first press of the BATH FILL button causes the bath fill operating light to flash and the voice prompt will sound
“bath filling has been stopped, please turn off the hot water tap and press the BATH FILL button to finish”
The second press of the BATH FILL button causes the bath fill operating light to go off.
Interrupting Bath Fill Operation
The bath fill operation can be interrupted by:
Pressing the BATH FILL button before completion of the bath fill operation
Refer to “Turning Off Bath Fill Mode During Its Operation” on page 35, or by
Pressing and holding the ON / OFF button on any Deluxe controller for three seconds.
This turns off all the Deluxe controllers, including the bath fill function. The displays go blank and the lights go out.
A voice prompt will sound;
“bath filling has been stopped”
Hot water flowing from a hot tap will go cold.
Turn off the hot tap.
Page 38
TEMPERATURE CONTROL – DELUXE
38
Operation of the Bath Fill mode whilst a Deluxe Controller is ACTIVE
It is recommended the Bath Fill mode be set and operated with the Deluxe controllers turned off (refer to
Step 1 on page 32).
However, if a Deluxe controller is ACTIVE during the setting and operation of the Bath Fill mode, then the following additional events occur:
During Step 3, when the bath fill temperature is being set
The temperature setting of the ACTIVE Deluxe controller will
display in the temperature display panel three seconds after the BATH FILL TEMPERATURE button is last pressed.
When the Deluxe controller temperature setting is higher than the bath fill temperature setting, the voice prompt will sound;
“hot water temperature has been increased”
When the Deluxe controller temperature setting is lower than the bath fill temperature setting, the voice prompt will sound;
“hot water temperature has been decreased”
During Step 6, when the BATH FILL button is pressed to turn the Bath Fill mode on
The Bath Fill mode has priority when operating. When the BATH FILL button is pressed, the Bath Fill mode will gain priority and over-ride the settings of all Deluxe controllers if they are on.
The ACTIVE light will go out if it is on.
The bath fill temperature setting will replace the temperature
setting in the temperature display panel.
When the bath fill temperature setting is lower than the Deluxe controller temperature setting, the voice prompt will sound;
“hot water temperature has been decreased”
When the bath fill temperature setting is higher than the Deluxe controller temperature setting, the voice prompt will sound;
“hot water temperature has been increased”
During Step 9, when the BATH FILL button is pressed to turn the
Bath Fill mode off
The ACTIVE light will glow on the Deluxe controller which
has priority.
The temperature setting of the ACTIVE Deluxe controller will
display in the temperature display panel.
Notes
If it is a Bathroom Deluxe controller which is in use and it is on, i.e. it has priority and the ACTIVE light is
glowing, then it is advised to leave the controller on.
Refer to the warning in the notes on page 28.
If it is the Kitchen Deluxe controller which is in use and it is on, i.e. it has priority and the ACTIVE light is
glowing, then it is advised to turn the controller off.
Refer to Important note for Bathroom controllers on page 28.
“hot water temperature has
been increased”
or
“hot water temperature has
been decreased
BATH (l)
46
°C
120
ACTIVE
ON/OFFBATHFILL
“hot water temperature has
been decreased”
or
“hot water temperature has
been increased
BATH (l)
40
°C
120
ACTIVE
BATHFILL ON/OFF
BATH (l)
46
°C
120
A
CTIVE
ON/OFFBATHFILL
Page 39
39
SAVE A SERVICE CALL
Check the items below before making a service call. You will be charged for attending to any condition or fault, which is not related to manufacture or failure of a part (refer to “Warranty” on page 74).
NO DISPLAY ON THE CONTROLLER
Is the controller turned on?
Press the on / off button (refer to “Temperature Control” on pages 9 to 38).
Is the water heater plugged in and the power outlet switched on?
Is power available in the house?
Try using another electrical appliance.
COLD WATER FROM THE HOT TAP
Is the controller turned on?
Press the on / off button (refer to “Temperature Control” on pages 9 to 38).
Close the hot tap, wait 10 seconds and open the hot tap again.
Is the hot tap open enough?
The burners will not light if the flow rate is less than 3.0 L / min.
Is the water heater plugged in and the power outlet switched on?
Is power available in the house?
Try using another electrical appliance.
Is the isolation valve in the gas line open?
Is there a gas supply to the rest of the house?
Try lighting another gas appliance.
Has the gas line been purged of air after installation?
Refer to your plumber.
WATER IS TOO HOT OR NOT HOT ENOUGH
Does the controller you are using have priority? (refer to “Temperature Control” on pages 9 to 38)
NO WATER FROM THE HOT TAP
No flow of water from the hot tap may indicate a restriction in or failure of the cold water supply to the water heater. Check for water flow at other taps and that the cold water isolation valve (refer to page 54) is fully open.
WATER FLOW FLUCTUATES
More than two or three taps in use at the same time may cause a decrease in the hot water flow from the taps. This can also be evident if the water heater has been installed as a gas booster water heater to a solar preheat water heater and the solar preheat water is at a low temperature.
Are there more than two or three taps open, or are appliances such as a dishwasher or washing
machine, in use at the same time?
Ensure only two or three taps or appliances are on at the one time.
Check the flow of the water from one tap, eg, the shower.
The shower should be adjusted so the hot tap is fully open.
Page 40
SAVE A SERVICE CALL
40
GAS BOOSTER OPERATING TOO FREQUENTLY
If the water heater is installed as a gas booster water heater to a solar preheat water heater, you may find that the water heater operates more frequently than expected. This will occur when the solar preheat water temperature is lower than 58°C, which may be experienced during periods of low solar energy gain or if there has been heavy hot water usage. Factors to consider are:
Hot tap not used recently
If a hot tap has not been used for a while, the water in the pipe work between the solar water heater and the gas booster water heater may have cooled down. The water heater will sense the cooler water and this will cause the burners on the water heater to ignite and boost the water temperature when a hot tap is first turned on. The burners will extinguish when solar preheated water of 58°C or higher from the solar storage tank reaches the water heater (refer also to “Fan Continues to Run after Water Heater
Operation Stops” on page 40).
Insufficient sunlight
Insufficient sunlight due to cloudy weather during summer months or low solar energy contribution in winter months may mean the gas booster operates more often.
Collectors shaded
If trees or other objects shade the solar collectors or if the glass is dirty, the effectiveness of the solar collectors will be greatly reduced. Have the trees trimmed or the solar collectors relocated if the obstruction is permanent or clean the collector glass.
Ensure the glass on your solar collectors is free of dust, salt spray or any other matter, which may reduce the effectiveness of the solar collectors. If the collector glass becomes dirty, hose down or if the solar collectors are accessible, wash the collector glass with water and a soft brush when the solar collectors are cool.
Collector area is too small
For most installations, the number of solar collectors recommended in Rheem literature has been proven to provide the required solar energy to meet the average family needs. However, in some circumstances, it may be necessary to install an additional solar collector.
Are you using more hot water than you think?
Is one outlet (especially the shower) using more hot water than you think?
Very often it is not realised the amount of hot water used, particularly when showering. Carefully review the family’s hot water usage. As you have installed an energy saving appliance, energy saving should also be practised in the home. Adjust your water usage pattern to take advantage of maximum solar gains.
Have your plumber install a flow control valve to each shower outlet, basin and sink to reduce water usage.
Water heater size
Do you have the correct size water heater for your requirements?
The sizing guide in the sales literature and on the Rheem website (www.rheem.com.au) suggests average sizes that may be needed.
FAN CONTINUES TO RUN AFTER WATER HEATER OPERATION STOPS
It is the normal operation of the water heater for the fan to continue running after heating of the water is finished. The fan may run for up to six minutes after the burners extinguish, to prepare for the next ignition.
Page 41
SAVE A SERVICE CALL
41
CLOUDS OF WHITE ‘VAPOUR’ FROM THE FLUE TERMINAL
During the heating cycle, it is not unusual to see water vapour clouds steaming from the flue terminal, particularly on cold days. This is normal operation of the water heater.
PRESSURE RELIEF VALVE DISCHARGING
A pressure relief valve is incorporated into the water heater controls. This valve protects the water heater, by allowing water to escape, in the event of excessive pressure build up in the waterways.
Normal operation
A small volume of water may discharge from the bottom of the water heater when a hot tap is suddenly closed.
Continuous dribble
A continuous dribble may indicate the water supply pressure is above the design pressure for the water heater. If so, a pressure limiting valve must be installed on the cold water supply pipe to the water heater (refer to “Mains Water Supply” on page 44).
ERROR CODE
The water heater provides a diagnostic error code in the event of an interruption to its operation. The error code is displayed on the controller(s) (if installed) and on the OK MONITOR on the front of the water heater as a numerical value. If an error code appears:
Close the hot tap, turn off the controller(s) and switch off the
electrical supply to the water heater.
Check the gas isolation valve at the gas inlet to the water heater is
fully open.
Wait 5 minutes, then switch on the electrical supply to the water
heater, turn on a controller and open a hot tap.
If the error code persists, take note of the numerical code, turn off the hot tap and turn off the controller(s). Phone your nearest Rheem Service Department or Accredited Service Centre to arrange for inspection.
HIGH GAS BILLS
Should you at any time, feel your gas account is too high, we suggest you check the following points:
Is one outlet (especially the shower) using more hot water than
you think?
Carefully review the family’s hot water usage. Inexpensive flow control valves can be easily fitted to the shower outlets to reduce water usage.
Is the gas booster water heater operating too frequently?
Refer to “Gas Booster Operating Too Frequently” on page 40.
Consider recent changes to your hot water usage pattern and
check if there has been any increase in tariffs since your previous account.
IF YOU HAVE CHECKED ALL THE FOREGOING AND STILL BELIEVE YOU NEED ASSISTANCE, CALL YOUR NEAREST RHEEM SERVICE DEPARTMENT OR ACCREDITED SERVICE CENTRE.
Page 42
42
INSTALLATION – WATER HEATER
THIS WATER HEATER IS FOR OUTDOOR INSTALLATION ONLY. THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING. Check the water heater is suitable for the gas type available. (refer to the rating label on the water heater)
The 874 series of water heater may be installed as an in-series gas booster water heater to a solar preheat water heater. For information relating to the function and operation of the solar water heater, refer to the Owner’s Guide and Installation Instructions supplied with the solar water heater.
The installation must comply with these installation instructions and with the requirements of Standards AS/NZS 3500.4 and NZS 5261 and all local codes and regulatory authority requirements.
All packaging must be removed from the water heater prior to its installation.
WATER HEATER LOCATION
The water heater should be installed close to the most frequently used outlet and its position chosen with safety and service in mind. If this water heater is part of a solar water heater system, it should also be installed close to the solar storage tank. Make sure people (particularly children) will not touch the flue terminal. The flue terminal and air inlet must be clear of obstructions and shrubbery.
Clearance must be allowed for servicing of the water heater. The water heater must be accessible without the use of a ladder or scaffold. Make sure the entire front panel can be removed for service. You must be able to read the information on the rating plate. Remember you may have to take the entire water heater out later for servicing.
This water heater must be installed vertically upright with the water, gas and power connections on the underside, pointing toward the ground. The back of the water heater can be either against a wall or supported by a frame. The water heater must be secured to the wall or frame using suitable mounting screws, two each at the top and bottom of the unit (refer to page 49 for mounting hole positions). Alternatively the water heater can be recessed into a wall (refer to
“Recess Installation” on page 43).
For a single water heater installation, refer to the diagram on page 52.
The water heater must not be installed in an area with a corrosive atmosphere where chemicals are stored or where aerosol propellants are released. Remember the air may be safe to breathe, but when it goes through a flame, chemical changes take place which may attack the water heater.
A secondary flue is not required. The water heater must not be installed indoors or in a confined space.
Page 43
INSTALLATION – WATER HEATER
43
As a guide the following requirements extracted from the New Zealand Gas Installations Standard NZS 5261, must be observed.
At least 300 mm between the top of the flue terminal and the eaves.
At least 300 mm (024) or 500 mm (027) between the
flue terminal and the edge of any opening into the building, measured horizontally along the wall.
At least 300 mm between the flue terminal and a
return wall or external corner, measured horizontally along the wall.
At least 1500 mm between the top of the flue terminal
and below any openable window measured vertically.
At least 1500 mm between the flue terminal and any
opening into a building, in the direction of the flue discharge.
At least 500 mm between the flue terminal and a
fence, wall or other obstruction, in the direction of the flue discharge.
PIPE COVER
The pipe work to the water heater can be housed within a pipe cover. A pipe cover kit (PN 299848) is available for such an installation. Refer to the installation instructions which accompany the pipe cover kit.
RECESS INSTALLATION
The water heater can be installed recessed into a wall. A recess box (PN 299849) is available for such an installation. An additional rating label is supplied with the water heater. This must be placed on either the front panel of the water heater or to another position which is visible when the water heater is installed. Refer to the installation instructions which accompany the recess box kit for information on its installation.
FROST PROTECTION
The water heater has a frost protection system. The frost protection system will protect the water heater from damage, by preventing ice forming in the waterways of the water heater, in the event of freezing conditions occurring.
The frost protection system will be rendered inoperable if electrical power is not available at the water heater. Damage to the water heater caused by freezing of the pipe work to or from the water heater is not covered under warranty. Refer to AS/NZS 3500.4 for precautions to be taken for installations in frost prone areas. The water heater is not suitable for installation in areas where the ambient temperature falls below -20ºC (including wind chill factor).
The cold water line to the water heater must be insulated with suitable thickness insulation if freezing conditions are likely to occur. The insulation must be fitted to the underside of the water heater and be weatherproof and UV resistant if exposed.
Page 44
INSTALLATION – WATER HEATER
44
MAINS WATER SUPPLY
Where the mains water supply pressure exceeds that shown in the table below, an approved pressure limiting valve that does not have non return valve characteristics (such as an RMC PSL series valve) is required and should be fitted as shown in the installation diagram (refer to page 52).
Model 874027
Relief valve setting 1750 kPa
Max. mains supply pressure 1000 kPa
Min. mains supply pressure * 140 kPa
* minimum water supply pressure required to achieve the rated flow and performance
Notes:
It is not recommended to install this water heater with a low pressure water supply.
A minimum water supply pressure of 140 kPa is required to achieve the rated flow and performance of
the water heater.
If this water heater is installed as a gas booster for a solar water heater, the maximum water supply
pressure to the solar preheat water heater, without an expansion control valve (ECV), is generally 800 kPa, however it may be less than this for some models. Refer to the Owner’s Guide and Installation Instructions supplied with the solar water heater for maximum mains supply pressure details.
This water heater is not suitable for connection to bore water or spring water unless a water treatment
device is fitted.
If sludge or foreign matter is present in the water supply, it is recommended a suitable filter be
incorporated in the cold water line to the water heater.
Refer to “Water Supplies” on page 72.
Page 45
INSTALLATION – WATER HEATER
45
HOT WATER DELIVERY
This water heater can deliver water at temperatures which can cause scalding.
It is necessary and we recommend that a temperature limiting device be fitted between an 874 series water heater and the hot water outlets in any ablution and public areas such as a bathroom, ensuite or public amenities, to reduce the risk of scalding. The installing plumber may have a legal obligation to ensure the installation of this water heater meets the delivery water temperature requirements of AS/NZS 3500.4 so that scalding water temperatures are not delivered to a bathroom, ensuite or other ablution or public area.
The temperature limiting device used with an electronic continuous flow gas water heater should have:
a specified minimum temperature differential between the hot water inlet and the tempered water outlet
of no greater than 10°C, and
a specified maximum permitted pressure variation in the supply between the hot water inlet and the cold
water inlet of no less than 15%.
Where a temperature limiting device is installed adjacent to the water heater, the cold water line to the temperature limiting device can be branched off the cold water line either before or after the isolation valve and pressure limiting valve to the water heater.
If a pressure limiting valve is installed on the cold water line to the water heater and the cold water line to a temperature limiting device branches off before this valve or from another cold water line in the premises, then a pressure limiting valve of an equal pressure setting may be required prior to the temperature limiting device.
Two Temperature Zones Using a Temperature Limiting Device
An 874 series water heater will not deliver temperatures exceeding 55°C in accordance with AS 3498. There is no statutory requirement in AS/NZS 3500.4 to fit a temperature limiting device if this water heater is installed in other than an early childhood centre, school, nursing home or a facility for young, aged, sick or disabled people. Refer to “Water Temperature Diagrams” on page 48.
Gas Booster for a Solar Water Heater
The temperature limiting device used with an 874 series gas booster water heater as part of a solar water heater installation must have the additional capability of receiving a hot water supply temperature of up to 99°C if the solar preheat water heater does not have an over temperature protection system to limit the water to no greater than 90°C, such as the Rheem Premier Hiline thermosiphon closed circuit system.
Warning: Temperature controllers must not be fitted to this water heater as part of a solar water heater
system (874 series) because water at a temperature much higher than the controller setting can be delivered. If a solar preheater has been installed to an existing water heater installation, then all controllers
must be disconnected and removed.
Page 46
INSTALLATION – WATER HEATER
46
Where a temperature limiting device is installed adjacent to the gas booster water heater, the cold water line to the temperature limiting device can be branched off the cold water line either before or after the isolation
valve and pressure limiting valve to the solar storage tank, but it MUST BE
before the non return valve prior to an open circuit direct system. The cold water line to the temperature limiting device can be branched off the cold water line either before or after the non return valve prior to a closed circuit indirect system. If an expansion control valve is required, it must always be installed after the non return valve and be the last valve prior to the solar storage tank.
Warning: A non return valve MUST BE installed on the cold water line to the solar storage tank AFTER
the cold water branch to a temperature limiting device prior to an open circuit direct system. Due to the higher water temperatures generated under certain conditions in the solar collectors of an open circuit direct solar water heater, an additional effective back-flow prevention device also should be used as an extra safeguard. Valve manufacturer RMC recommends Dual Check Valve model N7150, as being suitable for this application.
If a combination isolation valve and non return valve (duo or trio valve) is installed on the cold water line to an open circuit direct solar water heater and the cold water line to the temperature limiting device branches off after this valve, then a second non return valve must be installed between the cold water branch and the solar storage tank. Due to the higher water temperatures generated under certain conditions in the solar collectors of an open circuit direct pumped solar water heater, an effective back-flow prevention device should be used as the second non return valve as an extra safeguard. Valve manufacturer RMC recommends Dual Check Valve model N7150, as being suitable for this application.
If a pressure limiting valve is installed on the cold water line to the solar water heater and the cold water line to a temperature limiting device branches off before this valve or from another cold water line in the premises, then a pressure limiting valve of an equal pressure setting may be required prior to the temperature limiting device.
Gas Booster for Open Circuit Direct Solar Preheater Installation
Two Temperature Zones Using a Temperature Li miting Device
Gas Booster for Closed Circuit Solar Preheater Installation
Two Temperature Zones Using a Temperature Li miting Device
From solar
storage tank
To solar
storage tank
from solar
storage tank
to solar
storage tank
Page 47
INSTALLATION – WATER HEATER
47
CIRCULATED HOT WATER FLOW AND RETURN SYSTEM
A Rheem continuous flow water heater cannot be installed as part of a circulated hot water flow and return system in a building.
If a circulated flow and return system is required, it is necessary to bypass the continuous flow water heater and install a secondary water heater connected to the hot water flow and return line and supplied from the continuous flow water heater. The secondary water heater must be a storage water heater able to provide a
hot water outlet temperature of at least 60°C. Note: The thermostat must always be set to at least 60°C.
Temperature Limiting Device
A temperature limiting device cannot be installed in circulated hot water flow and return pipe work. The tempered water from a temperature limiting device cannot be circulated. Where a circulated hot water flow and return system is required in a building, a temperature limiting device can only be installed on a dead leg, branching off the circulated hot water flow and return pipe.
If circulated tempered water were to be returned back to the water heater, depending on the location of the return line connection on the water supply line to the water heater, then either:
water will be supplied to the cold water inlet of the temperature limiting device at a temperature
exceeding the maximum recommended water supply temperature, or
when the hot taps are closed no water will be supplied to the cold water inlet of the temperature limiting
device whilst hot water will continue to be supplied to the hot water inlet of the temperature limiting device.
These conditions may result in either water at a temperature exceeding the requirements of AS/NZS 3500.4 being delivered to the hot water outlets in the ablution areas, or the device closing completely and not delivering water at all, or the device failing. Under either condition, the operation and performance of the device cannot be guaranteed.
Recirculated Hot Water Flow and Return - Continuous flow Gas Water Heater
REDUCING HEAT LOSSES
The hot water line from the water heater and the pipe work between the solar storage tank, if one is installed, and the gas booster water heater must be insulated in accordance with the requirements of AS/NZS 3500.4. The insulation must be weatherproof and UV resistant if exposed. The insulation must be fitted up to the connections on the both the underside of the water heater and the solar storage tank.
Page 48
INSTALLATION – WATER HEATER
48
WATER TEMPERATURE DIAGRAMS
874 Series - Kitchen and Bathroom Controllers
874 Series - Kitchen Controller Only
874 Series - Bathroom Controllers Only
874 Series - No Controllers Notes:
Temperature Limiting Devices – refer to “Hot Water Delivery” on page 45.
Factory preset outlet temperature setting is:
874 series 55°C
55°C
55°C
55°C
55°C
55°C
Page 49
INSTALLATION – WATER HEATER
49
Dimensions And Technical Data
Model
874 027
Rated delivery
(@ 40°C rise)
litres / min
16.5
Recovery
(@ 25°C rise)
litres / min
27
Mass Empty
kg
24
Gas Details
Hourly Gas
Consumption
(MJ)
Min Gas Pressure
(kPa)
Test Point Gas Pressure (kPa)
Max Gas Pressure
(kPa)
minimum maximum
Model
027 027 027 027 027
Natural 205 1.13 0.193 0.905 3.50
LPG 205 2.75 0.277 1.430 3.50
Model numbers: N = Natural, L = LPG Letter N or L is included in the model number, eg 874027NFZ, to denote gas type. F = Frost protection. Specifications are subject to change with ongoing product improvements.
Page 50
INSTALLATION – WATER HEATER
50
DIMENSIONS – STANDARD CONTROLLERS
Kitchen Controller (Standard)
Bathroom Controller (Standard)
Page 51
INSTALLATION – WATER HEATER
51
DIMENSIONS – DELUXE CONTROLLERS
120
120
24
120
Deluxe Controller – Cover Closed
UUP
Set Bath Fill Water Volume
and Temperature
Bath
Water
Volume
Bath Fill Temp
Bath Fill
1. 2. 3. 5. 7.
Press Bath Fill Button
(Red light on)
4.
Open hot tap
Bath Fill completed (automatic)
Bath Fill Button
(Red light flashes)
6.
Close hot tap
Press Bath
Fill Button
(Red light on)
BATH FILLBATH FILL
Hot Water
Press
ACTIVE
Light on
ON/OFF
Adjust
Temperature
Open hot
tap
1. 2. 3. 4.
160 160
120120
Deluxe Controller – Cover Open
Page 52
INSTALLATION – WATER HEATER
52
TYPICAL INSTALLATION – OUTDOOR LOCATION
TYPICAL INSTALLATION
ELECTRONIC CONTINUOUS FLOW GAS WATER HEATER
EXTERNAL MODELS 874 SERIES
NZS 5261
Page 53
INSTALLATION – WATER HEATER
53
TYPICAL INSTALLATION – GAS BOOSTER FOR SOLAR WATER HEATER
Solar Loline Open Circuit With An In-Series Gas Booster Water Heater (Top)
Solar Premier Loline Closed Circuit With An In-Series Gas Booster Water Heater (Bottom)
NZS:5261
NZS: 5261 NZS:5261
NZS:5261
TOP Solar Loline Open Circuit with an In-Series Gas Booster Water Heater
Bottom Solar Premiere Loline Closed Circuit with an In-Series Gas Booster Water Heater
Page 54
INSTALLATION – WATER HEATER
54
[Type a quote from the document or the summary of an interesting point. You can position the text box anywhere in the document. Use the Text Box Tools tab to change the formatting of the pull quote text box.]
Solar Premiere Hiline Closed Circuit with an In-Series Gas Booster Water Heater
NZS:5261
Solar Hiline Open Circuit with an In-Series Gas Booster Water
NZS:5261
Page 55
55
CONNECTIONS – PLUMBING
CONNECTION SIZES
Model
874 027
Hot water connection R¾/20
Cold water connection R¾/20
Gas inlet connection R¾/20
All plumbing work must be carried out by a qualified person and in accordance with the National Plumbing Standard AS/NZS 3500.4 and local authority requirements.
All gas work must be carried out by a qualified person and in accordance with the New Zealand Gas Installations Standard NZS 5261 and local authority requirements.
WATER INLET AND OUTLET
All pipe work must be cleared of foreign matter before connection and purged before attempting to operate the water heater. All olive compression fittings must use brass or copper olives. Use thread sealing tape or approved thread sealant on all fittings.
A full flow gate valve or ball valve must be installed on the cold water line or solar preheat water line to the water
heater. A non return valve or stop tap must not be installed. An acceptable arrangement is shown in the
diagram. Refer also to “Hot Water Delivery” on page 45 and to “Mains Water Supply” on page 44.
A disconnection union must always be provided at the cold water inlet and hot water outlet on the water heater to allow for disconnection of the water heater.
Insulation used on the cold and hot water lines must extend up to the cold water inlet and hot water outlet of the water heater.
Notes:
It is essential all pipe connections be correctly aligned,
otherwise component connections within the water heater may be strained and / or components themselves misaligned. It is recommended also, wherever possible, pipe connections be made at the water heater first and final pipe runs be made in soft copper pipe to allow some adjustment for misalignment.
Use the spanner flats on the water heater fittings and
take care to avoid twisting the water inlet and outlet pipes inside the jacket.
874 series gas booster water heaters do not need to
be installed with a solar bypass valve.
The maximum supply temperature to the water heater
when used as an in-series gas booster for a solar preheat water heater is 80°C.
HOT
WATER
POWER
CORD
PRESSURE
LIMITING
VALVE
GATE VALVE
OR
BALL VALVE
GAS
COCK
COLD
WATER
GAS
Gas Water Heater
Cold and Hot Water Connection Details
HOT
WATER
POWER
CORD
GATE VALVE
OR
BALL VALVE
GAS
COCK
SOLAR
PREHEAT
WATER
GAS
Gas Booster for a Solar Preheater
Solar Preheat and Hot Water
Page 56
CONNECTIONS – PLUMBING
56
PIPE SIZES
The pipe sizing for hot water supply systems should be carried out by persons competent to do so, choosing the most suitable pipe size to ensure adequate flow for each individual application. Reference to the technical specifications of the water heater and local regulatory authority requirements must be made.
To achieve true mains pressure operation, the cold water line to the water heater should be the same size or bigger than the hot water line from the water heater.
The minimum recommended cold pipe or solar preheat pipe and hot pipe size is DN20.
IN-SERIES BOOST WATER HEATER
The pipe work between the solar storage tank (if one is installed) and the gas booster water heater has a
minimum recommended pipe size of DN20, MUST BE
of copper and be fully insulated in accordance with the requirements of AS/NZS 3500.4. The insulation must be weatherproof and UV resistant if exposed. The insulation must be fitted up to the connections on both the solar storage tank and the gas booster water heater. A full flow isolation valve must be installed on the water line to the gas booster water heater.
GAS INLET
The gas connection is made at the underside of the water heater. The pipe work must be cleared of foreign matter before connection and purged before attempting to operate the water heater. An isolation valve and disconnection union must be installed to allow servicing and removal of the water heater (refer to the
diagram on page 54).
Note: Refer to the Gas Installations Standard NZS 5261 for the correct method of sizing the gas supply pipe
to the water heater. The pipe size selection must take into account the high gas input of this water heater
(refer to table on page 49) as well as all of the other gas appliances in the premises.
Warning: Always isolate the water heater before pressure testing the gas supply system. Disconnect the
water heater after the isolation valve to prevent the risk of serious damage to the gas control. Warranty does not cover damage of any nature resulting from failure to observe this precaution. Refer to rating label for gas types and pressures.
Page 57
57
CONNECTIONS – ELECTRICAL
All electrical work and permanent wiring must be carried out by a qualified person and in accordance with the Wiring Rules AS/NZS 3000 and local authority requirements.
Warning: Temperature controllers must not be fitted to this water heater (874 series) as part of a solar
water heater system or if a Water Star water heater is installed because water at a temperature much higher than the controller setting can be delivered. If a solar preheater has been installed to an existing water heater
installation, then all controllers must be disconnected and removed.
The water heater is supplied with a 1.8 metre lead and plug and requires a weatherproof 240 V 50 Hz general purpose outlet (GPO) to be located within 1.2 metres of the installation. The GPO must be clear of the flue exhaust, draining water, gas supply pipe and water connections.
The power consumption of the water heater is:
Component
Power
consumption
Comments
Gas water heater 80 Watts 874027 – Burner on, anti frost device inactive
175 Watts Burner on, anti frost device active
The water heater will only operate on a sine wave at 50 Hz. Devices generating a square wave cannot be used to supply power to the water heater.
Page 58
58
INSTALLATION – CONTROLLERS
CONTROLLERS
The Rheem 874 series can be installed with Rheem controllers to enable the user to control the temperature of the delivered water from the outlet of the water heater.
There are two families of Rheem controllers suitable for installation with this water heater. These are the standard controllers and the Deluxe controllers.
Standard Controllers
There are three types of standard controller. They are the Kitchen controller (Rheem PN 299853), Bathroom1 controller (Rheem PN 299854) and the Bathroom2 controller (Rheem PN 299855).
The standard controllers are suitable for use on all 874 models.
The standard controllers are identified by a ‘K’ (Kitchen controller), ‘B1’ (Bathroom1 controller) or ‘B2’ (Bathroom2 controller) located on the front bottom left hand corner of the standard controller.
Deluxe Controllers
There are three types of Deluxe controller. They are the Kitchen Deluxe controller (Rheem PN 299861), Bathroom1 Deluxe controller (Rheem PN 299862) and the Bathroom2 Deluxe controller (Rheem PN 299863).
The Deluxe controllers are suitable for use on all 874 models.
The Deluxe controllers are identified by a ‘K’ (Kitchen Deluxe controller), ‘B1’ (Bathroom1 Deluxe controller) or ‘B2’ (Bathroom2 Deluxe controller), located under the front panel, to the bottom left hand corner adjacent to the BATH FILL VOLUME label.
The standard and Deluxe controllers are designed to be hard wired into the water heater using either the Kitchen controller cable (Rheem PN 299856) or the Bathroom controller cable (Rheem PN 299857).
Notes:
Where more than one controller is installed, the second or third controller must be of the same family.
A standard controller can only be installed with another standard controller(s) and a Deluxe controller
can only be installed with another Deluxe controller(s). A standard controller(s) and a Deluxe controller(s) cannot be connected to the same water heater.
One, two or three controllers can be installed. Only one of each type of controller can be connected to
the water heater. Therefore, a maximum of three controllers only can be connected to each water heater.
A Bathroom2 controller can only be installed if a Bathroom1 controller is installed and a Bathroom2
Deluxe controller can only be installed if a Bathroom1 Deluxe controller is installed.
An additional Kitchen controller cable or Bathroom controller cable can be used if an extension of the
cable length is required. It will be necessary to cut an opposite end off both cables to be installed in order to wire them together. Alternatively, the cables may be extended using two-core flex with a minimum cross-sectional area of 0.5 mm2.
Other manufacturers’ controllers are not suitable for use and cannot be installed with this water heater.
Warning: Temperature controllers must not be fitted to this water heater (874 series) as part of a solar
water heater system, water at a temperature much higher than the controller setting can be delivered. If a
solar preheater has been installed to an existing water heater installation, then all controllers must be
disconnected and removed.
Page 59
INSTALLATION – CONTROLLERS
59
Location – The controllers must be installed in dry, shaded and clean locations. Do not install the controllers:
Near a heat source, such as a cook top, stove or oven. Heat, steam and smoke will interfere with the
electronic components of the controllers.
In direct sunlight.
In or near a wet area. The controllers are not waterproof. Water may damage the controllers.
Outdoors. The controllers are not weatherproof.
KITCHEN CONTROLLER
The standard Kitchen controller (Rheem PN 299853) or Kitchen Deluxe controller (Rheem PN 299861) is to be installed in the kitchen or laundry only. It has a minimum temperature setting of 37°C and a maximum temperature setting of:
874 series 55°C
Choose a suitable location for the Kitchen controller, away from water, heat and sunlight.
Kitchen Controller (Standard) Components
Kitchen Deluxe Controller Components
screw x 2 controller screw
Kitchen controller (standard) base plate
screw x 2 controller screw
Kitchen Deluxe controller
base plate
Page 60
INSTALLATION – CONTROLLERS
60
Wiring installation:
1. Penetrate the wall with a 30-35 mm hole at the controller location.
2. Install the Kitchen controller cable between the location of the controller and the water heater.
3. Remove the base plate from the controller.
4. Draw the cable through the central hole in the base plate.
5. Fix the base plate to the wall using suitable screws and wall anchors.
Ensure the projections in the base plate are pointing upwards.
6. Connect the cable to the two terminals on the back of the controller (connections are not polarity
sensitive).
Ensure the connecting screws are seated tightly.
7. Place the controller over the base plate.
Ensure the projections in the base plate fit into the housings in the controller.
8. Fix the controller to the base plate at the bottom of the controller, using the controller screw provided.
9. Proceed to “Connecting the Controller(s) to the Water Heater” on page 64.
Kitchen Controller (Standard and Deluxe) Installation
Concealed Cable
controller
cable
screws
terminal
screws
controller screw
base plate
wall
penetration
suitable wall
anchors
projections
Page 61
INSTALLATION – CONTROLLERS
61
If it is necessary to have an exposed wiring installation, follow this procedure omitting Steps 1 and 4, and make an opening in the thin section in the underside of the controller to accommodate the cable (as shown in the diagram), prior to Step 6.
Kitchen Controller (Standard and Deluxe) Installation
Exposed Cable
controller
cable
screws
terminal
screws
controller
screw
base plate
opening
suitable wall
anchors
projections
Page 62
INSTALLATION – CONTROLLERS
62
BATHROOM1 AND BATHROOM2 CONTROLLERS
If only one Bathroom controller is to be installed, the standard Bathroom1 Controller (Rheem PN 299854) or the Bathroom1 Deluxe controller (Rheem PN 299862) must be used. If two Bathroom controllers are to be installed, one must be a standard Bathroom1 controller and the other must be a standard Bathroom2 controller (Rheem PN 299855) or one must be a Bathroom1 Deluxe controller and the other must be a Bathroom2 Deluxe controller (Rheem PN 299863).
They have a minimum temperature setting of 37°C and a maximum temperature setting of:
874 series 50ºC
The method of installation for the standard Bathroom1 and Bathroom2 controllers and the Bathroom1 Deluxe and Bathroom2 Deluxe controllers is identical.
Choose a suitable location for each Bathroom controller, away from water, heat, and sunlight. The Bathroom controllers are supplied with a 250 mm length of wire with connectors to mate with the Bathroom controller cable.
Notes:
It is not recommended to have exposed wiring in a bathroom.
Do not apply sealant to the controller cable.
Bathroom1 and Bathroom2 Controller Components
Bathroom1 Deluxe and Bathroom2 Deluxe Controller Components
screw x 2 controller screw
base plate foam packing Bathroom controller (standard)
screw x 2 controller screw
base plate
foam packing Bathroom Deluxe controller
Page 63
INSTALLATION – CONTROLLERS
63
Wiring installation:
1. Penetrate the wall with a 30-35 mm hole at the controller location.
2. Install the supplied cable between the location of the controller and the water heater.
3. Remove the base plate from the controller.
4. Peel off one side of the adhesive paper from the foam packing and adhere to the back face of the base
plate. This is the side without the projections.
5. Peel off the remaining adhesive paper from the foam packing.
6. Draw the cable through the central hole in the base plate.
7. Fix the base plate to the wall using suitable screws and wall anchors.
Ensure the projections in the base plate are pointing upwards.
8. Plug the controller wire into the Bathroom controller cable.
9. Place the controller over the base plate.
Ensure the projections in the base plate fit into the housings in the controller.
10. Fix the controller to the base plate at the bottom of the controller, using the screw provided.
11. Proceed to “Connecting the Controller(s) to the Water Heater” on page 64.
Bathroom Controller (Standard and Deluxe) Installation
controller
cable
screws
cable connectors
controller
screw
base plate
wall
penetration
suitable wall
anchors
adhesive paper
projections
foam packing
Page 64
INSTALLATION – CONTROLLERS
64
CONNECTING THE CONTROLLER(S) TO THE WATER HEATER
To connect the controller(s) to the water heater:
1. Ensure the electrical supply to the water heater is
switched off.
2. Unscrew and gently remove the electrical cover from the
underside of the water heater.
3. Draw the cable(s) through the electrical cover.
4. Connect a cable lug from each cable to each of the
remote controller terminals. Each cable has two cable lugs.
Ensure the terminal screws are seated firmly and there are no excess wire loops inside of the electrical cover.
The cable connections are non-polarised.
Three cable lugs, one from each type of controller,
can be connected to each remote controller terminal.
5. Place the cable(s) in the cable holder notches.
It is important to seat the cables into the cable notches. Failure to do this may cause an unstable contact or even disconnection of the cables from the terminals if the cables were to be pulled.
6. Refit the electrical cover to the water heater and replace
the screws.
7. Switch on the electrical supply to the water heater.
Upon completion of the installation of the controllers, it is necessary to test their operation through the complete range of functions (refer to “Temperature Control” on pages 9 to 38).
Upon completion and testing of the installation, explain to the householder the functions and operation of the controllers and the water heater.
If it is necessary to turn off the water heater on completion of the installation, such as on a building site or where the premises is vacant, follow the procedure “To Turn Off the Water Heater” on page 71.
CABLE
HOLDER
NOTCHES
CABLE
TERMINAL SCREWS
PROJECTION
SCREW x 3
ELECTRICAL COVER
Page 65
65
COMMISSIONING
All water heaters are tested and adjusted before dispatch from the factory, however further adjustments may become necessary because of local conditions.
TO TURN ON THE WATER HEATER
Open all of the hot taps in the house (don’t forget the shower).
Open the cold water isolation valve fully at the inlet to the water heater.
Air will be forced out of the taps.
Close each tap as water flows freely from it.
Check the pipe work for leaks.
Open the gas isolation valve fully.
Check the gas pipe work for leaks.
Plug in the water heater at the power outlet and switch on the electrical supply.
Turn on a controller, if one is fitted, by pressing the on / off button.
The light in the on / off button and the priority light (standard controller) or ACTIVE light (Deluxe controller) will both glow.
Open a hot tap.
The water heater will operate automatically.
Check to ensure the flow from each connected hot tap is sufficient to operate the water heater.
The minimum operating flow rate for all models is 3.0 litres per minute.
The automatic water governor incorporated in the water heater is not adjustable.
To complete the installation, it is necessary to check the gas supply pressure at the inlet to the water heater (refer to “Gas Inlet Pressure” on page 65), the minimum test point pressure and the maximum test point pressure (refer to “Burner Gas Pressure” on page 67).
Upon completion and testing of the installation, ensure the controller(s) is turned off (if fitted). Explain to the householder or a responsible officer the functions and operation of the water heater and the controllers (if fitted).
Warning: Upon completion of the installation and commissioning of the water heater, leave this guide
with the householder or a responsible officer. DO NOT
leave this guide inside of the cover of the water heater, as it may interfere with the safe operation of the water heater or ignite when the water heater is turned on.
GAS INLET PRESSURE IMPORTANT - CHECK
the gas supply pressure at the inlet to the water heater with the water heater and all other gas burning appliances in the premises operating (burners alight). The minimum gas supply pressure is:
Natural Gas 1.13 kPa LPG 2.75 kPa
If this minimum cannot be achieved, it may indicate the meter or the gas line to the water heater is undersized. It is important to ensure that an adequate gas supply pressure is available to the water heater when other gas burning appliances, on the same gas supply, are operating.
Page 66
COMMISSIONING
66
Gas Inlet Test Point Pressure
To check the gas inlet pressure:
1. Close any hot taps and ensure the
burners are not operating.
2. Close the gas isolation valve at the gas
inlet to the water heater.
3. Locate the gas inlet test point on the gas
connection to the water heater.
Remove the test point screw and
washer from the test point orifice.
Connect the manometer.
4. Open the gas isolation valve fully at the
gas inlet to the water heater.
5. Observe the gas pressure reading on
the manometer.
If the manometer reading is between the minimum and maximum inlet gas pressure ratings on the rating label, no adjustment is required.
If the manometer reading is below the minimum inlet gas pressure rating on the rating label, then either the gas pipe to the water heater is undersized and needs to be rectified or adjustment is required at the gas regulator.
If the manometer reading is above the maximum inlet gas pressure ratings on the rating label, then adjustment is required at the gas regulator.
6. Switch on the electrical supply at the power outlet to the water heater if it is not already switched on and
turn on a controller, if one is fitted, by pressing the on / off button.
7. Open a hot tap fully and ensure the burners are fully ignited.
It may be necessary to open a second tap.
8. Turn on all other gas burning appliances in the house which are on the same gas supply.
9. Observe the gas pressure reading on the manometer.
If the manometer reading is between the minimum and maximum inlet gas pressure ratings on the rating label, no adjustment is required.
If the manometer reading is below the minimum inlet gas pressure rating on the rating label, then either the gas pipe to the water heater is undersized and needs to be rectified or adjustment is required at the gas regulator.
If the manometer reading is above the maximum inlet gas pressure ratings on the rating label, then adjustment is required at the gas regulator.
10. Turn off the other gas burning appliances in the house.
11. If an adjustment was made during Step 9, repeat this procedure from Step 5.
12. Close the hot tap(s).
13. Close the gas isolation valve at the inlet to the water heater.
14. Remove the manometer and refit and tighten the test point screw and washer.
15. Open the gas isolation valve fully at the gas inlet to the water heater.
16. Open a hot tap again so the burners ignite.
17. Test for gas leaks.
18. Close the hot tap.
GAS INLET
INLET TEST
POINT ORIFICE
TEST POINT SCREW
WASHER
MANOMETER
Page 67
COMMISSIONING
67
BURNER GAS PRESSURE
It is necessary to check the burner gas pressure at both the minimum and maximum operational settings. To check and if necessary adjust the operational gas pressures, the electrical supply to the water heater must be switched on, the burners ignited and hot water must be flowing from a hot tap.
Warning: The removal of the front panel will expose 240 volt wiring. Take care not to touch wiring
terminals.
Minimum test point gas pressure
Refer to the rating label on the water heater for the minimum test point gas pressure.
1. Close any hot taps and ensure the burners are not
operating.
2. Turn off the controller(s), if one is fitted, by pressing the
on / off button and switch off the electrical supply at the power outlet to the water heater.
3. Remove the screws holding the front panel to the jacket.
4. Gently disengage the front panel and pull forward to
remove from the water heater.
5. Locate the burner pressure test point on the main burner
manifold.
Remove the test point screw and washer from the
test point orifice.
Connect the manometer.
6. Switch on the electrical supply at the power outlet to the
water heater and turn on a controller, if one is fitted, by pressing the on / off button.
7. Open the gas isolation valve fully at the gas inlet to the
water heater, if not already open.
8. Open a hot tap slowly until the burners ignite.
9. Press and hold down the MIN button and observe the
reading on the manometer.
“1L” is shown on the LED display.
10. Release the MIN button.
If the manometer reading observed in step 9 agrees with the rating label, no further adjustment is required.
11. To adjust, press and hold the adjuster button.
“LH” is shown on the LED display.
Note:
The adjuster button must be held down
continuously through steps 11 to 13.
12. Press and hold the MIN button and observe the reading
on the manometer.
The manometer reading will change as the test point
gas pressure adjusts.
Note: While the MIN button is pressed, the gas pressure will at first increase then decrease, cycling
between an upper gas pressure limit (39 on the LED display) and a lower gas pressure limit (01 on the LED display).
13. Release the MIN button when the reading on the manometer agrees with the rating label.
14. Release the adjuster button.
TEST POINT SCREW
WASHER
TEST POINT ORIFICE
MANOMETER
MIN. BUTTON
MAX. BUTTON
ADJUSTER BUTTON
DIP 1 SET OF DIP SWITCHES
1234
OFF ON
DIP1
1234
ON
1234
OFF ON
DIP2
MIN MAX ADJ
1234
ON
Page 68
COMMISSIONING
68
Notes:
If the burners extinguish and error code 11 or 12 starts to flash on the LED display:
release the MIN and adjuster buttons
close the hot tap
recommence the procedure from Step 8.
If the adjuster button is released before Step 13, clear any error code (if displayed) and recommence the
procedure from Step 8.
Maximum test point gas pressure
Refer to the rating label on the water heater for the maximum test point gas pressure.
Follow Steps 8 to 14 of the “Minimum test point gas pressure” procedure, but open the hot tap fully and use the MAX button instead of the MIN button. It may be necessary to open two or three hot taps fully, depending upon the model of water heater and the incoming cold water temperature.
Note: In Step 9, “3H” (874027 models) will be shown on the LED display.
After setting the minimum and maximum test point gas pressures:
Close the hot tap.
Remove the manometer and refit and tighten the test point screw and washer.
Open a hot tap again so the burners ignite.
Test for gas leaks.
Close the hot tap.
Turn off the controller, if one is fitted, by pressing the on / off button
Switch off the electrical supply at the power outlet to the water heater
Refit the front panel and screws to the water heater.
Clearing Error Code
If an error code does appear on the LED display during the installation and commissioning process, it will be necessary to clear the error prior in order to complete the installation.
To clear an error code:
switch off the electrical supply at the power outlet to the water heater
check the gas isolation valve at the gas inlet to the water heater is fully open
wait five (5) minutes
switch on the electrical supply at the power outlet to the water heater
Page 69
COMMISSIONING
69
PRESET OUTLET TEMPERATURE SETTING
The factory preset outlet temperature setting of the water heater is:
874 series 55°C
If a temperature controller is connected to the water heater, this will override the preset outlet temperature setting and the maximum temperature setting will be:
Maximum Outlet Temperature 874 series
Kitchen controller connected 55°C
Bathroom controller only connected 50°C
It is usually not necessary to check or adjust the factory preset outlet temperature setting of the water heater, unless the customer has a particular requirement for this to be done or it is to be installed as a gas booster to a solar water heater.
Gas Booster for a Solar Water Heater
Where an 874 series water heater is installed as a gas booster to a solar water heater, the preset outlet temperature setting must be set at 75°C for the system to operate correctly.
It will be necessary to check and if required to adjust the preset outlet temperature setting of the continuous flow water heater when:
it is installed as a gas booster as part of a solar water heater installation
it is an existing continuous flow water heater and a solar preheat water heater is then installed.
Notes:
Consideration must be given to the delivery temperature to any ablution and public areas such as a
bathroom, ensuite or public amenities. Refer to “Hot Water Delivery” on page 45 and to “Schematics of 2
Temperature Zones Using A Temperature Limiting Device” on page 46.
Page 70
COMMISSIONING
70
WARNING: TEMPERATURE CHANGE MUST ONLY BE MADE BY A QU ALIFIED INSTALLER OR RHEEM SERVICE CENTRE REPRESENTITIVE. SEVERE SCALD INJURIES COULD OCCUR IF BATHROOMS AND ENSUITES ARE NOT PROTECTCED BY A HOT WATER TEMPERING DEVICE.
TO CHECK OR ADJUST THE PRESET OUTLET TEMPERATURE SETTING
The temperature settings will be displayed on the LED display. The preset outlet temperature settings are:
874 series 38°C, 40°C, 42°C, 43°C, 45°C, 50°C, 55°C, 70°C and 75°C
It is necessary to have the electrical supply to the water heater switched on during stages of checking or adjusting the preset outlet temperature setting procedure.
Warning: The removal of the front panel will expose 240 volt wiring. Take care not to touch wiring
terminals. The adjustment must be carried out by a qualified person.
Warning: This procedure will involve the adjustment of dip switches. Adjustment of a dip switch should
only be made with an insulated tool.
To check or adjust the preset outlet temperature setting:
1. Switch off the electrical supply at the power outlet to the water heater.
2. Remove the screws holding the front panel to the jacket.
3. Gently disengage the front panel and pull forward to remove from the water heater.
4. Switch on the electrical supply at the power outlet to the water heater.
5. Switch dip switches 3 and 4 to the on (up) position on the DIP 1 set of DIP switches on the I.C. Board.
The current preset outlet temperature setting will show on the LED display.
If the temperature displayed on the LED display is the desired preset outlet temperature setting, then proceed to step 7, as no further adjustment is necessary.
874 series
If the water heater is to be used as a gas booster to a solar water heater and ‘55’ is shown on the display, then proceed to step 6, as further adjustment is necessary.
6. Press the MAX button to increase or the MIN button to decrease the
preset outlet temperature setting.
Each press of the MAX or MIN button will increase or decrease the preset temperature by one increment.
The MAX and MIN buttons are located underneath the DIP 1 and DIP 2 set of DIP switches.
874 series
The increments are 38°C, 40°C, 42°C, 43°C, 45°C, 50°C, 55°C, 70°C, and 75°C.
Set the temperature to 75°C on an 874 series water heater if it is installed as a gas booster to a solar water heater.
7. Switch dip switches 3 and 4 to the off (down) position.
The temperature display will go blank. The preset outlet temperature setting is now set.
8. Switch off the electrical supply at the power outlet to the water heater.
9. Refit the front panel and screws to the water heater.
DIP1
OFF ON
1
2
3
4
1
2
3
4
O
N
MIN. BUTTON
MAX. BUTTON
ADJUSTER BUTTON
DIP 1 SET OF DIP SWITCHES
123
4
OFF ON
DIP1
1234
ON
1234
OFF ON
DIP2
MIN MAX
ADJ
1234
ON
1
2
3
4
O
N
DIP1
OFF O
N
1
2
3
4
Page 71
COMMISSIONING
71
TO TURN OFF THE WATER HEATER
If it is necessary to turn off the water heater on completion of the installation, such as on a building site or where the premises are vacant, then:
Turn off the controllers(s) (if fitted) by pressing the on / off button.
The light in the on / off button will go out and the priority light (standard controller) or the ACTIVE light (Deluxe controller), if it is on, will go out.
Switch off the electrical supply at the power outlet to the water heater (refer to note below).
Close the gas isolation valve at the inlet to the water heater
Close the cold water isolation valve at the inlet to the water heater.
Drain the water heater if there is a risk of freezing conditions occurring (refer to “Draining The Water
Heater” on page 72).
Note:
The frost protection system will be rendered inoperable if electrical power is not available at the water heater. Damage caused by freezing due to the unavailability of power at the water heater is not covered by warranty (refer to “Warranty Exclusions” on page 73). If the power has been switched off to the water heater and there is a risk of freezing, then it is necessary to drain the water heater (refer to “Draining the Water
Heater” on page 72).
Page 72
72
DRAINING THE WATER HEATER
To drain the water heater:
Turn off the water heater (refer to “Turn Off The Water Heater” on page 71).
Open a hot tap (preferably the shower outlet).
Unscrew the two drain plugs, one each at the cold water inlet and hot water outlet, on the underside of
the water heater.
Water will drain from the water heater.
When water stops flowing from the water heater, close the hot tap.
Note: It is recommended not to screw the drain plugs back in, until the water heater is to be turned on again.
WATER SUPPLIES
Your water heater is manufactured to suit the water conditions of most New Zealand Town water supplies. However, there are some known water supplies that can have detrimental effects on the water heater Bore/Rain Water and its operation and / or life expectancy. If you are unsure of your water chemistry, you can obtain information from your local water supply authority.
This water heater is not suitable for connection to bore water or spring water unless a water treatment device is fitted and the PH is within 6.8-7.6. (Refer to Water Quality Page 73)
Page 73
73
RHEEM ELECTRONIC CONTINUOUS FLOW GAS WATER HEATER
WARRANTY (NEW ZEALAND ONLY)
WARRANTY CONDITIONS
Notes:
*Rheem New Zealand limited is the supplier of Rheem electronic continuous flow gas water heaters, manufactured by Paloma industries Ltd, a world leader in water heater technology and manufacture. **Refer to item 4 of warranty conditions. Rheem New Zealand reserves the right to transfer fully functional components from the defective water heater to the replacement water heater if required.
WATER QUALITY
Your water heater is manufactured to suit the water conditions of most New Zealand metropolitan water supplies. However, there are some known water supplies that can have detrimental effects on the water heater and its operation and / or life expectancy. If you are unsure of your water chemistry, you can obtain information from your local water supply authority plumber or merchant.
This water heater is not suitable for connection to bore, spring or rain water unless a water treatment device is fitted to buffer PH levels to between 6.8-7.6.
Components Installation Model Period Warranty
All components
Water heater installed in
any other than a single
family domestic dwelling
All models Year 1
New water heater (at Rheem’s discretion) or
component free of charge ** including
labour
All components
except heat
exchanger
Water heater installed in a
single family domestic
dwelling
All models
Year 1 to Year 3
New water heater (at Rheem’s discretion) or
component free of charge ** including
labour
Heat exchanger
Water heater installed in a
single family domestic
dwelling
All models
Year 2 to 10
10 Year Pro rata
10 year Pro Rate (i.e. in the 3
r
d
year 80% of
the heat exchanger and labour is covered,
and in the 8th year 20% of the part is
covered and labour is at the owners
expense).
1. This warranty is applicable only to water heaters
manufactured from 1st January 2001.
1. The water heater must be installed in accordance with the
Rheem water heater installation instructions, supplied with the water heater, and in accordance with all relevant statutory and local requirements in which the water heater is installed.
2. Where a failed component or water heater is replaced under
warranty, the balance of the original warranty period will remain effective. The replaced part or water heater does not carry a new warranty.
3. Where the water heater is installed outside the boundaries of
a metropolitan area as defined by Rheem or further than 25 km from a regional Rheem branch office, or an Accredited Service Centre, the cost of transport, insurance and travelling costs between the nearest Rheem accredited Service
Centre’s premises and the installed site shall be the owner’s responsibility.
4. Where the water heater is installed in a position that does not allow safe, ready access, the cost of accessing the site safely, including the cost of additional materials handling and / or safety equipment, shall be the owner’s responsibility.
5. The warranty only applies to the water heater and original or genuine (company) component replacement parts and therefore does not cover any plumbing or electrical parts supplied by the installer and not an integral part of the water heater, e.g. pressure limiting valve; isolation valves; non­return valves; electrical switches; pumps or fuse.
6. The water heater must be sized to supply the hot water demand in accordance with the guidelines in the Rheem water heater literature.
Page 74
Revision Date: 4th March 2010 317658B
74
WARRANTY EXCLUSIONS
1. REPAIR AND REPLACEMENT WORK WILL BE CARRIED OUT AS SET OUT IN THE RHEEM WATER HEATER WARRANTY, HOWEVER THE FOLLOWING EXCLUSIONS MAY CAUSE THE WATER HEATER WARRANTY TO BECOME VOID AND MAY INCUR A SERVICE CHARGE AND / OR COST OF PARTS.
a) Accidental damage to the water heater or any component,
including: Acts of God; failure due to misuse; incorrect installation; attempts to repair the water heater other than by a Rheem Accredited Service Centre or the Rheem Service Department.
b) Where it is found there is nothing wrong with the water
heater; where the complaint is related to excessive discharge from the temperature and / or pressure relief valve due to high water pressure; where there is no flow of hot water due to faulty plumbing; where water leaks are related to plumbing and not the water heater or water heater components; where there is a failure of gas, electricity or water supplies; where the supply of gas, electricity or water does not comply with relevant codes or acts.
c) Where the water heater or water heater component has failed
directly or indirectly as a result of: excessive water pressure; excessive temperature and / or thermal input; corrosive atmosphere; ice formation in the pipe work to or from the water heater; ice formation in the waterways of a water heater without a frost protection system; ice formation in the
water heater with a frost protection system where the waterways of a electricity supply has been switched off or has failed and the water heater has not been drained in accordance with the instructions; ice formation in the waterways of a water heater with a frost protection system due to an ambient temperature below -20°C (including wind chill factor); ice formation in the water ways of a water heater where the water heater has not been installed in accordance with the Rheem water heater installation instructions.
d) Where the water heater is located in a position that does not
comply with the Rheem water heater installation instructions or relevant statutory requirements, causing the need for major dismantling or removal of cupboards, doors or walls, or use of special equipment to bring the water heater to floor or ground level or to a serviceable position.
e) Repair and / or replacement of the water heater due to scale
formation in the waterways or the effects of corrosive water when the water heater has been connected to a scaling or corrosive water supply as outlined in the Owner’s Guide and Installation Instructions booklet.
2. SUBJECT TO ANY STATUTORY PROVISIONS TO THE CONTRARY, THIS WARRANTY EXCLUDES ANY AND ALL CLAIMS FOR DAMAGE TO FURNITURE, CARPETS, WALLS, FOUNDATIONS OR ANY OTHER CONSEQUENTIAL LOSS EITHER DIRECTLY OR INDIRECTLY DUE TO LEAKAGE FROM THE WATER HEATER, OR DUE TO LEAKAGE FROM FITTINGS AND / OR PIPE WORK OF METAL, PLASTIC OR OTHER MATERIALS CAUSED BY WATER TEMPERATURE, WORKMANSHIP OR OTHER MODES OF FAILURE.
Rheem New Zealand Ltd For service telepho ne
0800 657 335