Rheem 6024AS Specification

FORM NO. C11-210 REV. 1
Supersedes Form No. C11-208 Rev. 4
INDOOR COILS
RCQD­SUPER HIGH EFFICIENCY INDOOR COILS
Rheem Prestige Series®Indoor Coils are designed for use with Rheem outdoor units and are available for vertical upflow, horizontal left or horizontal right airflow. When matched with Rheem outdoor units, the coils provide a capacity range from 24,000 BTU/HR [7.04 kW] to 60,000 BTU/HR [17.6 kW].
Constructed of aluminum fins bonded to intergrooved
copper tubing.
Coils are tested at the factory with an extensive refriger-
ant leak check for improved quality control.
Coils have sweat fitting refrigerant connections.
Ideally suited for new installations or add on air
conditioning.
Condensate drain connections are
3
/4" [19.1 mm] N.P.T. for
ease of connection.
Coils are A.R.I. certified for system application with variety
of Rheem outdoor units.
Condensate drain pan is constructed of high grade, heat
resistant, corrosion free thermal-setting material.
Compatible with Germicidal Light System
earth friendly refrigerant
2 Rheem Manufacturing Company
RCQD—2417AS
Sweat
Variation A = 16 & 18 SEER Application
Coil Casing 17 = 17" [431.8 mm] 21 = 21" [533.4 mm] 24 = 24" [609.6 mm]
Nominal Capacity 24 = 24,000 BTUH [7.03 kW] 36 = 36,000 BTUH [10.55 kW] 48 = 48,000 BTUH [14.06 kW] 60= 60,000 BTUH [17.58 kW]
Design Series
Type of Coil Q = High Efficiency AC/Heat Pump Coil
with Expansion Valve
Coil
Rheem
MODEL NUMBER DATA
Coil Specifications/Airflow Pressure Drop
H = Horizontal airflow, U = Upflow
Model
Number
RCQD-
Type
Air
Flow
Approx.
Design
Air Flow
CFM [L/s]
Range
Face Area
Sq. Ft.
[m
2
]
Fins-in.
Rows Deep
Static Pressure Drop Through Wet Cooling Coil [kPa] (Inches H20) CFM [L/s]
600
[285]
700
[330]
800
[380]
900
[425]
1000 [470]
1100 [519]
1200 [565]
1300 [614]
1400 [660]
1500 [708]
1600 [755]
1700 [802]
1800 [850]
1900 [897]
HIGH EFFICIENCY COOLING COILS
3621AS U-H
720/1200
[340/566]
5.83
[0.54]
14/3
.08
[.020]
.10
[.025]
.13
[.032]
.16
[.040]
.18
[.045]
.21
[.052]
4821AS U-H
960/1600
[453/755]
5.83
[0.54]
14/3
.14
[.035]
.17
[.042]
.19
[.047]
.22
[.055]
.25
[.062]
.29
[.072]
.32
[.080]
4824AS U-H
960/1600
[453/755]
5.83
[0.54]
14/3
.11
[.027]
.13
[.032]
.15
[.037]
.17
[.042]
.19
[.047]
.23
[.057]
.25
[.062]
2417AS U-H
450/800
[212/378]
4.38
[0.41]
14/3
.06
[.025]
.10
[.025]
.14
[.035]
.17
[.042]
.21
[.052]
.25
[.062]
.29
[.072]
3624AS U-H
720/1200
[340/566]
5.83
[0.54]
14/3
.07
[.017]
.09
[.022]
.11
[.027]
.13
[.032]
.15
[.037]
.17
[.042]
6024AS U-H
1050/1700
[496/802]
5.83
[0.54]
14/3
.11
[.027]
.13
[.032]
.15
[.037]
.17
[.042]
.19
[.047]
.22
[.054]
.24
[.059]
.27
[.067]
Rheem Manufacturing Company 3
Coil Dimensions and Weights
Coil Application (No Downflow Applications)
Coils can be matched to heating products as listed in table below.
*Notes: U = Upflow
H = Horizontal
[ ] Designates Metric Conversions
Coil Model
RCQD-
2417AS
3621AS
4821AS
3624AS 4824AS 6024AS
Type
Air
Flow*
U-H U-H
U-H U-H U-H
U-H
U-H
U-H U-H U-H
Oil Gas
21 [533]
21 [533]
241/2[622] N/A
Coil
Model
Number
RCQD-3621AS RCQD-3624AS RCQD-4821AS
Connections
Sweat (in.) [mm]
Liquid Suction
I.D. I.D.
3
/8[9.53]
3
/8[9.53]
3
/8[9.53]
3
/8[9.53]
3
/8[9.53]
3
/8[9.53]
3
/4[19.05] 171/2[445] 197/
7
/8[22.23] 21 [533] 243/
7
/8[22.23] 241/2[622] 243/
7
/8[22.23]
7
/8[22.23] 241/2[622] 243/
7
/8[22.23] 241/2[622] 243/
A B
21 [533]
243/
Furnace Width
(In.) (mm)
2
[444]
171/
21 [533] 171/2[445]
21 [533] N/A
171/2[445] RXBA-AC
241/2[622] N/A 21 [533] RXBA-AC
Dimensions (In.) [mm]–Weight (lbs.) [Kg]
C
8 16
[505] 59 [27]28 [711]
4 16
[629] 74 [34]
4 16
[629] 80 [36]
4 16
[629]
4 16
[629] 80 [36]
4 16
[629] 80 [36]
28 [711] 28 [711]
Coil Weight (lbs.) [Kg.]
74 [34] 83 [38]28 [711]
Plenum
Adapter Upflow
N/A
RXBA-AC14 [356]
N/A N/A
RXBA-AC
Shipping Weight
(lbs.) [Kg.]
67 [38]RCQD-2417AS 83 [38] 90 [41]
90 [41]28 [711]RCQD-4824AS 90 [41]28 [711]RCQD-6024AS
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
RHEEM AIR CONDITIONING DIVISION
5600 Old Greenwood Road, Fort Smith, Arkansas 72908
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A. 4-05 DC FORM NO. C11-210 REV. 1
Supersedes Form No. C11-208 Rev. 4
Accessories
PLENUM ADAPTER ACCESSORY RXBA-AC
This plenum adapter accessory is for installation on cased indoor cooling and heat pump coils. This allows a nominal size cased coil to be installed on the next smaller size gas or oil furnace. NOTE:
This accessory is for installation on coil casings to fit gas or oil furnaces only – this accessory must not be used on elec­tric furnaces or heat pump air handlers. Consult the installation
instructions packaged with the accessory for proper installation. The RXBA-AC (upflow) can be ordered factory installed by desig­nation as “with adapters” in the coil model number.
PLENUM ADAPTER ACCESSORY RXBA-AE
This plenum adapter accessory is for use with the 24
1
/2" wide
cased indoor cooling and heat pump coils. This allows a 24
1
/2" wide cased coil to be installed on a 28" wide oil furnace. This is a field installed accessory only.
AIRFLOW
[ ] Designates Metric Conversions
FRONT VIEW
SIDE VIEW
PLENUM WIDTH
197/8
[505 mm]
Loading...