FURY DIRECT VENT GAS FROM RHEEM
We’re Venting Our Flexibility!
Fury DV – now with longer venting options
and vertical and horizontal vent extensions
Rheem Fury DV features
• Longer venting – up to 4 feet above the water heater and 4 feet
from an outside wall with 22DV50-38 and 22DV40S-36N
• Four feet horizontal coaxial vent material included
• Optional venting up to 4 feet vertical – order kit #SP20061
• Adjustable coaxial vent – allows installation flexibility because
the coaxial vent can swivel 360 degrees, uses outside air for
combustion and requires no electrical power
• Aluminum vent and cap base – to prevent staining
of building exterior
and more!
Residential water heaters
from Rheem
G
E
A
B
C
F
D
H
10"
3/4" N.P. T.
RELIEF VALVE
OPENING
2"
1/2"
24-3/4"
EXTERIOR
WALL
(H:
REAR VENTING
RANGE OF
ADJUSTMENT)
(G: SIDE VENTING
RANGE OF
ADJUSTMENT)
FURY DIRECT VENT GAS FROM RHEEM
HOT WATER
CONNECTION
COLD WATER
CONNECTION
UPPER INLET
BOX ASSEMBLY
Available in 40 Gallon Short – 50 Gallon Tall Gas Models
6-Year Limited Tank and Parts Warranty*
With ProtectionPlus™the 6-Year Limited Tank Warranty Becomes 10 Years!
Adjustable coaxial vent allows
•
installation flexibility because
the coaxial vent can swivel
360 degrees, uses outside air
for combustion and requires no
electrical power
Aluminum vent and cap base to prevent staining
•
of building exterior
Brass drain valve
•
Factory installed temperature and pressure
•
relief valve
R-Foam®insulation for superior heat retention
Get 4 More Years!
pgradeable warranty
U
with ProtectionPlus
DESCRIPTION FEATURES DIMENSIONS ENERGY INFO.
T
Y
GAL. THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. VENT HT. DIAMETER GAS CONN. SIZE SIDET&P WT. FACTOR OPER. COSTS
P
AP. MODEL NUMBER
C
E
50 22DV50-40N* 40 40.4 85 68 57 21-3/4 14-1/4 5 51-1/4 164 0.58 $235
TALL
50 22DV50-38 38 38.4 85 68-108† 57 21-3/4 14-1/4 6 51-1/4 164 0.58 $235
SHORT
40 22DV40S-36N* 36 36.4 65 63-98† 48-1/4 21-3/4 14-1/4 6 43 152 0.59 $231
VENTING – ROUGHING IN DIMENSIONS (INCHES)
YPE NUMBER AVAIL.
T
TALL 22DV50-40N N/A 8-1/8 18-1/8 3-1/8 13-1/8 N/A
TALL 22DV50-38
SHORT 22DV40S-36N
MODEL 4' VENTING SIDE VENTING (G) REAR VENTING (H) OPTIONAL HEIGHT (A)
•
Exclusive Rheemglas®tank lining resists
•
corrosion and prolongs tank life
GAS INPUT IN RECOVERY IN FIRST HOUR HT.TO TANK HT.TO VENT HT.TO SHIP. ENERGY AVG. ANN.
NAT. NAT. NAT.
MIN. MAX. MIN. MAX.
Horizontal
& Vertical
8-1/8 48 3-1/8 43 72-107†
8-1/8 48 3-1/8 43 63-98†
A
BC DEF(LBS)
ITH VENT KIT #SP20061
W
Heat saving flue baffle design
•
Gas control and combination thermostat
•
Anode rod equalizes aggressive water action
•
Durable plastic formula dip tube
•
Meets or exceeds National Appliance Energy
•
Conservation Act (NAECA) requirements
See Residential Warranty Information Brochure for complete
*
arranty information.
w
Energy Factor and Average Annual
Operating Costs based on D.O.E.
(Department of Energy) test procedures.
D.O.E. national average fuel rate natural
gas 91¢/therm; LP $1.23/gallon.
NAT. NAT.
* For SCAQMD rule 1121 compliance.
† With vertical Vent Kit #SP20061.
• If side wall is combustible material,
1" clearance must be included in adjustment range.
NOTE: Maximum adjustment range for vent system is 10"
for 22DV50-40N; 40" for 22DV40S-36N and 22DV50-38.
Review installation manual before
In keeping with its policy of continuous progress and product improvement,
Rheem reserves the right to make changes without notice.
installation.
Rheem Water Heating • 101 Bell Road, Montgomery, AL 36117-4305
800-621-5622 • sales@rheem.com • www.rheem.com
Rheem Canada Ltd./Ltée • Water Heater Division
Residential water heaters
128 Barton Street West, Hamilton, Ontario L8N 3P3
Not all models are available in Canada.
Printed in U.S.A. 05/07 WP Form No. 107-1 Rev. 1
from Rheem