Rheem MPs Series, 180536 R, 180540 E, 180536, 180540 Installation Instructions Manual

This water heater must be installed and serviced by an authorised person.
Please leave this guide with the householder.
Installation Instructions
Air Sourced Split
Heat Pump Module
MPs Series
PATENTS
This water heater may be protected by one or more patents or registered designs
in the name of Rheem Australia Pty Ltd.
TRADE MARKS
®
Registered trademark of Rheem Australia Pty Ltd.
™ Trademark of Rheem Australia Pty Ltd.
Note: Every care has been taken to ensure accuracy in preparation of this publication.
No liability can be accepted for any consequences,
which may arise as a result of its application.
Notice to Victorian Customers from the
Victorian Plumbing Industry Commission.
This water heater must be installed by a licensed person as required by
the Victorian Building Act 1993.
Only a licensed person will give you a Compliance Certificate, showing that the work complies with all the relevant standards. Only a licensed person will have insurance protecting their workmanship for 6 years. Make sure you use a licensed person to install this water heater and ask for your Compliance Certificate.
3
CONTENTS
HOUSEHOLDER – This installation instruction booklet is intended for
the installer but you may find it of interest.
Installation .............................................................................................. 4
Heat Pump And Tank Assembly ......................................................... 11
Connections – Electrical ..................................................................... 30
Commissioning .................................................................................... 32
Water Supplies ..................................................................................... 36
Warranty Note ...................................................................................... 39
4
INSTALLATION
THE HEAT PUMP MODULE OF THIS WATER HEATER IS FOR OUTDOOR INSTALLATON ONLY.
The installation must comply with the requirements of AS/NZS 3500.4, AS/NZS 3000 and all local codes and regulatory authority requirements. In New Zealand, the installation must conform with Clause G12 of the New Zealand Building Code.
This water heater is recommended for connection to a 24 hour per day power supply.
All packaging materials must be removed from the heat pump module prior to its installation. This includes the removal of the cardboard base of the carton from the underside of the module.
STORAGE TANK AND HEAT PUMP MODULE
The heat pump water heater is made of two main components, the storage tank and the heat pump module. For transport and handling (weight) purposes both items are shipped separately. The water heater must not be operated until both components are installed, connected and purged of air. Refer to “Heat Pump
and Tank Assembly” on page 11.
Take care when handling the heat pump module. The jacket of the heat pump module needs to be handled gently so as not to cause damage.
Care must be taken during transportation and handling. Do not lay the heat pump module down and do not tilt the heat pump module more than 30° from the vertical. This will displace the compressor lubricating oil. If the
heat pump module has been tilted more than 30° from the vertical during handling, it will need one hour to drain back before the power to the water heater can be switched on, otherwise damage to the compressor may result.
Warning: This heat pump module is designed to be installed with a purpose
built water heater storage tank and may not be used for any other purpose.
INSTALLATION
5
HEAT PUMP MODULE LOCATION
The heat pump module is suitable for outdoor installation only. The heat pump
module‟s position is to be chosen with noise, safety and service in mind. Make
sure people (particularly children) will not accidentally touch the air inlet louvres and outlet grille and that they are clear of obstructions and shrubbery.
It is advisable to install the heat pump module away from bedroom or living room windows as the system components can generate a level of noise whilst they are operating. Consider the location in relation to neighbours‟ bedrooms and living room windows.
Clearance must be allowed for servicing of the heat pump module. It must be accessible without the use of a ladder or scaffold. Make sure the heat pump module‟s top and front covers and system controls can be removed for service.
You must be able to read the information on the rating plate of the heat pump module. Remember you may have to remove the heat pump module later for servicing.
It is recommended the heat pump module be installed at ground or floor level and must stand vertically upright.
The heat pump module must be installed against a wall and on a level slab or solid base with a minimum size of 600 mm wide x 600 mm deep. The heat pump module must be secured using the wall bracket and four feet brackets provided. Refer to “Heat Pump and Tank Installation” on page 11.
A clearance of at least 300 mm is required perpendicular from both the side air inlet louvres and the outlet grille to any wall or obstruction. Refer to the
dimensions diagram on page 9.
The heat pump storage tank and heat pump module must be installed within four (4) metres of each other. The heat pump flow and return pipes connecting the heat pump storage tank to the heat pump module must not exceed four (4) metres in length each and must not contain more than 4 x 90º bends each. All changes in direction of the pipe work must be made using bends. The pipe work should not contain elbows.
The water heater must not be installed in an area with a corrosive atmosphere where chemicals are stored or where aerosol propellants are released. Remember the air may be safe to breathe, but the chemicals may attack the materials used in the heat pump system.
INSTALLATION
6
Note
These instructions cover only the installation of the heat pump module and the connections made between the heat pump module and storage tank. Refer to the Owner‟s Guide and Installation Instructions supplied with the storage tank for further information including:
where and how to locate the heat pump water heater the dimensions of the heat pump water heater and any clearances
required from surrounding objects
how to connect the heat pump water heater to the electricity supply and to
the plumbing system
how to operate the heat pump water heater what to do if something goes wrong.
FREEZE PROTECTION
The water heater has a freeze protection system. The freeze protection system will protect the water heater from damage, by preventing ice forming in the waterways of the water heater, in the event of freezing conditions occurring.
If the ambient air temperature falls below 4°C and the heat pump module is not operating, the system will operate the circulator periodically. During this freeze protection cycle, the circulator will operate for three (3) minutes and then rest for fifteen (15) minutes, before the cycle is recommenced. Water is circulated from the storage tank through the heat pump circuit, to prevent freezing in the connecting pipe work and heat pump module.
Warning: In areas where the ambient air temperature may fall below 0°C, power must be available to the water heater at all times to prevent freezing in the heat pump circuit.
The system must be installed with the heat pump circuit hot and cold pipes fully insulated with closed cell polymer insulation with a minimum thickness of 13 mm. Thicker insulation may be required to comply with the requirements of AS/NZS 3500.4. The water heater has NO WARRANTY for freeze damage if the heat pump circuit hot and cold pipes are not suitably insulated or if power is unavailable at the water heater.
INSTALLATION
7
MAINS WATER SUPPLY
Where the mains water supply pressure exceeds that shown in the table below, an approved pressure limiting valve is required. Refer to the Owner‟s Guide and Installation Instructions supplied with the storage tank for the position of the pressure limiting valve.
Model
270, 325, 410
Relief valve setting
1000 kPa
Expansion control valve setting *
850 kPa
Max. mains supply pressure
With expansion control valve
680 kPa
Without expansion control valve
800 kPa
Min. mains supply pressure
200 kPa
* Expansion control valve not supplied with the water heater.
A minimum water supply pressure of 200 kPa is required to enable the heat pump circulator and heat pump system to operate effectively.
TANK WATER SUPPLY
If the water heater is supplied with water from a tank supply and a minimum water supply pressure of 200 kPa at the water heater cannot be achieved, then a pressure pump system must be installed to allow the heat pump circulator to operate and avoid air locks in the circuit. Care must be taken to avoid air locks. The cold water line from the supply tank should be adequately sized and fitted with a full flow gate valve or ball valve.
PURGING AIR FROM THE SYSTEM
The water heater system must be purged of air prior to operation, using the manual air bleed valve supplied on the storage tank. Failure to bleed the air out of the connecting pipe work and heat pump module will result in non-operation of the circulator and failure of the heat pump to operate due to overheating.
INSTALLATION
8
CONDENSATE DRAIN
A drain line must be fitted to the heat pump module‟s condensate drain to carry the discharge clear of the water heater. The drain line can be extended using 12 mm rigid poly hose or conduit. The pipe work from the condensate drain should be as short as possible, and fall all the way from the water heater with no restrictions. It should have no more than three right angle bends in it. The outlet of the drain line must be in such a position that flow out of the pipe can be easily seen - but arranged so water discharge will not cause damage or nuisance.
The condensate drain line must not be connected to the relief valves drain lines but may discharge at the same point.
WARNING
This water heater is only intended to be operated by persons who have the experience or the knowledge and the capabilities to do so. This water heater is not intended to be operated by persons with reduced physical, sensory or mental capabilities, i.e. the infirm, or by children. Children should be supervised to ensure they do not interfere with the water heater.
This water heater uses 240 V AC electrical power for operation of the control systems and the electrically operated components. The removal of the access cover(s) will expose 240 volt wiring. They must only be removed by an authorised or qualified person.
ENVIRONMENT
At the end of the service life of the heat pump water heater and prior to the water heater being disposed of, a person qualified to work with refrigerants must recover the refrigerant from within the sealed system. The refrigerant must not be vented to atmosphere. Phone your nearest Rheem Service Department or Accredited Service Agent to arrange for an inspection.
INSTALLATION
9
DIMENSIONS AND TECHNICAL DATA
elevation plan view
Heat pump module models
180536 (R)
180540 (E)
Maximum rated power input
watts
3600
Rated heat pump power input
watts
800
Booster element ratings
kW
2.4, 3.6
Refrigerant type
R134a
Refrigerant circuit pressure
kPa
3000
Mass heat pump module
kg
46
Storage tank capacity
litres
270
325
410
Boost capacity*
litres
180
180
200
Mass tank empty
kg
71
88
112
Mass tank full
kg
341
413
522
* The boost capacity of a low watts density or other than a 2.4 kW or 3.6 kW heating unit, if used, is 100 litres (270 and 325 litre storage tanks) or 125 litres (410 litre storage tank).
Technical data is subject to change.
INSTALLATION
10
TYPICAL INSTALLATON – OUTDOOR LOCATION
11
HEAT PUMP AND TANK ASSEMBLY
STORAGE TANK AND HEAT PUMP MODULE
The heat pump water heater is made of two main components, the storage tank and the heat pump module. For transport and handling (weight) purposes both items are shipped separately. The water heater must not be operated until both components are installed, connected and purged of air.
Note: The heat pump flow and return pipes connecting the heat pump storage tank to the heat pump module must not exceed four (4) metres in length each and must not contain more than 4 x 90º bends each. All changes in direction of the pipe work must be made using bends. The pipe work should not contain elbows.
HEAT PUMP MODULE
The heat pump module is shipped in a box containing two hand holes to facilitate easy handling and lifting. The heat pump module must be installed against a wall and on a level slab or solid base with a minimum size of 600 mm wide x 600 mm deep. The heat pump module must be secured using the wall bracket and four feet brackets provided.
CAUTION: The heat pump module weighs approximately 46 kg. Use the hand holes provided in the sides of the packaging. Good lifting practice should be followed.
There are two flexible braided hoses provided inside the heat pump module. The flexible braided hoses are removed from the module and fixed to the outside of the heat pump module jacket using the brackets provided during the assembly procedure. The flow and return pipe work from the heat pump storage tank connects to these hoses.
A cable set housed in conduit is provided inside the heat pump module. The cable set is removed from the module and fixed to the outside of the heat pump jacket using the brackets provided during the assembly procedure. The cable set connects to the heat pump storage tank.
STORAGE TANK
The storage tank must be fully supported by a level slab or solid base. There are two water fittings located on the side of the storage tank to which the flow and return pipe work from the heat pump module is connected during the assembly procedure. The cable set from the heat pump module is also connected to the storage tank during the assembly procedure.
HEAT PUMP AND TANK ASSEMBLY
12
storage tank heat pump module
KIT
There is a kit supplied with the heat pump module (PN 290123). The components supplied in the kit are:
290123
Kit Installation Heat Pump Module Split
Qty
126574
Installation instructions heat pump module split
1
126571
Easy start guide instructions heat pump module split
1
220522
Drain hose tube ½” ID x 380 long
1
080189
Hose spring clamp – ½” ID
1
052165
Saddle clamp
1
080021
Screw phillips pan head No. 8 x 13 zinc plated black
2
108392
Bracket hose mount
1
108393
Bracket hose clamp
1
080059
Nut speed fasteners No. 6 1219
4
052160
Conduit clamp
1
080031
Screw phillips pan head No 8 x 13
7
-
Dynabolt Z passivated anchor 8 mm x 40 mm (M6)
4
108399
Bracket wall
1
-
Wall plug 8 mm x 25 mm
1
080117
Screw button head 8G x 15 x 25 zinc plated
1
088189
Tube bush fitting connector ½” M x ½” OD reliance W120
2
-
Cable tie black UV rated nylon 200 x 4.8 mm
4