Rheem 05EAUER, 05NAUER, 07EAMER, 07NAMER, 10EAMER User Manual

...
Rheem Classic®Series Super Quiet 80
A.F.U.E.†Two-Stage Downflow Gas Furnaces
FORM NO. G11-515 REV. 1
RGLQ- Series
Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kW] (U.S. & Canadian Models)
• The Rheem Classic
®
Series Super Quiet 80
2-Stage line of downflow gas furnaces is designed for installation in closets, alcoves, utility rooms, or attics. The design is certified by CSA International.
• Patented heat exchanger, constructed of aluminized steel for the maximum in corrosion resistance and thermal fatigue reliability.
• Low profile “34 inch” [864 mm] design is lighter and easier to handle, and leaves room for optional equipment.
• Left or right side gas and electric inlet connections with quick, simple change.
• Direct spark ignition.
• Integrated control board with humidifier and electronic air cleaner hookups.
• Insulated blower compartment, a two stage gas valve and a specially designed two speed draft inducer motor make it one of the quietest furnaces on the market today.
• Pre-paint galvanized steel cabinet.
• Grab-holes in doors to aid in easy door removal and replacement.
• Compatible with single or two-stage thermostat. (For optimal performance, two-stage thermostat recommended.)
• A variety of cooling coils and plenums designed to use with Rheem Classic
®
Series Super Quiet 80
2-Stage gas furnaces
are available as optional accessories.
Air
Gas Furnaces
RGLQ Series
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with
Department of Energy test procedures.
Annual Fuel Utilization Efficiency -
AFUE
THIS MODEL
97%78%
HIGH
MID
82% 88%
80.0%
ENER UIDE
Air
Table of Contents
RGLQ Series
2
TABLE OF CONTENTS
Standard & Optional Equipment ......................................................................3
Model Features/Physical Data & Specifications..................................................4
Model Number Identification ............................................................................5
Dimensional Data............................................................................................6
Blower Performance Data ................................................................................7
Accessories....................................................................................................8
Limited Warranty ............................................................................................9
Air
Standard & Optional Equipment
RGLQ Series
3
STANDARD EQUIPMENT
Completely assembled and wired; 2 speed induced draft blower; high and low pressure switches; 2 stage redundant main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; transformer; direct drive multi-speed blower motor. Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics; fused-protection (secondary).
NOTE: Furnace is not listed for use with fuels other than natural or L.P.
(propane) gas.
The complete terms of limited and other warranties are available at our sales office, or through local installer.
OPTIONAL EQUIPMENT
All models can be converted by a qualified Rheem professional or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
NOTE: For natural and L.P. (propane) gas models, direct spark ignition
is 100% lockout type.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
INTEGRATED FURNACE CONTROL
HEAT EXCHANGER
IN-SHOT BURNERS
DIRECT SPARK IGNITOR
REMOTE SENSOR
TWO-SPEED DRAFT INDUCER MOTOR
Air
Model Features/Physical Data & Specifications
RGLQ Series
4
Physical Data and Specifications
U.S. and Canadian Models
• Patented heat exchanger, constructed of aluminized steel for the maximum in corrosion resistance and thermal fatigue reliability.
• Low profile “34 inch” [864 mm] design is lighter and easier to handle, and leaves room for optional equipment.
• Left or right side gas and electric inlet connections with quick, simple change.
• Direct spark ignition.
• Integrated control board with humidifier and electronic air cleaner hookups.
• Insulated blower compartment, a two stage gas valve and a specially designed two speed draft inducer motor make it one of the quietest furnaces on the market today.
• Pre-paint galvanized steel cabinet.
• Grab-holes in doors to aid in easy door removal and replacement.
• Compatible with single or two-stage thermostat. (For optimal performance, two-stage thermostat recommended.)
• A variety of cooling coils and plenums designed to use with Rheem Classic
®
Series Super Quiet 80
2-Stage gas furnaces
are available as optional accessories.
Model Features
NOTES: All models are 115V, 60HZ, 1Ø. Gas connection size for all models is 1/2" [12.7 mm] N.P.T.
In accordance with D.O.E. test procedures.
See Conversion Kit Index for high altitude derate in U.S. applications. For Canadian applications, reference the furnace installation instructions.
[ ] Designates Metric Conversions
MODEL NUMBERS RGLQ- SERIES
High Input–BTU–BTU/Hr [kW] Heating Capacity–BTU/Hr [kW] Low Input–BTU/Hr [kW] 35,000 [10] 52,500 [15] Heating Capacity–BTU/Hr [kW] 28,000 [8] 41,600 [12] Heating–Ext. Static Pressure [kPa] .10 [.025] .12 [.029] .15 [.037] .15 [.037] .20 [.05] .20 [.05]
Blower (D x W) [mm]
Motor H.P.–[W] Speeds–Type
Motor Full Load Amps 6.8 7.1 Heating Speed–High Fire MED-LOW MED-HIGH Heating Speed–Low Fire LOW MED-LOW LOW LOW LOW LOW Cooling Speed HIGH HIGH Cooling CFM @ .5" [kPa] E.S.P.
(Nominal) [L/s] Max. E.S.P. (In. W.C.) [kPa] 0.5 [.12] 0.5 [.12] Temperature Rise Range °F [°C]
High Input Temperature Rise Range °F [°C]
Low Input Max. Outlet Air Temp. °F
[°C] Standard Filter–In.
[mm] Approx. Shipping Weight (Lbs.)
[kg] AFUE
05EAUER 05NAUER
50,000 [15] 75,000 [22] 40,360 [12] 61,020 [18]
11 x 6
[279 x 152]
1
/2 [373]
4-PSC
1200 [566]
25-55
[13.9-30.6]
20-50
[11.1-27.8]
155
[68.3]
(1) 14 x 20
[356 x 508]
85
[39]
80.0% 80.0%
07EAMER
07NAMER
11 x 7
[279 x 178]
1
/2 [373]
4-PSC
1200 [566]
35-65
[19.4-36.1]
30-60
[16.7-33.0]
165
[78.3]
(2) 12 x 20
[306 x 508]
105 [48]
10EAMER 10NAMER
100,000 [29] 100,000 [29] 125,000 [37]
81,600 [24] 81,040 [24] 101,750 [29] 70,000 [20] 70,000 [20] 87,500 [25] 56,000 [16] 56,000 [16] 70,000 [20]
11 x 7
[279 x 178]
1
/2 [373]
4-PSC
7.1 9.5 9.5
MED-HIGH MED-HIGH MED-HIGH
HIGH HIGH HIGH 1200
[566]
0.5 [.12] 0.5 [.12] 0.5 [.12] 45-75
[25.0-41.7]
20-50
[11.1-27.8]
180
[82.2]
(2) 12 x 20
[306 x 508]
115 [52]
80.0% 80.0% 80.0%
10EBRJR 10NBRJR
11 x 10
[279 x 254]
3
/4 [559] 4-PSC
2000
[944]
30-60
[16.7-33.3]
35-65
[19.4-36.1]
180
[82.2]
(2) 14 x 20
[356 x 508]
120 [54]
12EARJR 12NARJR
11 x 10
[279 x 254]
3
/4 [559]
4-PSC
2000 [944]
35-65
[19.4-36.1]
25-55
[13.9-30.6]
180
[82.2]
(2) 14 x 20
[356 x 508]
140 [63]
15EARJR 15NARJR
150,000 [44] 121,550 [35] 105,000 [30]
84,000 [24]
11 x 10
[279 x 254]
3
/4 [559]
4-PSC
9.5
MED-HIGH
HIGH 2000
[944]
0.5 [.12] 50-80
[27.8-44.4]
30-60
[16.7-33.3]
190
[87.7]
(2) 14 x 20
[356 x 508]
150
[68]
80.0%
Air
Model Number Identification
RGLQ Series
5
Model Number Identification—Downflow Models
RG L Q 07E A M E R
Rheem Gas Downflow Design Heating Input Designation Variations Blower Heating & Cooling Fuel Type
U = 11 x 6
[279 x 152 mm]
M = 11 x 7
[279 x 178 mm]
R = 11 x 10
[279 x 254 mm]
E = 1100-1330 CFM
[519-628 L/s]
J = 1800-2075 CFM
[850-979 L/s]
Furnace Series
Electric Ignition
05E 07E 10E 12E 15E
A = Std.
Cabinet
B = Wide
Cabinet
Designation Designation R = Natural Gas,
U.S. and Canadian Standard Furnace
Electric
Ignition–
NO
x
Models
05N 07N 10N 12N 15N
Input
BTU/HR
50,000 [15 kW]
75,000 [22 kW] 100,000 [29 kW] 125,000 [37 kW] 150,000 [44 kW]
[ ] Designates Metric Conversions
Air
Dimensional Data
RGLQ Series
6
Downflow Dimensions
NOTES: May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
May be 0" [0 mm] with type B vent.May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes.
[ ] Designates Metric Conversions
Dimensions and Clearance to Combustible Material (inches) [mm]
MODEL
RGLQ-
05
07 10 (A) 171/2 [445] 1611/32 [415] 121/8 [308] 10 (B)
12 241/2 [622] 2311/32 [593] 155/8 [397]
15 241/2 [622] 2311/32 [593] 155/8 [397]
A B C D E
14 [356] 1227/32 [326] 103/8 [264] 171/2 [445] 1611/32 [415] 121/8 [308]
21 [533] 1927/32 [504] 137/8 [352]
LEFT SIDE
131/8 [333]
165/8 [422]
165/8 [422] 0
201/8 [511]
235/8 [600] 0 0 0 1 [25] 3 [76]
235/8 [600] 0 0 0 1 [25] 3 [76]
0 0
0
RIGHT
SIDE
4 [102] 3 [76] 3 [76]
0
REDUCED CLEARANCES (IN.) [mm]
BACK TOP FRONT VENT
0 1 [25] 3 [76]
0 1 [25] 3 [76]
0 1 [25] 3 [76] 0 1 [25] 3 [76]
6 [152] 6 [152] 6 [152] 6 [152] 6 [152] 6 [152]
SHIP. WGTS.
(LBS.) [kg]
85 [38.6] 105 [47.6] 115 [52.2] 120 [54.4] 140 [63.5] 150 [68]
NOTES: Not to be used as a low stage heating speed.
Data compiled with factory filters installed. See Form Number C11-211 for “N” Coil Data. Factory rated to 0.5" W.C. *E = Standard
*N = NOx Models
[ ] Designates Metric Conversions
Air
Blower Performance Data
RGLQ Series
7
Blower Performance Data—Downflow Models
MODEL
NUMBER
RGLQ-
SERIES
05*AUER
07*AMER
10*AMER
10*BRJR
12*ARJR
15*ARJR
BLOWER
SIZE
[mm]
11 x 6
[279 x 152]
11 x 7
[279 x 178]
11 x 7
[279 x 178]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
MOTOR
H.P.
[W]
1/2
[373]
1/2
[373]
1/2
[373]
3/4
[559]
3/4
[559]
3/4
[559]
BLOWER
SPEED
LOW
MED-LO
MED-HI
HIGH
LOW
MED-LO
MED-HI
HIGH LOW 895 [422] 874 [412] 852 [402] 825 [389] 798 [376]
MED-LO
MED-HI
HIGH LOW
MED-LO
MED-HI
HIGH LOW
MED-LO
MED-HI
HIGH LOW
MED-LO
MED-HI
HIGH
.1 [.02] .2 [.05] .3 [.07] .4 [.10] .5 [.12] .6 [.15] .7 [.17]
655 [309] 975 [460] 180 [557]
1335 [630]
910 [429] 1074 [507] 1229 [580] 1409 [665]
1052 [496] 1238 [584] 1383 [652]
1374 [648] 1709 [806] 2132 [1006] 2362 [1114]
1315 [620] 1618 [763] 2065 [974] 2275 [1074]
1300 [614] 1675 [791] 2105 [993]
EXTERNAL STATIC PRESSURE INCHES [kPa] WATER COLUMN
630 [297]
943 [445] 1140 [538] 1290 [608]
887 [418] 1054 [497] 1207 [569] 1385 [653]
1033 [487] 1217 [574] 1366 [644]
1356 [640] 1686 [795] 2085 [984] 2300 [1085]
1292 [609] 1597 [753] 2025 [956] 2219 [1047]
1280 [604] 1650 [779] 2075 [979] 2340 [1104]
CFM [L/s] AIR DELIVERY
600 [283]
915 [432] 1105 [521] 1250 [590]
863 [407] 1034 [488] 1184 [558] 1361 [642]
1013 [478] 1196 [564] 1348 [636]
1339 [632] 1663 [784] 2038 [961] 2237 [1055]
1269 [599] 1576 [743] 1984 [936] 2163 [1021]
1230 [580] 1620 [765] 2035 [960] 2290 [1081]
565 [266]
886 [418] 1067 [503] 1202 [567]
839 [396] 1007 [475] 1159 [547] 1329 [627]
991 [467] 1169 [551] 1317 [621]
1323 [624] 1635 [771] 1988 [938] 2173 [1025]
1250 [590] 1552 [732] 1938 [915] 2103 [992]
1205 [569] 1570 [741] 1990 [939] 2215 [1045]
532 [251]
852 [402] 1027 [484] 1157 [546]
814 [384]
979 [462] 1134 [535] 1297 [612]
968 [457] 1143 [539] 1286 [607]
1286 [607] 1607 [758] 1937 [914] 2108 [994]
1231 [581] 1528 [721] 1891 [892] 2042 [964]
1170 [552] 1545 [729] 1955 [923] 2145 [1012]
500 [236] 813 [383] 980 [462]
1110 [524]
776 [366]
944 [455] 1099 [518] 1260 [594]
766 [362] 734 [346]
930 [439] 1094 [516] 1245 [587]
1249 [589] 1562 [737] 1882 [888] 2036 [960]
1194 [563] 1486 [701] 1824 [861] 1982 [935]
1115 [526] 1485 [701] 1900 [897] 2080 [982]
467 [220] 770 [363] 924 [436]
1060 [500]
738 [348]
908 [428] 1063 [501] 1223 [577]
891 [420] 1044 [492] 1203 [567]
1212 [572] 1516 [715] 1827 [862] 1964 [926]
1157 [546] 1443 [681] 1756 [829] 1921 [907]
1030 [486] 1425 [673] 1815 [857] 1995 [942]
Air
Accessories
RGLQ Series
8
DOWNFLOW ACCESSORIES
DOWNFLOW WARNING: Unit design is certified for installation on non­combustible floor. A special factory supplied combustible floor sub­base is required when installing on a combustible floor. Failure to install the sub-base may result in fire, property damage and personal injury.
COMBUSTIBLE FLOOR BASE DIMENSIONS
RXPF-F01 and F02
FOSSIL FUEL KIT—is for use with Rheem Heat Pumps and
Classic
Series warm air furnaces. RXPF-F02 meets TVA requirements.
FOR HIGH ALTITUDES:
HIGH ALTITUDE CONVERSION:
See Installation Instructions for more high altitude information. CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines
when converting furnaces for high altitudes.
RXGF-CC*
FILTER RACK—Downflow top
return mount. NOTE: Filter racks are shipped
without filters.
*Filters available through PROSTOCK
®
.
[ ] Designates Metric Conversions
COMBUSTIBLE
FLOOR BASE
RXGC-B14 RXGC-B17 18 [457] 163/4 RXGC-B21 211/2 [546] 201/4 [514]RGLQ-10(-)B RXGC-B24
USE WITH
FURNACE SIZES
RGLQ-07, RGLQ-10(-)A
RGLQ-12, RGLQ-15
A
IN. [mm]BIN. [mm]
2 [368]
141/
25 [635] 233/4 [603]
131/
4 [337]RGLQ-05
[425]
C
IN. [mm]
4 [286]
111/ 143/4 181/4 [464] 213/4 [552]
[451]
FURNACE
WIDTH
IN. [mm]
141/2 [356] 45 [13.19] & 50 [14.65] 14 [356] x 20 [508] 1 171/2 [445] 67 [19.64], 75 [21.98] & 100 [29.31] 12 [305] x 20 [508] 1 211/2 [533] 100 [29.31] 12 [305] x 20 [508] 2 241/2 [622]
125 [36.63] & 150 [44.0] 14 [356] x 20 [508] 2
DOWNFLOW FILTER SIZES
INPUT
BTUH [kW]
SIZE
IN. [mm]
QUANTITY
Air
Limited Warranty
RGLQ Series
9
GENERAL TERMS OF LIMITED WARRANTY*
Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
*For complete details of the Limited and Conditional Warranties,
including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
Gas Heat Exchanger Limited Warranty ......Twenty (20) Years
Conditional Parts* (Registration Required) ......Ten (10) Years
Air
Notes
RGLQ Series
10
Air
Notes
RGLQ Series
11
The new degree of comfort.
Rheem Heating, Cooling & Water Heating • P.O. Box 17010
Fort Smith, Arkansas 72917 • www.rheem.com
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
PRINTED IN U.S.A 10/13 QG FORM NO. G11-515 REV. 1
Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Brampton, Ontario • L6Y 0P5
Loading...