Rheem 05EAUER, 05NAUER, 07EAMER, 07NAMER, 07EAMGR User Manual

...
Rheem Classic®Series Two-Stage Upflow/Horizontal Gas Furnaces
FORM NO. G11-514 REV. 1
RGPQ- Series
80% A.F.U.E.† Models with Input Rates from 45-105 kBTU (U.S. & Canadian Models)
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with
Department of Energy test procedures.
• The Rheem Classic
®
Series 2-Stage line of upflow/horizontal gas furnaces are designed for utility rooms, closets, alcoves, or attics. Because of the low-profile 34 inch [864 mm]
height, the upflow model can also be used to satisfy most applications that traditionally call for a horizontal furnace.
• The design is certified by CSA International.
• Patented heat exchanger, constructed of aluminized steel for the maximum in corrosion resistance and thermal fatigue reliability.
• Low profile “34 inch” design is lighter and easier to handle, and leaves room for optional equipment.
• Convertible from upflow to horizontal left or right without field conversion.
• Left or right side gas and electric inlet connections with quick, simple change.
• Direct spark ignition models equipped with remote sense and feature an integrated board with humidifier and electronic air cleaner hookups.
• Insulated blower compartment, a two stage gas valve and a specially designed two speed draft inducer motor make it one of the quietest furnaces on the market today.
• Pre-paint galvanized steel cabinet.
• Molded permanent filter.
• Grab-holes in doors to aid in easy door removal and replacement.
• Compatible with single or two-stage thermostat. (For optimal performance two-stage thermostat recommended.)
• A variety of cooling coils and plenums designed to use with Rheem Classic
®
Series 2-Stage gas furnaces are available as
optional accessories.
• Furnaces can be installed in an upflow position or laid on either side in a horizontal position. Field conversion not required.
Air
Gas Furnaces
RGPQ Series
ENER UIDE
Annual Fuel Utilization Efficiency -
THIS MODEL
80.0%
MID
82% 88%
AFUE
HIGH
97%78%
Air
Table of Contents
RGPQ Series
2
TABLE OF CONTENTS
Standard & Optional Equipment ......................................................................3
Model Features/Physical Data & Specifications..................................................4
Model Number Identification ............................................................................5
Dimensional Data ........................................................................................6-7
Blower Performance Data ................................................................................8
Accessories....................................................................................................9
Limited Warranty ..........................................................................................10
Air
Standard & Optional Equipment
RGPQ Series
3
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
STANDARD EQUIPMENT
Completely assembled and wired; 2 speed draft inducer; high and low pressure switches; redundant 2 stage main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; transformer; direct drive multi-speed blower motor. Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics; Twinning options; fused-protection (secondary).
DIRECT SPARK IGNITOR
IN-SHOT BURNERS
INTEGRATED FURNACE CONTROL
HEAT EXCHANGER
REMOTE SENSOR
TWO-SPEED DRAFT INDUCER MOTOR
OPTIONAL EQUIPMENT
Side filter frame assembly. Return air cabinet for all sizes. NOTE: Furnace is not listed for use with fuels other than natural
or L.P. (propane) gas.
The complete terms of limited and other warranties are available at our sales office, or through local installer.
All models can be converted by a qualified local service professional to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
Air
Model Features/Physical Data & Specifications
RGPQ Series
4
• Patented heat exchanger, constructed of aluminized steel for the maximum in corrosion resistance and thermal fatigue reliability.
• Low profile “34 inch” design is lighter and easier to handle, and leaves room for optional equipment.
• Convertible from upflow to horizontal left or right without field conversion.
• Left or right side gas and electric inlet connections with quick, simple change.
• Direct spark ignition models equipped with remote sense and feature an integrated board with humidifier and electronic air cleaner hookups.
• Insulated blower compartment, a two stage gas valve and a specially designed two speed draft inducer motor make it one of the quietest furnaces on the market today.
• Pre-paint galvanized steel cabinet.
• Molded permanent filter.
• Grab-holes in doors to aid in easy door removal and replacement.
• Compatible with single or two-stage thermostat. (For optimal performance two-stage thermostat recommended.)
• A variety of cooling coils and plenums designed to use with Rheem Classic
®
Series 2-Stage gas furnaces are available as
optional accessories.
Model Features
Physical Data and Specifications—Downflow Models
U.S. and Canadian Models
NOTES:All models are 115V, 60HZ, 1Ø. Gas connection size for all models is 1/2" [12.7 mm] N.P.T.
In accordance with D.O.E. test procedures.See Conversion Kit Index Form for high altitude derate in U.S. applications. For Canadian applications, reference the furnace installation instructions.
[ ] Designates Metric Conversions
MODEL NUMBERS
RGPQ- SERIES
High Inpu Heating Capa Low Input–BTU/Hr [kW] 35,000 [10] 52,500 [15] Heating Capacity–BTU/Hr [kW] 28,000 [8] 41,600 [12] Heating–Ext. Static Pressure [kPa] .10 [.025] .12 [.029] .12 [.029] .15 [.037] .15 [.037] .20 [.05] .20 [.05]
Blower (D x W) [mm]
Motor H.P.–[W] Speeds–Type
Motor Full Load Amps 7.1 7.1 Heating Speed–High Fire MED-LOW MED-HIGH Heating Speed–Low Fire LOW MED-LOW LOW LOW LOW LOW LOW Cooling Speed HIGH HIGH Cooling CFM @ .5" [kPa] E.S.P.
(Nominal) [L/s] Max. E.S.P. (In. W.C.) [kPa] 0.5 [.12] 0.5 [.12] Temperature Rise Range °F
High Input [°C] Temperature Rise Range °F
Low Input [°C] Max. Outlet Air Temp. °F
[°C] Standard Filter–In.
[mm] Approx. Shipping Weight (Lbs.)
[kg] Return Air Cabinets (Opt.) RXGR-
Filter Size–In. [mm]
AFUE
t–BTU–B
city–BTU
TU/Hr [kW]
/Hr [kW]
05EAUER 05NAUER
50,000 [15] 75,000 [22] 40,900 [12] 61,280 [18]
11 x 6
[279 x 152]
1
/2 [373]
4-PSC
1200
[566]
25-55
[13.9-30.6]
20-50
[11.1-27.8]
155
[68.3]
153/4 x 25
[400 x 635]
85
[39]
C14B
(2) 12 x 16
[305 x 406]
80.0% 80.0%
07EAMER
07NAMER
11 x 7
[279 x 178]
1
/2 [373]
4-PSC
1200
[566]
30-60
[16.7-33.3]
25-55
[13.9-30.6]
165
[73.9]
153/4 x 25
[400 x 635]
105 [48]
C17B
(2) 12 x 16
[305 x 406]
07EAMGR 07NAMGR
75,000 [22] 100,000 [29] 100,000 [29] 125,000 [37] 61,410 [18] 81,470 [23] 81,340 [23] 101,660 [29] 52,500 [15] 70,000 [20] 70,000 [20] 87,500 [25] 41,600 [12] 56,000 [16] 56,000 [16] 70,080 [20]
11 x 7
[279 x 178]
3
/4 [559]
4-PSC
9.5 7.1 9.5 9.5
MED-LOW MED-HIGH MED-HIGH MED-HIGH
MED-HIGH HIGH HIGH HIGH
1600
[755]
0.5 [.12] 0.5 [.12] 0.5 [.12] 0.5 [.12] 25-55
[13.9-30.6]
15-45
[8.3-25.0]
155
[68.3]
153/4 x 25
[400 x 635]
105 [48]
C17B
(2) 12 x 16
[305 x 406]
80.0% 80.0% 80.0% 80.0%
10EAMER 10NAMER
11 x 7
[279 x 178]
1
/2 [373]
4-PSC
1200
[566]
45-75
[25-41.7]
35-65
[19.4-36.1]
190
[87.7]
153/4 x 25
[400 x 635]
115
[52]
C17B
(2) 12 x 16
[305 x 406]
10EBRJR 10NBRJR
11 x 10
[279 x 254]
3
/4 [559]
4-PSC
2000
[944]
30-60
[16.7-33.3]
25-55
[13.9-30.6]
170
[76.6]
191/4 x 25
[489 x 635]
120 [54]
C21B
(2) 20 x 16
[508 x 406]
12EARJR 12NARJR
11 x 10
[279 x 254]
3
/4 [559]
4-PSC
2000
[944]
35-65
[19.4-36.1]
30-60
[16.7-33.3]
180
[82.2]
223/4 x 25
[578 x 635]
140 [63]
C24B
(2) 24 x 16
[610 x 406]
15EARJR 15NARJR
150,000 [44] 121,920 [35] 105,000 [30]
84,000 [24]
11 x 10
[279 x 254]
3
/4 [559]
4-PSC
9.5
MED-HIGH
HIGH 2000
[944]
0.5 [.12] 50-80
[27.8-44.4]
40-70
[22.2-38.9]
190
[87.7]
223/4 x 25
[578 x 635]
150 [68]
C24B
(2) 24 x 16
[610 x 406]
80.0%
Air
Model Number Identification
RGPQ Series
5
Model Number Identification—Upflow Models
R G P Q
07E A M E R
Rheem Gas Upflow/ Horizontal Heating Input Designation Variations Blower Heating & Cooling Fuel Type
Furnace
Horizontal
Series
Electric Ignition
05E 07E 10E 12E 15E
NOx
Models
05N 07N 10N 12N 15N
Input
BTU/HR
50,000 [15 kW]
75,000 [22 kW] 100,000 [29 kW] 125,000 [37 kW] 150,000 [44 kW]
A = Std.
Cabinet
B = Wide
Cabinet
Designation
Designation
R = Natural Gas,
U.S. and Canadian Standard Furnace
U = 11 x 6
[279 x 152 mm]
M = 11 x 7
[279 x 178 mm]
R = 11 x 10
[279 x 254 mm]
E = 1100-1300 CFM
[519-614 L/s]
J = 1900-2100 CFM
[897-991 L/s]
G = 1500-1700 CFM
[708-802 L/s]
[ ] Designates Metric Conversions
Air
Dimensional Data
RGPQ Series
6
Upflow Dimensions and Clearance to Combustible Material (inches) [mm]
MODEL
RGPQ-
A B C D E
REDUCED CLEARANCES (IN.) [mm]
05
14 [356] 1227/32 [326] 105/8 [270]
111/2 [292]
0
4 [102]
0 1 [25] 3 [76]
6 [152]
LEFT SIDE
RIGHT
SIDE
BACK TOP FRONT VENT
SHIP. WGTS.
(LBS.) [kg]
85 [38.6]
07
171/2 [445] 1611/32 [415] 123/8 [314]
15 [381]
0
3 [76]
0 1 [25] 3 [76]
6 [152]
105 [47.6]
10 (A) 171/2 [445] 1611/32 [415] 123/8 [314]
15 [381] 0
3 [76]
0 1 [25] 3 [76]
6 [152]
115 [52.2]
10 (B)
21 [533] 1927/32 [504] 141/8 [359]
181/2 [470]
0
0
0 1 [25] 3 [76]
6 [152]
120 [54.4]
12 241/2 [622] 2311/32 [593] 157/8 [403]
22 [559] 0 0 0 1 [25] 3 [76]
6 [152]
140 [63.5]
15 241/2 [622] 2311/32 [593] 157/8 [403]
22 [559] 0 0 0 1 [25] 3 [76]
6 [152]
150 [68]
F
17/8 [48]
21/2 [64]
21/2 [64]
21/2 [64] 21/2 [64]
21/2 [64]
NOTES: May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
May be 0" [0 mm] with type B vent.May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes.
[ ] Designates Metric Conversions
Upflow Dimensions
Air
Dimensional Data
RGPQ Series
7
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED FOR INSTALLATION
ON ITS BACK, WITH ACCESS DOORS
FACING UPWARDS.
Horizontal Dimensions and Clearance to Combustible Material (inches) [mm]
MODEL
RGPQ-
A B C D E
REDUCED CLEARANCES (IN.) [mm]
05
14 [356] 1227/32 [326] 105/8 [270]
111/2 [292]
0
4 [102]
0 1 [25] 3 [76]
6 [152]
LEFT SIDE
RIGHT
SIDE
BACK TOP FRONT VENT
SHIP. WGTS.
(LBS.) [kg]
85 [38.6]
07
171/2 [445] 1611/32 [415] 123/8 [314]
15 [381]
0
3 [76]
0 1 [25] 3 [76]
6 [152]
105 [47.6]
10 (A) 171/2 [445] 1611/32 [415] 123/8 [314]
15 [381] 0
3 [76]
0 1 [25] 3 [76]
6 [152]
115 [52.2]
10 (B)
21 [533] 1927/32 [504] 141/8 [359]
181/2 [470]
0
0
0 1 [25] 3 [76]
6 [152]
120 [54.4]
12 241/2 [622] 2311/32 [593] 157/8 [403]
22 [559] 0 0 0 1 [25] 3 [76]
6 [152]
140 [63.5]
15 241/2 [622] 2311/32 [593] 157/8 [403]
22 [559] 0 0 0 1 [25] 3 [76]
6 [152]
150 [68]
F
17/8 [48]
21/2 [64]
21/2 [64]
21/2 [64] 21/2 [64]
21/2 [64]
NOTES: May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
May be 0" [0 mm] with type B vent.May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes.
[ ] Designates Metric Conversions
Horizontal Dimensions
Air
Blower Performance Data
RGPQ Series
8
Blower Performance Data
NOTES: Data compiled with factory filters installed.
Factory Rated to 0.5" W.C. *E = Standard
*N = NOx Models
[ ] Designates Metric Conversions
MODEL
NUMBER
RGPQ-
SERIES
05*AUER
07*AMER
07*AMGR
10EAMER
10*AMER
10*BRJR
12*ARJR
15*ARJR
BLOWER
SIZE
[mm]
11 x 6
[279 x 152]
11 x 7
[279 x 178]
11 x 7
[279 x 178]
11 x 7
[279 x 178]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
MOTOR
H.P.
[W]
1/2
[373]
1/2
[373]
3/4
[559]
1/2
[373]
3/4
[559]
3/4
[559]
3/4
[559]
BLOWER
SPEED
LOW
MED-LO
MED-HI
HIGH LOW
MED-LO
MED-HI
HIGH LOW
MED-LO
MED-HI
HIGH
LOW 925 [437] 890 [420] 865 [408] 835 [394] 810 [382]
MED-LO
MED-HI
HIGH LOW
MED-LO
MED-HI
HIGH LOW
MED-LO
MED-HI
HIGH LOW
MED-LO
MED-HI
HIGH
.1 [.02] .2 [.05] .3 [.07] .4 [.10] .5 [.12] .6 [.15] .7 [.17]
675 [319]
950 [448] 1115 [526] 1270 [599]
921 [435] 1093 [563] 1241 [586] 1393 [657]
1245 [588] 1555 [734] 1810 [854] 2050 [967]
1050 [496] 1220 [576] 1360 [641]
1295 [611] 1645 [776] 2045 [965] 2320 [1095]
1280 [604] 1645 [776] 2050 [967] 2365 [1116]
1270 [599] 1620 [765] 2010 [949] 2340 [1104]
EXTERNAL STATIC PRESSURE INCHES [kPa] WATER COLUMN
655 [309]
930 [439] 1090 [514] 1250 [590]
897 [423] 1066 [503] 1212 [572] 1359 [642]
1220 [576] 1515 [715] 1755 [828] 1985 [937]
1040 [491] 1195 [564] 1327 [626]
1275 [602] 1615 [762] 2000 [944] 2260 [1067]
1275 [602] 1635 [772] 2015 [951] 2310 [1090]
1250 [590] 1595 [753] 1985 [937] 2275 [1074]
1070 [505] 1225 [578]
1039 [490] 1183 [558] 1326 [626]
1195 [564] 1475 [696] 1705 [805] 1915 [904]
1030 [486] 1160 [547] 1295 [611]
1250 [590] 1580 [746] 1955 [923] 2200 [1038]
1265 [597] 1615 [762] 1960 [925] 2250 [1062]
1220 [576] 1570 [741] 1960 [925] 2215 [1045]
CFM [L/s] AIR DELIVERY
635 [300] 905 [427]
872 [411]
610 [288]
880 [415] 1040 [491] 1200 [566]
845 [399] 1008 [476] 1150 [543] 1293 [610]
1165 [550] 1435 [677] 1645 [776] 1845 [871]
990 [467] 1140 [538] 1263 [596]
1225 [578] 1550 [732] 1905 [899] 2130 [1005]
1245 [588] 1590 [750] 1935 [913] 2185 [1031]
1195 [564] 1545 [729] 1915 [904] 2145 [1012]
585 [276]
860 [406] 1015 [479] 1165 [550]
818 [386]
977 [461] 1118 [528] 1259 [594]
1135 [536] 1395 [658] 1585 [748] 1785 [842]
960 [453] 1105 [522] 1231 [581]
1195 [564] 1510 [713] 1845 [871] 2060 [972]
1215 [573] 1560 [736] 1885 [890] 2115 [998]
1165 [550] 1515 [715] 1850 [873] 2080 [982]
555 [262] 830 [392] 985 [465]
1130 [533]
795 [375]
941 [444] 1076 [508] 1214 [573]
1105 [522] 1350 [637] 1530 [722] 1715 [809]
775 [366] 745 [352]
920 [434] 1065 [503] 1179 [556]
1165 [550] 1465 [691] 1785 [842] 1985 [937]
1185 [559] 1520 [717] 1835 [866] 2035 [960]
1135 [536] 1480 [698] 1800 [850] 2010 [949]
520 [245] 800 [378] 945 [446]
1085 [512]
746 [352]
905 [427] 1033 [487] 1169 [552]
1065 [503] 1300 [614] 1470 [694] 1655 [781]
890 [420] 1020 [481] 1128 [532]
1135 [536] 1425 [673] 1720 [812] 1910 [901]
1145 [540] 1470 [694] 1775 [838] 1950 [920]
1105 [522] 1440 [680] 1730 [816] 1940 [916]
Air
Accessories
RGPQ Series
9
EXTERNAL BOTTOM FILTER RACK: RXGF-CB EXTERNAL SIDE RETURN FILTER RACK: RXGF-CA
†Filter racks are shipped without filters.
Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter.
*Designates “E” or “N”.
OPTION CODE FOR HIGH ALTITUDE: 278
CANADA-For high altitude derate procedure, refer to furnace Installation Instructions
RXPF-F01 and F02
FOSSIL FUEL KIT—is for use with Rheem Heat Pumps and
warm air furnaces. RXPF-F02 meets TVA requirements.
ACCESSORY RETURN AIR CABINETS
Return Air Cabinets may be installed on either side application except RXGR-C24B (side application must be on side opposite gas and electrical connections).
THE RXGR-C24B MUST ONLY BE INSTALLED ON THE SIDE OPPOSITE THE GAS AND ELECTRICAL CONNECTIONS.
WARNING: IMPORTANT NOTICE
A SOLID METAL BASE PLATE (SEE TABLE) MUST BE IN PLACE WHEN THE FURNACE IS INSTALLED WITH SIDE AIR RETURN DUCTS. FAILURE TO INSTALL A BASE PLATE COULD CAUSE PRODUCTS OF COMBUSTION TO BE CIRCULATED INTO THE LIVING SPACE AND CREATE POTENTIALLY HAZARDOUS CONDITIONS.
FURNACE BASE
WIDTH
SOLID BOTTOM BASE
PLATE SIZE
IN. [mm]
KIT NO. PLATE NO.
IN. [mm]
14 [356] RXGB-D14 AE-61874-01 11
5
/8 x 239/16 [295 x 598]
17
1
/2 [445] RXGB-D17 AE-61874-02 151/8 x 239/16 [384 x 598]
21 [533] RXGB-D21 AE-61874-03 18
5
/8 x 239/16 [473 x 598]
24
1
/2 [622] RXGB-D24 AE-61874-04 255/8 x 239/16 [651 x 598]
FILTER RACK FILTER SIZES† INCHES [mm]
10*BRJ
MODEL
RGPQ-
RXGF-CA
(SIDE)
05, 07, 10*A
153/
4 x 25
[400 x 635]
153/4 x 25
[400 x 635]
12, 15
153/4 x 25
[400 x 635]
[ ] Designates Metric Conversions
RETURN AIR CABINETS
A
IN. [mm]
FILTER SIZE
RXGR-C14B 14 [356] (2) 12 x 16 [305 x 406] RXGR-C17B RXGR-C21B RXGR-C24B
2 [445] (2) 12 x 16 [305 x 406]
171/ 21 [533]
[622]
241/2
(2) 20 x 16 [508 x 406] (2) 24 x 16 [610 x 406]
IN. [mm]
Air
Limited Warranty
RGPQ Series
10
GENERAL TERMS OF LIMITED WARRANTY*
Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
*For complete details of the Limited and Conditional Warranties, including
applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
Gas Heat Exchanger Limited Warranty ........Limited Lifetime
Conditional Parts* (Registration Required) ......Ten (10) Years
Air
Notes
RGPQ Series
11
The new degree of comfort.
Rheem Heating, Cooling & Water Heating • P.O. Box 17010
Fort Smith, Arkansas 72917 • www.rheem.com
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
PRINTED IN U.S.A 10/13 QG FORM NO. G11-514 REV. 1
Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Brampton, Ontario • L6Y 0P5
Loading...