Rheem 025JEC Submittal Sheet

SUBMITTAL COVER SHEET
Quantity
Unit Designation
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES: NOTES:
PRINTED IN U.S.A 01/12 QG FORM NO. M11-1640
PROJECT NAME
LOCATION
ARCHITECT
ENGINEER
CONTRACTOR
SUBMITTED BY DATE
UNIT SUMMARY
FORM NO. X33-1412
Supersedes Form No. X66-1317 Rev. 1
SUBMITTAL SHEET FOR (-)ARL- JEC 2 thru 5 TONS [7.03 thru 17.6 kW] , 16 SEER HIGH EFFICIENCY TWO-STAGE COOLING CONDENSING UNITS
UNIT DATA
COOLING PERFORMANCE
EFFICIENCY ................................
_______
SEER
TOTAL CAPACITY*..................
_______
MBH [kW]
SENSIBLE CAPACITY*............
_______
MBH [kW]
OUTDOOR DESIGN TEMP. ....
_______
°F [°C] DB
TEMP. OF AIR ENTERING
EVAPORATOR COIL............
_______
°F [°C] DB
_______
°F [°C] WB
POWER INPUT REQUIREMENT ........
_______
kW
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT......................................
_______
IWG
BLOWER SPEED ..........................
_______
RPM
POWER OUTPUT REQUIREMENT ..
_______
BHP
MOTOR RATING ........................
_______
HP [W]
POWER INPUT REQUIREMENT ........
_______
kW
ELECTRICAL DATA
POWER SUPPLY......................
____________ Hz
TOTAL UNIT AMPACITY................
_______
AMPS
MINIMUM WIRE SIZE ....................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ..........
_______
AMPS
CLEARANCES
ACCESS SIDE 24" [609.6 mm]
AIR INLETS 12" [304.8 mm]
ABOVE UNIT 60" [1524 mm]
Equipped with the
Comfort Control2System
• Serial communication enabled
• Increased system reliability and efficiency
• 32+ on-board diagnostic and operating codes
Active Protection
with homeowner “Call for Service” alert
• Exclusive Design with dual 7-segment LED display
“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with
appropriate coil components to meet ENERGY STAR criteria. Ask your Contractor for details or visit www.energystar.gov.”
FEATURES FOR (-)ARL- JEC SERIES
TWO-STAGE CONDENSING UNITS
2 THRU 5 TON [7.03 THRU 17.6 kW]
• Industry’s lowest profile design: 33" maximum height.
• Features a 10-year conditional unit replacement warranty and 10-year parts warranty when properly installed with a new Rheem air handler or Rheem indoor coil with a Rheem gas furnace. See product warranty card for additional information.
• Reliable Two-Stage operation for precise temperature control with On-Demand dehumidification feature. When matched with ECM gas furnace or air-handler, the system adjusts airflow to help control humidity for unsurpassed comfort in the cooling mode.
• All controls are accessible by removing one service panel. Removable top grille provides access to the condenser fan motor and condenser coil.
• Attractive, louvered wrap-around jacket protects the coil from yard hazards and weather extremes. Top grille is steel reinforced for extra strength. Cabinet is powder painted for all weather protection.
• For quiet operation and improved efficiency, all models feature highly optimized fan & motor combinations.
• All models meet or exceed a 1000-hour salt spray test per ASTM B117 Standard Practice for Operating Salt Spray Testing Apparatus.
ACCESSORIES
Low Ambient Control (Model No. RXAD-A08) ......................
Compressor Crankcase Heater ........................................
Thermostat (See Specification Sheet for details) ................
JOB NAME LOCATION
CONTRACTOR ORDER NO.
ENGINEER UNIT MODEL NO.
SUBMITTED FOR APPROVAL RECORD COIL MODEL NO.
DATE AIR HANDLER MODEL NO.