Rheem 024JEC, 036JEC Submittal Sheet

PROJECT NAME ______________________________________________________________________________
LOCATION __________________________________________________________________________________
ARCHITECT__________________________________________________________________________________
ENGINEER __________________________________________________________________________________
CONTRACTOR ______________________________________________________________________________
SUBMITTED BY ______________________________ DATE ________________________________________
UNIT SUMMARY
SUBMITTAL COVER SHEET
Quantity
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Air Lvg. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES: NOTES:
PRINTED IN U.S.A. 10-06 DC FORM NO. X11-1123 REV. 2
Supersedes Form No. X11-1123 Rev. 1
[ ] Designates Metric Conversions
FORM NO. X33-1268
Supersedes Form No. X33-1240
JOB NAME LOCATION
CONTRACTOR ORDER NO.
ENGINEER SUBMITTED FOR APPROVAL RECORD
DATE
MODEL NO.
AIR HANDLER MODEL NO.
INDOOR COIL MODEL NO.
DIMENSIONS
UNIT DATA
COOLING PERFORMANCE
EFFICIENCY ........................
_______
SEER/EER
TOTAL CAPACITY*..................
_______
MBH [kW]
SENSIBLE CAPACITY*............
_______
MBH [kW]
OUTDOOR DESIGN TEMP. ....
_______
°F [°C] DB
TEMP. OF AIR ENTERING
EVAPORATOR COIL............
_______
°F [°C] DB
_______
°F [°C] WB
HEATING PERFORMANCE
EFFICIENCY ................................
_______
HSPF
TOTAL CAPACITY*..................
_______
MBH [kW]
OUTDOOR DESIGN TEMP. ....
_______
°F [°C] DB
TEMP. OF AIR ENTERING
EVAPORATOR COIL............
_______
°F [°C] DB
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT......................................
_______
IWG
MOTOR RATING ........................
_______
HP [W]
ELECTRICAL DATA
POWER SUPPLY......................
____________ Hz
TOTAL UNIT AMPACITY................
_______
AMPS
MINIMUM WIRE SIZE ....................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ..........
_______
AMPS
CLEARANCES
SERVICE ACCESS 24" [610 mm]
AIR INLETS 12" [305 mm]
ABOVE UNIT 60" [1524 mm]
SUBMITTAL SHEET FOR (-)PRL- JEC 16 SEER REMOTE TWO-STAGE HEAT PUMP UNITS 2, 3, 4 & 5 NOMINAL TON [7.03, 10.5, 14 & 17.58 kW]
Equipped with
Comfort Control
2
System
• Serial communication enabled
• Increased system reliability and efficiency
• 37+ on-board diagnostic and operating codes
Active Protection
with homeowner “Call for Service” alert
• Exclusive Design with dual 7-segment LED display
“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air
conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR
criteria. Ask your Contractor for details or visit www.energystar.gov <http://www.energystar.gov/>.”
AIR DISCHARGE
ALLOW 60 [1524 mm] CLEARANCE
W
H
AIR INLETS (LOUVERS) ALLOW 12 [305 mm] MIN. CLEARANCE 3 SIDES
Model Number
(-)PRL-
024JEC/036JEC/
048JEC/060JEC
Height “H”
(Inches) [mm]
33 [838] 443/8 [1127] 311/2 [800]
L
Length “L”
(Inches) [mm]
earth friendly refrigerant
ACCESS PANE L
ALLOW 24⬙ [610 mm] ACCESS CLEARANCE
Width “W”
(Inches) [mm]
16.0
FEATURES FOR (-)PRL- JEC 16 SEER TWO-STAGE REMOTE HEAT PUMPS
2, 3, 4 & 5 NOMINAL TONS [7.03, 10.5, 14 & 17.58 kW]
FIELD INSTALLED ACCESSORIES
SPECIAL NOTES ON EQUIPMENT:
• Industry’s lowest profile design: 33" maximum height.
• The Comfort Control
2
System™ provides over 37+
on-board diagnostics and fault history codes for condensing units with single-phase compressors by detecting system and electrical problems. The integrated diagnostics with Active Protection™ prevents compressor operation when potentially harmful conditions are detected. Sends “Call for Service” alert notification to the thermostat to alert the homeowner of required service.
• Serial Communication Enhanced – When installed with a Serial Communicating Air Handler ((-)HPL-HM****JC) and user interface control (-HC-TST501CMMS) Series 500 thermostat this unit offers 4 or 2 wire installation, auto-configuration, and diagnostic messaging with full communicating capability.
• Legacy Enabled – Unit can be conventionally wired using 24VAC with non-communicating air-handlers or furnaces with non-communicating thermostat.
• Features a 10-year conditional unit replacement warranty and 10-year parts warranty when properly installed with the Manufacturer’s air handler or the Manufacturer’s indoor coil with the Manufacturer’s gas furnace. See product warranty card for additional information.
• Reliable Two-Stage operation for precise temperature control and On-Demand dehumidification. When matched with ECM gas furnace or air-handler, the system adjusts airflow to help control humidity for unsurpassed comfort in the cooling mode.
• All controls are accessible by removing one service panel. Removable top grille provides access to the condenser fan motor and condenser coil.
• Attractive, louvered wrap-around jacket protects the coil from yard hazards and weather extremes. Top grille is steel reinforced for extra strength. Cabinet is powder painted for all-weather protection.
• For quiet operation and improved efficiency, models feature an ECM two-speed condenser fan motor with a 3-blade outdoor fan.
• All models meet or exceed a 1000-hour salt spray test per ASTM B117 Standard Practice for Operating Salt Spray Testing Apparatus.
• Dual Fuel capable with select thermostats.
[ ] Designates Metric Conversions
Outdoor Thermostats ..................................
3 Heat/2 Cool Thermostats ..........................
Low Ambient Control (RXAD-A08) ................
Blower Time Delay Control (RXMD-C06)........
Dual Fuel High Pressure Control
(Dual Fuel Kit RXME-A01) ........................
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
Rheem Sales Company, Inc. P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A. 10-08 DC FORM NO. X33-1268
Supersedes Form No. X33-1240